Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 1,83,900Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Cwe/ggn/ft-28/2024-25 Provn Of Rooftop Solar System At Naraina And Naraina Hill Top And Provn Of Solar Power Plant At Pmg Dadri Under Ge (af) Faridabad
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694205_1Tender No
CWE/GGN/FT-28/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Module Structure
-
-
-
... More
HDGI Structure for 80kWP PV Module : Supply and fixing HDGI structure for 80KWP PV Module comprises of followings : (a) Design of foundation for mounting the structure should be as per defined standards which clearly states the Load Bearing Capacity & other relevant parameters for foundation design (As per IS 6403 / 456 / 4091 / 875).
(b) Grade of raw material to be used for mounting the structures so that it complies the defined wind loading conditions (As per IS 875 - III) should be referred as follows (IS 2062 – for angles and channels, IS 1079 – for sheet, IS 1161 & 1239 for round pipes, IS 4923 for rectangular and square hollow section)
(c) Test reports for the raw material should be as per IS 1852 / 808 / 2062 / 1079 / 811.
(d) In process inspection report as per approved drawing & tolerance should be as per IS 7215.
(e) For ascertaining proper welding of structure part following should be referred: a. D.P. Test (Pin Hole / Crack) (IS 822) b. Weld wire grade should be of grade (ER 70 S - 6)
(f) For ascertaining hot dip galvanizing of fabricated structure following should be referred: - a. Min coating required should be as per IS 4759 & EN 1461. b. Testing of galvanized material ▪ Pierce Test (IS 2633) ▪ Mass of Zinc (IS 6745) ▪ Adhesion Test (IS 2629) ▪ CuSO4 Test (IS 2633) ▪ Superior High-Grade Zinc Ingot should be of 99.999% purity (IS 209) (Preferably Hindustan Zinc Limited or Equivalent).
(g) Foundation Hardware – If using foundation bolt in foundation then it should be as per IS 5624.
Note :- HDGI structure against this Item is for Item No 2.01 of BoQ
1
-
-
... More
Support array/ module mounting structures, mounting Clips shall be manufactured with Hot dip galvanized steel angles & channels; spray galvanized to IS 1477 Part -1 with thickness of 90 microns or aluminium alloy as per IS 5905. All fasteners shall be of Stainless steel (SS 304). MMS having adequate strength & appropriate design and shall be suitable to accommodate 146 No. of Solar Panels which can withstand the load of modules and wind velocity of 150Km/hr, complete with civil work removable concrete ballast made of pre- fabricated PCC (1:2:4) M15 and other required hardware. All solar panels must be accessible from the top for cleaning and from the bottom for access to the module junction box.
-
-
-
... More
Solar MPPT Inverter : Supply and installation of Solar MPPT Inverter comprises of following:-
MPPT Based Grid Tied Solar Inverter with 80 kW X 1 Nos rating with maximum DC Input Voltage 1000V , MPPT range from 200V to 1000V AC output 310-480V, 3 Phase, 4 wire, 50Hz, with inbuilt protection of AC high/low voltage, high/low frequency, DC & AC surge protection device (SPD) class 2 as per IEC 60364-5-53, anti-islanding protection as per VDE 0126-1-1, IEC 60255.5/IEC 60255.27. and LCD display with all parameter like output power(W), energy (Wh), DC voltage & current, AC voltage, current & frequency, operation hours etc. complying to standards as per IEC62109, EN61000-6-2, EN61000-6-3, EN61000-3-12, EN61000-3-11. Invertor has facility RS 485/RS232/RJ45 port for communication interface and its enclosure should be IP 54 for Indoor and IP 65 for outdoor installation. Invertor efficiency should be more than 96%.
1
-
-
... More
AC DC Distribution Board
-
-
-
... More
DCDB
Supply & installation of DC combiner box/Array Junction Box made out of the thermoplastic IP65 protected DIN rail mounting type of following size for interconnection of DC cable of the solar module arrays & DC outgoing cable to DC distribution box complete with termination with cu lugs/ferrule /connectors (MC4) and fixing accessories as required.
Outdoor IP 65 Enclosure – 560mm X 380mm X 130mm Input Postive & Negative Fuse 15A – 4 nos
Solar Output Terminal Block – 4 nos
SPD DC SPD 1000V 40KA type 2 – 4 nos
Input & Output PG Gland – 9 Nos
1
-
-
... More
ACDB
Supply & installation of AC distribution box made out of the thermoplastic IP65 protected DIN rail mounting and front lid transparent type of following size with Phase indication LED lamp, busbar, earth link terminal etc. complete with all fixing accessories as required.
Metal Enclosure 600*400*180 MM Metal Box With IP 65 Rating
ABB MCCB 100A FP 10KA Spreder 100A FP,
Phonix SPD 4 Pole
Metal Gland Etc
Spreder 100A FP,
Busbar Supportor 100A
RYB Indicator Reputed Make
Copper Cable Flexible 25Sq.mm Connectwell terminal Block
Earthing Termianl Green & Yellow Color
Double Compression Gland (Brass)
Standard Indicating Sticker
1
-
-
... More
Multi function Meter : Instantaneous RMS values
Current: Average line current of 3-phase, per-phase, and calculated neutral current
Voltage: Average voltage of L-L, L-N parameters, and per-phase
Frequency Any available line: Real, reactive, and apparent power, Total and per-phase value, Displacement power factor, Average and per-phase signed, four-quadrant
True power factor, Average and per-phase signed, four-quadrant
Demand values
Current average: Present, Last, Predicted, Peak, and Peak Date Time
Active power: Present, Last, Predicted, Peak, and Peak Date Time
Reactive power: Present, Last, Predicted, Peak, and Peak Date Time
Apparent power: Present, Last, Predicted, Peak, and Peak Date Time
Demand sync methods: Thermal, Timed, Command Sync, and Clocked Sync
Demand calculation mode: Sliding, fixed and rolling block
-
-
-
... More
Cable And Cable Termination
-
-
-
... More
DC Cable
Supplying and laying of following sizes of 4.0 sqmm XLPE insulated and sheathed, UV stablished/protected Single core flexible copper conductor DC cable layed in existing PVC/HDPE conduit pipe suitable for outdoor installation complete with termination with tinned copper end-ferrules, special connector (MC4), gland etc. as required. All DC cable shall be supplied confirming to IEC 60502 / IS 1554 voltage rating 1500 V grade.
4 SQ.MM. single core flexible Copper UV protected XLPE cable. Electron beam cross linked compound
UV, Ozone, Temperature & Hydrolysis resistant, Flame Retardant, Low Smoke, Excellent Encapsulation Very long / Service life 25
Standards / Material Properties
Fire performance : IEC 60332-1-2
Smoke emission : IEC 61034/ EN 50268-2
Halogen Free: EN 50267-2-1/-2, IEC 60754-2
Toxicity: EN 50305, ITC – Index 3
Ozone Resistant : EN50396
Weathering UV: HD 605/A1 or DIN 53367
Approvals : EN 50618; H1Z2Z2-k
Note :- DC cable under this item is to be executed for All sites / locations.
4600
-
-
... More
AC Wire
Supplying and laying of following sizes of LT XLPE insulated and PVC sheathed Single/multi core armoured Aluminium conductor AC cable layed in wall/ceiling complete with fixing accessories like clamp, saddle, pvc slip screws etc. as required. All AC cable shall be supplied confirming to IEC 60227 / IS 694 voltage rating 1100 V grade.
.
• Voltage Rating : 1100 Volts
• Temperature Rating : -40 to +90 Deg.C
• UV Resistance
• RoHS Compliant Technical Specifications
Conductor Aluminum Conductor IS 8130
Insulation XLPE IS 7098 Part-1
Insulation Colour Red , Yellow , Blue & Black IS 7098 Part-1
Inner Sheath Extruded PVC Type ST-1, Extruded HR PVC Type ST-2 IS 5831
Armouring (as applicable) :GS Round Wire, GS Flat Strip IS 8130
Outer Sheath Extruded PVC Type ST-1, Extruded HR PVC Type ST-2 IS 5831
Colour Black or optional
Special Properties: Flame Retardant, Flame Retardant low smoke, Flame Retardant low smoke zero halogen
-
-
-
... More
4 Core X 50 SQ. MM., Aluminum Conductor, XLPE Insulated, Un-armoured / GS Round wire Armoured / GS Flat Strip Armoured, PVC Outer Sheath Cable conforming to IS 7098 Part-1 with up to date amendment
350
-
-
... More
4 Core X 35 SQ. MM., Aluminum Conductor, XLPE Insulated, Un-armoured / GS Round wire Armoured / GS Flat Strip Armoured, PVC Outer Sheath Cable conforming to IS 7098 Part-1 with up to date amendment
200
-
-
... More
AC Cable Termination Supplying and making end termination of following sizes of LT XLPE insulated and PVC sheathed Single/multi core armoured Aluminium conductor AC cable termination with tinned end-ferrules/lugs and single compression cable gland, pvc tap as required.
-
-
-
... More
4 Core x50 sq mm. Armoured Aluminium conductor XLPE cable.
8
-
-
... More
4 Core x 35 sq mm. Armoured Aluminium conductor XLPE cable.
8
-
-
... More
CONDUIT
Supply and fixing of following sizes of heavy duty PVC/HDPE conduit pipe along with all accessories like bend, JB, thermo plastic clamp/saddle, pvc slip, screws etc. fixed on surface /recessed in wall/ceiling, complete with cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
... More
32mm heavy duty PVC/HDPE conduit pipe.
700
-
-
... More
25mm heavy duty PVC/HDPE conduit pipe.
1600
-
-
... More
20mm heavy duty PVC/HDPE conduit pipe.
1600
-
-
... More
Earthing Protection System : Supply and installation of Earthing Protection System comprises of following:-
(a)The earthing shall be done in accordance with latest Standards.
(b) Each array structure of the PV yard, Low Tension (LT) power system,
earthing grid for switchyard, all electrical equipment, inverter, all junction
boxes, etc. shall be grounded properly as per IS 3043-2018.
(c) All metal casing/ shielding of the plant shall be thoroughly grounded in
accordance with CEA Safety Regulation 2010. In addition, the lightning
arrester/masts should also be earthed inside the array field.
(d) Earth resistance should be as low as possible and shall never be higher than
5 ohms.
(e) For 30 KW and above systems, separate three earth pits shall be provided
for individual three earthing viz.: DC side earthing, AC side earthing and
lightning arrestor earthing.
(f) Supply of UL Listed & CPRI Tested Maintenance Free Copper coated Earth rod comprises of molecularly bonded copper of 99.9% purity of 3048mm length having the dia of 17.2mm dia with copper coating thickness of 254 microns with fault current withstand capability of 25kA rms value for 0.5 Second and I peak of 53kA.The rod has been tested for Dimension, Marking, Tensile Strength, Salt mist, coating thickness, Electrical resistivity test before and after corrosion test as per IEC 62561-2 & UL 467. (g) Eco friendly and Rust proof earth pit chambers with the dimensions of Size 300x300x300 and Load capacity Bearing of 5000Kgs.
(h) Supply of earth enhancing mineral compound tested for leaching and TCLP with NABL - 25kg.The bore shall of dia 75-100mm only which has a lesser resistivity than 0.15 ohms. Note :- Earthing under this item is to be executed for All sites / locations.
23
-
-
... More
Lightning Protection System : Supply and installation of Lightning Protection System comprises of following:-
(a) The SPV power plants shall be provided with lightning & over voltage protection, if required. The main aim in this protection shall be to reduce the overvoltage to a tolerable value before it reaches the PV or other sub system components. The source of over voltage can be lightning, atmosphere disturbances etc. Lightning arrestor shall not be installed on the mounting structure.
(b) The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors (LAs). Lightning protection should be provided as per NFC17-102:2011/IEC 62305 standard.
(c) The protection against induced high-voltages shall be provided by the use of Metal Oxide Varistors (MOVs)/ Franklin Rod type LA/Early streamer type LA.
(d) The current carrying cable from lightning arrestor to the earth pit should have sufficient current carrying capacity according to IEC 62305. According to standard, the minimum requirement for a lightning protection system designed for class of LPS III is a 6 mm2 copper/ 16 mm2 aluminum or GI strip bearing size 25*3 mm thick). Separate pipe for running earth wires of Lightning Arrestor shall be used.
(e) Conventional Lightning Arrestor 14mmX3000mm Cu Bonded With 5 Spikes Including GI Pole of 5m Height and all the accessories i.e, Nut, Bolt, Washer etc required for installation.
Note :- Lightning Protection system under this item is to be executed for All sites / locations.
5
-
-
... More
Earthing And LA Wire
Supply and fixing of earthing system of following sizes of wire / strip along with fixing & termination accessories like tinned copper end- ferrules/lugs, thermo plastic clamp/saddle, pvc slip, screws etc. earthing for all PV module structure components, LA, all distribution boxes,invertor etc. earthing shall be done in accordance with IS 3043- 1986 and earthing resistance will not be more than 5 ohm.
16 sqmm. single core flexible Copper UV protected XLPE cable (Green colour) .
Conductor Material: Copper
Number Of Core: 1
Size: 16 Sqmm
Insulation: Yes
Current Carrying Capacity Rating: 81.6Amp
Resistance (Max.) per km. @ 20O C 1.21 Ohm
Voltage: 1100V
Approx. Overall Diameter: 6.90 mm
Maximum Diameter of Each Strand: 0.41 mm
Insulation Material: PVC
No. of Strands: 120
Thickness of Insulation: 1.0 mm
Note :- LA wire under this item is to be executed for All sites / locations.
1500
-
-
... More
Earthing Strips
Supply, installation of GI Strip for DC/Structure Earthing With All the Accessories including, Screw, Saddle, PVC Gitti, DMC Insulators at every 1M and required material for complete insulation.
25x5 mm GI Strip
Recommended practice for hot dip galvanized of Iron Earthing Strips: IS: 2629(1966)
Methods of testing weight, thickness & uniformity of coating on hot dip galvanized articles: IS: 2633(1972)
Specification for hot dip galvanized coating on fastness I IS: 5358(1969)
Specification for Electroplating IS:3203
Specification for hot dip Zinc coating on structural & other allied products: IS: 4759(1968)
Note :- Earthing strip under this item is to be executed for All sites / locations.
2100
-
-
... More
Civil Work Required for fixing HDGI structure for 80 KW PV Module ( BoQ Item No 3.00 )
Supply, installation of concrete blocks in adequate Nos of Minimum of M20 Grade Size LXBXH (300mmX300mmx300mm) or (300mmx300mmx600mm) as directed by Engr-in-charge with All the Accessories including formwork and all accessories required including Hardware for complete instalation.
Foundation Tapering Foundation Finishing
Cubical concrete block size 300mmx300mmx600mm for column height more than 3m Cubical concrete block size 300mmx300mmx300mm for column height less than 3m
1
-
-
... More
Communication Cable Supply, installation & termination of Mudbus cable/cat 6 cable in PVC conduit pipe for centralized data interface/monitoring, complete with RJ 45 mail connector.
Note :- Communication cable under this item is to be executed for All sites / locations.
112
-
-
... More
PROVN OF SOLAR POWER PLANT AT PMG DADRI
-
-
-
... More
150KWp Solar Power System for AFS Dadri
(a)30kW (AC)- 01 Nos on Project building, Dadri Airforce Station
(b) 70 KWp (AC) - 01 Nos on Admin Bldg, Dadri Airforce Station (c) 50 KWp (AC) 01 Nos on HQ Building Dadri Airforce Station Design, shop drawing, fabrication, Procurement, supply, installation, testing, commissioning & handing over of following capacity Roof top Solar Photovoltaic Power generation system of without battery backup, integration with grid, complete with all accessories as required.
-
-
-
... More
70kWP System @ Admin Bldg, Dadri Airforce Station Supply, installation and interconnection of 128 mono crystalline high efficiency Cell Dual Glass 3.2 MM thick Solar PV module (305P6C-36-DG) /140 Cell Single glass multicrystalline 4mm thick Solar Pv module with AR Coating with Power output Capacity of each solar PV module 550W. Total Solar PV module arrays Capacity a set of (150kWp) at STC. The Solar Panels should Comply as per IEC 61215 and IEC 61730 standard. DC cable/wire of suitable size up to 2Mt/solar pv module with solar pv connectors (MC4)/ couplers etc. shall be included in this item. efficiency of solar pv modules should be equal or more than 16%.
