If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696960_1Tender No
GE/GUR-/NIT-67/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(a) 200 mm bore
30
-
-
... More
(b) 150 mm bore
60
-
-
... More
(c) 100 mm bore
85
-
-
... More
Supply, laying, jointing & testing DI-K7 class with spigot and socket, suitable for Push on rubber joint, with internal cement mortor lining, and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 including Rubber Gasket & joints as per IS:9523-2000 laid in trenches/ Road/ Ducts/ Footpath/ on wall/ on floor locations for 200 mm bore dia pipe complete all as specified and directed.
30
-
-
... More
Supply, laying, jointing & testing DI-K7 class with spigot and socket, suitable for Push on rubber joint, with internal cement mortor lining, and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 including Rubber Gasket & joints as per IS:9523-2000 laid in trenches/ Road/ Ducts/ Footpath/ on wall/ on floor locations for 150 mm bore dia pipe complete all as specified and directed.
60
-
-
... More
Supply, laying, jointing & testing DI-K7 class with spigot and socket, suitable for Push on rubber joint, with internal cement mortor lining, and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 including Rubber Gasket & joints as per IS:9523-2000 laid in trenches/ Road/ Ducts/ Footpath/ on wall/ on floor locations for 100 mm bore dia pipe complete all as specified and directed.
85
-
-
... More
Taking down existing CI specials and M&L CI specials such as bends (any type,radius, tapers) and any type (straight,bend, increasing, decreasing,or double socket ect). Tee pieces single branch 'Y' junction double branch,cross (all sockets or socket and spigot), collars caps and plugs ect for upto 250mm bore as in repair including complete all as specified and directed.
260
-
-
... More
Burning out existing lead joints of CI pipes including cleaning and collecting old lead complete all as specified and directed by engineer-in-charge for the following bore Note:- Excavation and earth work required shall be measured and paid separately under relevant items.
-
-
-
... More
(a) 200 mm bore pipe
5
-
-
... More
(b) 150 mm bore pipe
10
-
-
... More
(c) 100 mm bore pipe
6
-
-
... More
M&L for run lead joints in position for spigot socket pipe and specials including provision of all jointing materials such as pig lead,lead spun yarn/joint ect for the following bore:-
-
-
-
... More
(a) 200 mm bore pipe
5
-
-
... More
(b) 150 mm bore pipe
10
-
-
... More
(c) 100 mm bore pipe
6
-
-
... More
Taking down existing sluice valve and supply and fix in position sluice valve (ISI marked) flanged and drill both ends cast iron body, heavy duty brass spindle type PN 1.0 with and including jointing rubber gasket,nut,bolts including taking out existing CI sluice valve of following sizes:-
-
-
-
... More
(a) 200 mm bore
1
-
-
... More
(b) 150 mm bore
2
-
-
... More
(c) 100 mm bore
2
-
-
... More
(d) 80 mm bore
2
-
-
... More
Taking down existing non- return valve and S&F 80 mm more CI non return valve, flanged type ISI marked with by pass arrangement all as specified and dirrected.
2
-
-
... More
M&L for PCC type 1:4:8 type D2 ( using 40mm graded aggregate) for thrust block for supporting pipe lines including necessary use all as specified and directed by engr -in- charge.
3
-
-
... More
M&L for sump/tank MS cover 60cmX60cm made out of 5 mm thick MS sheet bends to shape/with angle iron frame on sides, locking, arrangement fixed to manhole of UG sumps and RCC tanks with grouting the angle iron frame in RCC slabe including two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
3
-
-
... More
Taking down and dismantling HPSV/ LED type street light fitting for 45/ 70/150/250 watt capacity of any make/type from pole/GI pipe unserviceable items to be kept in safe custody and taken as credit complete all as specified and directed by Engineer -in-charge.
90
-
-
... More
Supply and fixing in replacement LED type street light 70 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complete all as specified and directed..
65
-
-
... More
Supply and fixing in replacement LED type flood light 100 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
15
-
-
... More
Supply and fixing in replacement LED type flood light 120 watt 230 watt volts AC outdoor type with t IP 65 class protection with aluminium die cast housing glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total lumen efficiency =80 lm/watt , THD≤ 20 CRI80 , colour temperature 6500 K, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed..
10
-
-
... More
M&L for defect rectification LTcable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc. including and additional excavation in normal alluvial strata required for exposing the cable fault, removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the hours of instruction from Engr-in-Charge as specified.
15
-
-
... More
Supply and jointing straight through cold shrink joint suitable for LT 415 Volt XLPE cable of size 70 to 120 Sq mm 3.5 core complete all as specified and as directed by Engineer-in-Charge.
