Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Consultancy Services
Eprocure
Opening Date21 Feb 2025
Closing Date15 Mar 2025
Tender Amount₹ 44,83,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No 3 here-in-before but for depth exc 1.5 mtr and not exc 3.00 mtr complete all as specified and directed.

10.52

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming (RFR) in layers not exc 25 cm, complete in all respect complete all as specified and directed.

171.3

-

-

... More
Removal of excavated soil/ Malwa/ Debris to a distance exc 1.5 KM and not exc 10.00 KM including loading, unloading and stacking etc as per NGT Norms complete all as specified and directed.

82.52

-

-

... More
M&L for Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area, complete in all respect as specified and directed by Engr-in-Charge.

105

-

-

... More
M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete in all respect as specified and directed by Engr-in-Charge.

150

-

-

... More
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface, complete in all respect as specified and directed by Engr-in-Charge.

105

-

-

... More
M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall, complete in all respect as specified and directed by Engr-in-Charge.

30

-

-

... More
M&L for PCC type D-2, 1:4:8 (using 40 mm nominal size crushed and graded stone aggregate) in foundations, filling and mass concret, complete in all respect as specified and directed.

11.2

-

-

... More
M&L for RCC M-25 (using 20 mm graded aggregates) design mix in foundations, including rafts, footings, foundation beams, plinth beams;bases for columns, etc.; basement slabs under-reamed piles and mass concrete, complete and all as specified and as directed by Engr-in charge.

18

-

-

... More
M&L for RCC M-25 (using 20 mm graded aggregates) design mix in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses, complete and all as specified and as directed by Engr-in charge.

34

-

-

... More
M&L for RCC M-25 (20 mm grades aggreages) design mix in columns, pillars, piers, psts and struts, complete and all as specified and as directed by Engr-in charge.

4.25

-

-

... More
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished flat surface of concrete complete in all respect as specifified and directed.

30

-

-

... More
M & L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, complete in all respect as specifified and directed.

170

-

-

... More
M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions in rough finished flat surface of concrete complete in all respect as specifified and directed.

34

-

-

... More
M&L for deformed TMT steel bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete in all respect as specified and directed.

4800

-

-

... More
M&L for deformed TMT steel bars 5 mm dia and over upto and including 10 mm dia in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete in all respect as specified and directed.

430

-

-

... More
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering, complete in all respect as specified and directed by Engr-in-charge.

60

-

-

... More
M&L for broken stone or boulders hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface.

18

-

-

... More
M&L for 100 mm thick PCC 1:4:8 Type D-2 (using 40 mm graded stone aggregate) as sub-floor etc., including rough top surface to receive tiles finish, complete all as specified and as directed.

60

-

-

... More
M&L for 100 mm thick PCC 1:2:4 Type B-1 (using 20 mm graded stone aggregate) as in floor etc., including rough top surface to receive floor finish, complete all as specified and as directed.

60

-

-

... More
Forming Contration (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade "A" complete all as specified and as directed.

4

-

-

... More
M & L for brickwork with subclass `B’ bricks, in straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge

9.5

-

-

... More
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick or concrete surfaces including finishing even and smooth without extra cement complete all as specified and as directed by Engineer in Charge.

50

-

-

... More
Supply only liquid water proofing compound complete all as specified and directed.

1.89

-

-

... More
M&L for applying two coat of exterior Acrylic emulsion paint (100% acrylic) of approved colour and shade over a coat of primer and over 1 to 2 mm thick birla putty punning including preparation of new plastered surface complete all as specified and as directed by Engineer-in-charge. (Note:-including necessary scaffolding upto 4th Storey)

50

-

-

... More
M&L for 75 mm thick PCC, type C-2, 1:3:6 (using 40 mm crushed and graded stone aggregate) as in plinth protection and finished surface even and smooth without using extra cement complete in all respect as specified and directed.

25

-

-

... More
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, tubular/hollow section, channel or flat sections) including distance pieces, cleats etc. using FE-410W (Grade E-250 quality "A") complete all as specified and directed.

550

-

-

... More
S&F plate girder or single stanchions, built up of one beam or channel section with flange plates, caps bases, splices, agnle brackets cleats and other connection confirming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.

2025

-

-

... More
S & F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment using Fe-410W (Grade E-250 quality "A") complete in all respect as specified and directed.

7.5

-

-

... More
S&F 16 to 20mm dia of neck of MS Bolt screw bolts (purpose made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.

20

-

-

... More
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.

150

-

-

... More
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge/ eves gutter covering or of similar type, fixed with self tapping screws including necessary mild steel flats and screws for fixing with framed structure complete all as specified and directed.

25

-

-

... More
M&L for applying two coats synthetic enamel paint over a coat of red oxide/zinc chrome primer including preparation of new steel/iron surfaces exc 10cm in width or girth all as specified and as directed by Engineer-in-charge.

19.8

-

-

... More
M&L for Brick work subclass “B” brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar 1:4 with old size brick complete all as specified and directed.

12

-

-

... More
M&L for PCC 1:3:6, type C2 (using 40 mm graded stone aggregates) as in drain surface channel, benching and rain water drain, complete in all respecte as specified and as directed.

1.5

-

-

... More
M & L for extra forming fair finished drain or channel any girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc for 300mm girth .complete in all respect as specified and directed.

40

-

-

... More
M&L for PCC 1:2:4, type B-0 (using 12.5 mm graded stone aggregates) as in coping including necessary form work, complete in all respect as specified and as directed by Engr-in-charge.

0.9

-

-

... More
M&L for Rendering 15mm thick in CM 1:4 on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.

74

-

-

... More
S&F Precast Cement concrete perforated drain cover of size 900mm x 450mm x 70mm thick surrounded with steel strip 70x2mm Reinforced as per manufacturer's design in Manufactured proccess laid over existing drain, complete all as specified and as directed by Engr-in-Charge.

90

-

-

... More
Supply and fixing 120 watt energy , saving environmental friendly, long life exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural features or retail spaces, including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
Material and labour for XLPE insulated armoured heavy duty electric cable with ISI Marked aluminium conductor 1100 volts grade with cross sectional area of the size 10 Sqmm 2 core complete all as specified and directed.

30

-

-

... More
M&L for cable PVC insulated FRLS unsheathed copper conductor cable of size 2.5 Sqmm 2 single core phase and neutral including 2.5 sqmm earth continuty conductor complete all as specified and directed. NOTE : PVC caping/conduit and three run of 2.5 Sqmm PVC wire will be measured separately

25

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore medium grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 10 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion complete all as specified and directed.

1

-

-

... More
Supply and fixing non transparent looping SMC kiosks pole box 2 phase of size 310×210×120 mm made out of engineering plastic one piece moulding siemens gray colour with hold fast including 2 Nos aluminium strips 60 amp of requird size fixed on unbrakable insulator and one no single pole MCB 1 to 3 amp 'C' curve including taking out of old unserviceable one, complete all as specified.

6

-

-

... More
Material and labour in replacement for point wiring (concealed) in and including rigid non metallic PVC heavy duty conduit, 19/20 mm dia/suitable size as per site reqmt including cutting chases for conduits, sinking for boxes for concealed conduit wiring with 1.5 sqmm FRLS PVC insulated unsheathed multi stranded copper conductor cable in and including flush type metal boxes modular type suitable for fixing modular switches, sockets, fan regulators etc with brass screw, cup washer and including PVC insulated unsheathed multi stranded copper conductor cable of 1.5 sqmm as earth wire connected to common earth and earth dolly as per IS specification and as specified for the One light/fan/bell point controlled by one switch.

6

-

-

... More
All as per item No-48 here-in-before but for one 3 pin socket outlet 5 Amps, independent board.

2

-

-

... More
All as per item No-48 here-in-before but for one 3 pin socket outlet 5 Amps,on the same board.

2

-

-

... More
All as per item No-48 here-in-before but for one 3 pin socket outlet, 15 Amps, on the independent board with cables 4.0 Sqmm.

2

-

-

... More
M&L for concealed sub main wiring alongwith earth wire,concealed in walls/ floors or fixed in wall/ceiling, including the cutting of chases and provision of PVC conduit (heavy grade), and making good to surface to match the original surface, with the following sizes of FRLSH PVC insulated unsheathed copper conductor, single core cable in PVC conduit (Heavy grade) of size 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire complete all as specified and directed.

30

-

-

... More
M&L for modular switch 1 way, 6A, 1 module complete all as specified and directed.

10

-

-

... More
M&L for modular switch 1 way, 16A, 1 module complete all as specified and directed.

2

-

-

... More
M&L for socket, modular, 6A-2/3 pin combined, 2 module complete all as specified and directed.

4

-

-

... More
M&L for socket, modular, 6A/16A -2/3 pin combined, 2 module complete all as specified and directed.

2

-

-

... More
M&L for ceiling rose 63.5x23.5 mm 3 terminals, PVC/Polycarbonate, isolated body complete all as specified and directed.

6

-

-

... More
M&L for modular white cover plate with frame, 6 module complete all as specified and directed.

1

-

-

... More
M&L for modular white cover plate with frame, 3 module complete all as specified and directed.

4

-

-

... More
M&L for modular metal flush box, 6 module complete all as specified and directed.

1

-

-

... More
M&L for modular metal flush box, 3 module complete all as specified and directed.

4

-

-

... More
S&Fsheet metal eoclosure for DBs when MCBs to be used single pole neutral 8 way, double door 415 V rating complete all as specified and directed.

1

-

-

... More
S&F MCB, islolator , breaking capacity min 10KA,'C' curve 230V, 40 Amps complete all as specified and directed.

1

-

-

... More
S&F MCB, SP, breaking capacity min 10KA,'C' curve 230V, 5 to 32 Amps complete all as specified and directed.

6

-

-

... More
Supply and fixing air termination single pointed aluminium rod 12 mm dia and 300 mm long

2

-

-

... More
Supplying and fixing aluminium strip 25 x 3.15 mm with sadles and fixing screws etc for roof conductors and down conductors above groundcomplete all as specified and directed.

55

-

-

... More
Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hex. Head screw complete all as specified and directed.

2

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore light grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 8 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh, 20 mm bore galvanised iron pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion complete all as specified and directed.

2

-

-

... More
Supply and fix steel tubular swaged poles type 410 SP-22 (12 meter long) complete with CI base plate and final including foundation and coping complete all as specified and directed.

2

-

-

... More
Supply, installation, testing and commissioning of Isolation Transformer, 3 Phase, 50 Hz, indoor type, Copper Wound, Oil cooled, Class of insulation A, metallic body powder coated designed for Input Voltage range 415V,+ - 5% and Output Voltage range 415V, + - 5%, with ratio of 1:1, Vector Group : Dyn 11, Delta - Star with first filling of transformer oil of requisite dielectric strength up to level, efficiency more than 95%, separate neutral bushing shall be brought out for earthing. Potential difference between neutral to earth less than one volt with all standard fittings like, digital temperature meter, lifting hooks one set, Earthing terminals two nos of capcity 30 KVA complete all as specified and directed.

1

-

-

... More
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size , platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :-

1

-

-

... More
INCOMING (a) MCCB, four pole, 400 Amp, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 No.(b) 600 Amps rated copper bus bar suitable for 04 pole system - 01 No. (c) Phase indicating lamp RYB LED type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with integeral selector switch dully prewired. (e) Ammeter Digital type 0-320 Amp capacity with integeral selector switch and CT coils of suitable capacity 300/5A dully prewired. (f) Changeover Switch 400 Amps , 04 pole suitable for 415 volt AC Supply OUT GOING (a) MCCB four pole 250 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 Nos . (b) MCCB four pole 200 Amps, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 02 Nos .

-

-

-

... More
Supply, install commissioning and testing cubical out door feeder LT panel board of suitable size , platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete supported on angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete including necessary PCC 1:2:4 foundation and necessary electrical connection of incomming and outgoing cable with necessary lugs complete all as specified and directed. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables :-

1

-

-

... More
INCOMING (a) MCCB, four pole, 200 Amp, 36 KA at 415 Volts, adjustable thermal and magnetic setting- 01 No. (b) 400 Amps rated copper bus bar suitable for 04 pole system - 01 No.(c) Phase indicating lamp RYB LED type (Set of three ) -01 Set (d) Voltmeter Digital type 0-500 Volts capacity with integeral selector switch dully prewired. (e) Ammeter Digital type 0-320 Amp capacity with integeral selector switch and CT coils of suitable capacity 300/5A dully prewired. OUT GOING (a) MCCB four pole 160 Amps, 16 KA at 415 Volts, adjustable thermal and magnetic setting- 02 Nos . (b) MCB TP 63 Amp capacity , 10 KA at 415 volts adjustable -01 Nos (c) MCB SP 16 to 32 A suitable for 240 volts-01 Nos (b) Spare Box suitable for fixing of MCCB - 01 Nos .

-

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron strips 32 x 6 mm by means of nuts both check nuts and washers made of galvanised iron or steel earth strip protected by galvanised iron pipe 40 mm bore light grade upto ground level as directed and including concrete pit in PCC ( 1 : 3 : 6) type C1 pre cast RCC cover slab 30 cm x 30 cm x 8 cm thick including reinforcement with 8 mm dia steel deformed bars at the rate of 10 cm both ways with one lifting handle made of 8 mm dia MS bar funnel, wire mesh, 20 mm bore galvanised iron pipe medium grade for watering charcoal on coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Pt-I and testing on completion complete all as specified and directed.

8

-

-

... More
Supply, laying, testing and commissioning LT UG armoured, XLPE insulated, inner and outer sheathed, PVC insulated with multi stranded aluminium conductor cable of cross sectional area 95 Sqmm x 3.5 Core, 1100 volts grade, ISI marked with IS-7098, laid in trenches/floor/duct/wall including aluminium lugs of suitable sizes complete all as specified and as directed.

