Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date21 Dec 2024
Closing Date11 Jan 2025
Tender Amount₹ 48,50,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of cement concrete (un-reinforced) of any description & in any position not specifically provided complete including dismantling of floor tiles etc complete all as specified and as directed.

6.75

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.

390

-

-

... More
M&L for cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregates) 25 mm thick as in sub base of flooring/tiles etc complete all as specified and as directed.

270

-

-

... More
M&L for screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified and as directed.

270

-

-

... More
M&L for 10 mm thick rendering in cement mortar (1:3) on vertical surfaces for backing of tiles etc complete all as specified and as directed.

120

-

-

... More
M&L for Coloured Vitrified Ceramic tiles 9-10 mm thick (Square/rectangular) of light Shade , polished, area of each tile not exceeding 0.36 sqm, fixed in floor/skirting etc over set and jointed in neat cement slurry and pointed in coloured cement to match with coloured tiles complete all as specified and as directed.

150

-

-

... More
M&L for Non - skid (joint free) coloured Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.

120

-

-

... More
M&L for Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and as directed.

120

-

-

... More
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition ) of any description in any position not specifically provided complete complete all as specified and as directed.

2.25

-

-

... More
M&L for providing reinforced cement concrete (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.

2.25

-

-

... More
M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and as directed.

230

-

-

... More
M&L for Formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work not exceeding 200 mm thick rough finished in flat surface complete all as specified and as directed.

15

-

-

... More
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon tal or sloping and similar work exc 5 cm but n exc 10cm wide rough finished complete all as specified and as directed.

25

-

-

... More
Demolition of Mud in roofs, any thickness including plastering and leeping,(whether full thickness removed etc complete all as specified and as directed.

75

-

-

... More
M&L for 40 mm thick PCC (1:2:4) type B-0 (Using 12.50 mm graded stone aggregate) as in roof padding complete all as specified and as directed.

500

-

-

... More
M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4, to be finished even and smooth without using extra cement complete all as specified and as directed.

470

-

-

... More
Supply only intergral water proofing compound ISI Marked complete all as specified and as directed.

75

-

-

... More
M&L for water proofing treatment with APP (Atactic Polypropylene) modified polymeric prefabricated five layer membrane over roof consisting of cleaning of concrete or plaster surface of roof & parapet walls and applying evenly a bitumen primer confirming to IS 3488 @ 0.40 Kg per sqm laid using buten torch and sealing all joints of APP modified polymeric water proofing membrane minimum weight 3.6 kg/sqm reinforced with non woven polyester fabric (weight not less than 160 grams per sqm) unrolled and bonded to substrata with logitudinal and end laps 100 mm and 150 mm respectively as per manufacturer's instructions complete all as specified and as directed.

470

-

-

... More
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.

70

-

-

... More
M&L for providing plain cement concrete (1:2:4) type B0 (using 12.5 mm graded crushed stone aggregate) as in coping or roof kerbs on roof chamfered on edge including trowelling slightly complete all as specified and as directed.

2

-

-

... More
M&L for Cement concrete tiles 25cm x 25cm x 22 mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished, set with grey cement and pigments on roof complete all as specified and as directed.

470

-

-

... More
Removing bldgs demolished materials / debries exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.

75

-

-

... More
Demolition of brick work or rubbled stone masonry built in cement mortar and including removal from the site complete all as specified and as directed.

4

-

-

... More
M&L for brick work with sub class 'B' old size brick, straight or curved on plan exc 6.0 mtr mean radius built in cement mortar 1:6 etc complete all as specified and as directed.

4

-

-

... More
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and including removal of debris and rubbish from the site complete all as specified and as directed.

575

-

-

... More
M&L for rendering 15 mm thick in cement mortar (1:6) on brick work or concrete surfaces finished even and smooth (without using extra cement) complete all as specified and as directed.

200

-

-

... More
M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4, to be finished even and smooth without using extra cement complete all as specified and as directed.

