Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date26 Sep 2024
Closing Date24 Oct 2024
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in repair factory made (SFRC) precasted reinforced cement concrete round manhole cover as required thickness not less than 100mm for heavy duty and dia of manhole cover not less than 630mm, edge of manhole cover locked with 1mm thick MS sheet complete all as specified and directed.

100

-

-

... More
S&F in repair factory made (SFRC) precasted reinforced cement concrete manhole cover as required thickness not less than 50mm of size 700mm x 550mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and directed.

600

-

-

... More
S&F in repair factory made (SFRC) precasted reinforced cement concrete manhole cover as required thickness not less than 50mm of size 350mm x 350mm, edge of manhole cover to be locked with 1mm thick MS sheet complete all as specified and directed.

750

-

-

... More
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area, complete, all as directed

50

-

-

... More
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified.

50

-

-

... More
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc all as directed.

200

-

-

... More
M & L for rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces of walls, finished even and fair including mixed with and including liquid water proofing compound @200 ML per 50 KG by weight of cement complete all as specified and directed

417

-

-

... More
Supply only liquid water proofing compound

15

-

-

... More
Demolition of reinforced cement concrete in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.

4

-

-

... More
M&L for Reinforced cement concrete Type B1 1:2:4 using 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.

4

-

-

... More
M&L for Mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.

314

-

-

... More
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level.) & removing unserviceable materials in low laying area, complete, all as directed.

3

-

-

... More
M&L for PCC (1:3:6) type C2 using 40 mm graded crushed stone aggregate as in surface channels/ bottom of manhole complete all as specified and directed.

3

-

-

... More
M&L preparation of new untreated surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and as directed by Engr-in-charge.

417

-

-

... More
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed.

500

-

-

... More
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed.

300

-

-

... More
S&F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls & floors with necessary MS clamps complete all as specified and directed.

200

-

-

... More
S&F 110 mm PVC (SWR) bends any radius complete all as specified and directed.

100

-

-

... More
S&F 75 mm PVC (SWR) bends any radius complete all as specified and directed.

67

-

-

... More
S&F 110mm PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed.

60

-

-

... More
S&F 75mm PVC (SWR) junction single,(Single T) equal or unequal complete all as specified and directed.

40

-

-

... More
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed.

30

-

-

... More
Taking down and refixing after repairing cast iron pipe 100mm bore fixed to walls with necessary fittings/ connection/ heads/ shoes/ bends/ swan neck etc & MS clamps/ clip and necessary screwing as required in new or old position complete all as specified and directed.

60

-

-

... More
Taking down and refixing after repairing cast iron pipe 75mm bore fixed to walls with necessary fittings/ connection/ heads/ shoes/ bends/ swan neck etc & MS clamps/ clip and necessary screwing as required in new or old position complete all as specified and directed.

60

-

-

... More
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.

280

-

-

... More
M&L for removing existing branch drain, making good to walling and rendering, cutting out branch channel, and making good benchings as required for 150mm bore pipes complete all as specified and as directed.

20

-

-

... More
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm bore pipes complete all as specified and as directed.

20

-

-

... More
M&L for 150mm bore Sail-glazed stoneware drain pipes laid in trenches and jointed complete all as specified with collars and as directed.

500

-

-

... More
M&L for cement Concrete Type C2 (1:4:8) (using 40mm graded aggregate) bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.

500

-

-

... More
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and as directed.

224

-

-

... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.

56

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.