128
-
-
... More
50kWP System @ HQ Building Dadri Airforce Station
Supply, installation and interconnection of 91 mono crystalline high efficiency Cell Dual Glass 3.2 MM thick Solar PV module (305P6C-36-DG) /140 Cell Single glass multicrystalline 4mm thick Solar Pv module with AR Coating with Power output Capacity of each solar PV module 550W. Total Solar PV module arrays Capacity a set of (50kWp) at STC. The Solar Panels should Comply as per IEC 61215 and IEC 61730 standard. DC cable/wire of suitable size up to 2Mt/solar pv module with solar pv connectors (MC4)/ couplers etc. shall be included in this item. efficiency of solar pv modules should be equal or more than 16%.
91
-
-
... More
30kWP System @ Project Building Dadri Airforce Station
Supply, installation and interconnection of 55 mono crystalline high efficiency Cell Dual Glass 3.2 MM thick Solar PV module (305P6C-36-DG) /140 Cell Single glass multicrystalline 4mm thick Solar Pv module with AR Coating with Power output Capacity of each solar PV module 550W. Total Solar PV module arrays Capacity a set of (30kWp) at STC. The Solar Panels should Comply as per IEC 61215 and IEC 61730 standard. DC cable/wire of suitable size up to 2Mt/solar pv module with solar pv connectors (MC4)/ couplers etc. shall be included in this item. efficiency of solar pv modules should be equal or more than 16%.
55
-
-
... More
Module Structure HDGI Structure for 70kWP PV Module
Design of foundation for mounting the structure should be as per defined standards which clearly states the Load Bearing Capacity & other relevant parameters for foundation design (As per IS 6403 / 456 / 4091 / 875).
ii. Grade of raw material to be used for mounting the structures so that it complies the defined wind loading conditions (As per IS 875 - III) should be referred as follows (IS 2062 – for angles and channels, IS 1079 – for sheet, IS 1161 & 1239 for round pipes, IS 4923 for rectangular and square hollow section)
iii. Test reports for the raw material should be as per IS 1852 / 808 / 2062 / 1079 / 811.
iv. In process inspection report as per approved drawing & tolerance should be as per IS 7215.
v. For ascertaining proper welding of structure part following should be referred:
a. D.P. Test (Pin Hole / Crack) (IS 822)
b. Weld wire grade should be of grade (ER 70 S - 6)
vi. For ascertaining hot dip galvanizing of fabricated structure following should be referred: -
a. Min coating required should be as per IS 4759 & EN 1461.
b. Testing of galvanized material
▪ Pierce Test (IS 2633)
▪ Mass of Zinc (IS 6745)
▪ Adhesion Test (IS 2629)
▪ CuSO4 Test (IS 2633)
▪ Superior High-Grade Zinc Ingot should be of 99.999% purity (IS 209)
(Preferably Hindustan Zinc Limited or Equivalent).
vii.Foundation Hardware – If using foundation bolt in foundation then it should be
as per IS 5624.
Note :- HDGI structure against this Item is for Item No 17.01 of BoQ
1
-
-
... More
Support array/module mounting structures, mounting Clips shall be manufactured with Hot dip galvanized steel angles & channels; spray galvanized to IS 1477 Part -1 with thickness of 90 microns or aluminium alloy as per IS 5905. All fasteners shall be of Stainless steel (SS 304). MMS having adequate strength & appropriate design and shall be suitable to accommodate 128 Nos of Solar Panels which can withstand the load of modules and wind velocity of 150Km/hr, complete with civil work removable concrete ballast made of pre- fabricated PCC (1:2:4) M15 and other required hardware. All solar panels must be accessible from the top for cleaning and from the bottom for access to the module junction box.
-
-
-
... More
Module Structure HDGI Structure for 50kWP PV Module
Design of foundation for mounting the structure should be as per defined standards which clearly states the Load Bearing Capacity & other relevant parameters for foundation design (As per IS 6403 / 456 / 4091 / 875).
ii. Grade of raw material to be used for mounting the structures so that it complies the defined wind loading conditions (As per IS 875 - III) should be referred as follows (IS 2062 – for angles and channels, IS 1079 – for sheet, IS 1161 & 1239 for round pipes, IS 4923 for rectangular and square hollow section)
iii. Test reports for the raw material should be as per IS 1852 / 808 / 2062 / 1079 / 811.
iv. In process inspection report as per approved drawing & tolerance should be as per IS 7215.
v. For ascertaining proper welding of structure part following should be referred:
a. D.P. Test (Pin Hole / Crack) (IS 822)
b. Weld wire grade should be of grade (ER 70 S - 6)
vi. For ascertaining hot dip galvanizing of fabricated structure following should be referred: -
a. Min coating required should be as per IS 4759 & EN 1461.
b. Testing of galvanized material
▪ Pierce Test (IS 2633)
▪ Mass of Zinc (IS 6745)
▪ Adhesion Test (IS 2629)
▪ CuSO4 Test (IS 2633)
▪ Superior High-Grade Zinc Ingot should be of 99.999% purity (IS 209)
(Preferably Hindustan Zinc Limited or Equivalent).
vii.Foundation Hardware – If using foundation bolt in foundation then it should be
as per IS 5624.