300

-

-

... More
M&L for rendering 10mm thick in cement mortar (1:3) as in ceilings finished even and smooth (without using extra cement) complete all as specified and as directed.

75

-

-

... More
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.

200

-

-

... More
M&L for preparation of plastered or unplastered old decorated surfaces by complete removal of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible , filling of holes and cracks with with suitable material like cement or plaster of paris etc and thereafter applying two coat of oil bound distemper over a coat of primer on walls complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer. (c) Wall care putty shall be measured and paid seperately.

1650

-

-

... More
M&L for preparation of newly plastered surface of ceiling and applying two coats of oil bound distemper over one coat of primer complete all as specified and as directed.

75

-

-

... More
M&L for preparation of old treated plastered or unplastered surfaces of ceiling including cornices by brooming down or steel wire brushing, scraping down, smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spot, filling cracks/holes with putty and applying one coat of distemper oil emulsion on ceiling complete all as specified and as directed.

350

-

-

... More
M&L for preparation of newly plastered surface of wall and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality complete all as specified and as directed.

200

-

-

... More
M&L for preparation(complete removal of existing treatment) of old decorated external wall/ceiling surface of existing treatment by scrapping with Trucare Wall Sander : L-01/H-01 (having mechanical vaccum mechanism) having RPM not less than 1500, sand pad of 80 grit having dia of 7"/9" to make the surface free from dust, loose paint etc or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and applying Two coats of wheather proofing exterior acrylic emulsion paint over a coat of primer premium quality on wall/ceiling surface including applying 1-2mm thick wall care putty over disturbed surface during preparation of any reason, sand papering thus make surface smooth upto 4th storey buildings complete all as specified and as directed. Note : (a) Each stage of complete removal of existing treatment and preparation of surfaces after applying putty shall be got approved from Engg-In-Charge in stage passing register before applying the finishes coat. (b) Material shall be procured from manufacturer and work shall be got executed through authorised applicators of manufacturer.

1350

-

-

... More
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed.

6

-

-

... More
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed.

4

-

-

... More
Taking down shutter of any description exc 1 Sqm and n exc 2 Sqm and removing from site complete all as specified and as directed.

10

-

-

... More
S&F for Pressed steel frames 105X60mm (made out of 1.25mm thick MS Sheet) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed.

30

-

-

... More
M&L for cement concrete (1:3:6) type C1, (using 20 mm graded stone aggregate) as in filling of door frames of pressed steel and in bed blocks etc complete all as specified and as directed.

0.5

-

-

... More
S&F factory made 35 mm thick flush shutters , solid core construction with block board core and plywood face pannel commercial type on both faces complete all as specified and as directed.

20

-

-

... More
S&F solid PVC door frame of size 50mm X47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing complete all as specified and as directed.

18

-

-

... More
S&F factory made PVC shelter panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement , supplying and fixing in the frame at site as per specification & drawing complete all as specified and as directed.

8

-

-

... More
S&F window or ventilators section of frame 72x55mm fixed to wall or concrete surface with rowl plugs made of galvanised steel powder coated and section of shutter 47x20mm mulion section 72x50mm (Based steel as per IS 513 "D" quality galanised as per IS 277 with zinc of 120 gms/sqm) glazed or gauged and wire gauge shutter prepare to receive wire mesh to the shutter (Double door shutter) with total coated thickness of 0.6mm including grills/guard bars made of square bars powder coated fixed to window frame with screws including necessary fittings and all builders hardware such as handles, tower bolts and stays etc complete all as specified and as directed. Make : NCL type-4000 Series or equivalent (Note : Glass and wiremesh shall be measured and paid separately under respective items)

10

-

-

... More
M&L for Framed work such as grills, gratings etc with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.

250

-

-

... More
S&F 100 mm Butt hinges, Stainless steel and fixed complete all as specified and as directed.

60

-

-

... More
S&F 200mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.

40

-

-

... More
S&F 150 mm size extruded aluminium alloy handles fabricated type anodised and fixed complete all as specified and as directed.

