Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679925_2Tender No
GE/SRA/T-50/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
-ditto- but using 4.0 sqmm FRLSH wire for both mains and earth wire in and including 19/20 mm Rigid Metallic ERW conduit complete
2
-
-
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, fixed/laid in existing steel conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed.
(NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
36
-
-
All as per item No. 06 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
8
-
-
All as per item No. 06 above but using 4.0 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 4.0 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
6
-
-
S&F Flame Proof Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable along with the Wiring drawn in ERW/GI CONDUIT including taking down existing sub main wiring complete all as specified and directed. (NOTE: Conduit shall be measured and paid separately)
20
-
-
S&F Flame Proof Sub-main Wiring with 2-Runs of 10.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 10.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable along with the Wiring drawn in ERW/GI CONDUIT including taking down existing sub main wiring complete all as specified and directed. (NOTE: Conduit shall be measured and paid separately)
20
-
-
S&F in repair concealed ERW Conduit of size 25mm dia, ISI marked, heavy duty with all Conduit Accessories including cutting chases, filling the chases with cement mortar 1:6 after fixing of pipes and Making Good Surfaces to match the Exiting Treatment (as per Site requirement) , complete all as per specified and as directed.
(NOTE: Quoted rate shall be deemed to include cost of cutting chases for concealed wiring and making good as per existing specifications. No claim in this regard shall be entertained at a later stage)
20
-
-
S&F in repair concealed ERW Conduit of size 32mm dia, ISI marked, heavy duty with all Conduit Accessories including cutting chases, filling the chases with cement mortar 1:6 after fixing of pipes and Making Good Surfaces to match the Exiting Treatment (as per Site requirement) , complete all as per specified and as directed.
(NOTE: Quoted rate shall be deemed to include cost of cutting chases for concealed wiring and making good as per existing specifications. No claim in this regard shall be entertained at a later stage)
25
-
-
S&F in repair surface mounted ERW Conduit of size 19/20mm dia, ISI marked, heavy duty with all Conduit Accessories complete all as per specified and as directed.
20
-
-
S&F in repair surface mounted ERW Conduit of size 25mm dia, ISI marked, heavy duty with all Conduit Accessories complete all as per specified and as directed.
20
-
-
S&F in repair surface mounted ERW Conduit of size 32mm dia, ISI marked, heavy duty with all Conduit Accessories complete all as per specified and as directed.
15
-
-
S&F Switch Flame Proof Rotary type with Termination Box in LM6, 16 Amp, Single Pole, 250 Volts complete all as specified and as directed.
10
-
-
S&F Flame Proof, Weather Proof Switch Socket with Plug Combined in high pressure die cast aluminium alloy LM6 Termination Box, 16 Amp, 250 Volt, 2 Pin and Earth Plug, Fully Interlocked, suitable for installation in hazardous areas as per IS-2147/62, Degree of Protection IP 65 and Certified from CIMFR DHANBAD & CCOE NAGPUR, BS, duly ISI marked and complete all as specified and as directed.
8
-
-
S&F Flame Proof, Weather Proof Switch Socket with Plug Combined in high pressure die cast aluminium alloy LM6 Termination box, 25 Amp, 415 Volt, TPN, 3 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous area as per IS-2147/ 62, Degree of Protection IP 65 and Certified from CIMFR DHANBAD & CCOE NAGPUR, BS, duly ISI marked and complete all as specified and as directed.
8
-
-
Taking down and Re-fixing of serviceable tube light fitting, any type, after minor repairs including necessary electric connection & testing complete all as specified and directed.
(NOTE: Quote rate shall be deemed to be inclusive of minor spares/parts, driver, PCB, wires etc. New Tube rod, if required, shall be paid seperately as "Supply Only")
4
-
-
Supply only LED tube light 20 watt complete all as specified and as directed.
4
-
-
S&F in repairs Flame Proof LED Tube Light Fitting 2x20 Watt (4 Feet), CIMFR & PESO certified, recommended for gas/vapour group IIA & IIIB, Zone 1 & 2 and IP 65 grade protection with die cast aluminium housing, heat resistant toughened glass with & including LED tube light and fixtures, driver, holder, connector complete with all accessories, prewired and including connecting up with three core flexingle copper wire of suitable size complete all as specified and as directed.
10
-
-
S&F in repairs Flame Proof LED Tube Light Fitting 1x20 Watt (4 Feet), CIMFR & PESO certified, recommended for gas/vapour group IIA & IIIB, Zone 1 & 2 and IP 65 grade protection with die cast aluminium housing, heat resistant toughened glass with & including LED tube light and fixtures, driver, holder, connector complete with all accessories, prewired and including connecting up with three core flexingle copper wire of suitable size complete all as specified and as directed.
8
-
-
S&F in repairs LED Flameproof Flood Light fitting, 120 Watt capacity, CIMFR & PESO Certified for gas group IIC, Zone 1 & 2 with high powered LED in SMD arrangement, in high pressure die cast aluminium housing, epoxy powder coated finish with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver and heat resistant clear Type-A toughened glass cover, cable entry M20 (02 Nos) with gland & plug, IP66 grade ingress protection suitable for operating voltage 140V-270V AC, 50 Hz complete all as specified and directed and complying with the following specifications:-.
(a) system efficacy more than 100 lumen/watt
(b) CRI 80, (c) THD 10%
(d) Power factor not less than 0.95
(e) having 10 KV surge protection (f) colour temperature between 6000-6500 degree K
(g) Earthing 01 No Internal & 02 Nos External
(NOTES: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work..
(2) Wires for electric connection, if replaced shall be measured and paid separately)
5
-
-
-ditto- but for Flameproof flood light fitting of 30 Watt capacity
10
-
-
S&F in repairs PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 2.50 sqmm, 3 core,1100 Volt, conforming to IS 694 for connection of flood light fittings complete all as specified and directed
100
-
-
S&F in repair MCB Single Pole, 6 to 32 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and directed
30
-
-
S&F in repair MCB Single Pole & Neutral, 32 Amp, 240 Volt, AC, 'C' Series for fixing on MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and as directed.
5
-
-
Dismantling of flameproof DB, any type or capacity, alongwith all accessories viz MCCB, MCB etc, removing all burnt wiring, plugs, socket, MCBs, bus bars, switches, etc and all other connected accessories, properly cleaning and re-fixing the parts, accessories and switchgears with new wiring & connections and installing the DB with proper fasteners/allen key nuts and other required fixing arrangements and testing complete all as specified and directed. NOTE: Defective Switchgears i.e. MCCB & MCB shall be measured and paid seperately under respective items. Quoted rate shall be deemed to be inclusive of the cost of all other accessories such as selector switches, wires, etc. No claim shall be entertained during currency of work.
20
-
-
S&F in repair Weather proof & flame proof DB, SPN , 08 Way, in cast alumnium alloy LM6 construction, provided with 200 Amps neutral & earth link bars and wiring upto terminals. IP 65 grade protection, CIMFR DHANBAD & CCOE NAGPUR approved for Gas Group IIA, IIB & IIC and Elecrically Connecting up & testing complete all as specified and as directed and along with the following accessories :-
(i) Incomer:- MCB SPN, 63 Amps, 240 Volt, AC, 'C' Series, 10 kA - 01 No
(iii) Outgoing:- MCB SP, 40 Amps, 240 Volt, AC, 'C' Series, 10 kA - 06 No
NOTE: Quoted rate shall be deemed to be inclusive of the cost of MCBs.
2
-
-
S&F in repair MCCB, 4 pole, 125 Amps, 25 kA, Ics=100% of Icu, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in existing DB complete all as specified and directed.
4
-
-
Dismantling unserviceale LT Panel Board (of any size) from existing location including breaking of foundation and removal from site and Supply, installation , testing and commissioning of new LT Panel outdoor type confirming to IS 8623 Part I (one), fabricated in a CPRI approved factory, totally enclosed vermin proof suitably ventilated for 3 phase , 4 wire 415 Volts, 50Hz, AC supply, outer shell shall be made out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame , factory fabricated , compartmentalized inner shell shall be made of out of 2.0 mm thick CRCA sheet for control gear. Front and back door opening with locking arrangement at front. Protection of enclosure IP 56 as per IS-2147 of 1962 with pre- treatment through 7 tank hot chemical process prior to powder coating and powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size , the required no of holes to be fixed with chromium plated brass cable glands of suitable size for entry and exit. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided . EPDM gasket of appropriate shape and size provided at all joints, doors and covers including suitable size angle iron/flat iron frame work / support required with four legs 60 cm long using angle iron 40x40x6mm , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, legs grouted in PCC 1:2:4 type B1 foundation and making good disturbed surface complete and comprising of the following :-
2
-
-
Item No 30 (Contd...)
A) (i) TPN Copper electrolytic grade bus bar of capacity 200 Amps for phases & 150 Amps for neutral.and auxillary busbar to support main busbar. duly supported on SMC/DMC, busbar supports and insulated with colour coded heat shrinkable sleeve. (ii) Digital multifunction meter (V,A,KW,KWH), 415V AC alongwith C.T’s of suitable ratio (set of three), class 1.0 (iii) Indication lamps LED type (RYB) = 01 Set of three. (iv) CTs 500/5A class 1.0,15VA (Cast Resin) - 03 Nos.
(v) Internal wiring with suitable size of FRLSH copper conductor cable. B) INCOMER: (i) MCCB 100 Amps 4 pole, 16 kA, with adjustable thermal and magnetic release - 01 Nos C) OUTGOING:- (ii) MCCB 63 Amp 4 Pole, 16 KA, with adjustable thermal and magnetic release - 02 Nos (i) MCB 40 Amps TPN, 10 KA, 'C' Curve - 02 Nos NOTES:-
(i) Contractor shall submit IP Test Report and verification of short circuit withstand test report issued by CPRI in respect of LT Panel Fabricator. (ii) Contractor shall submit drawing for approval prior to place order. (iii) Make of accessories shall be as specified in tender. (iv) Cost of PCC foundation shall be deemed to be inclusive in the quoted rate.
-
-
-
M&L for dismantling/taking out old unserviceable Chemical/ Normal earthing pit with all accessories after disconnection of earth strips including necessary earthwork as required complete all as specified and as directed.
17
-
-
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (up to 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
5
-
-
Supply, installation, testing and commissioning of maintenance free chemical earthing station using 17.2 mm dia, 3000 mm long high tensile low carbon steel circular rod, molecularly bonded with copper on outer surface (minimum copper bonding thickness of 250 microns) meeting the requirements of Underwriters Laboratories (UL) 467-2007 or latest, with 250 mm long copper strip of size 50 x 6 mm, exothermally welded on top of electrode complete including augering (boring) 100-125 mm dia hole as required for electrode in any type of soil and back filling with carbon based ground enhancing compound (GEC) compound (with minimum qty 75 Kg per electrode) conforming to IEEE/BS standards complete all as specified and directed.
(NOTES :- (1) The acceptable earth resistance at earth bus bar/test point shall not be more than 01 Ohm. At certain locations, it may not be possible to achieve earth resistance of 01 Ohm with one electrode/pit due to higher soil resistivity. In such cases, provision of loop earthing consisting of more than one earth electrode pits shall be done. The number of pits required shall be decided based on the resistivity of soil and resistance achieved for the earth pits already installed. The distance between two successive earth electrodes shall not be less than 3 metres. The procedure mentioned below for one earth pit shall be repeated for other earth pits. Additional earth electrode pits and loop conductor shall be measured and paid separately under respective items.
(2) Bore dia of earthing should be minimum 200mm. (3) Cost of Ground Enhancing Compound is deemed to be included in the quoted rate. FRP Earth pit cover shall be measured and paid seperately.
12
-
-
S&F in repair Earth Pit 125mm dia with FRP Earth Pit Cover of top size 200x200mm bottom size 300x300mm with height of 150mm with lockable Lid, Earth Pit cover shall be made of Poly plastic tested at 7.5 ton load for closing of earth pits complete all as specified and as directed.
12
-
-
S&F in repairs copper strip 20 mm X 3.15 mm with saddles and fixing screws etc, for roof conductors and down conductors above ground including provn of porcelain insulator @ 1.0 m spacing complete all as specified and directed.
Note: Cost of Screws, Saddles, insulator, Nuts and Bolts, etc. will deemed to be included in the Quoted Unit Rate.
300
-
-
S&F in repairs Aluminium strip 25x3.15 mm with saddles and fixing screws for roof/earth conductor and down conductors above ground including provn of porcelain insulator @ 1.0 m spacing complete all as specified and directed.
Note: Cost of Screws, Saddles, insulator, Nuts and Bolts, etc. will deemed to be included in the Quoted Unit Rate.
