Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 98,940Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_688092_1Tender No
GE (FBD)/AF-55/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item No 3 above but depth exc 1.5m and not exc 3m
6
-
-
... More
M&L PCC in 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation/drains and surface channels etc, complete all as specified and directed.
7
-
-
... More
M&L for M-25 (Design Mix) Reinforced cement concrete using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
13
-
-
... More
M&L for M-25 (Design Mix) Reinforced cement concrete using 20 mm graded stone aggregate as in Columns, pillars, piers, posts, struts, basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
9
-
-
... More
M&L for M-25 (Design Mix) Reinforced cement concrete using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span, basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
2.5
-
-
... More
M&L for M-25 (Design Mix) Reinforced cement concrete using 20 mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves, basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
4
-
-
... More
M&L for TMT bar 10 mm dia & over cut to length, bent to shape required including cranking bending spirally for hooping for column, hooking ends & binding with & including mild steel wire (not less than 0.9 mm dia) or securing with clips quality conforming to IS specification, complete all as specified and directed.
3206
-
-
... More
All as per item No 10 above but 6 mm to 8 mm dia.
319
-
-
... More
M&L for 25 mm thick Damp proof course in Plain cement concrete Type B-0 (1:2:4) using 12.5 mm graded stone aggregate for horizontal or vertical surfaces including necessary formwork, complete all as specified and directed.
5
-
-
... More
Formwork to rough finsh to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter, complete all as specified and directed.
370
-
-
... More
Formwork to rough finsh to sides of Square,rectangular or polygonal pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed.
70
-
-
... More
Formwork to rough finsh to flat sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, splays between floors and beams etc, complete all as specified and directed.
18.5
-
-
... More
Formwork to rough finsh to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (Horizontal or sloping), complete all as specifie and directed.
43
-
-
... More
M&L for Brickwork using fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) using standard size bricks, complete all as specified and as directed
16
-
-
... More
M&L for rendering 15mm thick cement plaster on fair faces of brick work or cement concrete surfaces in cement mortar (1:4), finished fair and even without using extra cement incl mixing of water proofing compound as per manufacturer's instructions, complete all as specified. Note: Water Proofing compound shall be measured and paid separately
75
-
-
... More
M&L for rendering 15mm thick cement plaster on fair faces of brick work or cement concrete surfaces in cement mortar (1:6), finished fair and even without using extra cement, complete all as specified and directed.
295
-
-
... More
M & L for rendering 5mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar (1:3), finished even and smooth without using extra cement, complete all as specified and as directed.
43
-
-
... More
M&L for Preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
61
-
-
... More
M&L for Preparation of new surfaces of wall and applying two coats of oil bound distemper over a coat of 1mm thick wall care putty, complete all as specified and directed.
45
-
-
... More
M&L for Preparation of new surfaces of ceiling and applying two coats of white wash, complete all as specified and directed.
43
-
-
... More
M&L for Rendering of 20 mm thick in cement mortar (1:3) over roof slab on concrete surfaces, mixed with water proofing compound @ 3% by weight of cement and finished surfaces fair and even, complete all as specified and directed. Note :- WPC shall be measured and paid separately
51
-
-
... More
Supply only integral water proofing compound complete all as specified and directed.
90
-
-
... More
M&L for Roof treatment on RCC roof slab complete as mentioned below, all as specified and directed:- (i) Cleaning the concrete surfaces of RCC roof slab thoroughly with wire brushes, washed and dried. (ii) Brushing the surface with neat cement slurry at the rate of 3.00 kg of cement per Sqm.
(iii) Cleaning the plastered roof surfaces and applying a coat of bitumen primer @ 0.3 kg/sqm on top of dry surface.
(iv) Laying APP modified polymeric membrane of 3mm thick with non woven polyester core laid and bonded to the sub-strata and over-laps shall be sealed/fused by flame "torch', application method all as per manufacturer's instructions.
51
-
-
... More
M&L for 75mm thick Plain cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in plinth protection or path including necessary formwork complete all as specified and as directed.
24.5
-
-
... More
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per Sqm of surface area with 20% EC, complete all as specified and directed.
24.5
-
-
... More
M & L for treating the top surface of filled earth at the rate of 5 litres of emulsion per Sqm of surface area with 20% EC, complete all as specified and directed.
18
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil, complete all as specified and directed.
32
-
-
... More
M & L for moorum/red bajri filling in floors, pavings etc, laid in layers n exc. 15cm thick, spread, levelled and rammed including watering, complete all as specified and directed.
1
-
-
... More
M & L for hardcore of broken bricks, gauge n.exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and remmed to a true surface, complete all as specified and directed.
3
-
-
... More
M & L for 100mm thick Plain cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate, complete all as specified and as directed.
68
-
-
... More
M & L for 25mm thick Plain cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in bedding layer under floor surface finished even and fair complete all as specified and directed.
18
-
-
... More
M & L for 15mm thick Screed bed or bedding layer in cement mortar (1:6) for laying floor finishes, complete all as specified and as directed.
18.45
-
-
... More
M & L for Fully Vitrified ceramic tiles, Light Shade, 10mm thick polished, area of each tile 600x600 Sqmm laying in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
58.5
-
-
... More
M & L for Fully Vitrified ceramic tiles, Light Shade, 10mm thick polished, area of each tile 600x600 Sqm in skirting, dados, risers etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, work on vertical surfaces such as skirtings, dados and risers to steps etc, complete all as specified and as directed.
1.5
-
-
... More
M&L for Non-skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.06 sqm but n.exc 0.11 sqm as in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match, incl screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar (1:4), complete all as specified and directed
4.5
-
-
... More
M&L for glazed ceramic coloured tiles in vertical surfaces of size 450x300mm and 7mm thick, set and jointed in neat cement slurry, incl. pointed in white or coloured cement to match, complete all as specified and directed.
18
-
-
... More
M&L for Rendering 10mm thick cemenet plaster in cement mortar (1:4) as in backing coat to receive tile, finishes as in skirting and dados etc, complete all as specified and directed.
19
-
-
... More
M&L for providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 59-60 (SuspensionGrade) ,calcium carbonate and natural fibers(wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity indexof 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900N (Edge),minimum compressive strength 50 N/mm2,modulus of elasticity 850 N/mm2 and resistance to spread of flames of class A category with property of being termite /borer proof,water /moisture proof and fire retardant WPC to be laminated with PVC foil of minimum14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screw, complete all as specified and directed.
Note satinless steel butt hinges and necessary SS Screw shall be paid separately.
2
-
-
... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat of size 65x 125 mm in double ribbet comprising of virgin PVC polymer of K value 58-60(Suspension Grade),calcium carbonate and natural fibers (wood powder/rise husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum frames density of 750 kg/cum ,screw withdrawal strength of 2200 N(face) & 1100 N (Edge),minimum compressive strength of 58 N/mm2,modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixed in position with MS Hold fast/lugs/SS dash fasteners of required dia and length, complete al as specified and directed.
Note:-M.S hold fast/lugs or SS Dash fasteners are included in this with this item.
5
-
-
... More
S&F Factory made solid panel PVC door shutter 35 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with. heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and Single Side Prelam PVC sheet used and stile & rails having one side feathered edge and on other side 10mm 900 bent edge for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of wire gauzed i.e. panel will be of wire gauze in lieu of single side prelam PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
2
-
-
... More
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed in wooden/steel/ Aluminium windows, or Stainless steel wire staples, complete all as specified and as directed.
3
-
-
... More
S&F 30mm thick (styles) factory made solid panel PVC door shutters consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20mm width tuck inside with solvent cement for styles & plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and joined together with solvent cement and fixing in the frame at site all as per the specification laid down in SSR Part-I 2009,complete all as specified and directed.
2
-
-
... More
S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with mild steel tube & fixed in position as per manufacturer's instruction & fixing to wall with anchor bolt or screw with plug (size 12 to15 cm long ), complete all as specified and directed.
10
-
-
... More
S&F 100mm long, butt hinges, medium weight ,cold rolled mild steel, complete all as specified and as directed.
35
-
-
... More
S&F 300 mm,aluminium anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolt and sliding bolts of extruded sections or cast aluminium alloy and fixed, complete all as specified and as directed.
2
-
-
... More
S&F floor door stopper of aluminium alloy body double and tongue annodised with rubber shoe and fixed of size 150 mm, complete all as specified and as directed.
2
-
-
... More
S&F 200mm aluminium, anodised, barrel tower bolts of extruded section and fixed etc, complete all as specified and directed
30
-
-
... More
S&F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
20
-
-
... More
Supply and fix power coated (Min thickness of powde coating 50 micron) aluminium frames and shutters for doors, window and ventilator with one and more rebates including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
87
-
-
... More
S&F 4mm thick, tinted glass panes ordinary quality, fixed with Aluminium bead in aluminium frames (area of each pane not exe 0.50 Sq m), complete all as specified and directed.
2.4
-
-
... More
Removal of excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
49
-
-
... More
S&F Framed work such as grills, gratings etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and directed.
564
-
-
... More
M & L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide primer as in camanflauge pattern of different shades, complete all as specified and directed.
135
-
-
... More
S&F 20mm dia. gun metal or gate valves with iron wheel head screwed both ends for iron pipe and fixed, complete all as specified and directed.
3
-
-
... More
S&F 20mm bore, ball valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed
1
-
-
... More
S&F bib tap 15mm bore of standard PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms), complete all as specified and directed.
7
-
-
... More
S&F PVC valveless, syphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern for 10 litres capacity, complete all as specified and directed.
1
-
-
... More
S&F for Vitreous China squatting pan (Orissa pattern) size 580mm x 440mm, white with integral foot rests, any pattern including provision of cement concrete bedding (excluding flushing cistern and flush pipe) complete all as specified and directed.
1
-
-
... More
S&F, Vitreous China wash basin, white, flat back of size 550 x 400 mm including CI brackets, waste coupling ,waste pipe of 32 mm dia low density polythelens (LDPE) pipes of pressure rating 4 Kgf/Sq cm, PTMT pillar tap 15mm screwed down high pressure , PTMT bottle trap, pvc supply pipe 15mm from stop valve etc complete all as specified and directed.
1
-
-
... More
S&F tripple layer, 500 litres capacity, rotational moulded polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position, complete all as specified and directed.
3
-
-
... More
S&F PVC connection,15mm size with PTMT nuts of length 450 mm, complete all as specified and directed.
4
-
-
... More
S&F 110 mm dia bore PVC (SWR) bends any radius, complete all as specified and directed.
19
-
-
... More
S&F 110 mm bore PVC (SWR) vent cowl, complete all as specified and directed.
1
-
-
... More
S&F 110 mm PVC (SWR) WC connector with lip ring, complete all as specified and directed.
1
-
-
... More
S&F 15mm bore tubes 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
10
-
-
... More
S&F 20mm bore tubes 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
10
-
-
... More
S&F 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement all as specified and directed.
1
-
-
... More
S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed.
1
-
-
... More
S&F 15 mm dia. Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) complete all as specified and directed.
4
-
-
... More
S&F GI water tubes of bore 25 mm dia. medium grade with all fittings and connection to main water supply pipe line of 50 or 70 mm dia including excavation and refilling after laying of pipe in ground or floors, complete all as specifie and directed.
80
-
-
... More
S & F 25mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
1
-
-
... More
M&L for Machine pressed, precast, concrete interlocking paver block of any shape and size confirming to IS 15658-2006 of 60mm thickness and M-35 Grade laid with grey cement and no pigment over sand cushoning of thickness as specified and directed by Engineer-in-charge, complete all as specified and directed.
Note :- Sand shall be measured and paid separately.
50
-
-
... More
M & L for Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
2.5
-
-
... More
M&L for Pre-cast cement concrete solid blocks as in kerb stones(factory made), exc.10 cm in width, in 1:2:4 type B1 using 20mm graded stone aggregate and setting in cement mortar (1:6), complete as specified and directed.
0.45
-
-
... More
M&L for preparation new plastered /concrete surfaces as in kerb stone, drains etc, including two coats of synthetic enamel paint with different tints in alternate strips matching to existing pattern, complete all as specified and directed
23
-
-
... More
M&L 150mm internal dia reinforced concerete pipes, class NP2, laid and jointed complete with collars and jointed, complete all as specified and as directed.
20
-
-
... More
S&F 150mm bore, reinforced cement concrete pipe class NP-3 laid and jointed with collars including fittings of same grade in trenches at any depth including jointing and testing, complete all as specified and directed.
15
-
-
... More
M & L for cement concrete (1:3:6) type C-2, using 40mm graded stone aggregate as in bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested, complete all as specified and directed.
35
-
-
... More
Material and labour for PCC (1:3:6) type C-2, using 40mm graded stone aggregate as in Foundation, Filling, Mass concrete, Footings and foundation to manholes etc complete all as specified and directed.
6.4
-
-
... More
Material and labour for PCC 1:2:4, Type B-0, using 12.5 mm graded stone aggregate] in copings ,benching, surface channels and drains including forming fair finished drain or channel of 30 cm inner girth using extra cement including forms, moulds, mitred / stooped ends for manholes beddings, complete all as specified and directed.
1
-
-
... More
Extra for forming fair finished drain or channel n.exc 24 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
3
-
-
... More
S&F ON Site LLDPE septic tank for 05 user With UPFLOW FILTER INLCUDING MEDIA designed to carry sewage and sullage water, incl. excavation in any type of soil, PCC (1:4:8) using 40mm graded stone aggregate below foundation, Vent shaft, connection to sewage line & sockage well etc, complete all as specified and directed.
1
-
-
... More
M&L for Soakage well of size 1.2 M dia X 3 M with effective depth, including excavation in any type of soil, foundation in PCC (1:3:6), walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in cement mortar (1:4), RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats, complete all as directed and specified.
1
-
-
... More
S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20 mm - 210 gms), complete all as specified and directed.
2
-
-
... More
S&F 16 mm bore ,UPVC high grade , including all fittings (like Elbow, Tee, Socket, GI pipe connecter, nipples, tank connector etc) and fixing solutions/adhesive or chemicals and fixed complete to walls, ceilings, laid in floors or concealed, complete all as specified and directed.
10
-
-
... More
S&F 20 mm bore ,UPVC high grade , including all fittings (like Elbow , Tee, Socket, Gi pipe connecter, nipples, tank connector etc) and fixing solutions/adhesive or chemicals and fixed complete to walls, ceilings, laid in floors or concealed, complete all as specified and directed.
50
-
-
... More
S&F 20mm Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight - 20mm/92gms), complete all as specified and directed.
2
-
-
... More
S&F 15mm Stop valve of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight - 15mm/90gms), complete all as specified and directed.
2
-
-
... More
S&F portable Cabin of size 12 Feet x 12 Feet x 8 Feet height with attached toilet of size 4Feet x 4Feet x 8 Feeth height with following specification :- (a) Side wall :- Inside and outer wall shall be made up of PPGI Puff insulated panel 50mm thick, with pre coated GI sheet of 0.50mm thickness.
(b) Roof:- Roof shall be made up of Galvanised sheet of thickness 0.50mm with puff insulation.
(c )Doors:- Main door shall be puff insulated Door with locking arrangement.
(d) Window :- As per requirement.