40

-

-

... More
S&F 250 mm long aluminium alloy anodised sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast sections or cast aluminium alloy complete all as specified and as directed.

20

-

-

... More
M&L for preparation of new or previously untreated wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.

45

-

-

... More
S&F powder coated anodized aluminum frame for partition, doors, windows, ventilations with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.

225

-

-

... More
S&F powder coated Anodised aluminium window and ventilator shutters, fixed/side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.

20

-

-

... More
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.

2

-

-

... More
S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and as directed.

40

-

-

... More
S&F for 4.8/5.0 mm thick sheet glass ordinary quality and glazing each pane n exc 0.50 Sqm fixed with neoprene rubber gasket in aluminium frame work complete all as specified and as directed.

20

-

-

... More
M&L for 12mm thick Prelaminated Particle board, exterior grade, prelaminated both sides with decorative choice laminations, fixed with screws to timber formwork complete all as specified and as directed.

25

-

-

... More
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staple including necessary beading complete all as specified and as directed.

15

-

-

... More
Dismantling ceiling board (fiber, pulp insulation) or insulation board/slabs etc including grid work/wooden or aluminium frame works, cover fillet etc complete all as specified and as directed.

250

-

-

... More
M & L for clip in type armed strong metallic powder coated 0.5mm thick ceiling with GI framework made of standard Tee , Angle or any other section as in grid type ceiling framework as approved by GE . Ceiling shall be hanged to roof trusses / purlin rafters with the help of GI wire not less than 4mm dia at an interval n. exc 1m , the size of the metallic powder coated ceiling tiles 600 mm x 600 mm complete all as specified and as directed.

250

-

-

... More
S&F in repair 100 mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.

2

-

-

... More
S&F in repair 75 mm Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.

2

-

-

... More
S&F in repair Salt-glazed stoneware gully traps (150X150) mm, square or round mouthed, type 'P' complete all as specified and as directed.

2

-

-

... More
S&F in repair Salt-glazed stoneware gully traps (100X100) mm, square or round mouthed, type 'P' complete all as specified and as directed.

2

-

-

... More
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.

25

-

-

... More
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.

20

-

-

... More
M&L for Cutting chases, pinning in. making good to facings where required andpointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick wall etc complete all as specified and as directed.

25

-

-

... More
Supplying and laying of CPVC pipes 16 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.

25

-

-

... More
Supplying and laying of CPVC pipes 20 mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.

20

-

-

... More
Dismantling of existing water tanks of steel/PVC/AC of capacity exceeding 250 liters but not exceeding 500 litres complete all as specified and as directed.

3

-

-

... More
S&F for rotational moulded polyethylene water storage tanks 500 ltrs capacity (cylinderical vertical with closed top) hoisted and fixed in position all as per SSR Part I complete all as specified and as directed.

3

-

-

... More
S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm bore and fixed, minimum weight of float valve 210 gms complete all as specified and as directed.

3

-

-

... More
S&F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.

3

-

-

... More
S&F in repair white vitreous China wash down water closet pan (pedestal pattern), and trap (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti syphonage pipe, etc. complete all as specified and as directed.

1

-

-

... More
S&F as in repair vitreous china squatting pan, white, orissa pattern, size 580x440mm with integral foot rests (excluding flushing cistern & flush pipe) with cast iron ‘P’ trap incl lime concrete bedding and making good to the disturbed surface to match with the existing surface of floor complete all as specified and as directed.

2

-

-

... More
S&F in repair vitreous china pedestal pattern wash hand basin (flat back) white of size 550x400mm including one number chromium plated waste fittings, 32 mm dia, brass with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, with & including 32 mm dia PVC waste pipe with connector, including cutting for and pinning in ends of brackets complete all as specified and as directed.

2

-

-

... More
S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and as directed.

3

-

-

... More
S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.

3

-

-

... More
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed.

3

-

-

... More
S&F Soap dish of chromium plated or stainless steel fixed to wall with chromium plated brass screws complete all as specified and as directed.

