Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673542_1Tender No
CE CHZ/CHM/T-10/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Lump sum price worked out by the Contractor for "INTERNAL/HOT WATER SUPPLY AND SUMMER APPLIANCES" as as listed in Sch 'A' Sec IV
1
-
4393594.9
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL " as as listed in Sch 'A' Sec V
1
-
744595.92
Lump sum price worked out by the Contractor for "AREA DRAINAGE " as as listed in Sch 'A' Sec VI
1
-
929433.74
Lump sum price worked out by the Contractor for ROAD, PATH AND CULVERTS " as as listed in Sch 'A' Sec VII
1
-
971148
Lump sum price worked out by the Contractor for " EXTERNAL WATER SUPPLY" as as listed in Sch 'A' Sec VIII
1
-
337678.62
Lump sum price worked out by the Contractor for "EXTERNAL ELECTRIC SUPPLY" as as listed in Sch 'A' Sec IX
1
-
2726139.53
Lump sum price worked out by the Contractor for "LIFTS WORKS" as as listed in Sch 'A' Sec X
1
-
176306.8
Lump sum price worked out by the Contractor for "FIRE FIGHTING" as as listed in Sch 'A' Sec XI
1
-
36353351.8
Lump sum price worked out by the Contractor for "MECHANICAL LUNDRY WORKS" as as listed in Sch 'A' Sec XII
1
-
153831.02
Lump sum price worked out by the Contractor for "LIGHENING PROTECTION" as as listed in Sch 'A' Sec XIII
1
-
656536.74
Lump sum price worked out by the Contractor for "RAIN WATER HARVESTING" as as listed in Sch 'A' Sec XIV
1
-
1669296.94
Lump sum price worked out by the Contractor for "DEMOLITION/DISMANTLING" as as listed in Sch 'A' Sec XIV
1
-
9089297.93
INTERNAL ELECTRIFICATION
-
-
-
Supply & fixing RCBO-A type (SPN-2M) 32 Amps (In accordance with IS 12640-2 & IEC 61009-1) 240 V/415 V, 50 Hz with 10 KV short circuit capacity RCBO is desgined for use in domestic, commercial and industrial distribution systems at the most downstream circuit for ensuring protection from leakage current short circuit & over load to the user for a particular circuit. In normal use, it is safe to use and free of threat to user as sell as to environment complete all as specified and directed. Havells Cat No DHCEACSN2030032 or equivalent.
92
-
-
Supply & fixing Arc faut Detection Device (AFDD) 32A, rated voltage 415V AC, 50 Hz frequency, residual operting current 30MA, three module, Short circuit capacity 10KV. Type A, residual making and breaking capacity 500A, Electrical/Mechanical Endurance 10000 operations (made in India), Terminal capacity 25sqmm protection class IP-20, Portection class with enclosure IP-40, DIN Rail mounting method, Vibration Resistance 3g, shock Resistance 40mm free fall complete as specified and as directed.
20
-
-
Supply & fixing energy saving LED light fitting, 1 x 20 watt, 230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environment friendly, engery effcient ready to use pack. With electtronic driver and with best quality diffuser high lumen output, 2.5KV voltage surge protection, PF 0.98 THD10% suitable for surface/pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75Sqmm copper conductor cable complete all as specified and directed.
989
-
-
Supply & fixing energy saving LED light fitting, 1 x 10 watt, 230 volts, Decorative ultra slim linear LED lighting fixture with extruded polycarbonate, environment friendly, engery effcient ready to use pack. With electtronic driver and with best quality diffuser high lumen output, 2.5KV voltage surge protection, PF 0.98 THD10% suitable for surface/pendant mounting complete with all accessories including and connecting of with twin core of PVC insulated 0.75Sqmm copper conductor cable complete all as specified and directed.
101
-
-
Surface mounted wall Mirror LED light Compact & sturdy 20 Watt LED decorative fixture with anti glare polycarbonate diffuser, multi purpose lighting solution & applications all accessories & fixtures, iternally prewired and connecting by providing copper flexible wire 23/.0076mm twin core upto fitting, complete all as specified and directed.
61
-
-
Supply & fixing for LED bulb 7/9 watt 230 volts AC 50 Hz Retrofit B22 base complete all as specified and directed.
406
-
-
Supply fixing new generation engery and enviromental friendly long life LED building security light 1x25 watts made up of pressure die cast aluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with 32mm bore light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twin core form ceiling rose to light fittings complete all as specified and directed.
48
-
-
Supply & fixing modular fan step Regulator 2 module, 120w suitable for BLDC fans complete all as specified and as directed.
277
-
-
SUMMER APPLAINCES
-
-
-
Supply and fixing Voltage stabilizer automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% and capacity 2.0 KVA complete all as specified and as directed.
5
-
-
Supply,fixing and installation refrigerators, electric driven (single phase), capacity 460 ltrs. BEE 3star rated inclusive all necessary connection & testing,complete all as specified and as directed.
2
-
-
Supply and fixing Voltage stabilizer automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-) 2.5% and capacity 1 KVA complete all as specified and directed..
4
-
-
Supply and fixing desert cooler electric driven (single phase), having nominal air flow capacity of 4000 cum per hour (or nearest size),Plastic/PVC body including 3 core cord with 3 pin plug top and suitable trolly etc complete all as specified and directed.
176
-
-
SEWAGE DISPOSAL
-
-
-
Factory made Precast reinforced concrete rectangular drain and manhole cover slab with frame of Size 1200mm x 600mm x 100mm plain surface in concrete grade of M-30 with reinforcement inside @ 8mm dia MS TMT bars both ways in Single layer with 1.2mm MS Strip at corners epoxy painted complete all as specified and directed.
20
-
-
Factory made Precast reinforced concrete rectangular drain and manhole cover slab with frame of Size 1500mm x 600mm x 100mm plain surface in concrete grade of M-30 with reinforcement inside @ 8mm dia MS TMT bars both ways in Single layer with 1.2mm MS Strip at corners epoxy painted complete all as specified and directed.
26
-
-
H.D.P.E Double Wall Corrugated (DWC) pipes (ISI marked) 150mm bore SN -8 class as per IS 16098 part -II for nonpressure under ground drainage and sewerage applicantions with and including cost of special O rubber ring couples etc laid in trenches on concrete bed to level/gradient jointing with appropriate class fitting as per manufacturer's instructions including jointing accessories and fitting complete all as specified and directed by Engr -in-Charge.
140
-
-
H.D.P.E Double Wall Corrugated (DWC) pipes (ISI marked) 200mm bore SN -8 class as per IS 16098 part -II for nonpressure under ground drainage and sewerage applicantions with and including cost of special O rubber ring couples etc laid in trenches on concrete bed to level/gradient jointing with appropriate class fitting as per manufacturer's instructions including jointing accessories and fitting complete all as specified and directed by Engr -in-Charge.
95
-
-
H.D.P.E Double Wall Corrugated (DWC) pipes (ISI marked) 300mm bore SN -8 class as per IS 16098 part -II for nonpressure under ground drainage and sewerage applicantions with and including cost of special O rubber ring couples etc laid in trenches on concrete bed to level/gradient jointing with appropriate class fitting as per manufacturer's instructions including jointing accessories and fitting complete all as specified and directed by Engr -in-Charge.
190
-
-
Supply & fixing 300mmx300mmx25 mm overall size manhole rungs possessed unique slip resistant design made up of polypropylene 6mm thick over 12 mm dia steel bars confirming to IS 786 complete and all as specified.
45
-
-
ROAD PATH & CULVERTS
-
-
-
Rolling and consolidation of formation surfaces in cutting with 8 to 12 tonne capacity power road roller watering as necessary including filling in hollows and depressions and consolidating to required level, gradient and camber complete and all as specified.
150
-
-
Providing, Laying and compacting 150 mm thick (compacted thickness) Granular Sub Base Course (GSB) Grading as per Grade-II, as per Table 400-1 of MoRTH specifications for Road and Bridge works, 2013 in a single layer over compacted sub grade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required. The materials are mechanically mixed, spread and leveling on the subgrade by using mortar grader of adequate capacity and rolling with vibratory roller of capacity 80-100 KN static weight for achieving required compaction density of at least 98% of the maximum Dry Density, consolidating to required gradient and camber complete all as speccified and directed. Note : The finished surface tolerances as per table 900-1 of MORTH specifications for road and Bridge works.
225
-
-
Providing, Laying , campaction of Wet Mix Macadam conforming to Clause 406 of MORT&H specifications for Road and Bridge Works (Fifth Revision) 250 mm thick (compacted thickness) 125mm thick in two separate layers) with mechanically crushed aggregates and granular material (size range 53 mm to 0.075mm), grading of aggregates as per Table 400-13 of MORT&H specifications for Road and Bridge Works (Fifth Revision) including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub-base/ base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density required gradient and camber etc, complete all as specified and directed by Engr-in-Charge.
Notes : 1. The WMM shall be laid in two layers i.e each layer of 125mm thick (compacted thickness).
2. For payment purpose, both layers shall be considered as on unit.
375
-
-
Preparation of un-surfaced Wet Mix Macadam (WMM) surfaces by sweeping clean by broom or mechanical sweeping and removing completely all loose material and other foreign and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a prime coat of Cationic Bitumin Emulsion SS1 grade, confirming to IS 8887 (latest edition) @ 7.5 kg per 10 sq metres on surface of WMM/WBM as specified in Table 500-3 of MoRTH Specifications for Road and Bridge Works 2013 (Fifth Revision), using mechanical sprayer complete all as specified and directed.
150
-
-
Preparation of bituminous surface and applying evenly a tack coat conforming to clauses 503-5 of MoRTH specification for Road and Bridge Works 2013 (Fifth Revision), with cationic bituminous emulsion RS1 grade, confirming to IS 8887 (latest edition) @ 2.5 kg per 10square metre using mechanical sprayer after cleaning of existing surface complete and all as specified.
28
-
-
Providing, laying & compaction of Bituminous Macadam (BM) confroming to Clause 504 of MORT&H specifications for Road and Bridge Works (Fifth Revision), using mechanically crushed stone aggregates and granual material etc of grading II as per Table 500-7 of MORT&H specifications for Road and Bridge (Fifth Revision), premixed with bituminous binder, Bitumen grade VG-30 @ 3.50% (percetage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled vibratory and tandem rollers as per specifications to echieve the desired compaction and density completed all as specified and directed.
Notes : (i) The contractor shall quote the rate against item considering 3.5% VG-30 bitumen content. Job mix formule as per MoRT&H specifications for road and bridge work (Fiffth Revision) for bitumious concrete shall be got designed from NIT/CTL/Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall be less 3.4% by weight of total mix as per clause 504.2.4 of MoRT&H specifications (Fifth Revision).
(ii) If qty of binder contents is less than the qty as specified in respetive items of BOQ, it shall be adjusted at supply only rates of paving bitumen @ Rs 55.00 per Kg and if qty of binder content is more than the qty as specified in respective items of BOQ no adjustment shall be made.
91
-
-
Applying evenly a Tack coat conforming to clauses 503-5 of MoRTH specification for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion RS1 grade, confirming to IS 8887 (latest edition) @ 2.5 kg per 10sq meters using mechanical sprayer after cleaning of existing surface complete and all as specified.