300

-

-

... More
Supply, laying, jointing and testing in replacement of HT XLPE insulated ,screened,PVC bedded galvanised steel strip or wire armoured ,electric power cables(heavy duty) with aluminium conductor,11000 volts(earthed) , grade cross sectional area 150 sqmm 3 core for working voltage upto 11000 Volts, including cable lugs for providing connections as in repair complete all as specified and as directed.

290

-

-

... More
Boring of holes under road, pavement, hard standing for more than 5 mtr in length by trenchless, technology using ultra sound technique and necessary machine, including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure.

20

-

-

... More
M&L for cutting the existing bitumen us road/payment/footpath upto 0.75 mtr in depth, 0.45 mtr in width and getting out excavated material and making good the damaged portion after laying the pipe, returning filling in mass concrete PCC 1:2:4 type B2 upto top of the road all as directed by Engr-in-Charge. Note :-M&L for laying of pipe shall be measured and paid separately.

6

-

-

... More
M & L for chemical earthing complete with copper plate earth electrode 20mm dia and 03 mtr long thick buried directly in ground (earth pit not less than 4.00 mtr below ground level with top edge of plate not less than 3.25 mtr below ground level) brazed with copper strip 50x6 mm size 7.5 mtr long and connected to copper strip of any size by means of copper bolts, nuts, check nuts and washers complete all as specified and directed. Note:- The rated quoted is deemed to the inclusive of the followings:- (a) The excavation and earth work (filling in, ramming in layers, watering etc as directed) in any type of soil for earth pit (pit size 1.20x 1.20x4.0mtr). (b) Perforated GI tubing (ISI marked) light grade 80mm bore 7.0 mtr long for strip protection and watering. (c) Common salt charcoal dust in alternative layers of 15cm, up to 90cm above the top of copper plate and one layers of 15cm Magnesium sulphate (MgSo4) all as directed (Salt - 500Kg, Charcoal dust - 1000 Kg & MgSo4 - 150 Kg). (d) Earth chamber of internal size 600mmx600mmx600mm, built in PCC (1:3:6) type C2 bed 15cm thick at bottom, brick work in CM 1:6 upto 45cm over PCC bed and PCC (1:3:6) type C1 coping 15cm above, embedded with MS angle 50mmx50mmx3mm frame work duly painted with anti corrosive bituminous paint, with and including RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with XPM (weight not less than 4Kg per Sqm) having lifting arrangement duly painted in green and making earth pit as directed. (e) On testing, after completion, if the earth resistance 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained. (f) GI tubing, bib tap etc for provisioning of continuous water supply at earthing pit will be measured and paid seperately under respective schedule of the contract.

4

-

-

... More
M& L for test point terminal block made out of gun metal or phosphorous bronze of size 75x75x25 mm drilled & screwed including 3 hole,8mm dia 25mm long hexagonal head with nuts & washers complete as specified and directed.

4

-

-

... More
M & L in replacement of testing point box of size 100 x 100 x 50 mm depth as per sample complete all as specified.

4

-

-

... More
Supply and fix in replacement of Copper Strip of size 50 X 6mm buried/laid in trenches/fixed on wall/tower etc complete all as specified.

100

-

-

... More
S&F in replacement of 15 mm bore GI tubing, medium grade ISI marked galvanized with all fitting and laid in trenches complete all as specified and directed.

15

-

-

... More
S&F in replacement gun-metal, globe or gate valves, with iron wheel head, screwed both ends to iron pipe and fixed to 15 mm bore pipe complete all as specified and directed.

2

-

-

... More
M & L for copper brazing with copper strip/copper rod complete all as specified and directed.

4

-

-

... More
Supply & Fix in replacement of PVC insulator supporter with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls/PCC blocks etc complete all as specified and directed.

10

-

-

... More
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregates for filling in road cuts/hard standing etc complete all as specified and directed.

5

-

-

... More
Removing excavated material soil n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed.

55

-

-

... More
Supply and laying reinforced precast concrete cable cover, class HV,type 1,flat ,size 300 mm X 180mm X 40 mm of approved make complete all as specified and as directed.

1300

-

-

... More
M&L for sand filling in trenches for cushioning of cable complete all as specified and directed.

35

-

-

... More
Material and labour for fly ash/burnt Bricks, sub class 'B' dry, well brunt bricks laid in trenches for cable protection complete all as specified and directed.

3.6

-

-

... More
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm ISI marked complete all as specified and directed.

2

-

-

... More
Schedule of Credit

-

-

-1500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.