8
-
-
... More
Supply and jointing straight through joint cold shrink suitable for LT 415 Volt XLPE cable of size 25 to 50 Sq mm 3.5/4 core complete all as specified and as directed by Engineer-in-Charge.
10
-
-
... More
S & F in replacement of Aluminium Cable lugs/Thimbles upto size 16 to 25 sqmm complete all as specified.
50
-
-
... More
S & F in replacement of Aluminium Cable lugs/Thimbles of size 35 to 50 sqmm complete all as specified.
50
-
-
... More
S & F in replacement of Aluminium Cable lugs/Thimbles of size 70 to 120 sqmm complete all as specified.
30
-
-
... More
Supply and fix in replacement of automatic timer switch pole mounted enclosure consisting of ON/OFF switch based on LUX level power contactor 40 Amps, 10KA 'C' series 4 pole, MCB 40 Amps, TP - 03 Nos, enclosure made of rust proof, shock proof, conforming to IP -54 complete all as specified and as directed. Make : Kakatiya/Healer/Bajaj.
Note: (i) Inlet/outlet connecting cable PVC insulated aluminium stranded conductor 6 Sqmm, 4 single core for incoming & outgoing up to 8 Mtr deemed to be included in the unit rate. (ii) Provn of glands and lugs shall be deemed to be included in the quoted rate.
12
-
-
... More
Supply, installing, testing and commissioning Altoch dosing system along with high pressure dosing pump consisting of 01 No, 100 ltrs capacity FRP tank with FRP lead. The lead shall have port hole for puring altoch and water and including one level gauge alongwith agitator (900 RPM) with shaft and blade made out of high quality plastic, mounted on tank complete including all acessories like lead tubing, connecting check valve, clay weight, required cable and ferrule comprise the follwing :-
(a) Adjustable high pressure gauge. (0-100PSI
(b) Ddosing Pump : 1/30 HP
(c) Cut out-2 US GPD to 40 US GPD
(d) Power -230V
(e) RPM-44
3
-
-
... More
Supply and testing Chloroscope testing kit for Chlorine test of portable water with Orthotolidine solution method. Note : Cost of 500 ML Orthotolidine solution included in quoted rate.
3
-
-
... More
Supply and pouring Calcium hypochlorite (Stable bleaching Powder/ High Strength Bleaching Powder), dry free flowing and free from lumps in granular form in packing of 45 Kgs HDPE Air tight drums as per specification given below:-
(a) Available chlorine - 65 % by mass, Minimum. (b) Stability - 1/15 (Loss of chloride on basis of available chloride, Maximum. (c ) Particle size (passing through 1.70 mm IS sieve) - 99.5 % by mass , Minimum. (d) Water insoluble matter - 6% Maximum. (e) Calcium Hydroxide - 4 % Maximum.. (f) Sodium Chloride - 15 %Maximum..
810
-
-
... More
Material and labour for bacteriological and chemical analysis of water sample of Govt approved lab/ISO certified lab, the water sample to be carried every month or as directed by Engr -in- charge in sterilized bottle/watercan which will be the responsibility of the contractor.Cost of testing charges including conveyance and water test certificate to be submitted in Duplicate to Engineer-in-charge. Note: sample to be collected from sump and pump house as directed by Engr -in- charge.
12
-
-
... More
Taking out unserviceable rusted steel water tubing and connection including cleaning for refixing or removal from site all as directed of the following sizes:
-
-
-
... More
(a) 20 mm bore
150
-
-
... More
(b ) 25 mm bore
140
-
-
... More
(c) 40 mm bore
230
-
-
... More
(d) 50 mm bore
110
-
-
... More
Refixing old steel tubing and connections in new or old position after cleaning including all fittings of the following size complete all as specified and directed.
-
-
-
... More
(a) 20 mm bore
15
-
-
... More
(b ) 25 mm bore
10
-
-
... More
(c) 40 mm bore
20
-
-
... More
(d) 50 mm bore
10
-
-
... More
Supply and laying in trenches/wall/floors GI tubing medium grade including all required fittings as required at site complete all as specified and directed of following sizes:
-
-
-
... More
(a) 20 mm bore
135
-
-
... More
(b ) 25 mm bore
130
-
-
... More
(c) 40 mm bore
210
-
-
... More
(d) 50 mm bore
100
-
-
... More
Dismantling carefully centrifugal/monoblock electric motor from site of installation and transportion to work shop and them removing all burnt/ worn out coils cleaning of stator slots and insertion of insulating paper in the slots of appropriate size and rewinding with supper enameled copper wire ISI marked with existing size and varnishing with two coats of insulating varnish including all winding materials for 3 phase 415 volts 50 HZ 1460 RPM of any make and model complete reinstallation of motor at site upto the entire satisfaction of Engr-in-charge for the following capacity :-
Note :- (i) Any adjustment in the pump set if required. The same shall also be carried out by the contractor without any extra payment.
