Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Drainage Work
Pipe Line Project
Eprocure
Opening Date17 Oct 2024
Closing Date14 Nov 2024
Tender Amount₹ 48,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Cleaning of septic tank size 6m x 4m by opening cover, pumping out sewage water and taking out accumulated nigt soil, sludge, brick bats or any other items, (both solid and liquid) through browser with Tractor and removing the same out of defence land and placing the septic tank cover on the same opending complete al as specified and directed by Engr-in-Charge. Note:- 1. Excavation of pit and removal of surplus soil is deemed to be included in unit rate. 2. Bleaching powder to be spread over and all around of buried night soil/sludge.

20

-

-

... More
All as item No 4 here -in- before but of size 4Mx3M.

30

-

-

... More
Cleaning of manhole exc 0.5m length but n exc 1.5 mtr deep by dewatering by machanically/manually and taking out sludge, silt, mud, brickbats etc removing the same out of defence land and placing the manhole covers on the same opening complete all as specified and directed by Engr-in-charge .

700

-

-

... More
All as item No 6 here -in- before but exc 1.5m but n exc 4.5 mtr

80

-

-

... More
All as item No 6 here -in- before but exc 4.5 m but n exc 6.0 mtr

50

-

-

... More
All as item No 6 here -in- before but exc 6.0 m but n exc 9.0 mtr

45

-

-

... More
All as item No 6 here -in- before but exc 9.0 m but n exc 15.0 mtr

40

-

-

... More
Sucking out sewage water through sewage tanker from the man hole/septic tank/ soakage well in different location and disposal (5000 ltr capacity) by using high pressure super sucker machine vehicle mounted jetting cum suction unit to be capable of air lefting of dense waste/ sludge like mud slurry, small stoes, debries, grit etc from sewer lines, through vacuum mode and capable of jettig sewer lines of dia 150mm to 450mm incl skilled driver and operator for supervising of cleaning of sewage line and also required sludge/silt/mud/debries etc of out of MD land as directed by Engr-in-charge. Note:- Pumping and Loring rates are include in this item .

550

-

-

... More
Cleaning of soil/waste pipe 75mm to 250mm dia by rodding,pumping without disturbing joints and clamp from 1st floor to ground floor and refixing the Nahani trap grating and all as directed by Engr-in-charge.

1000

-

-

... More
Checking/Cleaning of blockage of WC, WHB, Sink, Traps, Nahani Traps, soil waste pipe etc by mannual, roddingh, using wire, vaccume section as suitable and removal of waste at distance 1 Km and above and depositing of the waste in a pit burried and covered with earth and refix in same position of grating with white cement all as sper directed by Engr-in-Charge( the work has to be carried out reguler/daily basis for proper functioning of sewage system)

900

-

-

... More
Cleaning of open drains having inner girth width upto 0.60m and depth upto 1.2 mtr by removing mud, sludege silt, garbage, debries, sludge, vegitation etc and 1 mtr both side of drain also clear as vegitation and levelling the earth work and removing debrish by manually or machanically form out of MoD land complete all as specified and directed by Engr-in-Charge

2500

-

-

... More
M&L for Up rooting of trees and accumulated mud and grass around on top of roof and wall by dismantling brick works in any mortar and mix PCC plastered surface of any description not exc 30 cm girth of trees and disposal of unserviceable material to a distance n.exc 50M including and making good to match with existing surface of double storey with necessary scaffolding complete all as specified and as directed.

300

-

-

... More
Taking down and refixing of wash basin, EWC, IWC, urinal, Sink with drainage board etc incl white cement and gas kit complete all as specified and as directed by Engineer-in-Charge.

70

-

-

... More
S&F in repairs, Precast Cement concrete manhole/drain cover of size 1200mm x 600mm x 70mm thick srounded with steel strip 70x1.25mm Reinforced as per manufacturer's design in Munufactured proccess laid over existing drain complete all as specified and as directed by Engr-in-Charge. Make of SFRC Manhole/drain cover and frame : (a) M/s PS Concrete. (b) M/s KK Manhole.(c) SS Or equivalent as approved by GE. (ii) Contractor shall provide PV alongwith manufacturer test certificate of SFRC cover.