Note :- HDGI structure against this Item is for Item No 17.02 of BoQ
1
-
-
... More
Support array/module mounting structures, mounting Clips shall be manufactured with Hot dip galvanized steel angles & channels; spray galvanized to IS 1477 Part -1 with thickness of 90 microns or aluminium alloy as per IS 5905. All fasteners shall be of Stainless steel (SS 304). MMS having adequate strength & appropriate design and shall be suitable to accommodate 91 Nos of Solar Panels which can withstand the load of modules and wind velocity of 150Km/hr, complete with civil work removable concrete ballast made of pre- fabricated PCC (1:2:4) M15 and other required hardware. All solar panels must be accessible from the top for cleaning and from the bottom for access to the module junction box.
-
-
-
... More
Module Structure Mono Rail Structure For 30kW Solar Supply, installation and interconnection of 55 mono crystalline high efficiency Cell Dual Glass 3.2 MM thick Solar PV module inlucliding DC cable/wire of suitable size up to 2Mt/solar pv module with solar pv connectors (MC4)/ couplers etc. shall be included in this item. Including all the accessories, Screw, PVC Saddle, Bond, Clamp or any accessories required for installation of PV Modules.
Frame Material: Aluminium
Size: 280 MM
Design Type: Modular
Bearable Wind Speed: 150 KMPH
Usage/Application: Solar Panel Mounting
Material: Aluminium
Thickness: 3 MM
220
-
-
... More
Solar MPPT Inverter
-
-
-
... More
MPPT Based Grid Tied Solar Inverter with 70 kW X 1 Nos rating with maximum DC Input Voltage 1000V , MPPT range from 200V to 1000V AC output 310-480V, 3 Phase, 4 wire, 50Hz, with inbuilt protection of AC high/low voltage, high/low frequency, DC & AC surge protection device (SPD) class 2 as per IEC 60364-5-53, anti-islanding protection as per VDE 0126-1-1, IEC 60255.5/IEC 60255.27. and LCD display with all parameter like output power(W), energy (Wh), DC voltage & current, AC voltage, current & frequency, operation hours etc. complying to standards as per IEC62109, EN61000-6-2, EN61000-6-3, EN61000-3-12, EN61000-3-11. Invertor has facility RS 485/RS232/RJ45 port for communication interface and its enclosure should be IP 54 for Indoor and IP 65 for outdoor installation. Invertor efficiency should be more than 96%.
1
-
-
... More
MPPT Based Grid Tied Solar Inverter with 50 kW X 1 Nos rating with maximum DC Input Voltage 1000V , MPPT range from 300V to 950V AC output 310-480V, 3 Phase, 4 wire, 50Hz, with inbuilt protection of AC high/low voltage, high/low frequency, DC & AC surge protection device (SPD) class 2 as per IEC 60364-5-53, anti-islanding protection as per VDE 0126-1-1, IEC 60255.5/IEC 60255.27. and LCD display with all parameter like output power(W), energy (Wh), DC voltage & current, AC voltage, current & frequency, operation hours etc. complying to standards as per IEC62109, EN61000-6-2, EN61000-6-3, EN61000-3-12, EN61000-3-11. Invertor has facility RS 485/RS232/RJ45 port for communication interface and its enclosure should be IP 54 for Indoor and IP 65 for outdoor installation. Invertor efficiency should be more than 96%.
1
-
-
... More
MPPT Based Grid Tied Solar Inverter with 30 kW X 1 Nos rating with maximum DC Input Voltage 1000V , MPPT range from 300V to 950V AC output 310-480V, 3 Phase, 4 wire, 50Hz, with inbuilt protection of AC high/low voltage, high/low frequency, DC & AC surge protection device (SPD) class 2 as per IEC 60364-5-53, anti-islanding protection as per VDE 0126-1-1, IEC 60255.5/IEC 60255.27. and LCD display with all parameter like output power(W), energy (Wh), DC voltage & current, AC voltage, current & frequency, operation hours etc. complying to standards as per IEC62109, EN61000-6-2, EN61000-6-3, EN61000-3-12, EN61000-3-11. Invertor has facility RS 485/RS232/RJ45 port for communication interface and its enclosure should be IP 54 for Indoor and IP 65 for outdoor installation. Invertor efficiency should be more than 96%.
1
-
-
... More
AC DC Distribution Board
-
-
-
... More
DCDB
Supply & installation of DC combiner box/Array Junction Box made out of the thermoplastic IP65 protected DIN rail mounting type of following size for interconnection of DC cable of the solar module arrays & DC outgoing cable to DC distribution box complete with termination with cu lugs/ferrule /connectors (MC4) and fixing accessories as required.
Outdoor IP 65 Enclosure – 560mm X 380mm X 130mm Input Postive & Negative Fuse 15A – – 3 nos
Solar Output Terminal Block – – 3 nos
SPD DC SPD 1000V 40KA type 2 – – 3 nos
Input & Output PG Gland – 7 Nos
3
-
-
... More
ACDB
Supply & installation of AC distribution box made out of the thermoplastic IP65 protected DIN rail mounting and front lid transparent type of following size with Phase indication LED lamp, busbar, earth link terminal etc. complete with all fixing accessories as required.
Metal Enclosure 600*400*180 MM Metal Box With IP 65 Rating
ABB MCCB 100A FP 10KA Spreder 100A FP,
Phonix SPD 4 Pole
Metal Gland Etc
Spreder 100A FP,
Busbar Supportor 100A
RYB Indicator Reputed Make
Copper Cable Flexible 25Sq.mm Connectwell terminal Block
Earthing Termianl Green & Yellow Color
Double Compression Gland (Brass)
Standard Indicating Sticker
3
-
-
... More
Multi function Meter : Instantaneous RMS values
Current: Average line current of 3-phase, per-phase, and calculated neutral current
Voltage: Average voltage of L-L, L-N parameters, and per-phase
Frequency Any available line: Real, reactive, and apparent power, Total and per-phase value, Displacement power factor, Average and per-phase signed, four-quadrant
True power factor, Average and per-phase signed, four-quadrant
Demand values
Current average: Present, Last, Predicted, Peak, and Peak Date Time
Active power: Present, Last, Predicted, Peak, and Peak Date Time
Reactive power: Present, Last, Predicted, Peak, and Peak Date Time
Apparent power: Present, Last, Predicted, Peak, and Peak Date Time
Demand sync methods: Thermal, Timed, Command Sync, and Clocked Sync
Demand calculation mode: Sliding, fixed and rolling block
-
-
-
... More
Civil Work Required for fixing HDGI structure for 70 KW, 50 W & 30 KW PV Module (BoQ Item No 18.00, 19.00 & 20.00 )
Supply, installation of concrete blocks in adequate Nos of Minimum of M20 Grade Size LXBXH (300mmX300mmx300mm) or (300mmx300mmx600mm) as directed by Engr-in-charge with All the Accessories including formwork and all accessories required including Hardware for complete instalation.
Foundation Tapering Foundation Finishing
Cubical concrete block size 300mmx300mmx600mm for column height more than 3 m Cubical concrete block size 300mmx300mmx300mm for column height less than 3 m
1
-
-
... More
NOTE:
1 Bidders are hereby advised to visit the project site for checking feasibility & design of solar pv panel installation before offering.
2 Contractor shall have to submit the Shop drawing with Layout out plan and SLD for each Tower to Engr-in-Charge for approval of GE before commencement of the work.
3 Contractor shall have to submit Design calculation for structure with stud analysis to Engr-in-Charge for approval of GE before commencement of the work.
4 Contractor shall have to provide Test certificate of Invertor, solar pv module, Manuals maintenance to Engr-in-Charge during execution of the work.
5. Contrcator shall have to provide the training sessions to department staff for routine exercise and mantenance. 6 Contractor shall have to submit as built drawing to Engr-in-Charge for safe custody after completion of work.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%