Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_698004_1Tender No
CA NO GE U AMB T 89 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Removing excavated material/soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
304
-
-
... More
Material and labour for sand cushioning to cable with a layer of sand 8 cm thick before laying the cable and 15 cms thick after laying the cable (punned down to 18 cms depth after laying and stretching of cable) complete all as specified and directed.
202
-
-
... More
Supply and lay bricks, common burnt clay, sub class "B', old size, laid in vertical direction to cable as cable protection complete all as specified and directed.
15
-
-
... More
All as per Srl Item No 6.00 here in before but except bricks.
Note:- Old bricks retrieved from Ser Item No 11.00 to 22.00 here in after shall be re-used.
5
-
-
... More
Material & Labour for cement concrete in foundations, filling and mass concrete PCC as foundation to poles, type D2, 1:4:8 using 40 mm graded stone agregate as foundations to poles complete all as specified and directed.
3
-
-
... More
Material & Labour for Cement concrete, filling and mass concrete, PCC type C2, 1:3:6 using 20 mm graded aggregate complete all as specified and directed.
13.5
-
-
... More
Material & Labour for cement concrete as coping to poles, PCC type B1, 1:2:4 using 20 mm graded stone agregate as foundations to poles a complete all as specified and directed.
1.3
-
-
... More
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc incl bricks and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete all as specified and directed. (Excavation/earth work & sand cushioning, bricks and joint shall be measured & paid for separately).
400
-
-
... More
Supply, laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4.0 core including Aluminium thimbles laid in trenches/on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc including taking out existing U/S cable with bricks complete all as specified and directed. Note : (i) Earth work, sand, bricks, returning filling will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost. Make: Grandlay/ polycab/ Paraflex/ Havells
380
-
-
... More
All as per Srl Item No 12.00 here in before but for 4 core 16 Sqmm .
380
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 25 Sqmm .
350
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 35 Sqmm .
300
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 50 Sqmm .
300
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 70 Sqmm .
300
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 95 Sqmm .
200
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 120 Sqmm .
200
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 150 Sqmm .
200
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 185 Sqmm .
200
-
-
... More
All as per Srl Item No 12.00 here in before but for 3.5 core 240 Sqmm .
150
-
-
... More
Supply & Fixing in replacement of bracket made out of GI tubing single piece not welded, bended at proper angle of size 40mm dia, light grade 1.5 mtr long including painting with aluminium paint over one coat of red oxide primer to the bracket complete all as specified and directed.
40
-
-
... More
Supply & Fixing in replacement of MS clamp suitable for holding street light bracket on steel/PCC pole made out of 40 mm x6 mm thick flat iron with M.S nuts bolts 50 mm long 10 mm dia -3 Nos with flat washer 3mm thick -02 No for each including painting with aluminium paint over one coat of red oxide primer to the M.S clamps complete all as specified and directed.
40
-
-
... More
Supply, fix and erection of Prestressed concrete pole 9.0 mtr long in true vertical position 102x172 mm at top 102x279 mm at bottom class-10 incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr including 2 bands of radium tape of 2' width greeen & red colour above the coping of pole starting with black strip including dismantalling and taking down old unsv pole complete all as specified and directed. . Note:- (i) Earth work and PCC shall be measured and paid seperately (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
12
-
-
... More
Supply, fix and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts,nuts and screws as specified type 410 SP-31, 09 meter long, providing synthetic enamel aluminium paint over one coat of red oxide and black and white strips with synthetic enamel paint 30 cm each alternatively upto 1.5 mtr including 2 bands of radium tape of 2' width greeen & red colour above the coping of pole starting with black strip,including dismantalling and taking down old unsv pole complete all as specified and directed. Note:- (i) Earth work and PCC shall be measured and paid seperately (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
15
-
-
... More
Supply and installation in replacement of all in one integrated Solar street light 25 Watt compact, aesthetic eco friendly and modern integrated Solar Street in extruded aluminium housing with high efficiency mono crystaline silicon photo voltaic panel, high efficency SMD LED 6500K having secondary lens optic for street light distribution,high performance lithium battery, MPPT charge controller and intelligent control, module/sensor with higher reliability long service life including 50 mm bore GI pipe medium grade pole upto 4 mtr height for mounting of Solar Lights suitable for easy and quick instllation including PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) complete all as specified and directed. Make: Halonix/Havells/Orient/Sunlight Infra
10
-
-
... More
Supply and fixing in replacement of fabrication of Kiosk box made out of fibre material complete with TPN ,aluminium bus and suitable for one number MCB (SP) including one No MCB (SP) 6 Amps 240 volts with glands for incoming & out going cable including fixing of flat iron clamps of size 20x4mm on PCC/Steel tubular pole complete all as specified and directed. Make: Havells/Sintex.
45
-
-
... More
Supply and fix in replacement of MCB SP 6-32 Amps, 240 volt,10 KA 'B' curve including all accessories complete all as specified and directed.
10
-
-
... More
Supply and fix in replacement of MCB DP 16-40 Amps, 240 volt,10 KA 'B' curve including all accessories complete all as specified and directed.
5
-
-
... More
Supply and fix in replacement of MCB TPN 32-63 Amps, 240 volt,10 KA 'B' curve including all accessories complete all as specified and directed.
5
-
-
... More
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed.
380
-
-
... More
Supply and fixing in replacement or passing through PVC conduit pipe of 1100 volts grade heavy duty, PVC insulated round 3 core 1.0 sqmm copper cable including electrical connection suitable size of lugs,nuts and bolts complete all as specified and directed.
180
-
-
... More
Supply and fixing in replacement or passing through PVC conduit pipe of 1100 volts grade heavy duty, PVC insulated round 3 core 2.5 sqmm copper cable including electrical connection suitable size of lugs,nuts and bolts complete all as specified and directed.
90
-
-
... More
Supply and fixing in replacement or passing through PVC conduit pipe of single core PVC unsheathed multi stranded copper cable (FRLS) 1.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs, nuts and bolts complete all as specified and directed.
90
-
-
... More
Supply and fixing in replacement or passing through PVC conduit pipe of single core PVC unsheathed multi stranded copper cable (FRLS) 2.5 Sqmm nominal cross sectional area 1100 volts conforming to IS 694 including electrical connection suitable size of lugs, nuts and bolts complete all as specified and directed.
90
-
-
... More
Supply and fixing in replacement of rigid non-metallic PVC conduit of dia 20 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. Note: PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates complete all as specified and directed.
150
-
-
... More
Supplying and fixing in replacement of light grade galvanised mild steel pipe 80mm bore with all fittings, laid under roads, drain, paths, fixed to poles/walls with suitable mild steel clamps, bolts, nuts and washers complete all as specified and directed. . Note:- Excavation & earth work shall be measured and paid for separately under appropriate item of this schedule.
45
-
-
... More
All as per Srl Item No 38.00 here-in-before but of size 40 mm bore complete all as specified and directed.
60
-
-
... More
Material and labour in replacement of broken earth pit of size 300x300x300 mm made of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia TMT bars @ 100 mm centre to centre both ways with handle made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers as required at site with testing result complete all as specified and directed. .
35
-
-
... More
Material and labour in replacement of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed. .
18
-
-
... More
Repairing of existing unserviceable PCC coping of LT/HT pole by breaking completely and material and labour for PCC 1:2:4 type B1, (using 20mm graded crushed stone aggregate) of size 600X600X300mm including form work and applying two coats of cement base paint complete all as specified and directed. .
60
-
-
... More
Dismantling and taking down old u/s earthing and Material and labour for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less than 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead wire of 4.0 mm dia by means of GI nuts bolts, check nuts and washers and connected to earthing test point drawn through 15 mm bore GI pipe medium grade for protection of GI earth lead wire including 20mm bore GI pipe medium grade for watering GI funnel PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part - I including testing complete all as specified and directed.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.
(ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC. (iii) On testing after completion if the desired earth resistance ismore than 2Ώ the earthing will be redone at no extra cost.
10
-
-
... More
Supply and fixing in replacement MCCB TPN 400 Amps, 415 Volts, 36 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl spreader link and connection complete all as specified and directed.
2
-
-
... More
Supply and fixing in replacement MCCB TPN 250 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl spreader link and connection complete all as specified and directed.
3
-
-
... More
Supply and fixing in replacement MCCB TPN 160 Amps, 415 Volts, 16 KA,4 pole , Ics=100% Icu, incl spreader link and connection complete all as specified and directed.
4
-
-
... More
Supply and fixing in replacement MCCB TPN 100 Amps, 415 Volts, 10 KA,4 pole , Ics=100% Icu, incl spreader link and connection complete all as specified and directed.
4
-
-
... More
Material and Labour for Detecting of fault in cable HT/LT with fault locator equipment supplying of HT/LT electric supply (11 KV/430 Volts) to make the HT/LT cable serviceable with Straight through joint of size 70-300 Sqmm complete all as specified and directed.
Note: (a) The HT fault which is detected through cable fault locator will only be paid under this item. (b) Transportation charges of cable fault locator and DG set deemed to be included in the quoted rate. (c) Earth fault locator will be provided by the contractor for even single HT fault and no delay on this account will be acceptable otherwise penalty will levied Rs 500.00 per hour. (d) Straight through joint , 95 to 300, sqm, Labour charges, excavation and making joint deemed to be including in quoted rate.
9
-
-
... More
Supply and fixing in replacement LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 5 line as per IS complete all as specified and directed.
90
-
-
... More
Supply and fixing in replacement LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete all as specified and directed.
90
-
-
... More
Re-streching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length (if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified. Old conductor shall be reused where required for repairing broken length of conductor complete all as specified and directed. Note:- Each run of conductor will be measured and paid seperately.
6500
-
-
... More
Supply and fixing in replacement of sensor of nature switch operation should be based on natural light lux level, required illuminance level for switching on is 30 Lux and for switching off 10 lux , the sensor should also have part night operation facility of min 4 hrs to max 12 hrs complete all as specified and directed Make:- Swadeep , Model nature switch -02(sensor) or equivalent as approved by GE.
4
-
-
... More
Supply and fixing in replacement of contactor three pole 18 Amp in street light timer box coil operating voltage 230 volt complete all as specified and directed Make- BCH/L&T or equivalent as approved by GE
2
-
-
... More
Supply and fixing in replacement of contactor two pole 25/40 Amp in street light timer box coil operating voltage 230 volt complete all as specified and directed Make- L&T/BCH or equivalent as approved by GE
2
-
-
... More
Supply and fixing in replacement of contactor coil (230V) for MU series 25/40 Amps 2 pole contactors complete all as specified and directed Make- L&T (Cat No CS90793) or equivalent as approved by GE
2
-
-
... More
Supply and fixing in replacement of contactor coil (240V) for freedom series 18 Amps 3 pole contactors complete all as specified and directed Make- BCH, Cat No CE15D1N-K or equivalent as approved by GE
2
-
-
... More
Supply and fixing in replacement of VMS (voltage monitoring series) in street light timer box, including all salient features such as selectable under/over voltage trip levels, protection against phase loss & natural loss, protection against phase reversal and phase to phase unbalance (10%), voltage sensing principle and LED indications for power and fault conditions complete all as specified and directed. Make- L&T, Cat No SM500 or equivalent of GIC
3
-
-
... More
Material and labour for aluminium conductor steel reinforced (ACSR) conductor of size ISI marked for LT over head lines on poles including stretching, tightining of poles insulator with winding wire of suitable size with insulator/streching of ACSR conductor including dismantling and taking down old unserviceable ACSR conductor incl cutting, welding complete all as specified and directed.
3.5
-
-
... More
Material and labour for vibratory compactive, precast cement concrete rubber moulded, coloured ( except grey colour), interlocking designer paver blocks in Milano shape, comfirming to IS-15658-2006 of 60 mm thickness, M-35 grade, as in path, harding standing, etc laid over and including 25 mm compacted sand cushioning, including 75 mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate including surface excavation over area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and removing excavated soil exc. 50 mtr but n. exc. 250 mtr including demolition of existing paver blocks, complete all as specified and directed.
140
-
-
... More
Earthing complete with galvanised earth plate electrode 600mm x 600mmx 6.00mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 25x4 mm GI strip earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 40mm bore medium grade and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm bore GI pipe medium grade for watering and 40mm bore GI protection pipe (light grade), funnel, wire mesh, cast iron cover and frame etc, complete, all as specified or indicated and as directed including testing on completion including dismantalling of old U/S earthing complete all as specified and directed.
Note : (i) The quoted rate shall include the cost of earth work, GI pipe for watering, GI protection pipe, funnel, wire mesh, RCC cover, etc. complete. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.
(ii) The quoted rate shall include the cost of the earth pit covers to be conspicuously marked of plate with stand grouted in PCC.
(iii) On testing after completion if the desired earth resistance is more than 2Ώ the earthing will be redone at no extra cost
20
-
-
... More
Supply and fixing in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 10-50 Sqmm including complete all as specified and directed.
20
-
-
... More
Supply and fixing in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm including complete all as specified and directed.
20
-
-
... More
Supply and fix in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled red, with letters, figures and conventional skull and bones in signal white colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed
35
-
-
... More
Material & Labour Chemical spray (DC 2.26 contact cleaner) in container of 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanisum cleanese etc complete all as specified and directed. .
10
-
-
... More
Material and labour in replacement of aluminium terminals (thimbles) after cutting the worn out/faulty cable end from LT pillar/panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable 25 Sqmm 4 core upto 50 Sqmm including necessary connection complete all as specified and directed.
90
-
-
... More
All as per Srl Item No 65.00 here in before but size of LT cable 70 Sqmm 3.5 core upto 120 Sqmm 3.5 core complete all as specified and directed.
65
-
-
... More
All as per Srl Item No 65.00 here in before but size of LT cable 150 Sqmm 3.5 core upto 300 Sqmm 3.5 core complete all as specified and directed.
50
-
-
... More
Material and labour for shifting of transformers/ RMUs/ stabilizers/VCBs/ LT panels/ HT/LT poles/ ACBs/ other materials from one to other site/ Power house/ store by providing Crane/ hydra/ JCB as required at site complete all as specified and directed.
15
-
-
... More
Material & Labour for drilling hole of any size manually as per site requirement, drilling for laying pipes under the road for crossing electrical cable complete all as specified and directed.
60
-
-
... More
Material & Labour for spraying herbicide (Round up) on area to remove unwanted vegitation/grass at various locations complete all as specified and directed.
500
-
-
... More
Supply and fixing in replacement of on load change over switch with sheet steel Enclosure 415 V, 4 pole, 200 Amps capacity fixed on walls/MS frame/pole/LT panel for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed. .
2
-
-
... More
Taking down old unserviceable Indicator lamp any type any colour and supply and fixing new Indicator red/yellow/green including making electrical connection with suitable size of copper lugs duly crimped complete all as specified and directed.
10
-
-
... More
Dismantling and taking down old UNSV LT panel and Supply, installing, testing & commissioning outdoor type cubical panel board of size 2.0mX1.8mX.75m, outer shell made out of 3.15 mm thick CRCA sheet and 60 to 70% outer doors covered by Perspex sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Copper bus bar of 1200 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-56 and breaking capacity 65 KA comprising of the following :-
(a) Supply and fixing Air circuit breaker 800Amp 4 pole, 50KA with microprocessor release MDO- 01 Nos
(b) Supply and fixing MCCB 315 Amps, 36 KA 4 pole 415 Volts AC, adjustable type, (incoming)-02 Nos.
(C) Supply and fixing MCCB 200 Amp, 415 volt, 4 pole, breaking capacity 25 KA , adjustable type (Outgoing)-03 Nos.
(d) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (f) Digital multi function meter -01 Nos
(g) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.
1
-
-
... More
Dismantling and taking down old UNSV LT panel and Supply, installing, testing & commissioning outdoor type cubical panel board of size 2.0mX1.8mX.75m, outer shell made out of 3.15 mm thick CRCA sheet and 60 to 70% outer doors covered by Perspex sheet and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front and back openable double door system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Copper bus bar of 1200 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-56 and breaking capacity 65 KA comprising of the following :-
(a) Supply and fixing Air circuit breaker 800Amp 4 pole, 50KA with microprocessor release MDO- 01 Nos
(b) Supply and fixing MCCB 400 Amps, 36 KA 4 pole 415 Volts AC, adjustable type, (incoming)-01 Nos.
(C) Supply and fixing MCCB 315 Amps, 36 KA 4 pole 415 Volts AC, adjustable type, (incoming)-01 Nos.
(d) Supply and fixing MCCB 200 Amp, 415 volt, 4 pole, breaking capacity 25 KA , adjustable type (Outgoing)-03 Nos.
(e) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos (f) Digital multi function meter -01 Nos
(g) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.
1
-
-
... More
Dismantling and taking down old UNSV LT panel and Supply, installing, testing & commissioning outdoor type cubical panel board of size 1.2mX1.0mX.5m, outer shell made out of 3.15 mm thick CRCA sheet with 60 to 70% perspex sheet of min 3 mm thickness and inner shell made out of 2 mm thick CRCA sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform block type 60 cm above ground level and 30 cm grouting in ground, frame factory fabricated with front and back openable double door system and cable alley (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl copper bus bar of 400 Amp- 03 Nos and 200Amp- 01 No bus bar for nuetral , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:61439/2011 Part-1 and part -2 type test certificate with not less than IP-56 and breaking capacity 65 KA comprising of the following :-
(a) MCCB 250 Amps, 25 KA 4 pole 415 Volts AC, adjustable type, (incoming)-01 No.
(b) MCCB 63 Amp, 415 volt, 4 pole, breaking capacity 16 KA , (Outgoing)-05 Nos.
(c) RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nos
(d) Multi function meter for reading volt, Amp, KWH, Frequency etc including CT Coils complete.
(e) Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cabe lugs, sleeves, glands etc complete are included in quoted rates.
(f) Make of switch gear: Havells/ Indo asian/ C&S/ Hager
5
-
-
... More
Notes for item Sr No. 73.00 to 75.00:-
(i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.
(ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694.
(iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE.
(iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated.(v) Cable will be entered in panles through gland.
(v) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate.
-
-
-
... More
Supply & fixing in replacement of Automatic Street Light Control Switch with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Three phase, 25 Amps per phase, MCB rating 32 Amp, max load 8-12 kw incl circuit copper wire 10 sq.mm. Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 60 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor (NS-02) and VMS). Madel :Swadeep-02EC-8kW3P-VMS complete all as specified and directed.
Note:- (i) S S Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years . (iii) The test certificate and warranty certificate must be provided by supplier.(iv) Cost of marking description on the box is included in quoted rate.
3
-
-
... More
Supply, fixing and testing of auto day/ night on and off photocell.LDR sensor switch 10 Amps for lighting on and off photocell, LDR sensor switch 6amps for lighting on and off water proof 220volt 50HZ,AC supply, model No Quick Sense QS-301 complete with all accessories internally pre-wired including connection with 1.5Sqmm copper conductor from main supply to sensor, sensor to fittings including taking down existing complete all as specified and directed.
20
-
-
... More
Supply and fixing straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4 x 25-50 Sqmm complete all as specified and directed.
10
-
-
... More
Supply and fixing straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-120 Sqmm complete all as specified and directed.
8
-
-
... More
Supply and fixing straight through joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-300 Sqmm complete all as specified and directed.
8
-
-
... More
Supply and fixing in replacement indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 150-240 Sqmm including complete all as specified and directed.
15
-
-
... More
Supply & fixing in replacement of Automatic Street Light Control Switch with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). single phase, 25 Amps per phase, MCB rating 40 Amp, max load 5-8 kw incl circuit copper wire 10 sq.mm. Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 60 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP54. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor (NS-02) and VMS). Madel : Swadeep-02EC-5kW1P-VMS complete all as specified and directed.
Note:- (i) Nut bolts, clamp for fixing on poles/wall are to be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years . (iii) The test certificate and warranty certificate must be provided by supplier.(iv) Cost of marking description on the box is included in quoted rate.
3
-
-
... More
Supply and fixing in replacement MCCB TPN 315 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl spreader link and complete connection all as specified and directed.
1
-
-
... More
Supply and fixing in replacement MCCB TPN 200 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl spreader link and complete connection all as specified and directed.
1
-
-
... More
Note:- Amount of credit of Rs. 127920.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%