3

-

-

... More
S&F in repair PVC connection 450 mm long suitable for 15 mm GI pipe with two brass nuts & rubber washers complete all as specified and as directed.

12

-

-

... More
S&F in repair brass CP mixer for mixing hot & cold water screwed down for iron pipe 15 mm dia and fixed complete with water saving aerator complete all as specified and as directed.

3

-

-

... More
M&L for 15 mm dia stop valve/angle valve, cast copper alloy screwed down high pressure, fancy type chromium plated screwed both ends for iron pipe or unions complete all as specified and as directed.

6

-

-

... More
S&F in repair of plastic water closet sheet covers white closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device complete all as specified and as directed.

1

-

-

... More
S&F in repair angular two way angle cock with wall flange, 15 mm nominal bore cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions and fixed complete all as specified and as directed.

5

-

-

... More
S&F in repair chromium plated health faucet telephonic type with 8mm dia, 1 meter long CP flexible with wall hook and jet of approved make, suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified and as directed.

3

-

-

... More
S&F in repair bib taps long body, brass, fancy type, chromium plated with crutch or butterfly handles, screwed down, screwed for 15 mm bore GI pipe or for brass ferrule or to GI socket with water saving aerator complete all as specified and as directed.

6

-

-

... More
S&F in repair Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.

3

-

-

... More
M&L for preparation of old painted surfaces of wood & wood based of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.

15

-

-

... More
S&F in repair 25 mm outer dia medium weight pipe made out of stainless steel 304 grade, including decorative ornamental knobs at both ends and one set of ornamental decorative Stainless steel clamps to fixed to walls complete all as specified and as directed.

60

-

-

... More
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and as directed.

20

-

-

... More
S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed.

20

-

-

... More
S&F in repair stainlees steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, wire staples or beading etc, complete all as specified and as directed.

10

-

-

... More
S&F in repair aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long (ISI marked), complete all as specified and as directed.

10

-

-

... More
S&F in repair aluminium anodised, barrel tower bolt of extruded section and fixed, 200 mm long (ISI marked), complete all as specified and as directed.

10

-

-

... More
S&F in repair aluminium alloy, 300mm long anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or excluded sections and fixing bolts and sliding bolts of excluded sections or cast aluminum alloy and fixed, complete all as specified and as directed.

10

-

-

... More
S&F in repair Aluminium alloy handle fabricated type anodised, 150mm long (ISI marked), complete all as specified and as directed.

10

-

-

... More
S&F in repair Double legged Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed to door shutter of size 140mm, complete all as specified and as directed.

10

-

-

... More
Dismantling wall panelling fixed in any position complete all as specified and as directed.

250

-

-

... More
Supply and fixing wall panelling of size 192X2400X15mm Armstrong Channeled woodworks perforated panels of width 192mm thickness of 15mm and length 2400mm or as required by approving engineer made of a high density fibre board with minimum 725Kg/M3 density. substrate with laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The board shall have a special perforation pattern where the visible surface has a "Helmholtz" fluted perforation of 3mm width and 5mm/13mm/21mm of visible paneleach. The edges of the panels shall be "tongue and grooved to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.52-0.63. The panels shall have mounted on special aluminium splines using clips provided by Armstrong and approved by Engineer-in-Charge etc complete all as specified and as directed.

250

-

-

... More
Demolition of cement concrete (un-reinforced) of flooring above or below GF not exc 15cm thick complete including dismantling of floor tiles etc complete all as specified and as directed.

12.83

-

-

... More
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggreate), as in plinth protection including finishing the surface even & smooth without using extra cement complete all as specified and as directed.

5.7

-

-

... More
M&L for 75 mm thick cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregates) as in sub base of flooring etc complete all as specified and as directed.

95

-

-

... More
M&L for screed bed or bedding layer of mortar 20 mm thick in cement mortar (1:4) for bedding of tiles complete all as specified and as directed.

125

-

-

... More
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick,set, jointed and pointed in neat cement slurry in floor with grey cement and pigment to match complete all as specified and as directed.

125

-

-

... More
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.

7.5

-

-

... More
S&F rolled mild steel in framed work as in doors or steel gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing conforming to Fe- 290.Gde-E-165 complete all as specified and as directed.

750

-

-

... More
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.

120

-

-

... More
S&F Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and as directed.

40

-

-

... More
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.

80

-

-

... More
M&L for prepration of new Steel surfaces of any description, not otherwise described, over 10cm width or girth & applying two coats of synthetic enamel paint over coat of red oxide primer complete all as specified and as directed.

25

-

-

... More
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) fitting such as switches, ceiling roses, pendents, regulators, sockets etc complete removing material to store for keeping in safe custody for reuse or takeing in schedule of credit and making good disturbed surfaces of walls, floors etc complete all as specified as directed.

223

-

-

... More
Dismantling and taking down fluorescent tube light single/double of any wattage or size street light fittings for repair or replacement of burnt/worn out accessories or carrying to MES store for reuse or takeing in schedule of credit (Accessories or components to be provided free for replacement by department) complete all as specified as directed.

67

-

-

... More
Taking down unserviceable sub main wiring of any type/size including wires, conduits/battens etc complete all as specified as directed.

510

-

-

... More
Taking down unserviceable / serviciable MCB DB's/AC's box with MCB's to deposit in store for keeping in safe custody for reuse or takeing in schedule of credit of any size/rating complete all as specified as directed.

9

-

-

... More
M&L for point wiring with two runs single core of FRLS PVC insulated sheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawn through in and including concealed PVC conduit size of not less than 20mm concecled in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of FRLS PVC insulated, seathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and making good, disturb surface as it is, all as specified and as directed for the following. Note :- (i) Cutting chases as required on site deemed to be included in the quoted rates. (ii) Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green

-

-

-

... More
One light point controlled by one, one way switch.

65

-

-

... More
One ceiling fan/Exhaust fan point controlled by one, one way switch.

21

-

-

... More
One 3 pin 5 Amp Socket on the same board, complete all as specified as directed.

17

-

-

... More
One 3 pin 5 Amp Socket on independent board , complete all as specified as directed.

63

-

-

... More
M&L for point wiring with two runs single core of FRLS PVC insulated sheathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm drawn through in and including concealed PVC conduit size of not less than 25mm concealed in wall / surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover/modular white cover plate with frame and modular metal flush box of required module at site for mounting switch, socket and fan regulator along with earth wire of FRLS PVC insulated, seathed, 1100 V grade cable multi stranded copper conductor of size 2.5 sqmm and for one 5 pin socket outlet two in one 16/6 amps on an indeendent board including colour coding of cable shall be Phase- Red, Neutral- Black and Earth- Green and making good, disturb surface as it is complete all as specified and as directed. Note :- (i) Cutting chases as required on site deemed to be included in the quoted rates.

57

-

-

... More
M&L in replacement for sub main wiring with two single core FRLS 2.5 sqmm multistranded copper conductor PVC insulated and sheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 2.5 Sqmm FRLS PVC insulated sheathed copper conductor ISI marked as earth wire for post top lantern (Gate light) complete all as specified and as directed. Note :- (i) Cutting chases as required on site deemed to be included in the quoted rates. (ii) Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green.(iii) Two runs of 2.5 sqmm cable and one run of 2.5 sqmm cable of earth continuity conductor and conduit shall be a unit length.

110

-

-

... More
M&L in replacement for sub main wiring with two single core FRLS 4 sqmm multistranded copper conductor PVC insulated and sheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 4 Sqmm FRLS PVC insulated sheathed copper conductor ISI marked as earth wire for Air conditioning 1.5/2 ton complete all as specified and as directed. Note :- (i) Cutting chases as required on site deemed to be included in the quoted rates. (ii) Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green (iii) Two runs of 4 sqmm cable and one run of 4 sqmm cable of earth continuity conductor and conduit shall be a unit length.