(e) Colour :- As per choice.
(f) Toilet fittings :- B/R Portion (i) WC (Western type) - 01 No (ii) Wash Basin - 01 No E/M Portion (i) 6 Amp Switch/socket - 01 No (ii) External light point - 02 No (iii) Internal light point - 02 No (iv) Tube light - 02 No (v) Fan point - 01 No
2
-
-
... More
Supply and installation of grease separator plant suitable for underground installation. The Grease Separator should be made from polyethylene for longer life. The Grease Separator should have nominal capacity not less than 930 Ltrs with Inlet/ Outlet socket of nominal dia of minimum 100mm with grease storage capacity of minimum 270 ltrs and sludge storage capacity of minimum 460 ltrs. Total weight of grease separator should be minimum of 81 kg with overall dimension of atleast 1320mm (Diameter) & 1595 mm (Height). The Grease Separator should be capable of cleaning via shaft manhole cover, emptying via suction line with nominal dia of minimum 65mm and nominal pressure of 10 kg with couplings for two-sided thread connection 75/75 mm for suction line, fire hose quick coupling 75 B and 2 1/2 blank cap and Counter flange with fire hose quick coupling 75 B and 2 1/2 black cap. Top cover of the Grease Separator plant should be made from concrete frame with cast iron cover having clear opening of minimum 600 mm diameter. The cover should be odour-free when closed. The weight of the cover should be 145 kg and manufactured to meet 1.50 ton load class requirement. (The rate shall be included for supply & installation, provide three days training for operation/function and transportation at site) as per DIN EN 1825 and DIN 4040 100 suitable for underground installation).Make ACO Passavant ,Model No NS4 Grease Separator plant or equivalent model in Saniflo, Kingspan Klargester, complete all as specified and directed.
3
-
-
... More
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 150mm dia pipe, complete all as specified and directed.
6
-
-
... More
M&L for Brickwork using old size bricks sub class 'B', straight or curved on plan exc 6m mean radius built in cement mortar (1:4), complete all as specified and directed.
25
-
-
... More
M&L for Plain cement concrete type C2 (1:3:6), using 40 mm graded stone aggregate as in surface channels, drains and bed of manhole, complete al as specified and as directed..
2
-
-
... More
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed.
10
-
-
... More
M&L for precast RCC 1:2:4 type B1 using 20 mm graded stone aggregate for manhole cover including placing & set in cement mortar (1:6), complete all as specified and directed.
1
-
-
... More
S&F 150mm dia PVC (SWR) pipes double socketed in any length with rubber ring joints fixed to wall with suitable size of mild steel clamp and screw including making good mouth of rain water pipe in cement mortar (1:3) or PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as per site requirement, complete all as specified and directed.
122
-
-
... More
S&F PVC (SWR ), pipes of 75 mm dia single socketed, in any length with rubber ring joints ,fixed to walls, complete all as specified and directed .
30
-
-
... More
S&F PVC (SWR) pipes single socketed 110mm bore dia, in any length with rubber ring joints, laid in trenches or in floors inclusive fitting, making bellmouth at roof surface, complete all as specified and directed.
108
-
-
... More
S&F UPVC (SWR) bend of any radius of 75mm bore, complete all as specified and directed.
15
-
-
... More
Supply, Laying and testing 20mm bore of pipe in 3 layer PP-R polypropylene random copolymer pipes, SDR 7.4 (PN-16) & SDR 11 UV stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply including all PP-R Plain & brass threaded polypropylene random fitting complete all as specified and directed.
80
-
-
... More
S&F 20 mm stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
14
-
-
... More
S&F 20 mm dia Bib tap, cast copper alloy screwed down high pressure with crutch or butter fly handle on both ends for iron pipe or for union fixed, complete all as specified and directed.
20
-
-
... More
M& L 20mm thick granite (of any type) work in steps, jambs, pillar, window-cills, cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of granite and 15mm thick screed bed in CM 1:4 complete all as specified and directed.
69
-
-
... More
M&L for 10 mm thick cement plaster in cement mortar (1:4) to bricks or concrete surfaces to be finished even and smooth (without using extra cement) complete all as specified and directed.
69
-
-
... More
S&F Fe-290(Gde-E-165) framed work as in doors or gates of angle or other section with gusset plates , rails, braces with ornamental and intricate design . Complete drilled for fixing of steel sheeting or other covering . Door , etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fiftting (exc. of steel sheeting or other covering ,running rails and guides ) and hanging , also fastening and fixing,complete all as specified and directed.
2760
-
-
... More
S&F Fe-290(Gde-E-165) Mild steel plates 6mm thick plain square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and directed.
480
-
-
... More
Removal of excavated soil to a distance exc. 250 m but and n exc 500 m and deposited where directed at a level nexc. 1.5 m above the starting point, complete all as specified and directed.
6.25
-
-
... More
Dismantling structural steeel work including doors, gates but excluding framed truss etc all as specified and directed.
15
-
-
... More
Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar incl all quons, arches, pillars etc but excluding ashlar facing dressed, complete all as specified and directed.
17
-
-
... More
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm, complete all as specified and directed.
544
-
-
... More
Supply, lay, spread in trenches river sand including spreading, levelling, punning for cushioning of cable, complete all as specified and directed.
7
-
-
... More
Supply and laying in trenches, LT underground cable of size 4 core 10 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc.laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, complete all as specified and directed.
136
-
-
... More
S&L GI tubing 'light grade', 40 mm bore laid in trenches,fixing on pole,wall or crossing in drain etc, for protection of UG cable complete all as specified and as directed.
10
-
-
... More
M&L for point wiring in repairs complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 1.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one light/Fan point controlled by one,one way switch complete all as specified and directed.
5
-
-
... More
All as per item No 117 above but one three pin 5 Amps socket out let on independant board with 1.5 sq mm PVC insulated copper conductor for continuous earthing complete.
3
-
-
... More
M&L for point wiring in repairs complete with 2.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including rigid non metallic PVC heavy duty concealed conduit(min 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.12.5 of SSR Part I ) ISI marked with wall thickness not less than 1.8mm including conduit accessories like bends.tees, juction boxes etc fixed concealed in wall/ceiling or surface conduit on ceiling with provision of 2 mm thick pressed steel terminal boxes covered with 3 mm thick plastic laminated white /coloured top cover for mounting switch,socket,fan regulator,industrial socket and all lamp fittings etc including 2.5 sq mm PVC insulated but unsheathed copper conductor FRLS cable,1100 volt grade IS-694 marked as earth contuinity wire for one 15 Amps socket outlet independent board complete all as specified and directed.
1
-
-
... More
S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc, complete all as specified and directed.
1
-
-
... More
Switch piano, flush type single pole, one way 6 Amp, complete all as specified and directed.
8
-
-
... More
S&F ceiling rose surface backlight, 65 x 50 mm three terminals, complete all as specified and directed.
5
-
-
... More
S&F socket outlet, flush type 2 in 1, 3 pin 6 Amp, complete all as specified and directed.
3
-
-
... More
S&F piano switch, flush button single pole one way 16 Amp, complete all as specified and directed.
1
-
-
... More
S&F socket outlet, flush type 2 in 1, 3 pin,6 and 16 Amps flush type, complete all as specified and directed.
1
-
-
... More
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed.
1
-
-
... More
S&F MCB SPN 6 to 32 Amps, 240 Volts,"B" grade, complete all as specified and directed.
1
-
-
... More
Supply and fix MCB single pole, 240 volts, 6 to 32 Amps 10 KA, complete all as specified and directed.
2
-
-
... More
Supply and fixing LED , Tube light fitting 20 W, 6500K Intenso AX LED batten aluminium profile self ballasted surface mounted LED Batten extruded aluminium body with PC diffuser in unic shape. 180º wide light distribution. soft glare free light complete accessories prewired and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting complete all as specified and directed.