(ii) Any damage to the pump set occurs due to improper installation of motor contractor shall be liable for repair.
-
-
-
... More
(a) Capacity up to 5 HP
6
-
-
... More
(a) Capacity up to 10 HP
4
-
-
... More
(c) Capacity 15 HP.
3
-
-
... More
Supply and fix in replacement Electronic Water level indicator having 10 Levels (form 1 to 10), sensor system should be with LED display with 6 Volt Battery (Rechargeable type), consisting of ON/OFF switch,suitable for 230 Volt, ISI Marked, including necessary wiring, sensor or necessary items as dircted by company manufacturer for fully functional of level indicator. Make : Surya Electronic and Controls/ RDS/
1
-
-
... More
M&L for repairs to CI mechanical joints suitable for CI/DI pipe with all accessories such as CI sleave, CI outer rings,rubber gaskets,GI bolt,nut,washer ect all as directed by Engr-in-chrage and suitable for the following size of pipes:-
-
-
-
... More
(a) 200 mm bore
4
-
-
... More
(b) 150 mm bore
6
-
-
... More
(c) 100 mm bore
8
-
-
... More
M& L for servicing of RO plant( Acqua gurad type) of capacity 15 to 40 ltrs per hour including replacement of following items :-
4
-
-
... More
i) Carbon filter
4
-
-
... More
ii) Sediment filter
4
-
-
... More
iii) Membrane
4
-
-
... More
iv) R O Pump
2
-
-
... More
(v) Complete set of Pipe (fresh Water pipe line and Waste water Pipe)
4
-
-
... More
Dismantling/Taking out of radiator assembly to work shop for cleaning with compressed air ,pointing out leaking places and soldering carefully and refix in position after making it serviceable of DG 20 to 30 KVA
2
-
-
... More
Dismantling/Taking out of radiator assembly to work shop for cleaning with compressed air ,pointing out leaking places and soldering carefully and refix in position after making it serviceable of DG 400 KVA
1
-
-
... More
Dismantling/Taking out of radiator assembly to work shop for cleaning with compressed air ,pointing out leaking places and soldering carefully and refix in position after making it serviceable of DG 500 KVA
1
-
-
... More
Supply & fixing following items in replacement of DG Set of various capacity :-
-
-
-
... More
(i). Battery terminal, lug, bolts type suitable for heavy duty battery.
8
-
-
... More
(ii) Battery leads for copper conductor multiwired 16 Sqmm. 1.5 mtrs long
10
-
-
... More
S&F V belt for fan pulley (set of 2Nos) for DG set upto 500 KVA DG Set complete all as specified.
4
-
-
... More
S&F V belt for alternator and water pump assembly for DG set upto 500 KVA complete all as specified.
4
-
-
... More
S&F Fuel hose pipe from fuel filter to fuel pump for DG set upto 500 KVA, complete all as specified.
4
-
-
... More
S&F Fuel pipe from fuel tank to fuel filter (transparent) for DG set upto 500 KVA, complete all as specified.
3
-
-
... More
S&F fuel feed pump suitable size as required on site for DG set of capacity upto 500 KVA, complete all as specified and directed.
1
-
-
... More
M&L for attending complatints of street light, flood light,high mast light mounted at any height in pole/hanger in domestic and tech area of AFS Dhansa, Narela & Indora and connected road light by checking connection , serviceability of fittings, SMC boxes , MCB, thimbles or any other minor fault complete all as specified and directed. Note- (a) Arrangement of Ladder shall be done by contractor. (b) Arrangement of hydra as and when required or any other T&P, Grese for attending complaints of Hanger light/high mast light shall be done by contractor.(c) Complaints shall be rectified with in 24 Hours.if contractor fails to attend the complaints a recovery of Rs 500 per day shall be deducted from payment due to contractor(e) Weekly inspection of all security lights/street lights of area under AFS AFS Dhansa, Narela & Indora shall be carried out and report shall be submitted to Engr-in-chage with out any delay.
660
-
-
... More
Supply and fixing in replacement LED Bollard 8 watt 230 watt volts AC outdoor type with decorative for 360 degree indirect light IP 65 class protection with aluminium die cast housing cum heat sink circular at the top and opaque acrylic cover for 360 degree indirect uniform glare free light distribution impact and corrosion resistant operating voltage range 140v to 270 V, total system lumen not less than 3200 lumens lumen efficiency =80 lm/watt , THD≤ 20 CRI80 , colour temperature 6500 K/3500K/3000K as required at site, inbuilt surge protection = 5 Kv, 50000 Hrs burning hours complet all as specified and directed. Note- (1)Earth work and PCC shall be included in quoted rate.(2) Model and design shall be finalized by GE.
