Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_667210_3Bid Award Id
ViewTender No
GE/CHM-62/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply only Integral waterproofing compound, all as specified.
550
-
-
... More
15mm thick rendering in Cement and Sand mortar 1:4 over concrete /brick surfaces finished fair and even without using extra cement (upto 4 Storey Bldg ), providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
2050
-
-
... More
10mm thick rendering in Cement and Sand mortar 1:3 on ceiling, chajja surfaces (concrete surfaces)finished fair and even without using extra cement, as in ceiling, chajjas, facias, at any position, providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
100
-
-
... More
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
5
-
-
... More
Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:6, complete all as specified and directed.
5
-
-
... More
Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.
750
-
-
... More
Preparation of new plastered surfaces of walls and applying two coats of cement base paint (any colour) including all necessary scaffolding and safety arrangements, complete all as specified and directed.
2000
-
-
... More
Preparation of old surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed.
250
-
-
... More
Preparation of old surfaces of walls and applying two coats of cement base paint, up to height of 04 storey building including necessary scafolding and safety arrangements complete all as specified and directed
250
-
-
... More
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and directed.
1
-
-
... More
Plain cement concrete type B-0, 1:2:4 using (12.5 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed.
1
-
-
... More
Demolition of reinforced cement concrete in roofs, floors (other than ground floor), beams, staircase, landing, chajjas, shelves and similar suspended work, including cutting of reinforcement to facilitate demolition and removal of debris , complete all as specified and directed.
2
-
-
... More
Reinforced cement concrete, type A-1, 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in chajja and the like, complete all as specified and directed (reinforcement shall be measured and paid for separately).
2
-
-
... More
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
20
-
-
... More
Mild steel high strength deformed TMT bar 6-8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
150
-
-
... More
PVC (SWR) rain water pipe, 160mm bore, single socketed in any length with rubber ring joints, fixed to walls with PVC Clamp including nuts bolts etc, fixed as in repair complete all as specified and directed.
60
-
-
... More
160mm bore PVC (SWR) bends any radius, fixed as in repair complete all as specified and directed.
12
-
-
... More
PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed.
60
-
-
... More
110mm bore PVC (SWR) bends any radius , fixed as in repair complete all as specified and directed.
12
-
-
... More
Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar including removal of any existing treatment including mud phuska complete all as specified & directed.
450
-
-
... More
40mm thick brick tiles over and including 20mm thick Cement mortar 1:4 joints, grouted & pointed flush as the work proceeds mixed with crude oil 5% by wt of cement complete all as specified and directed.
180
-
-
... More
All as per item No 24 here-in-before but except tiles.
270
-
-
... More
Plain cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in roof padding, roof kerbs of mud stops, rounded or chamfered on edges usingincluding necessary form work, complete all as specified and directed.
21
-
-
... More
Material and labour Rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair in cement mortar (1:4), inclunding using water proofing compound complete all as specified. Note : WPC shall be measured and paid separately.
450
-
-
... More
Taking down cement plaster of any descruption on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc including removing all debrish from defence land complete all as specified and as directed.
2100
-
-
... More
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions complete all as specified & directed.
450
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements