Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date25 Nov 2024
Closing Soon23 Dec 2024
Tender Amount₹ 1,48,44,000 
Notes
Download

Costs

Summary

Addn /altn/ Improvement To Depot Smc At Af Stn Palam Under Ge

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Get the Best Price For TMT
Starting from
₹47,811/MT*
Haryana

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lumpsum price worked out by the contractor for "Site clearance, Earth Work and Excavation" as listed in Sch 'A' Part II above/below the lumpsum price of Rs 4,00,285.78 as inserted by MES for Sch 'A' Part -II.

1

400285

-

... More
Sch'A' Part-III (Addn/Altn of SMC Bldg)

-

-

-

... More
Lumpsum price worked out by the contractor for "Addn/Altn of SMC Bldg" as listed in Sch 'A' Part III above/below the lumpsum price of Rs 44,41,139.48 as inserted by MES for Sch 'A' Part -III.

1

4441139

-

... More
Sch'A' Part-IV (EXTERNAL ELECTRIC SUPPLY)

-

-

-

... More
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY" as listed in Sch 'A' Part IV above/below the lumpsum price of Rs 5,23,955.53 as inserted by MES for Sch 'A' Part -IV.

1

523955

-

... More
Sch'A' Part-V (Internal Electric Supply)

-

-

-

... More
Lumpsum price worked out by the contractor for "Internal Electric Supply" as listed in Sch 'A' Part V above/below the lumpsum price of Rs 4,66,723.88 as inserted by MES for Sch 'A' Part -V.

1

466723

-

... More
Sch'A' Part-VI (SEWAGE DISPOSAL)

-

-

-

... More
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Sch 'A' Part VI above/below the lumpsum price of Rs 1,11,114.27 as inserted by MES for Sch 'A' Part -VI.

1

111114

-

... More
Sch'A' Part-VII (Area Drainage)

-

-

-

... More
Lumpsum price worked out by the contractor for "(Area Drainage" as listed in Sch 'A' Part VII above/below the lumpsum price of Rs 10,417.89 as inserted by MES for Sch 'A' Part -VII.

1

10417

-

... More
Sch'A' Part-VIII (Demolition)

-

-

-

... More
Lumpsum price worked out by the contractor for "Demolition" as listed in Sch 'A' Part VIII above/below the lumpsum price of Rs 5,763.03 as inserted by MES for Sch 'A' Part -VIII.

1

5763

-

... More
Sch'A' Part-IX (External Water Supply)

-

-

-

... More
Lumpsum price worked out by the contractor for "External Water Supply" as listed in Sch 'A' Part IX above/below the lumpsum price of Rs 11,096.08 as inserted by MES for Sch 'A' Part -IX.

1

11096

-

... More
Sch'A' Part-X (CHEMICAL EARTHING)

-

-

-

... More
Lumpsum price worked out by the contractor for "CHEMICAL EARTHING" as listed in Sch 'A' Part X above/below the lumpsum price of Rs 74,205.80 as inserted by MES for Sch 'A' Part -X

1

74205

-

... More
Sch'A' Part-XI (INTERNAL WATER SUPPLY)

-

-

-

... More
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY" as listed in Sch 'A' Part -XI above/below the lumpsum price of Rs 59,877.21 as inserted by MES for Sch 'A' Part -XI

1

59877

-

... More
Sch'A' Part-XII (DG SET)

-

-

-

... More
Lumpsum price worked out by the contractor for "DG SET" as listed in Sch 'A' Part -XII above/below the lumpsum price of Rs 1,36,484.13 as inserted by MES for Sch 'A' Part -XII

1

136484

-

... More
Sch'A' Part-XIII (MISC)

-

-

-

... More
(B/R Items)

-

-

-

... More
Taking down existing bitumen felt roof tretment including padding,cement mortar bedding,grass, trees treating with chemical and cleaning the surface and removal outside the MOD land, complete all as specified and directed Note- Taking down earthng strips and solar panel wires from roof and re-fixing on the same position after APP laying is deemed to be inclusive of rate quoted by the contractor

905

-

-

... More
M&L water proofing treatment on roof and vertical surface consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified. (c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/ sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.

905

-

-

... More
M&L for applying two coat Bitumen water proofing aluminium heat resistance paint on the roof as per manufacture instructions complete all as specified and directed by Engr-in-Charge.

905

-

-

... More
Taking down of aluminium partition wall of any size with frame including glass and associries etc all as specified and directed by Engr-in-Charge.

5

-

-

... More
S&F polyster powder coated aluminium anodised glazed sliding window shutters made out from anodised aluminium frame three track of secton 101 x 44x 2.00 mm thick fixed in brick or concrete surface by necessary drilling and rawal plug arrangement etc and section of shutter 34x 44 x 1.50 mm thick with 4 mm thick figure glass sheet glass in glazed window shutter and stainless steel wire clothe in gauzed window shutter including one 100 mm long handle each shutter and all necessary jointing cleats glazing clip, rubber packing and aluminium snap beading, etc complete all as specified and directed. Note - Glass and wire mesh measured seperately. (Make of aluminium section shall be hindalco/Jindal and equivalent).

4.5

-

-

... More
S&F anodised aluminium glazed wall partition with anodised aluminium frame of section 83x44x 2mm including with all necessary suitable screw, rubber packing, aluminium snap beading complete all as specified and directed. ( Sizes of each panel of partition - approx 0.9mx0.60m)

7

-

-

... More
S&F polyester powder coated aluminium frame for door shutter of section 101.0x44.4 mm of gauge 16 fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl polyester powder powder coated aluminium door shutter having style side & top rail of section 85x44.4 of 16 gauge, middle and bottom rail of section 150x44.4 mm 16 gauge (all section of such type having arrangement for fixing glass/pre-laminated board on one or both sides as required) incl aluminium powder coated fittings such handle (2 Nos each shutter), tower bolt 01 Nos each leaf, locks (mortise type lock) glazing clips, rubber packing, anodised aluminium snap beading screw, hinges type B-21 150mm long (3 Nos each shutter) etc and one door stopper two legged with each leaf (shutter) complete all as specified and directed by Engr-in-Charge. Note- Glass, prelaminated board & Duco grill to be measured separately.

7

-

-

... More
S&F Anodised aluminium glazed floor door spring double door shutter polyester powder coated aluminium frame/chowkhat for door shutter of section 101.0x44.4mm of gauge 16 fixed in brick masonery or conrcrete work by necessary drilling and rawl plug aggangement etc incl polyester powder coated aluminium door shutter having style side ane top rail of section 85x44.4 of 16 gauge, middle and bottom rail of section 150x44.4 mm 16 gauge (all section of such type having arrangement for fixing glass/ prelaminated board on one or both sides as required) incl aluminium powder coated fittings such handle (2 Nos each shutter), tower bolt 02 Nos, locks (mortise type lock) glazing clips, rubber packing, anodised aluminium snap beading screw, and one door stopper with each leaf (shutter) complete all as specified and directed by Engr-in-Charge. Note - Glass, pre-laminated board and Grill to be measured seperately)

16

-

-

... More
M&L for 5 mm thick aluminium composite sheet, exterior grade fixed betdween aluminium section with and including snap fitting aluminium clips of polyster powder coated alongwith rubber gasket, complete all as specified and directed by Engr-in-charge

10

-

-

... More
S&F aluminium anodized deco grill DG 208 design as per approved pattern including aluminium U Channel etc complete all as specified and directed by Engr-in-Charge

5

-

-

... More
S&F PTMT waste pipe 31/32 mm bore 80 cm long complete all as specified by Engineer-in -Charge .

18

-

-

... More
M&L Gunitting work for RCC work as in columns, beam, slab, perapet, chajjas facia, landing, balconies etc by removing all loose concrete including plaster, cleaning of surface with wire brushes and fixing welded steel wire mesh 25mm x 25 mm with 2 mm dia steel wire as facia/drops and similar works etc applying an apoxy resin concrete bonding agent treatment over the old concrete surface to bound with the new concrete with approved concrete adhesive of M/S Pidilite/M/S BASF/M/S SIKA (As per manufacturers instruction) to bond old and new concrete, guniting with minium pressure of 2.5 Kg per Sqcm in two layers of total average thickness shall be 40 mm thick with cement mortor (1:2) using Ordinarty portland cement 43 grade mixing with waterproofing admixture polycrete @ 2% by weight of cement complete all as specified and directed. Note :- The following items shall be deemed to be included in quoted rate:- (i) Provn of reqd dia of TMT reinforcement bars and binding/welded with old bars. (ii) After placing the reinforceemnt all concrete surface shall be throughly scrubbking/concreting/plastering (iii) work is to carried out in patches. (iv) Rate for scaffolding etc shall be deemed to included in quoted rate. (v) Guniting from ground floor upto four five storey. (vi) Anti-corrosive protective coating for old reinforced bars. (vii) Finish the top surface of guniting even and fair with truly horizontal/vertical as directed. (viii) Steel wire mesh shall be paid and measured seperetly in respective items.

90

-

-

... More
M&L for precast Kerb stone with plain fair faces 300x150x300 mm depth in PCC 1:1 ½ :3 of shape as approved incl all excavation, embedding in ground and removing surplus spoil upto 50 Mtr distance completed all as specified and as directed.

39

-

-

... More
Re-baring by drilling holes and fixing nozzle if required in existing concrete/brick work as in column, beams, slabs and foundation etc in any position and any description size of hole 14mm, 16mm & 22mm suitable for dowels of size 10mm, 12mm & 16mm respectively (minimum depth 140mm for 10mm & 12 mm dia bars and 180mm for 16mm dia bar, cleaning the surface properly with blow out pump & round brushes and fixing of dowel bars with epoxy resin (resin+hardner). complete all as specified and directed by Engr-in-charge. Note:- (i) Adequate lap length shall be provided as per IS-456-2000. (ii) Reinforced TMT bars where incorporated in work will be paid under the relvent items. (iii) The work shall be carried out upto four storied building with scaffolding and in patches as directed by Engr-in-charg e. (iv) Rate for scaffolding and formwork wherever required and as directed to be included in quoted rate. (v) The works will be executed in different buildings and at scattered locations.

50

-

-

... More
M&L prcast factory made PCC saucer drain of size 600x300x75mm in PCC 1:2:4 with rounded edge fixed in position and pointed in CM 1:4 and finished exposed surface even and smooth complete all as specified and as directed.

85

-

-

... More
S&F sink mixer of 15mm dia telephonic type mixer cast copper alloy fancy type chromium plated crutch and butter fly handle screwed down complete all as specified and directed by Engr-in-Charge

1

-

-

... More
S&F PTMT waste pipe 31/32 mm bore 80 cm long complete all as specified by Engineer-in -Charge .

8

-

-

... More
(E/M Items)

-

-

-

... More
Taking down of existing old unserviceable submain wiring complete all as specified and as directed.

720

-

-

... More
Taking down of existing old unserviceable distribution box including MCB/MCCB complete all as specified and as directed.

7

-

-

... More
S & F MCB SPN of rating 40 Amp, 240 Volt, 10 KA, 'C' series type complete all as specified and as directed.

2

-

-

... More
Supply and fix in replacement of factory made epoxy polyster powder coated VTPN distribution board Triple pole MCB 12 way 415V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, provision for 125 Amps MCCB as one incommer and 8 outgoings triple pole MCB with 2 Neutral bar, 2 Earthbar, Fully insulated busbar rated capacity above 160Amp, shrouded Neutral bars and cable ties for cable management complete all as specified and confirming to IEC 61439-3,Reversible door IP 43 & IP 54. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.

1

-

-

... More
Supply and fix in replacement of factory made epoxy polyster powder coated VTPN distribution board Triple pole MCB 6 way 415V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, provision for 100 Amps MCCB as one incommer and 12 outgoings single pole MCB with 2 Neutral bar, 2 Earthbar, Fully insulated busbar rated capacity above 160Amp, shrouded Neutral bars and cable ties for cable management complete all as specified and confirming to IEC 61439-3,Reversible door IP 43 & IP 54. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.

8

-

-

... More
M&L for hole cutting on wall for 250mm exhaust fan including PCC 1:2:4 complete all as specified and as directed.

10

-

-

... More
Supply and fixing ceiling fan wall mounted fan oscilating type with blades, electronic regulator and accessories, 230 V, 300 mm sweep. Min air delivery 60 CMM with service value 6.00 BEE. Five star rated complete all as specified and as directed.

31

-

-

... More
M & L for cutting/threading of GI tubing in position of size 100/80 mm dia pipe for insertion of new Tees, branches etc. of 40 mm dia bore dia all as directed.

2

-

-

... More
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size not less than 1800x1500x450mm, platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. INCOMING:- (a) MCCB, four pole, 300 Amp, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 No. (b) 450 Amps rated copper bus bar suitable for 04 pole system - 01 No. (c) Phase indicating lamp RYB LED type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with integeral selector switch dully prewired. (e) Ammeter Digital type 0-400 Amp capacity with integeral selector switch and CT coils of suitable capacity 400/5A dully prewired. OUT GOING:- (a) MCCB four pole 160 Amps, 25 KA at 415 Volts, adjustable thermal and magnetic setting- 01 Nos . (b) MCCB four pole 100 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting-03 Nos

1

-

-

... More
Shifting of steel tubular poles by using special T&P and reerecting the same pole within area including dismantling and refxing the foundation and PCC work complete all as specified and directed

2

-

-

... More
Supply and fixing weather proof street light junction box double door of size 325 x 220 x 150 mm including connector of suitable size with 6 Amp single pole MCB side hinged fixing with street light poles using necessary MS clamps, nuts, bolts washers, lugs for incoming and out going cables, gland for cable etc of suitable size complete all as specified and directed. Note : The rates quoted are inclusive of provision and fixing of suitable lugs and glands for cable connection.

6

-

-

... More
Supply and install, testing and commissioning of water cooled diesel engine driven generating set of 160 kVA/ 124kW capacity, 6 cylinder 3 phase, 4 wire, 415 Volts, 1500 RPM, AC power supply with power factor 0.8 coupled directly to self excited, 300 ltr fuel tank, self regulated brushless AC alternator suitable for ambient conditions mounted on a common base plate complete with relay panel for automatic starting on main failure (AMF) control panel and conforming to IS complete with integral acoustic enclosures(should have silent features) modular bolted construction & pure polyester based coating to long life in all weather conditions & for outdoor application/installation, integrated design thereby facilitating/easy handling the design of integral acoustic enclosures should be approved by National Physical laboratory as per Central Pollution Control Board(CPCB) latest regulation/norms with fuel tank , battery & standard accessories & PCC platform of appropriate dimensions for acoustic enclosures 45cm above ground level as recommended by manufacturer, tools & spares as provided by Manufacturer all as specified & directed with the following specifications:- Civil Works : All civil works related to foundation, installation of panel and equipments including making good of existing structure if disturbed during installation and commissioning of Gen Set (Total depth of foundation shall be min 300 mm with anti-vibration pads) deemed to be included in the quoted rate. Note:- (i) Necessary ducts and PCC cover to be provided for cable route from generator to AMF Panel and mains to AMF Panel as directed by Engineer-in-Charge. (ii) Standard tools Kit and Hand pump for filling diesel to the tank shall be supplied by the contractor . (iii) Necessary testing equipment for testing before handing over the work (Phase I and Phase II test ) shall be carried out by the contractor to the entire satisfaction of the Accepting Officer or any person authorised by him and the satisfactory results shall be kept in MES records duly signed by the Contractor, Engineer-in-Charge and Testing Officer.(iv) Contractor shall bring diesel for testing for 18 Hours of Test Run.

1

-

-

... More
Material and labour for on load changeover switch of 200 amps 415 volt 50 Hz with enclosure, stand fixing arrangement and LT cable connection to LT panel complete all as specified and directed by Engr-in-charge

1

-

-

... More
M & L for chemical earthing complete with copper plate earth electrode 90cmx60cmx5 mm thick buried directly in ground (earth pit not less than 4.00 mtr below ground level with top edge of plate not less than 3.25 mtr below ground level) brazed with copper strip 50x6 mm size 7.5 mtr long and connected to copper strip of any size by means of copper bolts, nuts, check nuts and washers complete all as specified and directed. Note:- The rated quoted is deemed to the inclusive of the followings:- (a) The excavation and earth work (filling in, ramming in layers, watering etc as directed) in any type of soil for earth pit (pit size 1.20x 1.20x4.0mtr). (b) Perforated GI tubing (ISI marked) light grade 80mm bore 7.0 mtr long for strip protection and watering. (c) Common salt charcoal dust in alternative layers of 15cm, up to 90cm above the top of copper plate and one layers of 15cm Magnesium sulphate (MgSo4) all as directed (Salt - 500Kg, Charcoal dust - 1000 Kg & MgSo4 - 150 Kg). (d) Earth chamber of internal size 600mmx600mmx600mm, built in PCC (1:3:6) type C2 bed 15cm thick at bottom, brick work in CM 1:6 upto 45cm over PCC bed and PCC (1:3:6) type C1 coping 15cm above, embedded with MS angle 50mmx50mmx3mm frame work duly painted with anti corrosive bituminous paint, with and including RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with XPM (weight not less than 4Kg per Sqm) having lifting arrangement duly painted in green and making earth pit as directed. (e) On testing, after completion, if the earth resistance 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained. (f) GI tubing, bib tap etc for provisioning of continuous water supply at earthing pit will be measured and paid seperately under respective schedule of the contract.

3

-

-

... More
M & L for testing point box of size 100 x 100 x 50 mm depth as per sample complete all as specified.

3

-

-

... More
M & L for copper brazing with copper strip/copper rod complete all as specified.

12

-

-

... More
Supply & Fix in replacement of PVC insulator supporter with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls/PCC blocks etc .

12

-

-

... More
Supply and fixnig air cooled split unit air conditioner electric driven, single phase with cordless remote control unit and with built in ionisser and plasma filter for better indoor air quality of capacity 2 TR 5 star rated and EER 3.2 as specified and directed.

5

-

-

... More
Uninstalling/ Unmounting existing split air conditioners including carefully disconnecting electrical connections and copper tubings from indoor/ outdoor units followed by taking it to the site adjacent to the the building and refixing the same as and when recommended by Engineer in charge.

16

-

-

... More
S&F nylon braided PVC pipe of size 20mm dia outer suitabel for split AC drain including fixing accessories such as claps scews rawl plugs etc complete all as specified and directed

180

-

-

... More
S&F pre-fabricated AC stand suitable for wall mounting or floor mounting made with mild painted with synthetic enamel paint with anti vibration rubber pads including grouting in wall applicable for wall mounting type complete all as specified

5

-

-

... More
M&L for suctionand discharge copper tubing of size 1/2 inch and 1/4 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 2 TR capacity including soldering and braizing complete all as specified and directed. Note:- Suction and discharge copper tubing together wil be measured as one unit of running metre.

30

-

-

... More
M&L for suctionand discharge copper tubing of size 5/8 inch and 3/8 inch dia and 0.5mm thickness from indoor unit to outdoor unit of split type AC 2 TR capacity including soldering and braizing complete all as specified and directed. Note:- Suction and discharge copper tubing together wil be measured as one unit of running metre.

30

-

-

... More
M&L for insulating the suction and discharge copper tubing from in door unit to outdoor unit of split type Acs of capacity 1.5/2.0 TR capacity with neoprene foam sleeves incuding sealing by applying adhesive tape fo brown or white colour to avoid minimum contact with atmosphere complete all as specified and directed

30

-

-

... More
Supply, installation, testing and commissioning voltage stabilizer for automatic operation single phase naturally air cooled indoor type and wall mounting type and designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 vols with accuracy + 2.5% including timedelay relay and LCD display of 5 KVA rated capacity complete.

5

-

-

... More
Dismantling of 73 KWP roof top Grid tied solar power plant at armoury RCC building with following items and including etc.removing materials for taking credit all as specified and as directed by Engr-In-charge (a) Solar PV module 330 wp qty - 222 Nos (b) Solar string inverter of capacity 73 KW -01 Nos (c ) Module mounting structure HDGI with SS hardware of capacity - 73 KW (d) AC wire 1Core X 25 sqmm Copper flexible cable from inverter to till ACDB complete - 10 RM (e) 3.5Core X 50 sqmm aluminium armoured LT cable with cable glands and lugs complete - 30 RM (f) IP-65 poly carbonate with SPD & Gland, Dust & Vermin proof ACDB for 50 KW solar string inverter - 01 Nos (g) Water cleanign system with plumbing & flexible pipe 30 mtr with 0.5 HP water pump complete - 01 job (h) Fire extingushier - 01 set (j) Remote monitoring system - 01 set (k) Pump stand - 01 set (l) Earthing for inverter, MMS - 03 Set (m) Earting strip of size 25x3 mm -60 RM (n) Signage ,Rubber mat, GI saddle,UV PVC cable tie,PVC conduit pipe including flexible pipe 25 & 50 mm ,ferule, lugs, fastners water pipe and earthing insulators - 01 Job (p) civil work with material M25 for 300*300*400 mm block (Approx 65 blocks) & inveter stand & water tank stand complete - 01 Job (q) Unscrewing M6 & M10 SS 304 Nut bolt washer, plain washer, U clamps, Z clamps - 01 Job (r ) DC cable - 750 mtr (s) Dismantling panel structure leg with base plate - 01 set (t) MC4 connector - 01 set

1

-

-

... More
Reinstallation testing and commissioning of 73 KWP roof top Grid tied solar power plant at armoury RCC building with following items and including repl of unserviceable items complete all as specified and directed by Engr-In-charge (a) Solar PV module 330 wp qty - 222 Nos (b) Solar string inverter of capacity 73 KW -01 Nos (c ) Module mounting structure HDGI with SS hardware of capacity - 73 KW (d) AC wire 1Core X 25 sqmm Copper flexible cable from inverter to till ACDB complete - 20 RM (e) 3.5Core X 50 sqmm aluminium armoured LT cable with cable glands and lugs complete - 30 RM (f) IP-65 poly carbonate with SPD & Gland, Dust & Vermin proof ACDB for 50 KW solar string inverter - 01 Nos (g) Water cleanign system with plumbing & flexible pipe 30 mtr with 0.5 HP water pump complete - 01 job (h) Fire extingushier - 01 set (j) Remote monitoring system - 01 set (k) Pump stand - 01 set (l) Earthing for inverter, MMS - 03 Set (m) Earting strip of size 25x3 mm -60 RM (n) Replacement of Signage ,Rubber mat, GI saddle,UV PVC cable tie,PVC conduit pipe including flexible pipe 25 & 50 mm ,ferule, lugs, fastners water pipe and earthing insulators - 01 Job (p) civil work with material M25 for 300*300*400 mm block (Approx 65 blocks) & inveter stand & water tank stand complete - 01 Job (q) Replacement of M6 & M10 SS 304 Nut bolt washer, plain washer, U clamps, Z clamps - 01 Job (r ) DC cable - 750 mtr (s) Replacement of panel structure leg with base plate - 01 set (t) Replacement of MC4 connector - 01 set

1

-

-

... More
Supply and fix electric water heater storage type steel body with copper inner tank and heating element upto 2kW capacity 50 litre BEE 5 star rated with all accessaries such as safety thermostat, NRV, connection piece etc complete all as specified and directed

1

-

-

... More
S & F MCB SPN of rating 40 Amp, 240 Volt, 10 KA, 'C' series type complete all as specified and as directed.

1

-

-

... More
Supply and fix factory made epoxy polyster powder coated VTPN distribution board Triple pole MCB 6 way 415V fabricated from minimum 1.6 mm thick CRCA sheet with double door (IP-43 protection) fixed flush to wall and standard DIN rail, earth bar and cable ties for cable management, provision for 100 Amps MCCB as one incommer and 12 outgoings single pole MCB with 2 Neutral bar, 2 Earthbar, Fully insulated busbar rated capacity above 160Amp, shrouded Neutral bars and cable ties for cable management complete all as specified and confirming to IEC 61439-3,Reversible door IP 43 & IP 54. Note: Cutting on wall and taking out old one and then flushing new DB and making all the connection as before and any accessories required to fix the DB including making good the disturbed surface is deemed to be included in quoted rate.

1

-

-

... More
M&L for hole cutting on wall for 250mm exhaust fan including PCC 1:2:4 complete all as specified and as directed.

9

-

-

... More
Supply and fixing ceiling fan wall mounted fan oscilating type with blades, electronic regulator and accessories, 230 V, 300 mm sweep. Min air delivery 60 CMM with service value 6.00 BEE. Five star rated complete all as specified and as directed.

6

-

-

... More
Schedule of Credit

-

-

-46610.94



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.