260

-

-

... More
M&L in replacement for sub main wiring with two single core FRLS 6 sqmm multistranded copper conductor PVC insulated and sheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 6 Sqmm FRLS PVC insulated sheathed copper conductor ISI marked as earth wire complete all as specified and as directed. Note :- (i) Cutting chases as required on site deemed to be included in the quoted rates. (ii) Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green (iii) Two runs of 6.0 sqmm cable and one run of 6 sqmm cable of earth continuity conductor and conduit shall be a unit length.

140

-

-

... More
M&L in replacement for sub main wiring with two single core FRLS 10 sqmm multistranded copper conductor PVC insulated and sheathed cable ISI marked in 25 mm dia, medium grade, PVC conduit concealed in wall for sub main connection including 10 Sqmm FRLS PVC insulated sheathed copper conductor ISI marked as earth wire complete all as specified and as directed. Note :- (i) Cutting chases as required on site deemed to be included in the quoted rates. (ii) Colour coding of cable should be Phase- Red, Neutral- Black and Earth- Green (iii) Two runs of 10 sqmm cable and one run of 10 sqmm cable of earth continuity conductor and conduit shall be a unit length.

40

-

-

... More
S&F socket outlet, 3 pin 06 Amps flush type, 230 volts complete all as specified and as directed.

80

-

-

... More
S&F socket out let, 3 pin 6/16 Amps 2 in 1, flush type, 230 volts complete all as specified and as directed.

57

-

-

... More
S&F switch piano flush type single pole one way 5 Amps 240 volts complete all as specified and as directed.

86

-

-

... More
S&F switch piano flush type single pole one way 15 Amps 240 volts complete all as specified and as directed.

57

-

-

... More
S&F fan regulator stepped type electronic 300 watt rating, 230 volts complete all as specified and as directed.

18

-

-

... More
S&F ceiling rose, surface bakelite, size as per relevant IS, three terminals complete all as specified and as directed.

86

-

-

... More
S&F in replacement sheet metal enclosure single pole and neutral two pin and earth plug and socket complete with one double pole MCB SP 20 Amps for Geyser/AC complete all as specified and as directed.

3

-

-

... More
S&F in replacement of sheet metal enclosure double door flush mounting type suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar with common neutral link, factory fabricated 12 ways 240 V with IP 54 protection including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate.

4

-

-

... More
S&F in replacement of sheet metal enclosure double door flush mounting type suitable for SPN distribution boards when MCB to be used having 200 Amp rated bus bar with common neutral link, factory fabricated 8 ways 240 V with IP 54 protection including fixing in new location with connection of circuit and submain as per site requirement complete all as specified and as directed . Note- (a) MCBs are to be measured and paid seperately. (b)Make of MCBs and DB should be same.(c) Extra circuit length where DBs are to be shifted from existing location to new location shall deemed to be included in the quoted rate.

3

-

-

... More
S&F of Double door three phase distribution board 8 way IP 54 IK 09 loadline VTPN with 250 Amp MCCB to be used as incomer and made out of CRCA sheets 1.6 mm thick, phosphatised powder coated with copper Bus Bar 250 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks, poly layer for protection complete all as specified and as directed. (Note:-(a) Rate of MCCB and MCBs are included in quoted rate. (b) capacity of Single pole MCB shall be provided as per requirement and direction. (c) Make of MCB /MCCB and DB should be same. (e) Cost of making good the disturbed surface shall deemed to be included in the quoted rate.

2

-

-

... More
S&F MCB, single pole & neutral, 240 Volts ( 40-63) Amps,10KA, 'C' series complete all as specified and as directed.

7

-

-

... More
S&F MCB, single pole, 240 Volts (05 to 32) Amps,10KA, 'C' series complete all as specified and as directed.

50

-

-

... More
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED Polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including complete all as specified as directed.

45

-

-

... More
S&F in replacement of enviroment friendly indoor decorative 9/10 Watt LED polycarbonate Batten with opal diffuser , operating voltage range 140v to 270 V, Driver efficiency 88%, lumen efficiency =100 lm/watt , THD≤ 20 CRI80 , colour temperature 6500 K, inbuilt surge protection = 2.5 Kv, isolation=3.75, and with zero mercury content including all accessaries complete all as specified as directed.

20

-

-

... More
S&F LED bldg light fitting 35/36 Watt, having uniformty ratio 0.25 , high pressure die cast aluminium housing , heat resistant toughened glass frame , IP-65 protection complete with lamp & connected items and connection with suitable cable from celing rose to light fitting and fixing on GI pipe bracket made out of suitable dia GI pipe medium grade 1.2 m long bend to shape and fixed on wall with flat iron clamps nut, bolts washers etc complete all as specified as directed.

2

-

-

... More
Supply and fix heavy duty copper wound exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep 1400 RPM Double bearing with, 04 nos blades,frame,legs and louver complete with making arrangement for fixing of exhaust fan on steel/Aluminium frame window/ making opening in brick wall as per site requirement and also making good to disturbed surfaces as per matching to existing complete all as specified and as directed.

3

-

-

... More
S & F enviroment friendly recess/pendent/surface mounting 36 watt LED flat panel 2'x2' fabricated CRCA sheet steel duly powder coated housing cool white with high efficient LEDs & glare free opal diffuser PF0.95 , lumen efficacy100 lm/W, THD10% operating range 220v to 240V,CRI80 including connection with three core wire and all accessaries complete all as specified as directed.

10

-

-

... More
M&L for earthing complete with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI wire 4 mm Dia as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of 20 mm dia medium grade pipe for watering and light grade 20 mm dia for protection and including all excavation and earth work & connecting the earthing to an earthing test point complete all as specified & as directed . Note:- GI strip upto 7.5 mtr deemed to be included in the quoted rates.

2

-

-

... More
Supply and install hi wall split Type Air conditioner with indoor & outdoor unit complete with Inverter Technology, 3D Airflow, power chill operation,cordless remote control unit and with in built air ioniser, PM 2.5 Filter for better indoor air quality with minimum 5 star rating of capacity 1.5 TR with precharged CFC free(R32/R410A) refrigerant complete all as specified and as directed.

6

-

-

... More
Supply & installed voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V accuracy of 2.5 % and capacity of size 4 KVA complete all as specified and as directed.

6

-

-

... More
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB SP 20-32 Amps complete all as specified and as directed.

6

-

-

... More
M&L for sub main wiring with TWO single core PVC insulated stranded unsheathed FR pvc insulated cable copper conductor single core with size 6 Sqmm (2x6sqmm+1x4sqmm) and drawing through non metallic PVC rigid conduit conealed/surface in wall including PVC insulated unsheathed stranded copper conductor cable connected to earth and earth dolly in conduit including connecting to main board complete all as specified and as directed.

60

-

-

... More
S&F drain pipes 25 mm dia heavy duty rigid PVC from indoor unit to exist point as per design including accessories clamps fastner complete all as specified and as directed.

15

-

-

... More
S&F additional copper tubing 1/4" with rubber insulation unit suitable for 1.5 TR Split AC complete all as specified and as directed.

10

-

-

... More
S&F additional copper tubing 1/2" with rubber insulation unit suitable for 1.5 TR Split AC complete all as specified and as directed.

10

-

-

... More
S&F additional copper cable 3 core 2.5 sqmm suitable for 1.5/2 TR Split AC complete all as specified and as directed.

50

-

-

... More
S&F MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA, complete all as specified and as directed.

6

-

-

... More
M&L for fabrication of Air conditioner outdoor unit shed cover canopy type made of hollo MS square pipe of sizes 25x25x2mm including welding with top GI sheet not less than of 0.7mm thick (Japani sheet) including welding grouting on PCC platform with nuts bolts detachable type complete all as specified and as directed.