181
-
-
Providing and laying 30 mm thick (consolidated thickness) Bituminous Concrete(BC) layer conforming to clause 507 of MoRT&H specifications for raod and bridge work (Fifth Revision) including cost of coarse aggregates, fine aggregates, filler, 5.5% binder (paving Bitumen grade VG-30) content by weight of total mix and crushed aggregates, of grading 2, Anti Stripping Agent, Warm Mix Additives (quantity, quality and grade as per the approved Job Mix Formula) etc, cleaning and pre-heating of the mineral aggregate, filler & bitumen to the specific temperature, thorougly mixing with binder of specifed bitumen content, Anti Stripping Agent, Warm Mix Additives as per mix design in Hot Mix Plant of 100-120 TPH capacity, carrying the hot mixed materials by means of tipper, trucks, or any other approved and suitable arrangements, laying the hot premixed materials over the prepared surface by means of paver finisher including manual operation as and when required for proper grade, level and camber through rolling with power roller 8 to 12 tonnes smooth wheeled, vibratory and tandem roller with necessary hand packing and pinning to give an even surface, including running expense of all plants and machineries, inclusive of proper traffic control during laying to the satisfaction of Engr-in-Charge, required quality control tests at required interval etc complete in all respects complete all as specified and directed.
181
-
-
Prepraring bituminous surface of road and marking 2.00mm thick centre line, stop line, dashes, arrows etc. and the like n exc 10 cm wide on road pavement with hot applied thermoplastic road marking paint of approved colour conforming to BS 3262-1989 with special applicator machine all as per manufacturer instructions complete all as specified and directed.
750
-
-
Manufacturing, supplying and fixing Retro- reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc. will be as per IRC - 67 with required colour scheme on the boards and with the high intensity grade A. The aluminium sheet to be riveted to M.S. frame of angle iron of size 40x40x4 mm. The boards will be fixed to 1 No. 50x50 mm square post made of M.S. angle 50x50x4 mm, 4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge
3
-
-
EXTERNAL WATER SUPPLY
-
-
-
Supply and fixing Ductile iron fittings such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket/spigot caps and plugs suitable upto 100 mm bore ductile iron pressure pipes of K-9 classification including nuts, bolts, washer and push on flexible rubber gasket joints, complete all as specified and directed.
250
-
-
Supply and laying centrifugally cast ductile iron pressure pipe 100 mm bore, with socket & spigot ends ISI marked with IS 8329/2000 classification K9, In standard length of 5.5 - 6 m suitable for and including push on tyton joint with cement mortar lining in the pipes, complete all as specified and directed.
NOTE:-Ductile iron fittings will be measured and paid for separately.
680
-
-
Supply and laying centrifugally cast ductile iron pressure pipe 80 mm bore, with socket & spigot ends ISI marked with IS 8329/2000 classification K9, In standard length of 5.5 - 6 m suitable for and including push on joint (gasket D jointing) with cement mortar lining in the pipes, complete all as specified and directed.
NOTE:-Ductile iron fittings will be measured and paid for separately.
350
-
-
Supply and fixing Foot Valve of size 80 mm bore conforming to IS 4038, complete all as specified and directed.
2
-
-
Supply & fixing centrifugal pump, electric driven for 440v, 3 phase 50 HZ confirming to IS-12469:1988 with CI casing bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for 475 LPM discharge,30M head inclusive PCC foundation and MS common base frame complete all as specified and directed. Note: ( 01 working + 01 standby)
2
-
-
Construction of valve pit of size 1000x1000x900mm with concrete block construction with wall thickness not less than 200 mm including all necessary excavation and earth work in hard dense soil returning filling in disposal of surplus soil to a distance not exceeding 50 m and depositing where as directed. PCC in foundation (1:3:6) type C2 using 40mm graded crushed stone aggregate 150 mm thick, PCC in coping on top 1:2:4, type B1 using20 mm graded crushed stone aggregate50 mm thick including rendering 15 mm thick plaster in cement mortar 1:4 on exposed surface and two coat of white wash on exposed surface on external wall above ground level and angle iron frame 50x50x6 mm MS sheet cover 3.15 mm thick with hinges, handle and locking arrangement. Painting all MS work with two coat of synthetic enamel paint a coat of red oxide primer and painting all the MS surface embedded in PCC with two coat of black bitumen paint complete all as specified and directed.
5
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size indoor cubicle type totally enclosed outer edge made out of 2 mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with and including following accessories :- (A) Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated of capacity 150 Amps with colour coding in separate sheet steel enclosure with front shutter in two halves having lockable arrangement . (B) MCCB 415 Volts, 100 Amp, rating 4 Pole 36 KA rupturing capacity (Ics=100%Icu) -01 No (Incoming) (C) Voltmeter 0-500V digital type with selector switch 96mm X 96 mm square flush mounted-2 Nos (D) Ampere meter digital type CTs operated including CTs 0-200A 96 mmx96 mm flush mounted with selector switch-2 Nos (E) LED type Indicating lamps panel mounting type RYB-Set of 3 (F) MCCB 415 Volts, 63 Amp rating 4 Pole of Breaking Capacity 25 KA(Ics=100%Icu)-3 Nos (outgoing, 01 for each motor and 01 spare) (G) suitable star delta starter-02 Nos Note:- 1. The platform shall be of 600 mm height above ground level and 450 mm below ground level leaving minimum 100 mm all around the feeder pillar board. 2. Rate for PCC foundation for panel deemed to be included in item rate. 3. Drawing for LT panel shall be approved by GE before placement of order
1
-
-
EXTERNAL ELECTRIC SUPPLY
-
-
-
Supply, installation, testing and commissioning of 400 KVA outdoor transformer floor mounted 11KV on HT side and 433 volts on LT side at no load step down 3 phase 50 c/s AC double wound oil immersed air natural oil natural with external cooling tubes core type. Transformer with off load tapping on HT side to vary secondary voltage +- 7.5% in steps of +-2.5 %. The transformer shall confirm with the requirement of IS-2026 and oil shall confirm to IS-335,1983. The temp rise shall not exceed 55 degeree centigrade in winding and 45 degree centigrade in oil when measured by the resistance method after continous full load run and on ambient temp of 48 degree centigrade, copper wound, (losses shall be as per IS-1180 Part I 2022 level 2), all as specified. The transformer shall be complete with the following:-
(a) HV Bushing of suitable size.
(b) LV glands and cable box of suitable size.
(c) Oil conservator.
(d) Dehydrating breather with first fill of dehydrating agent.
(e) Thermometer pocket with thermometer dial of suitable size.
(f) Two Earthing terminals on tank and take cover with lugs to suit 32x6 mm GI strip.
(g) Rating Plate.
(h) Terminal marking plate.
(i) Oil level gauge.
(j) Oil drain and filter valve.
(k) Lifting lugs
(l) Four plain rollers.
(m) Oil filter plug with connection complete.
(n) Extra bushing for neutral outside the cable box for providing independent earthing.
(o) Oil filling hole with cap.
(p) First filling of oil.
(q) Cable box on LV side with cable gland Note: (i) Drg of transformer must get approved from GE before execution.
(ii) Pre-commissioning of transformer shall be carried out by "SEI" within overall cost quoted.
(iii) Necessary T&P required for testing shall be provided by contrctor.
1
-
-
Material & labour for platform for transformer of size 3000 x 2500 x 1200 mm with brick masonry construction in cement mortar 1:4,150 mm thick, PCC (1:4:8) type D-2 150 mm thick in foundation 30cm depth , PCC (1:2:4) type B-1, 40 mm thick in floor over sub base PCC (1:4:8) type D-2, 75 mm thick, brick masonry step on one side, 15mm thick plastering to brick masonry in cement mortar 1:4 and two coats of white wash on plastered surface including excavation and earth work in any type of soil complete all as specified and directed.
Note : (1) Cost of chain link fencing GI wire of dia 2.5mm, 1.2 m high around 1 m distance from all sides of transformer platform ,2- pole structure and LT panels including provision of suitable size of gate with locking arrangement is deemed to be included in quoted rate.
(2) Drg of platform & fancing must get approved from GE before execution.
1
-
-
Double wall corrugated high density polyethylene pipes outer dia 50 mm, inner dia 39 mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS- 14930 (Part I&II) for protection of underground cables with all fittings, laid in trenches /road/nallah or fixed along wall , poles or laid under floor etc all as specified
80
-
-
Double wall corrugated high density polyethylene pipes outer dia 100 mm, inner dia 63.5 mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS- 14930 (Part I&II) for protection of underground cables with all fittings, laid in trenches /road/nallah or fixed along wall , poles or laid under floor etc complete and all as specified.
40
-
-
Double wall corrugated high density polyethylene pipes outer dia 80 mm, inner dia 63.5 mm having corrugation on the outer wall and plain surface on the inner wall confirming to IS- 14930 (Part I&II) for protection of underground cables with all fittings, laid in trenches /road/nallah or fixed along wall , poles or laid under floor etc complete and all as specified
40
-
-
Supply and fix Cable route indicator, showing 'HT UG cables' painted in brown colour and route of cable with arrow, made of CI in suitable elliptical shape and fixed with MS rod 12mm dia 70mm long ( all words embosed) and embedded in PCC block of size 30x30x60cm in ground complete all as specified.
5
-
-
Supply and fixing junction box of size 250x200x100 mm, made out of 1.6 mm thick MS sheet , having front open-able and lockable hinged shutter with self closing arrangement, rain shed outdoor type, weather and vermin proof, factory made, complete duly painted with two coats of synthetic enamal paint over a coat of red oxide primer, comprising of cadmium plated 04 pole terminal post, having arrangement of connecting incoming and outgoing cables, fixed on pole with clamp of size 25x5 mm with MCB SP 'B' series 6 Amp, 240 Volts, 10 KA mounted on Din rail, thimbles etc all as specified and directed .
23
-
-
Supply and installation street light control panel outdoor type, weather and vermin proof having digital astronomical time switch, with pollution free lithium cell programming concept display of time and programme with manual by pass switch DIN rail mounted, suitable for 240 Volt, 50/60 Hz with contactor heavy duty four pole 63 Amps -01 No, MCCB 4 pole 100 Amps 25 KA (Ics=100%Icu) -01 No as incomer, Bus bar 100 Amps -04 Nos, Indicating lamp 03 Nos and MCB TP 40 Amps- 05 Nos, including enclosure outdoor type floor mounted made out of CRCA sheet of 2.0 mm thick double panel type openable from front and rear side, rubber lining, locking arrangement, powder coated complete mounted on MS channel of min size 75x40 mm and with sufficient working space having locking arrangements complete all as specified and directed.
1
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size (main feeder pillar) factory fabricated (factory approved by CPRI) out door cubicle/ KIOSK type totally enclosed outer edge made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation (1:2:4) and 1200 Amprating aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with CTs, Ammeter, voltmeter,indicator lamp,danger plate including following accesories. INCOMING:- (Main panel) (i) ACB 4 Pole, 415 V, Manual Drawout type with microprocessor release of capacity 800 Amps 50 KA having LCD display with min 50 fault records =01 Nos OUTGOING:- (ii) MCCB 250 Amp, 4 pole 36 KA =1 Nos (ii) MCCB 200 Amp ,4pole 36 KA =1 Nos
(iii) MCCB 160 Amp ,4pole 36 KA =1 Nos
(iv) MCCB 125 Amp ,4pole 36 KA =2 Nos
(v) MCCB 63 Amp ,4pole 25 KA =2 Nos Note: Drawing for LT panel shall be approved by GE before placement of order and all necessary work like electric connection from existing panel to new panel to be made by the contractor.
1
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size (main feeder pillar) factory fabricated (factory approved by CPRI) out door cubicle/ KIOSK type totally enclosed outer edge made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation (1:2:4) and 400 Amprating aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with CTs, Ammeter, voltmeter,indicator lamp including following accesories. INCOMING:- (Essential/DG panel) (i) MCCB 250 Amps, 4 pole,36 KA = 01 No (Main Incoming ) OUTGOING:- (ii) MCCB 100 Amps, 4 pole 25 KA = 3 Nos ( 01 spare) (ii) MCCB 63 Amps, 4 pole 25 KA = 2 Nos ( 01 spare)
(iii) TPN 32 Amp ,10KA = 1 Nos
Note: Drawing for LT panel shall be approved by GE before placement of order
1
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size (main feeder pillar) factory fabricated (factory approved by CPRI) out door cubicle/ KIOSK type totally enclosed outer edge made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation (1:2:4) and 250A aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with CTs, Ammeter, votmeter,indicator lamp including following accesories. INCOMING:- Panel-1(Sub panel) (i) MCCB 160 Amps, 4 pole,36 KA = 01 No (Main Incoming ) OUTGOING:- (ii) MCCB 63 Amps, 4 pole 25 KA = 4 Nos ( 01 spare)
Note: Drawing for LT panel shall be approved by GE before placement of order
1
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size (main feeder pillar) factory fabricated (factory approved by CPRI) out door cubicle/ KIOSK type totally enclosed outer edge made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation (1:2:4) and 100 Amprating aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with CTs, Ammeter, voltmeter,indicator lamp including following accesories. INCOMING:- Panel-4 (for ORs mess) (i) MCCB 63 Amps, 4 pole,25 KA = 01 No (Main Incoming ) OUTGOING:-
(ii) TPN 32 Amps,10KA = 3 Nos (1 spare) Note: Drawing for LT panel shall be approved by GE before placement of order
2
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size (main feeder pillar) factory fabricated (factory approved by CPRI) out door cubicle/ KIOSK type totally enclosed outer edge made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation (1:2:4) and 100A aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with CTs, Ammeter, votmeter,indicator lamp including following accesories. INCOMING:- (for F/F main) (i) MCCB 63 Amps, 4 pole, 25 KA = 01 No (Main Incoming ) OUTGOING:-
(i) MCCB 40 Amps,4 pole, 16KA = 4 Nos (1 spare) Note: Drawing for LT panel shall be approved by GE before placement of order
1
-
-
Supply installiation, testing and commissioning factory made Feeder pillar made out of 3.15 mm thick incorporated with 3 phase 4 wire system aluminum busbar 100 amp, insulator with one no of incoming MCCB 40 Amp, 16 KA and outgoing 32 Amps TPN 4 pole , 415 volt, suitable DOL starter,3 Phase 50 HZ fixed on angle iron frame grouted in the PCC 1:2:4 type B-I upto 30 cm duly painted with powder coated paint and angle iron frame with two coat of synthetic enamel paint over a coat of red oxide primer paint complete all specified and directed. Note: Drawing for LT panel shall be approved by GE before placement of order . Note - For each block fire fighting eqpt.
3
-
-
Dismantling of existing service cable 6 sqmm to 16 sqmm complete and as directed Engr-in-Charge.
600
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size (main feeder pillar) factory fabricated (factory approved by CPRI) out door cubicle/ KIOSK type totally enclosed outer edge made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation (1:2:4) and 200Amprating aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with CTs, Ammeter, voltmeter,indicator lamp including following accesories. INCOMING:- Panel-2&3 (Sub panel) (i) MCCB 125 Amps, 4 pole,36 KA = 01 No (Main Incoming ) OUTGOING:-
(ii) MCCB 63 Amps, 4 pole 25 KA = 2 Nos (01 spare) (iii) MCCB 40 Amps, 4 pole 16 KA = 3 Nos ( 01 spare)
Note: Drawing for LT panel shall be approved by GE before placement of order
2
-
-
Supply installiation, testing and commissioning factory made CPRI approved,outdoor type, floor mounted, Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz
system of capacity 200 KVAR including MD-XL capacitor and suitable MCCB as incomer(Auto/mannual option) with 6 step ( 3X50+1X25+2x12.5).
1
-
-
LIFT
-
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size out door cubicle/ KIOSK type totally enclosed outer edge made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged pannel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with and including following accessories :-
(A) Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated of capacity 150 Amps with colour coding in separate sheet steel enclosure with front shutter in two halves having lockable arrangement .
(B) MCCB 415 Volts, 100 Amp, rating 4 Pole 36 KA rupturing capacity (Ics=100%Icu) -01 No (Incoming)
(C) Voltmeter 0-500V digital type with selector switch 96mm X 96 mm square flush mounted-1 No
(D) Ampere meter digital type CTs operated including CTs 0-200A 96 mmx96 mm flush mounted with selector switch-1 No
(E) LED type Indicating lamps panel mounting type RYB-Set of 3 (F) MCCB 415 Volts, 40 Amp rating 4 Pole of Breaking Capacity 16 KA(Ics=100%Icu)-04 No (outgoing, 01 for each lift and 01 spare)
Note:- 1.The platform shall be of 600 mm height above ground level and 450 mm below ground level leaving minimum 100 mm all around the feeder pillar board. Rate for PCC foundation for panel deemed to be incl in the quoted rate. 3. Drawing for LT panel shall be approved by GE before placement of order
1
-
-
Design supply, install testing & commissioning 8 passengers with machine room lift, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS- 14665, suitable to serve G + 04 upper floors with AC Variable Voltage & Variable Frequency drive(VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (one each in car & near Ground floor landing door),standard panel suitable for lift complete all as specified with followings accessories:- 1. Car dimensions 1100 mm wide x 1300mm deep x 2200mm high 2. Door opening min 900mm wide x 2000mm high
3. Handrail Round handrail in Stainless Steel finish provided on rear wall of car 4. ACVVVF closed loop drive
5. Alarm button in car operating panel with battery back-up 6. Automatic operation for car fan 7. Adjustable door open time
8. Anti-nuisance (empty car) 9. Anti-nuisance (car call cancellation at direction reversal) 10. Blower fan in car for ventilation 11. Braille on push buttons 12. Car call cancellation by double pressing floor button in car operation panel
13. Door open and door close buttons in car operating panel 14. Door closing retries 15. Door nudging 16. Emergency light 17. Full load by-pass 18. Home landing 19. Infra-red screen for car door 20. Intercom 21.Jammed landing operating panel call button by-pass 22. Motor overheat protection 23. Overload function with audio-visual indication in car operating panel 24. Phase failure and phase reversal protection 25. Automatic rescue device in case of power failure 26. Attendant control 27. Car arrival chime on car 28. 4.3'' LCD display in landing operating panel on all floors 29. Fireman control 30. Fireman emergency return 31. Independent operation (car VIP function) 32. Parking operation (key switch in landing operating panel) on main floor 33. Voice announcement unit in English language in car 34. RCC Socle for car and counter weight buffers.
Note:(i) "Pre-commissioning of lift shall be carried out by "State Lift Inspector "within overall cost quoted. In case of non availability of " State Lift Inspector" rep of AO shall be carryout "pre-commissioning test within overall cost quoted.
(ii) Lift shall be operated by contractor before completion for a period of one month duly on successful operation for one month, lift shall be taken over. Complete expenditure on account shall be borne by contractor. (iii) All circuit wiring for lift shall be with fire survival type wires only.
3
-
-
FIRE FIGHTING
-
-
-
Supply and fixing 63mm dia instantaneous pattern branch short stanless steel 304 pipe, min 20 mm dia nozzle conforming to IS903, suitable for inter connection to hose pipe coupling complete all as specified and direct.
26
-
-
Material & fabour air release valve of size 25 mm dia complete all as specified and directed
3
-
-
Supply and fixing for 2 way fire brigade complete all as specified and directed
3
-
-
Supply and fix addressable fire alarm control panel complying with BS EN 54 single loop panel including 12V/7AH maintenance free battery for operation of panel complete all as specified and directed.
3
-
-
Supply and fixing Carbon dioxide based Aluminium Body Capacity 4.5KG Fire Extinguisher with Used/Unused Indicator squeeze Grip type Store pressure,Fire Rating of different class of fires - 55B,Product Should be PED(Pressure Equipment Directive) approved, Discharge mechanism Squeeze Grip Only,complete all as specified and as directed.
40
-
-
Supply and fixing Portable Fire Extinguisher MAP 90 Powder Based 4 kg capacity, Store Pressure type,Fire Rating should be 6A & 183 B as per IS and 27A & 183B as per EN Standard , Product should be EN aproved, PED(Pressure Equipment Directive) Approved and CE marked,Bulk range throw should be minimum 4 to 5 m,complete all as specified and as directed.
30
-
-
Supply and fixing Portable Fire Extinguisher MAP 90 Powder Based 9 kg capacity, Store Pressure type,Fire Rating should be 6A & 233 B as per IS and 43 A & 233 B as per EN Standard ,Product should be EN aproved, PED(Pressure Equipment Directive) Approved and CE marked,Bulk range throw should be minimum 5 to 6 m,complete all as specified and as directed.
4
-
-
Supply and fixing Portable Aqueous Film Forming Foam (AFFF) Based 9 Ltr capacity Store Pressure type Fire Extinguisher,Fire Rating should be 3A & 144 B as per IS and 13 A & 144 B as per EN Standard ,Product should be EN aproved, PED(Pressure Equipment Directive) Approved and CE marked, Bulk range throw should be minimum 5 m,complete all as specified and as directed.
4
-
-
Supply and fixing Portable Watermist Based 9 Ltr capacity Store Pressure type Fire Extinguisher,Cylinder/vessel Material should be Stainless Steel Body,Class A Fire Rating as per EN Standard -13A,Fire Rating for Class F -75F, Autual Discharge time - 42 to 44 second, Marine Equipment Directive(MED) Approved, complete all as specified and as directed.
30
-
-
Supply and fixing Portable Wet Chemical Based 6 Ltr capacity Store Pressure type Fire Extinguisher,Fire Rating should be 3A & 75F as per IS Standard , Weight should be Fire Extinguisher 11 to 13 kilogram, Product should be EN aproved, PED(Pressure Equipment Directive) Approved and CE marked, Bulk range throw should be 3 to 5 m,complete all as specified and as directed.
4
-
-
Supply and fixing fire bucket with stand complete all as specified and directed.
4
-
-
Supply and fixing Automatic fire detection and supression system for Electrical Panel Clean Agent Gas HFC 236 fa / HFC227ea based Fire Suppression System 2Kg Cylinder - with 20 m Heat Sensing Tube,For Open and Enclosed Cabinet with Force and natural airflow Panel along System, operating pressure 15 bar at 20⁰C ,System operating temperature range : -20⁰C to +60⁰C,The sensing tube must be made of a special modified Polyamide (PA) in Black colour with an outer diameter of 6mm,Tube’s technical specifications should be certified by the OEM to its own specifications,The complete system should be tested & Certified to Standard LPS 1666:Issue 1.0 by LPCB, System should be Certified and approved in both force and natural airflow, With Modular Monitoring Kit,End of Line Plug,End of Line adapter for pressure gauge,complete all as specified and as directed.