18
-
-
... More
S&F in replacement of PVC SMC boxes with hinged door fixing of size 333mmx233mmx120 mm with MS clamp made to shape with necessery nut bolts and washers complete comprising of Aluminium busbar 63 Amps capacity of suitable size mounted over porcelain insulator withMS clamp nut bolts & washers incl MCB 6 Amps and making incoming and outgoing connections by taking out loops of cable of any size incl necessary excavations and other civil works all as specified and directed. Make- Sintex/ Universal /SMS or equvalent out of make specified in List of makes
53
-
-
... More
S&F in replacement of cable PVC insulated unarmored for connection 2.5 Sqmm 3 core copper conductor duly drawn from junction box to street light fitting on poles in heavy duty rigid PVC conduit pipes complete all as specified and directed.
180
-
-
... More
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of poles with one coat of primer and two coats of aluminium paint of approved make incl writing pole nos on white backgrounds with black paint , complete all as specified and directed.
4
-
-
... More
M&L street light bracket made out from GI Pipe 32 mm bore, light grade, 1.2 m long bent to shape including fixing 02 set of clamp made out from MS Flats of size 25x5 mm complete with nuts and bolts and washers of suitable size duly painted with two coats of aluminium paint over a coat of red oxide primer all as specified and directed .
25
-
-
... More
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 95 sqmm x 3.5 core complete all as specified and as directed.
Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
110
-
-
... More
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 50 sqmm x 3.5 core complete all as specified and as directed.
Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
210
-
-
... More
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 25 sqmm x 4 core complete all as specified and as directed.
Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
195
-
-
... More
Supply, laying and testing in replacement cable XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 Volts grade cross sectional area 16 sqmm x 4 core complete all as specified and as directed.
Note : Provision of suitable double crimpped lugs and glands deemed to be included in quoted rates.
160
-
-
... More
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.50m deep for laying of water pipe lines/taking out pipe lines and getting out in soft/lose soil including forming bottom surface to required level and slope complete all as specified and directed.
295
-
-
... More
Returing ,fiiling including spreading ,leveling ,watering and well ramming in layers not exe. 25 cm soil all as specified and directed.
240
-
-
... More
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the strarting point complete all as specified and directed.
55
-
-
... More
Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted.
Note : Punned down thickness shall be measured and paid .
44
-
-
... More
Supplying and laying un-reinforced precastconcrete cable cover,Class LV, Type I, flat, size 250
mm x 150mm x 40mm all as specified and directed by Engr in- charge..
3600
-
-
... More
M& L in replacement for earth continuity conducted or main earthing lead fixed to wall/ceiling on batten or recess or chases or buried in ground or drawn in conduit/pipe or other directed situation for earthing etc as required 20x3 copper strip all as specified and directed.
40
-
-
... More
S&F in replacement SMC/DMC insulator for seperation of earth strip from wall /ceiling including fixing aceessoriese such as nut bolt etc complete all as specified and directed.
50
-
-
... More
Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled, screwed including 3 nos. 8mm dia 25mm long hex. head screw & brezing all joints complet all as specified & directed
15
-
-
... More
Supply, installing, testing and commissioning of maintenance free Chemical earthing by using copper earth plate 90 x 60 cm x 5mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earth strip 50 x 6 mm. thick by means of bolts, nuts, check, nuts and washers of galvanised iron or steel all, The ground enhancing compound made of Marconite donductive aggregate (consist of Marconite resian based cement, adhesive and gypsum plaster) shall not be less than 45 Kg. PCC Chamber of size 300 x 300 x 300 mm with cover shall be provided on the top of earth system on 100 mm thick PCC 1:3; 6 bed concrete. The chamber shall burried in ground with top edge projecting upto 75 mm from ground surface complete all as specified adnd directed. Note :- The earth rresistance valvue should be less than 3.00 Ohm . (ii) The quoted rate sahll include cost of copper strip 50 mm x 6 mm up to 7.5 Mtr lenght and earth pit bore hard /disintegrated rock. (iii) The contractor shall given a written guarantee for maintenance earth resistane of less than 3 ohm for a period of 5 Years from the certificate date of complection.
2
-
-
... More
supply and replace of maintanance free unserviceable battery 12 V, 120 AH with initial charging and testing compleete all as specified and as directed.
Make: Amaron/Exide/Microtek.
2
-
-
... More
Supply and fillling pre mix coolent suitable for DG set complete all as specified and directed. Make-: Castrol / Kirloskar / HP
110
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%