Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date16 Feb 2024
Closing Date9 Mar 2024
Tender Amount₹ 20,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
item No. 03 (contd....) Specifications (a) Capacity - 30 Kg (Minimum) (b) Basket Volume - 613 Ltr (Minimum) (c) Basket diameter - 970 mm (Minimum) (d) Basket depth – 830 mm (Minimum) (e) Door opening diameter - 750 mm (f) Drive Motor capacity – 1 HP (g) Exhaust Motor capacity – 1 HP (h) Steam inlet – 1 Inches (i) Condensate outlet – 1 Inches (j) Hot air outlet size 150 mmX200 mm (k) Heater – 24 KW

-

-

-

... More
Notes :- For item No. 1 & 3. Quoted rates includes the following (a) PCC foundations and grouting arrangements as recommended by the OEM. (b) Complete installation, electrical and mechanical connecting as recommended by OEM, including testing in front of Eng-in-charge and accepting officer. (c) Connection from wall to machine including one PP-R valve for each machine and should make arrangements for drain outlet as per site requirement as directed by the Eng-in-charge. (i) Contractor shall provide one year warranty after completion of work including replacement of defective parts during maintenance period. (ii) Contractor shall also teach operation of machines to the user rep.

-

-

-

... More
Supply and fixing industrial type plug and socket set three, phase and neutral, 05 Pin, 63 Amps, 415 V, including top and 63 Amp,, TPN MCB, 10 KA breaking capacity ‘C’ curve complete all as specified and as directed by the Engr-in-charge. Make : L & T /Seimens/Schneider

4

-

-

... More
S & laying as in repair sub main wiring with four run of 16 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 16 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Five runs of cable and one run of PVC conduit shall be measured and paid as one unit length.

43

-

-

... More
Material & labour earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron strip earth lead of 25x 4mm thick size by means of bolts, nuts, check nuts and washers of galvanised iron, earth strip protected by GI pipe 32mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . Note :- Cost of GI strip 25x4 mm thick upto 7.5 mtr length shall be includied in the quoted rate.

10

-

-

... More
Supply and fixing sheet metal enclosure Vertical triple pole & neutral(VTPN), 415 volts, 4 way with 200 Amp rated bus bar, IP 54 protection, double door, with and including MCCB 4 Pole, 160 Amp, 415 Volts, breaking capacity 25 KA ,Adjustable Thermal Range as incomer, flush /surface mounting duly grouted in wall or on wooden board with lugs/thimbles duly crimped for connection complete all as specified and as directed by the Engr-in-charge. Make : L&T/Schneider/Seimens

1

-

-

... More
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable 50 sqmm cross sectional area, 3.5 core with aluminium conductor, 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.

58

-

-

... More
Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in soft/loose soil, complete all as specified and as directed .

12.15

-

-

... More
Supply and lay GI tubing light grade with connected fittings 32mm dia for cable protection and fixed with clamp to pole and wall with nut bolts complete all as specified and as directed by Engineer-in-Charge

12

-

-

... More
Material and Labour for Fine and dry sand cushioning for underground cable by providing a layers of sand 8cm deep before laying and 15cm deep after laying the cable including stretching the cable, complete all as specified and as directed . Note - Punned thickness of sand layer shall be measured and paid to contractor.

3.65

-

-

... More
Supply and laying well burnt brick class-B laid flat to cover the cable width equal to the length of cable and abutting each other for protection of cable complete all as specified and as directed by Engineer-in-Charge.

0.39

-

-

... More
Returning, filling in, including spreading, levelling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.

7

-

-

... More
Removing surplus excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.

5.15

-

-

... More
M& L for cutting the existing hard standing/PCC/WBM road depth exceeding 45 cm and 30 cm in width for passing of cable through GI pipe and making good the disturbed surface with PCC (1:3:6) type C-1 using 20mm graded stone aggregate complete all as specified and directed.

0.2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.