Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_652552_2Bid Award Id
ViewTender No
GE/CHM-03/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per serial item 02 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
25
-
-
... More
All as per serial item 02 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
20
-
-
... More
Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed.
100
-
-
... More
All as per serial item 06 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed
25
-
-
... More
All as per serial item 06 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
35
-
-
... More
All as per serial item 06 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
20
-
-
... More
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of 3mm thick plastic laminated sheet, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed.
300
-
-
... More
All as per serial item 10 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed
50
-
-
... More
All as per serial item 10 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
75
-
-
... More
All as per serial item 10 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
45
-
-
... More
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of 3mm thick plastic laminated sheet, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed.
250
-
-
... More
All as per serial item 14 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed
45
-
-
... More
All as per serial item 14 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
65
-
-
... More
All as per serial item 14 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
35
-
-
... More
Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed.
250
-
-
... More
Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed.
40
-
-
... More
Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed.
185
-
-
... More
Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
40
-
-
... More
Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed.
65
-
-
... More
Modular switch type bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed.
20
-
-
... More
Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
785
-
-
... More
Switch piano, flush type, 16 Amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
80
-
-
... More
Sockets outlet multipurpose 2 in 1 pin, 6 and 6 Amps flush type ISI marked all as specified and directed by Engineer-in-charge
235
-
-
... More
Sockets outlet multipurpose 2 in 1 pin, 6 and 16 Amps flush type ISI marked all as specified and directed by Engineer-in-charge
80
-
-
... More
Stepped type electronic fan regulator flush type complete all as specfied and directed.
65
-
-
... More
Bell push, paino type, 6 amps, 230 volts, single pole, complete all as directed by Engineer-in-charge
25
-
-
... More
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
750
-
-
... More
Electric Bell, ding dong, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge.
45
-
-
... More
Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed.
250
-
-
... More
LED lamp 9 watts, B-22 type complete all as specified .
250
-
-
... More
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed.
150
-
-
... More
Slim LED lights fitting, 4 feet, 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
950
-
-
... More
Slim LED lights fitting, 2 feet, 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
150
-
-
... More
Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed.
1100
-
-
... More
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 4 sqmm and one single core earth cable of 4 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely
(iii) colour code shall be Red for phase, Black for neutral and green for earth
450
-
-
... More
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 6 sqmm and one single core earth cable of 6 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely
(iii) colour code shall be Red for phase, Black for neutral and green for earth
350
-
-
... More
Supply and fixing sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 10 sqmm and one single core earth cable of 10 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely
(iii) colour code shall be Red for phase, Black for neutral and green for earth
150
-
-
... More
Supply and fixing sub main wiring with Four single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by providing by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 4 single core of 10 sqmm and one single core earth cable of 10 sqmm cable shall be considered as 1 running metre. (ii) PVC conduit and cutting chases will be measured and paid separtely
(iii) colour code shall be Red for phase, Black for neutral and green for earth
150
-
-
... More
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed .
950
-
-
... More
20 to 25 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed .
840
-
-
... More
32 to 40 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed .
110
-
-
... More
Supply lying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor , served with inner sheating of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 10 Sq mm , one twin core cable flat or circualr, including taking out old service cable complete all as specified and directed.
150
-
-
... More
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed .
100
-
-
... More
MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed
30
-
-
... More
Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed .
30
-
-
... More
MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way SPN with 200 Amps busbar 240V completed all as specified and directed.
10
-
-
... More
MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed.
45
-
-
... More
MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 04 way SPN with 200 Amps busbar 240V completed all as specified and directed.
5
-
-
... More
Sheet metal enclosure for DB, flush mounted single door suitable for 2 way SPN without busbar 240V completed all as specified and directed.
10
-
-
... More
MCB, SPN , 240 volt, 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
185
-
-
... More
MCB, SPN , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
80
-
-
... More
MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
650
-
-
... More
Fixing only exhaust fan in repair and connecting up to and including provision of 2 core single flexible cable for ceiling rose/ connector to fan including clean of blade / body cover etc complete all as specified and directed.
55
-
-
... More
Hanging of ceiling fan in repair and connecting up including provision 2 core single flexible cable for ceiling rose/ connector to fan including clean of blade / body cover etc complete all as specified and directed.
150
-
-
... More
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-
(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.
(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.
(iii) Rate shall include earth lead and protection pipe of length 7.5m
(iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter
25
-
-
... More
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanised iron strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-
(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.
(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.
(iii) Rate shall include earth lead and protection pipe of length 7.5m
(iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
(v) unit rate including protection pipe and GI strip 32x 6mm from top to earth plate upto 7.5 meter
15
-
-
... More
Maintenance freee chemical earthing using 40mm dia 3.00 mtr long GI earthing electrode capsule complete, having following specification :- (a) Making a hole of 150mm dia to a depth of 3.50 mtr from GL and placing the earthing electrode inside the hole.
(b) Filling the back fill with enhancing compound of superior quality, electrogrip back fill compound qty approx 50 Kgs properly mixed, around the earthing electrode. (c) Continous compaction of backfill compound to form a uniform mixture all around the earthing electrode.
(d) Construction of brick masonry earth pit of internal size 30cm x 30cm and 30cm deep including finishing work and fixing of CI cover as per the size of the pit complete all as specified and directed
(e) Testing for proper working.
NOTE- Earth resistance at each grid should be less than 2 ohm at test point .
12
-
-
... More
LED pannel Recess mounted ultra slim 2'x2' - 36 watts edge lit tile in aluminum extruded housing with opal diffuser suitable for perfect lighting complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed.
190
-
-
... More
LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,including lamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, including taking down old street lght complete all as specified and directed.
120
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements