If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 28,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Ge I R And D/chd-73/2024-25 Repair And Periodical Maintenance Of Fire Alarm/fire Fightings System And Connected Works In Otm Accn At Chandigarh And Tbrl Range Ramgarh
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679884_1Bid Award Id
ViewTender No
GE I R AND D/CHD-73/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply only response indicator LED type complete all as specified and directed.
15
-
-
Supply only wall mounted fire alarm manual call point conventional type complete all as specified and directed.
14
-
-
Supply only fire alarm hooter for conventional fire alarm system operated on 100V AC/ 24V DC with suitable audible range 80DB complete all as specified and directed.
15
-
-
Supply only lead acid battery 12 volts 7 AH suitable for conventional fire alarm panel complete all as specified and directed.
6
-
-
Supply only fire alarm panel of 04 zones with LCD display facility and advanced micro controller based circuit complete all as specified and directed.
2
-
-
Supply only FRLS flexible copper cable 1.5 sqm, 2 core , 1100 volts grade complete all as specified and directed.
200
-
-
Supply only FRLS flexible copper cable 2.5 sqm, 2 core , 1100 volts grade complete all as specified and directed.
100
-
-
Taking down fire extinguisher cylinder from the fire stand/wall and refilling of gas cylinder with multi purpose dry powder suitable for class ABC, cylinder capacity 6 kg including hydraulic pressure testing of cylinder complete all as specified and directed.
6
-
-
Taking down fire extinguisher cylinder from the fire stand/wall and refilling of gas cylinder with multi purpose dry powder suitable for class ABC, cylinder capacity 9 kg including hydraulic pressure testing of cylinder complete all as specified and directed..
7
-
-
Supply and fixing for portable fire extinguisher cylinder filled with mono ammonium phosphate dry powder MAP90 suitable for all types of fire class A,B, C and bulk range discharge two metre minimum and capacity 06 kg ISI marked complete all as specified and as directed.
5
-
-
Supply and fixing for portable fire extinguisher cylinder filled with mono ammonium phosphate dry powder MAP90 suitable for all types of fire class A,B, C and bulk range discharge two metre minimum and capacity 09 kg ISI marked complete all as specified and as directed.
5
-
-
Supply and replacement of fire bucket made of 24 gauge steel sheet, capacity 9 ltr complete all as specified and as directed..
5
-
-
Supply and fixing in replacement amplifier SSB - 80 DFM with USB,SD card, bluetooth , power output 110W max, input channel 3x mic 1.0mV, 1x Aux 100mV,speaker output 4 ohm, 8 ohm, 16 ohm, 70V and 100V,suitable for input 220V and 50Hz complete all as specified and as directed.
1
-
-
Supply and fixing in replacement wall mounted speaker 6 watt of PA system complete all as specified and as directed.
3
-
-
Supply and fixing in replacement wall mounted speaker 10 watt of PA system complete all as specified and as directed.
2
-
-
SECTION - II (RAMGARH AREA )
Testing / servicing / comprehensive maintenance and repair including renewal/ replacement of defective parts of all existing fire protection system complete of following fire protection system installed at various location in TBRL Range Ramgarh once in a month for 100% serviceability of the complete including checking of fire detectors, cleaning of detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of batteries, specific gravity of electrolyte, wiring connection of detectors/hooter/response indicator and the alarm function of control panel and indicating equipment be checked by the operation of trigger device of the fire alarm system installed in the following buildings at TBRL Range Ramgarh and replacing the defective / unserviceable parts complete all as specified and directed.
NOTE:- (i) Cost of new components/parts shall be paid for separately under relevant item of schedule 'A' Sec ll item 50 to 64.
(ii) Contractor's rep will visit minimum once in a month to every panel and take serviceability certificate duly signed by the users. Additional visit as and when required will not be paid as extra.
Fire alarm panel of 06 zone in library section Dec Bldg.
9
-
-
Fire Alarm panels of 04 zones in directorate bldg zone-1 complete all as specified and as directed.
9
-
-
Fire alarm panels of 04 zones in telephone exchange bldg Zone-I complete all as specified and as directed.
9
-
-
Fire alarm panel of 06 zones in J-2 bldg zone-I complete all as specified and as directed.
9
-
-
Fire alarm panel of 06 zones in auditorium bldg zone-I complete all as specified and as directed.
9
-
-
Fire alarm panel of 04 zones in VAJRA bldg zone-I complete all as specified and as directed.
9
-
-
FireaAlarm panel of 04 zones in B-15 bldg zone - III complete all as specified and as directed.
9
-
-
Fire alarm panel of 04 zones in data analysis centre zone - III complete all as specified and as directed.
9
-
-
Fire alarm panel of 02 zones in contro room zone – VI complete all as specified and as directed.
9
-
-
Fire alarm panel of 04 zones in block house zone – VII complete all as specified and as directed.
9
-
-
Fire alarm panel of 04 zones in HMX plant bldg zone-II complete all as specified and as directed.
9
-
-
Fire alarm panel of 02 zones in PBX bldg zone-II complete all as specified and as directed.
9
-
-
Fire alarm panel of 06 zones in octal plant bldg Zone-II complete all as specified and as directed.
9
-
-
Fire alarm panel addressable type at ETF Zone in ESS test facility complete all as specified and as directed.
9
-
-
Fire alarm panel addressable type at ETF Zone in EMI test facility complete all as specified and as directed.
9
-
-
Fire alarm panel addressable type at SWS AAG zone CADS bldg complete all as specified and as directed.
9
-
-
Fire alarm panel addressable type at zone IV in pulse Radiography bldg complete all as specified and as directed..
9
-
-
Supply only fire alarm panel of 06 zones with LCD display facility and advanced micro controller based circuit complete all as specified and directed.
2
-
-
Supply only fire alarm panel of 04 zones with LCD display facility and advanced micro controller based circuit complete all as specified and directed.
2
-
-
Supply only fire alarm panel of 02 zones with LCD display facility and advanced micro controller based circuit complete all as specified and directed.
2
-
-
Supply only FRLS flexible copper cable 1.5 sqm, 2 core , 1100 volts grade complete all as specified and directed.
150
-
-
Supply only FRLS flexible copper cable 2.5 sqm, 2 core , 1100 volts grade complete all as specified and directed.
100
-
-
Supply only smoke detector conventional type (ceiling mounted) with base, ionization type dual chamber as per approved specification. The smoke detector should be match able with existing system in the building complete all as specified and directed.
90
-
-
Supply, only heat detector conventional type with base ionization type dual chamber as per approved specification. The heat detector should be match able with existing system in the building complete all as specified and directed.
25
-
-
Suppply only response indicator LED type complete all as specified and directed.
18
-
-
Supply only wall mounted fire alarm manual call point conventional type complete all as specified and directed.
22
-
-
Supply only fire alarm hooter for conventional fire alarm system operated on 100V AC/ 24V DC with suitable audible range 80DB complete all as specified and directed.
15
-
-
Supply only lead acid battery 12 volts 7 AH suitable for conventional fire alarm panel complete all as specified and directed.
10
-
-
Taking down fire extinguisher cylinder from the fire stand/wall and refilling of gas cylinder with multipurpose dry powder suitable for class ABC, cylinder capacity 2 kg including hydraulic pressure testing of cylinder complete all as specified and directed.
10
-
-
Taking down fire extinguisher cylinder from the fire stand/wall and refilling of gas cylinder with multipurpose dry powder suitable for class ABC, cylinder capacity 6 kg including hydraulic pressure testing of cylinder complete all as specified and directed.
10
-
-
Taking down fire extinguisher cylinder from the fire stand/wall and refilling of gas cylinder with multipurpose dry powder suitable for class ABC, cylinder capacity 9 kg including hydraulic pressure testing of cylinder complete all as specified and directed.
10
-
-
Taking down carefully old unserviceable sub main wiring complete all as specified and directed.
130
-
-
Material and labor for sub main wiring with two runs of single core, PVC insulated, unsheathed ,multi standard copper conductor cable of size 1.5 sqm, 1100 volts grade and one run of 1.5 sqm PVC insulated earth continuity copper conductor cable drawn through and including suitable size of PVC concealed conduit with all necessary accessories such as bends, tees, junctions boxes, elbows etc. complete with all in coming and outgoing cable connections complete all as specified and as directed. (Note : Two runs of 1.5 sqm cable, one run of 1.5 sqm continuity earth wire and one run of PVC conduit with all necessary accessories will be measured as unit length).
130
-
-
Supply and fixing for portable fire extinguisher cylinder filled with mono ammonium phosphate dry powder MAP90 suitable for all types of fire class A,B, C and bulk range discharge two metre minimum and capacity 02 kg ISI marked complete all as specified and as directed.
4
-
-
Supply and fixing for portable fire extinguisher cylinder filled with mono ammonium phosphate dry powder MAP90 suitable for all types of fire class A,B, C and bulk range discharge two metre minimum and capacity 06 kg ISI marked complete all as specified and as directed.
5
-
-
Supply and fixing for portable fire extinguisher cylinder filled with mono ammonium phosphate dry powder MAP90 suitable for all types of fire class A,B, C and bulk range discharge two metre minimum and capacity 09 kg ISI marked complete all as specified and as directed.
5
-
-
Supply only smoke detector addressable type (ceiling mounted) with base, ionization type dual chamber as per approved specification. The smoke detector should be match able with existing system in the building complete all as specified and directed.
10
-
-
Supply, only heat detector addressable type with base ionization type dual chamber as per approved specification. The heat detector should be match able with existing system in the building complete all as specified and directed.
7
-
-
Supply only wall mounted fire alarm manual call point addressable type complete all as specified and directed.
6
-
-
Supply only fire alarm hooter for addressable fire alarm system operated on 100V AC/ 24V DC with suitable audible range 80DB complete all as specified and directed.
5
-
-