600

-

-

... More
All as per item No 17 here-in-before but 750x600x70.

100

-

-

... More
All as per item No 17 here-in-before but 600x500x70.

50

-

-

... More
Demolition/Breaking up Drain Pipes (Salt Glazed Ware) 150mm Bore (dia), Jointed in Cement Mortar of any description including PCC of Packing and Haunching to Sides of the Pipes with Bed, complete all as specified and as directed.

200

-

-

... More
Excavating in trenches, not exc. 1.50m wide and not exc. 1.50 m in depth, for foundation of sewage lines and manhole, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.

300

-

-

... More
All as per item No 21 hereinbefore but depth exceeding 1.5 m and not exceeding 3.00M -ditto-.

300

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and as directed.

560.25

-

-

... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.

39.75

-

-

... More
S&F of Reinforced cement concrete drain Pipes 150 mm dia NP-2 , laid in trenches in foul condition, Jointed with collars in cement mortar 1:2 and tested, complete all as specified and as directed.

200

-

-

... More
M&L for Cutting into existing Manhole for removing existing Branch Drain Pipes, Making Good to Brick Wall and Rendering, cutting out Branch Channel and making good in Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) and reforming Benching for 150mm internal dia Drain Pipe in Foul Condition, complete all as specified and as directed.

15

-

-

... More
M&L for cement concrete 1:3:6 (20mm Graded crushed stone aggregate) Bed for drain pipes of bore 150mm including packing under and haunching against the sides of pipes after they are laid in foul condition and testing, complete all as specified and as directed.

200

-

-

... More
Dismantling of damaged RCC Works (Cover Slab of Manholes Septic Tanks or Similar Articles) of any description and in any Position, complete all as specified and as directed.

6

-

-

... More
M&L for Pre-Cast Factory made RCC 1:1.1/2:3 (20mm Graded crushed stone aggregate) as in cover slab of manholes, septic tanks or similar articles with plain faces and set in Cement Mortar 1:4, including form work & renfoced with 8mm dia TMT steel 100mm c/c both way, complete all as specified and as directed.

6

-

-

... More
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.

95

-

-

... More
M&L for Brick work with sub-Class ‘B’ bricks (with old size bricks), straight or curved on plan exc. 6m mean radius, built in cement mortar 1:4, complete all as specified and as directed.

90

-

-

... More
All as per srl item No. 31 here in before but except bricks Note:- Serviceable bricks obatined from srl item No. 30 shall be re-used in srl item No. 32 after cleaning etc complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate as in coping and similar works including necessary form work complete all as specified.

2

-

-

... More
M&L for PCC 1:3:6 type C-2 using 40mm crushed graded stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed.

3

-

-

... More
Taking down Cement Plaster, any description on brick walls or on concrete surfaces including raking out Joints, hacking for key, scrubbing down with Water, etc., and removing same from the Site(s), complete all as specified and as directed.

1000

-

-

... More
M&L for Rendering 15mm thick on any face of brick work in cement mortar 1:4, finished plastered surfaces even and smooth without using extra cement, complete all as specified and as directed. (WPC measured and paid separetly)

1350

-

-

... More
Cleaning and removing all scale and dirt, etc, from Overhead tank (R.C.C./PVC) and from mouths of circulating pipes etc capacity exc 250 and not exc 500 Ltr each (Note - Over head tank cleaning each quarter/ two time in contract period) Date of cleaning in white paint to be marked on the tank in 50 mm ht letters.complete all as specified and as directed by Engineer-in-Charge.

250

-

-

... More
Cleaning and removing all scale and dirt, etc, from Overhead tank (R.C.C./PVC) and from mouths of circulating pipes etc capacity exc 500 and not exc 1000Ltr each (Note - Over head tank cleaning each quarter/ two time in contract period) Date of cleaning in white paint to be marked on the tank in 50mm ht letters.complete all as specified and as directed by Engineer-in-Charge.