100
-
-
S&F in repairs galvanised iron tubing/pipe, 40 mm bore, light grade for fixing of termination rods or for protection of earth strips, fixed on walls/floors/pole with suitable type of clamps, etc complete all as specified and as directed
50
-
-
S&F in repairs galvanised iron tubing/pipe, 25 mm bore, light grade for fixing of termination rods or for protection of earth strips, fixed on walls/floors/pole with suitable type of clamps, etc complete all as specified and as directed
70
-
-
S&F in repairs test point terminal block made of gun metal or phosphorous bronze size 75x75x25mm, drilled and screwed including 3 No. 8 mm dia, 25 mm long hexagonal head screw, complete all as specified and as directed
5
-
-
S&F in repairs air termination single pointed copper rod 20 mm dia with brass base and 300 mm long with arrester clamp 16 mm made out of brass, duly fixed on GI pipes with PCC base complete all as specified and as directed.
Note: PCC and GI pipe for fixing of termination rod shall be measured and paid seperately.
15
-
-
M&L Cement Concrete 1:2:4 type B1 (20mm graded stone aggregate) as in base of air termination rods, Coping of Electric Poles, etc. including weathering, slightly rounded or chamfered angle and throating, all exposed faces of Concrete finished even and smooth including necessary formwork complete all as specified and directed.
1
-
-
M&L Cement Concrete 1:3:6 type C1 (20mm graded stone aggregate) as in benching, etc including weathering, slightly chamfered angles, exposed surfaces finished even and smooth including necessary formwork complete all as specified and directed.
1
-
-
M&L Load Testing of flame proof/non flame proof EOT Crane up to 6 Ton, Load capacity to prove the satisfactory Operation of Electrical Controls, Motors, Gear Boxes, Protective Devices, system Interlocks and Mechanical components like Wire Rope, Weld Sections check/welding to existing Channel of the Crane in all Motions (LT CT Hoist in High Speed and Creep Speed) during Full Load and testing of Crane in Over Load at 100 + 25% in presence of Representative of AF Sirsa including all Consumables Items, complete all as specified and as directed by Engineer-in-Charge.
NOTES :-
(1) (a) Load Blocks in denomination of total tonnage of crane + 25% in required quantity shall be provided by the Contractor under his own Arrangement and Cost including shifting of these Blocks near to the Crane Load required for lower denomination for which Contractor has no Extra Claim. Cost of Transportation and Handling Charges are also deemed to be included in the Quoted Unit Rate.
(b) Load Tests are to be carried out by the Contractor minimum ½ to 1.0 Hour duration though an OEM Certified Technician in presence of Department Representative and will record the Test.
(c) Contractor will be responsible for Servicing of Crane before Load Testing. Cost of all Consumable Items will be deem to be included in the Quoted Unit Rate including Brake Oil, Gear Oil and Grease etc.
35
-
-
Item No 43 (Contd...)
(d) Deflection Test of EOT Crane should be done by any OEM certified agency or technician and permissible test result should be submitted by the contractor of each crane. (e) Contractor will submit all the possible test certificate duly signed by user/AF authorities, provided by EOT crane expert /firm/company to the department after each Crane testing.
(2) Existing Make of EOT Cranes are Rockwell/ Tib Udhyog or as per site available. (3) Contractor will change/top up Gear oil of cranes and hydraulic oil for thrusters during the repair of Cranes (4) Contractor will do hot dip galvanization process to avoid metal to metal contact of some important parts like wheels, hook, rope drums etc.
(5) Cost of all type tests/Gear oil/hydraulic oil/galvanization process, will be treated as EACH JOB only and cost will be included in quoted rates by contractor.
(6) Major parts required to be replaced shall be measured seperately under respective items. Quoted rate shall be deemed to be inclusive of the cost of other petty spares and cosumables.
-
-
-
S&F in repair Contactor 3 Pole suitable for 5 to 24 Volt, DC 40 Amp, complete all as specified and directed by Engineer-in-Charge.
6
-
-
S&F in repair Heavy duty Limit Switch with 2NO + 2NC, complete all as specified and as directed by Engineer-in-Charge.
50
-
-
S&F in repair Normally Closed/ Normally Open Switch, complete all as specified and as directed by Engineer-in-Charge.
55
-
-
S&F in repair Push Button in Yellow/Blue Colour, complete all as specified and as directed by Engineer-in-Charge.
110
-
-
S&F in repair PCB Card complete all as specified and as directed by Engineer-in-Charge.
4
-
-
S&F in repairs Electro Hydraulic Thruster Brake with 18 KG/ST 520 Thruster, Thruster Stroke 51mm, cast iron body (heavy duty), suitable for EOT Crane/Oherhead Crane upto 3 Tonne capacity complete all as specified and directed.
4
-
-
S&F in repair PVC insulated, sheathed, stranded Copper Conductor Cable of size 1.5 Sqmm, 12 Core, 1100 Volt grade, heavy duty, complete all as specified and as directed by Engineer-in-Charge.
15
-
-
S&F in repair Thermal Over Load Relay of setting range 32 Amp, 415 Volt, 50 Hz, complete all as specified and as directed by Engineer-in-Charge.
15
-
-
S&F in repair Transformer 3 Phase 50 VA (as approved as per existing one) having conversion capacity of 3 Phase 380 Volt, 400 Volt & 415 Volt to 110 Volt, 30 Volt, 24 Volt & 12 Volt complete all as specified and directed by Engineer-in-Charge.
8
-
-
S&F in repairs Wire Rope maximum 15mm dia, multi-stranded of existing Shape and Size, properly fixed and tested complete all as specified and directed by Engineer-in-Charge.
60
-
-
S&F in repair flameproof crane pulley, as per existing size and type complete, properly fixed and tested complete all as specified and as directed by Engineer-in-Charge.
10
-
-
Dismantling of unserviceable control motor from EOT Crane, any capacity or from any height, transporting of motor to workshop outside AF premises for repairing, rewinding with suitable size copper winding wire, replacing any other unserviceable parts, shifting to site after repairs, re-installation at site and tesing for satisfactory operation of motor and EOT Crane complete all as specified and directed.
NOTE: Cost of to & fro transportaion, workshop charges, all parts/spares of motor including copper winding wire shall be deemed to be included in the quoted rates.
8
-
-
M&L for Realignment of Crane Rail Track including removing of Rail and replacing the damaged and perished Rubber Padding wherever and replacing the worn out Bolts, Nuts and Washers including welding new Mild Steel Clamps wherever necessary and checking of Bends straightening and refixing the Rails including Provision of necessary Packing Shoes and ensure Proper Alignment including necessary Welding Works at Corners, etc., complete all as specified and as directed by Engineer-in-Charge.
(NOTE:- Cost of spares/parts shall be deemed to be included in the quoted rate)
10
-
-
S&F in repairs power contactor coil 240/415 V, AC, Amp rating MCX 32-34 complete all as specified and directed
3
-
-
S&F in repairs GI wire conductor 4 mm dia lead fixed to wall and iron girder with fixtures and fittings, clamps, nuts & bolts or in any other indicated situation for loop earthing complete all as specified and directed.
110
-
-
S&F in repairs EOT Crane industrial cable carrier trolley (flame resistant), suitable for any type of Overhead EOT Crane complete all as specified and directed.
(NOTE: Make shall be as per OEM)
150
-
-
S&F in repairs EOT Crane pendent cable round type of size 4 sqmm x 4 core complete with CEI 20-2022 to II (flame resistant), suitable for any type of Overhead EOT Crane complete all as specified and directed.
(NOTE: Make of cable shall be as per OEM)
160
-
-
Excavation in trenches (manually) not exc 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soil all as specified and directed.
(NOTE:- Mechanical excavation shall not be allowed)
127
-
-
Returning filling including spreading levelling watering and well ramming in layers n.exc 25 cm in soil completed all as specified and directed.
75
-
-
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified and directed.
72
-
-
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) up to 180mm thickness, complete all as specified and as directed.
NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
27
-
-
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, laid perpendicular to the cable for Cable Protection, complete all as specified and as directed.
500
-
-
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
380
-
-
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing incl taking down/up unserviceable LT cable incl necessary disconnection for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete of the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
-
-
-
10 Sqmm, 2 core
3300
-
-
35 Sqmm, 3.5 core
90
-
-
M&L for painting to external surfaces of HT/LT Panels, any size with a coat of synthetic enamel paint, of approved shade, duly spray painted after properly cleaning and preaparing old surfaces complete all as specified and directed.
(NOTE: Painting work shall be carried out only after disconnecting the main electric lines to avoid any mishap. Proper precautions shall be taken to avoid any spill or damage to the switchgears. if any rusted surface or patch is observed, the same shall be properly cleaned and treated with red oxide primer before application of paint. Cost of the same shall be deemed to be included in the quoted rates.
4
-
-
-ditto- but for HT/LT Feeder Pillars of comparatively smaller size
4
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past