6

-

-

... More
M&L for cement concrete in foundation concrete type C1 (1:3:6) mix with 20 mm graded stone aggregate to serve as thrust block for water pipe line complete all as specified and directed. Note :- Pipe line will be required to be laid in trench or above ground as per site requirement in full length or part length, pipe line is passing through jungle area, hill, nala etc. Note lighting arrangement required is included in item rates complete all as specified and as directed.

0.5

-

-

... More
Supply & fix exhaust fans heavy duty 380 mm dia , 50 Hz 230 volt for domestic use,dynamically balance blade , epoxy powder coated confirm to IS 2312-1967 with ISI marking IP-55 with class B insulation motor including suitable size louver and all fixing accessories such as fastners nut bolts and electric connection with 3 core cable complete all as specified and as directed.

3

-

-

... More
Supply & fix wall mounted fan single phase 240 volts of size 400mm sweep and grouting with nuts bolts washers complete all as specified and as directed.

3

-

-

... More
Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 4 core x 25 Sq mm complete all as specified and as dirceted. Note : Provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates.

210

-

-

... More
Supply, laying and testing in replacement of cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 3.5 core x 95 Sq mm complete all as specified and as dirceted. Note : Provision of suitable double crimpped lugs and glands shall deemed to be included in quoted rates.

60

-

-

... More
Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.

46

-

-

... More
Returning filling in including spreading, leveling, watering and well ramming in layers exc 25 cm thick complete all as specified and as directed.

18.5

-

-

... More
Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed.

27.5

-

-

... More
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted. Note : Punned down thickness shall be measured and paid .

18.5

-

-

... More
M&L for sub class ‘B’ bricks old size laid flat dry in trenches over cable, across the direction of cable complete all as specified and as dirceted.

2.34

-

-

... More
Supply and fix in replacement double door TPN DBs 4 way of powder coated DB's suitable for MCCB's fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and as directed.

3

-

-

... More
S & F MCCB 100/63 Amps capacity, 3 pole, 25 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 4 way TPN DB complete all as specified and as directed.

3

-

-

... More
S & F MCB SPN 40 amps 10 KA , B-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed.

23

-

-

... More
Supply and fix in replacement double door TPN DBs 4 way of powder coated DB's suitable for MCB's, Isolator, RCCB etc fitted with bus bar,Neutral link,Earth bar and Din ral & DB's will be fitted concealed in wall / surface as per site required complete all as specified and as directed.

3

-

-

... More
M&L for submain wiring with unsheathed multi-stranded FR Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for 4 runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed. Note :- (i) Four runs of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete. Note (ii): Rates shall deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit.

30

-

-

... More
S & F three phase + neutral industrial power socket, 415 volts, 32 amps complete withmale and female socket complete all as specified and as directed.

5

-

-

... More
S & F MCB triplepole 25 to 63 amps 10 KA , C-series including connection with suitable size aluminium / copper lugs complete all as specified and as directed.

8

-

-

... More
Supply, fixing, testing and commissioning in replacement of feeder pillar panel single door floor mounted and wall/pole mounted outdoor type, as per IP-55 grade, made out of MS sheet 3.15 mm thick of size 1000x800x400mm with aluminium bus bar 250 Amps, 4 strip (3 phase) complete drilled, insulated with colour coded insulation tape, mounted on insulators etc with RYB indicator, panel should be dust proof, vermin proof, powder coated , locking should be screw type, mechanical type, inter locking with 250 Amps 25 KA MCCB four pole for incomer cable, should have danger notice for 415 volts, AC, mounted on 50x50x6 mm angle iron frame having minimum 2 feet ground clearance duly embedded in and including PCC block (1:2:4) complete including termination of all incoming and outgoing cables with suitable size thimbles/lugs and glands etc and providing fixing arrangements including earthing lead fixing arrangement, complete all as specified and as directed. Note :- Installation, testing, commissioning and connecting of incoming and outgoing cable connection LT feeder pillar panel shall included in rates quoted."

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.