102

-

-

... More
M&L for Rendering 15mm thick on inside face of of brick work in cement mortar 1:3 in manhole, finished plastered surfaces even and smooth with using extra cement, complete all as specified and as directed.(WPC measured and paid separetly)

200

-

-

... More
Supply only water proofing compound ISI marked complete all as specified and as directed.

20

-

-

... More
M&L for providing cement concrete type B-I , 1:2:4 (using 20 mm graded crushed stone aggregate) as in channels , roof kerbs or mud stops, rounded or chamfered on edges complete all as specified

10

-

-

... More
M&L for salt glazed stone ware gully traps square or rounded mouthed type ‘P’ of size 150x150mm embedded in PCC 1:3:6 type C-1 with and necessary brick work, plastering etc complete and connecting to pipe all as directed by Engineer-in-charge.

25

-

-

... More
Dismantling of cast iron , concrete, asbestos, PVC pipes of any dia and discription from trenches or with walls etc complete all as specified.

200

-

-

... More
M&L for 110mm dia PVC ( SWR) pipes, single socketed, in any length with rubber ring, joints, laid in trenches or in floors fixing and repair etc all specifid and directed.

160

-

-

... More
M&L for PVC (SWR) bends of 110mm radius with rubber ring, joints, laid in trenches or in floors fixing and repair etc all sped and directed.

15

-

-

... More
S&F for 100 mm dia cast iron spun soil, waste and vent pipes , in any length with or without ears, with cement joints, laid in trenches or in floors and fixed to walls as in repair complete all as specified and directed.

20

-

-

... More
S&F for 75 mm dia cast iron spun soil, waste and vent pipes , in any length with or without ears, with cement joints, laid in trenches or in floors as in repair complete all as specified and directed.

20

-

-

... More
S&F for 100 mm bore Bends (any radius) with oval access door diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.

5

-

-

... More
S&F for 75 mm bore Bends (any radius) with oval access door diminishing pieces or tapers (larger bore measured) complete all as specified and as directed.

5

-

-

... More
M&L in repair stack clamps for 100 bore pipe as in repairs out of 50mm by 5mm flat iron and 16mm dia round iron stays incl bolt and nuts and securing end of stays to wall or roofs complete all as specified and as directed.

10

-

-

... More
S&F in repairs vitreous china coloured half stall urinal brass chromium plated brackets , fitting and waste coupling, CP bottle trap , urinal spreder , PVC connection etccomplete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
S&F in repair for vitreous china wash basin white flat backsize 600x480 including cutting for and pinning in ends of brackets including fixing of 32 mm low dencity polylethyne pipes (LDPE) of pressure rating 6kg/cm2,cupling ,PVC connection with 15 mm dia PTMTcheknuts ,brackets all complete all as specified and as directed by Engineer-in-Charge.

18

-

-

... More
S&F in repairs vitreous China squatting pan 'orrisa' pattern white colour of size 580x440mm with integral foot rests including provision of lime concrete including P traps complete all as specified and as directed by Engineer-in-Charge.

15

-

-

... More
S&F in repair wash down water closet (pedestal pattern) of any colour including fixing of bolts complete all as specified and as directed by Engineer-in-Charge.

10

-

-

... More
Dismantling of mild steel work of any description not other wise provided of all as direted by Engr-in-Charge.

27

-

-

... More
M&L for framed work such as grills, gratings,post of angle iron etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed by Engr-in-Charge. Note:- Work shall be executed in Drain jali work .

2700

-

-

... More
S&F welded mesh steel fabric cut to length bent to shape weight not exc 4 Kg/Sqm including welding and fixing arrangement as in repair, complete all as specified and as directed.

500

-

-

... More
S&F repair in of PTMT waste pipe 31/32 mm bore 80 cm long complete all as specified and as directed by Engineer-in-Charge.

80

-

-

... More
S&F in repair bib taps 15mm bore long body (for iron pipe) cast copper alloy fancy type chormium plated butter fly handle screwed down complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S&F in repair pillar taps 15mm bore cast copper alloy fancy type chormium plated butter fly handle screwed down including complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S&F in repair angle/ stop valves 15mm bore (for iron pipe) fancy type chromium plated screwed down high pressure with butterfly handle screwed both ends complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S&F in repair aluminium alloy door seal 1m long fixed to wooden doors complete all as specified and as directed by Engr-in-Charge.

40

-

-

... More
S&F in repair PTMT waste coupling 31/32mm bore of discharge (Half or full threaded) Min weight 45 gms, complete all as specified and as directed by Engineer-in-Charge.

80

-

-

... More
M&L for 6 to 8 mm dia TMT bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips

200

-

-

... More
All as per item No 66 here-in-before but in stirrups/binders complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) all as directed by Engr-in-Charge

60

-

-

... More
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5 cm but n exc 15 cm wide all as specified and directed by Engr-in-Charge

260

-

-

... More
M&L for reinforced cement concrete (nominal mix) type B-1 1:2:4 (using for 20 mm thick crushed stone aggregate) in slabs supported on walls, bends, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc all as specified and directed by Engr-in-Charge

4

-

-

... More
S&F in repair one piece square model water closet floor mounted Square Commode (White) S trap - white ceramic western commode (white) shape-Elongated type, size 685x360x720mm weight not less 20 Kg 'S' trap and slim seat cover & fitting as per Cera Cat Part No S1013164 or equivalent complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Dismantling of wall/ floor tile including backing coat any description or any thickness beded and pointed in any cement motar and removal to out of MD land all as specified and directed by Engr-in-Charge

104

-

-

... More
M&L non skid ceramic coloured tile 7 to 8mm thick (square/rectangular area of each tiles exceeding 0.11 Square but not exceeding 0.18 Sqm in floor over 10mm thick screed bed in cement motar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the tile all as directed by Engr-in-Charge.

50

-

-

... More
M&L for 10 mm thick glossy finsih for parking/ path (squar / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and jointed in white/coloured cement to match over and including 10 mm thick screed bed in cement mortar in 1:4, complete all as specified and as directed by Engr-in-charge.

54

-

-

... More
M&L glossy chequered cement concrete tiles 300x300x25mm thick, set jointed and pointed in near cement slurry in floors with white cement and pigments in any colour machine preassed glazed , over cement screed bed 15mm thick cement motor 1:6 all as specified and as directed by Engr-in-charge.

70

-

-

... More
M&L for 60mm thick rubber moulded Machine pressed pre casted pressed cement concrete inter locking paver blocks glazed coloured up to 6mm on the top in any shape and size, strength not less than M-35 incl 25mm thick sand cushioning completed all as specified and as directed by Engr-in-Charge.

70

-

-

... More
Demolition in cement concrete in any description and any position not other wise specified and provided as in ground floor and paving nexc. 15 cm thickness (below above ground floor) all as directed by Engr-in-Charge.

14.5

-

-

... More
M&L providing 75mm thick cement concrete 1:4:8 type D-2 using 40mm graded aggregate in sub base of floor complete all as specified and directed by Engr-in-Charge.

140

-

-

... More
M&L 100mm thick Cement concrete type B-2,1:2:4 , 40 mm graded stone aggregate as in path , near sewage line, drain etc. finished even smooth with broom finished w/o using extra cement, laid in alternate bays all as directed by Engr-in-charge

40

-

-

... More
M&L machine cut broken stone of gauge not exc 63mm as in hard core n exc 150mm thick sprdded and levelled including watering & ramming all as directed by Engr-in-Charge.

4

-

-

... More
Dismantling of PVC drain pipes 200mm dia and discription from trenches or walls etc complete all as specified.

200

-

-

... More
M&L for 200mm dia PVC pipes, single socketed, in any length with rubber ring, joints, laid in trenches or in floors and fixing to walls including bend, clamps or other fittings all specified and directed.

200

-

-

... More
Note:- The amount of Rs 106430/- against Schedule of Credit on Page No 135 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.