9
-
-
Supply and fixing of Emergency Exit Signage Size 300mm x 150mm,Material Used - Non Radioactive,non-phosphorous,non toxic and lead free,Made Of Photoluminescent rigid plastic,Printed on High Quality gloss paint. Showing Exit Direction towards Right Side, complete all as specified and as directed.
30
-
-
Supply and fixing of Emergency Exit Signage Size 300mm x 150mm,Material Used - Non Radioactive,non-phosphorous,non toxic and lead free,Made Of Photoluminescent rigid plastic,Printed on High Quality gloss paint. Showing Exit Direction towards Left Side
30
-
-
Supply and fixing of Emergency Exit Signage Size 400mm x150mm,Made Of Photoluminescent rigid plastic,Printed on High Quality gloss paint. Showing No Smoking Zone.
50
-
-
Supply and Fixing of Emergency Exit Signage Size 200mm x 300mm, Made Of Photoluminescent rigid plastic,Printed on High Quality gloss paint. Showing Place of Fire Extinguisher.
Note:(i) Complete schedule of fire fighting shall be carried out as per recommendation of CFEES as per their latter No. 0225/KK/TFA/CFEES/2023 dt 29 Dec 2023.
(ii) Complete scheme shall be tested in presence of rep of user, rep of CWE & Engr-in-charge before issue of completion certificate. Only on successful operation of scheme completion shall be issued accordingly.
(iii) Complete scheme shall be checked for successful operation at an interval of 6 months till completion of defect liability period. Cost of these checks shall be included in overall cost quoted.
(iv) Refilling of portable type Fire extinguisher shall be carried out every six month till completion of defect liability period within overall cost quoted.
(v) Complete scheme shall be executed by an agency which has minimum three years experience in executing similar works.
(vi) Any item required for successful operation of scheme is deemed to be included in overall rates quoted.
(vii) Layout of complete scheme shall be prepared before execution and shall be got approved from GE.
(viii) Exit signage as per recommendation of CFEES shall be provided.The sizes and colours of the exit signage in accordance with IS-9457, IS-12349 and IS-124047.
90
-
-
MECHANICAL LAUNDARY
-
-
-
Supply installation, testing and commisioning weather and vermin proof LT feeder pillar box of suitable size out door cubicle/ KIOSK type totally enclosed outer edge made out of 3.15mm thick CRCA Sheet and inner compartments of 2.00 mm thick sheet metal enclosure with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel door (covers) on two sides with handle, bottom gland plate and locking arrangement consisting of sufficient nos of circular cable entry holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wires of adequate size, duly powder coated internally & externally of approved colour with PCC foundation and aluminium bus bar for 3 phase & neutral mounted on epoxy insulator with and including following accessories :-
(A) Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated of capacity 300 Amps with colour coding in separate sheet steel enclosure with front shutter in two halves having lockable arrangement .
(B) MCCB 415 Volts, 200 Amp, rating 4 Pole 36 KA rupturing capacity (Ics=100%Icu) -01 No (Incoming)
(C) Voltmeter 0-500V digital type with selector switch 96mm X 96 mm square flush mounted-1 No
(D) Ampere meter digital type CTs operated including CTs 0-200A 96 mmx96 mm flush mounted with selector switch-1 No
(E) LED type Indicating lamps panel mounting type RYB-Set of 3 (F) MCCB 415 Volts, 63 Amp rating 4 Pole of Breaking Capacity 25 KA(Ics=100%Icu)-06 Nos (outgoing, 01 for each machine and 02 spare)
Note:- 1. The platform shall be of 600 mm height above ground level and 450 mm below ground level leaving minimum 100 mm all around the feeder pillar board. Rate for PCC foundation for panel deemed to be included in item rate. 3. Drawing for LT panel shall be approved by GE before placement of order
1
-
-
Supplying, installation, commissioning and testing washing machine hydro extractor of 30 kg capacity, direct drive, self balancing, suspension type, with and including automatic electromagnetic DC injection brake system auto timed, top loading, vibration less, inner basket and outer drum stainless steel with specially designed foundation frame for grouting the machine, having the facilities of dismantling the inner basket without dismantling the outer body, also inclusive of specially designed eletric motor and control panel suitable for operation on 415 Volt, 3 Phase, 50Hz, AC supply, complete with all other components, parts fixtures & accessories all as specified and directed
2
-
-
Supplying, installation, commissioning and testing of commercial fully automatic drying tumbler of Cap 30 Kg (per charge) front loading, electrically heated,stainless steel body, auto timed, auto stop, auto reverse, with fully die pressed door inner basket stainless steel outer drum double wall insulated with glass wool, electric motors of suitable matching capacity with suitable RPM, full electric protection against single phase complete with control panel complete all as specified and as directed
2
-
-
RAIN WATER HARVSTING
-
-
-
Gravity flow filter unit of size 4.0m x 3.0m x 0.90m with supply and filling of filter media in the recharge Pit in the following manners:-
(a) Bottom layer 30cm thick of gravel of size 20 to 30mm.
(b) Middle layer 30cm thick of gravel of size 5 to 10mm.
(c) Top layer 30cm thick of coarse sand of 2 to 4mm.
2
-
-
Supply & fixing 300mmx300mmx25 mm overall size manhole rungs possessed unique slip resistant design made up of polypropylene 6mm thick over 12 mm dia steel bars confirming to IS 786 complete and all as specified.
20
-
-
Material & labour for factory made Precast reinforced concrete rectangular drain and manhole cover slab with frame of Size 1200mm x 600mm x 100mm plain surface in concrete grade of M-30 with reinforcement inside @ 8mm dia MS TMT bars both ways in Single layer with 1.2mm MS Strip at corners epoxy painted complete all as specified and directed.