3
-
-
... More
Supply and fix ceiling fan 1200 mm sweep, single phase, 230 Volts, AC, 50 Hz alongwith fan hook to be grouted in ceiling and connecting up including provison of cabe from ceiling rose/connector to ceiling fan all as specified and directed.
1
-
-
... More
S&F Fresh Air fan 250 mm sweep, 240 Volt AC single phase including making hole in wall and fixing arrangements complete all as specified and directed.
1
-
-
... More
Supply and install hi wall split units indoor/outdoor with inverter power indoor/outdoor with inverter power supply (V/Hz/Ph) 230/50/1 phase complete with cordless remote control unit and with in built air ioniser, blue fins and plasma filter for better indoor air quality with high EER twin rotary compressor-BLDC, copper condenser coil, variable speed compressor which adjusts power depending on heat load energy efficient and lowest-noise operation capacity: 1.5 ton suitable for large sized rooms, Energy Rating: 5 star rated having ISEER value 4.60, Regrifgerant gas : R 32/R-134a, Environment friendly- no ozone depletion potential & low global warming potential with suitable MS mounting stands for indoor and outdoor unit includig connecting Cu tubings, drain pipe, connecting Cu cable and Cu power cable complete all as specified and directed.
Note : (a). The rate deemed to be included the rate of labour for taking down the old unsrviceable ACs
(b). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.
(c). The cost of copper tubing of size 5/8" and 1/4" with suitable insulation up to a length of 4.5 mtr is deemed to be included in the unit rate quoted. Cost of copper tubing of size 5/8" and 1/4" with suitable insulation beyond 4.5 mtr will be measured and paid separately under the relevant item.
2
-
-
... More
S & F of voltage stablizers for automatic operation , single phase natrally cooled indoor type & designed for input variation between 170 V to 250 V with output stablized at 230 V with accracy of +/- 2.5% and of capacity 3 KVA complete all as specified and directed.
2
-
-
... More
S&F of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB, complete all as specified and directed.
2
-
-
... More
M & L for sub main wiring with two single core FRLS, PVC insulated, stranded, unsheathed copper conductor cable with size 06 Sqmm and drawing through & including metallic Steel conduit concealed in wall including earth continuity conductor of size 06 Sqmm PVC insulated unsheathed multi stranded copper conductor cable with suitable size of Steel Conduit as per IS , Not less than 25 mm and connected to earth dolly to be drawn in concealed Steel conduit including connecting to main distribution board complete all as specified and directed. Note:- Two run of 6 Sqmm PVC wire one run of 6 Sqmm earth continuty wire and one run of matelic conduit Will be measured and paid as single unit .
40
-
-
... More
S&F sheet metal enclosures for MCBs, single pole and neutral 8 ways 240 Volts , double door type isolated neutral with door earthing and bus bar capacity 200 Amps complete all as specified and directed.
1
-
-
... More
S & F MCB SPN, 6 to 32 Amps,C curve, type 101 KA braking capacity 240 volts, complete all as specified and directed.
1
-
-
... More
S & F MCB SP, 6 to 32 Amps,C curve, type 101 KA braking capacity 240 volts,, complete all as specified and directed.
6
-
-
... More
Supply and fixing LED Builiding security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistance complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/55 Protection complete as specified and directed.
2
-
-
... More
M & L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009 complete all as specified and directed. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
2
-
-
... More
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanized iron, complete all as specified and directed.
16
-
-
... More
M&L for providing & fixing false ceiling at all heights with GRG (Glass Fiber With Reinforced Gypsum) false ceiling tiles of perforated Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 tiles fully mm center to center and 40mm long dry wall wood screws. (WITH FULLY PERFORATED 12MM THICK MICRO TEGULAR EDGED GRG FALSE CEILING TILES) The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
110
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%