20
-
-
Material & labour for factory made Precast reinforced concrete rectangular drain and manhole cover slab with frame of Size 900mm x 900mm x 100mm plain surface in concrete grade of M-30 with reinforcement inside @ 8mm dia MS TMT bars both ways in Single layer with 1.2mm MS Strip at corners epoxy painted complete all as specified and directed.
25
-
-
Drilling of bore of size 150 mm dia upto 200 m depth by direct rotary mechanical system for injection well in any type of including hard/boulders complete all as specified and directed.
180
-
-
Reaming of bore well from 150 mm dia to 300 mm dia hole below the ground level in any type of strata of soil/includingboulders/rocks etc complete all as specified.
180
-
-
Supply assembling and lowering mild Rigid PVC blind casing pipe wall thickness not less than 7.5 mm heavy grade of size 150 mm dia socketed including fitting riveting jointing and lowering in bore hole confirming to IS-12818 complete all as specified and directed.
140
-
-
Supply and fixing HPDE PVC pipe 150 mm bore single socket wall thickess not less than 7.5 mm in any length slotted with rubber joint complete all as specified and directed.
40
-
-
Supply and fixing PVC/MS bail plug assembly suitable for 150 mm dia bore PVC casing pipe complete all as specified and directed.
2
-
-
Supply and fixing PVC/MS bail plug assembly suitable for 150 mm dia bore PVC casing pipe complete all as specified and directed.
2
-
-
Material & Labour for pea gravel of size 2 mm to 5 mm packing all around the casing pipe to entire depth upto ground level complete all as specified and directed.
4
-
-
Devlopement of injection bore well with compressed air with diesel engine operated compressor for number of hours till free flow of water in well complete all as specified and directed.
16
-
-
Construction of recharge pit of size 4.0 m X 3.0 m X 3.0 m with brick/RCC work including padding in base with supply and filling of filter media in the recharge Pit in the following manners:- Bottom layer 50 cms thick of gravel of size 10 to 20 mm
Middle layer 50 cm thick of gravel of size 6 to 10 mm
Top layer 60 cm thick of coarse sand of 1.5 to 2 mm
2
-
-
Material & labour for MS cross of size 200mmX 200mm with 150mm branches made out of MS pipe heavy grade having internal threads all as directed.
2
-
-
Supply and fixing collector pipe for recharge pit, made of slotted MS pipe medium grade size 150mm dia complete all as specified and directed.
4
-
-
Supply and fixing MS clamp, 1050mm long made out of MS flat of size 150mm wide 20 mm thick suitable for casing pipe of 150 mm dia in two halves with suitable nuts bolts and washers, including two coat of black bituminous paint over a coat of red oxide primer complete all as specified and directed.
4
-
-
DG SET
-
-
-
Supply, installation , commissioning and testing Manufacturer or OEM (original equipment manufracture) Diesel Engine Driven Generating set capable of delivering 40 KVA or nearest higher rating 415 volts (AC 3 phase, 1500RPM, 4 wire system of supply), 50 Hz at power factor 0.8 minium. The DG set shall consist of a diesel engine flexible couping coupted dirrectly to matching alternator and mounted on metalastic foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure (the complete set conforming to and test certified as per CPCB norms IV or latest and as specified) all as specified, directed complete with AMF control panel standarised by manufacturer, fuel tank with mounting arrangement and inlet, outlet return oil arrangment, suitable exhaust pipe complete and shall comprise and including the following. (A) Engine (Prime Mover) : The diesel engine totally enclosed, compreession ignition, water cooled (radiator cooled) turbo charge cooled suitable for power generation application having minium of suitable BHP capacity to drive the 40 KVA alternator at 1500 rpm under NTP condition confirming to BS 649, complete with all interconnecting pipeing and the following standard acessories. Suitable fly wheel, flexible coupling, Air cleaner. Radiator heavy duty type, cooling fan, water circulating pump corrosion resistor, PT fuel pump, Electronic governing control (EGC), Fuel filter, Fuel shut down solenoid (24V DC, stop solenoid, Lubricating oil cooler, By pass filter Silencer, Starter.
(B) ALTERNATOR :- AC alternator copper wound, self excited, self regulated, self vent 40 KVA PF 0.8 1500 RPM insulation class 'H' Enclosure IP 23 complete with AVR with + 0.5% voltage regulation, directly coupled to and match the above engine and alternator confirming to IS 4722 permissibleoer load 10% for 1 hour in 12 hour operation complete all as per IS-13364.
(C) METALLASTIC : Anti-vibration pads for mounting engine, alternator assembly on the base frame/plate. (D) BASE PLATE : Base Plate shall be made out of structural steel as per manufacturer's recommended design/specifications. (E) ACOUSTIC ENCLOSURE : Provision of an intergral type approved/certified acoustic enclosure weather proff, water proff and corrosion free, as per lattest CPCB norms IV or latest, for the DG sets to restrict the noise level to 75 DB at one meter distance and temp rise within canopy shall not exceed 50--70 degree C. It shall be made of 14 SWG CRCA MS sheet with poer coated finish on outside and provided with non igniting fire retardant foam as acoustic material. There shall be four hinged doors out of which one shall be with a glass window. The base shall be of ISMB section all as directed and shall incllude as under:-
1
-
-
DEMOLITION
-
-
-
Disconnecting the power supply and taking down carefully by unscrewing from bourds fitting and fixture such as DBS juction box, panel of any size complete with all MCCB MCBS etc and removing from site comlete and as directed bu Engr -in-charge.
60
-
-
Taking down old unserviceable sub main wiring metre any size complete and as directed by Engr -in-charge
20
-
-
Note: For the purpose of arriving at Contract sum, the amount of Schedule of credit (i.e Rs 10135408.00) shall be deducted from the total amount arrived.
-
10135408
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%