If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 92,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_588883_2Bid Award Id
ViewTender No
CA NO GE U AMB T 03 OF 2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per Srl item No 1 here-in-before but of capacity 20 HP
6
-
-
... More
All as per Srl item No 1 here-in-before but of capacity 7.5 HP to 10 HP
8
-
-
... More
All as per Srl item No 1 here-in-before but of capacity 3 HP to 5 HP
4
-
-
... More
Note for item No 1 to 6:- (a) The replaced parts of pump shall be measured & paid separately here-in-after as supply only as fixing is inclusive in the rate quoted for the item.
(b) Dewatering of sewage well shall be included in the quoted rate of item.
(c) Contractor have to arrange all safety equipments for works in sewage well at his own cost as directed by Engr-in-Charge.
(d) Note: Serviceable sewage pump should be fitted within 12 Hrs otherwise a penalty of Rs 5000 per day will be imposed.
-
-
-
... More
Taking out old unserviceable lubricating oil from the chamber, cleaning and refilling the fresh lubricating oil complete all as specifed & directed by Engineer-in-Charge.
270
-
-
... More
Rewinding of motor 60HP non clog submersible sewage pumping set with suitable size and proper guage of winding wire using best quality of insulation material provided with thermal switches for protection against excessive temp free and replacing O ring set full fastner set, Nitrile O ring and bearing, seals and varnish the motor using fine quality varnish complete all as specified & directed by Engineer -in- Charge.
3
-
-
... More
All as per Srl item No 8 here-in-before but of pump motor 40 HP.
5
-
-
... More
All as per Srl item No 8 here-in-before but of pump motor 30 HP.
4
-
-
... More
All as per Srl item No 8 here-in-before but of pump motor 20 HP.
6
-
-
... More
All as per Srl item No 8 here-in-before but of pump motor 7.5 to 10 HP
8
-
-
... More
All as per Srl item No 8 here-in-before but of pump motor3 to 5 HP
4
-
-
... More
Supply only CI impeller with guide bush suitable for 60HP Non clog submersible sewage pumping set complete all as specified & directed by Engineer-in-Charge.
2
-
-
... More
All as per Srl item No 14 here-in-before but cap of pump 40 HP.
2
-
-
... More
All as per Srl item No 14 here-in-before but cap of pump 30 HP.
2
-
-
... More
All as per Srl item No 14 here-in-before but cap of pump 20 HP.
4
-
-
... More
All as per Srl item No 14 here-in-before but cap of pump7.5 to 10 HP.
3
-
-
... More
Supply only lubricated upper/lower bearing for 60 Hp non clog submersible pump complete all as speicified & directed by Engineer-in-Charge.
3
-
-
... More
All as per Srl item No 19 here-in-before but 40 HP
5
-
-
... More
All as per Srl item No 19 here-in-before but 30 HP.
4
-
-
... More
All as per Srl item No 19 here-in-before but 20 HP.
6
-
-
... More
All as per Srl item No 19 here-in-before but 7.5 HP to 10 HP.
8
-
-
... More
All as per Srl item No 19 here-in-before but 3 to 5 HP.
4
-
-
... More
Supply only hard metal double upper and lower mechanical seal assesbly combination for non clog submersible pump, of capacitor 60 HP complete all as specified & directed by Engineer-in-Charge.
3
-
-
... More
All as per Srl item No 25 here-in-before but cap of pump 40HP
5
-
-
... More
All as per Srl item No 25 here-in-before but cap of pump 30HP
4
-
-
... More
All as per Srl item No 25 here-in-before but cap of pump 20 HP
6
-
-
... More
All as per Srl item No 25 here-in-before but cap of pump 7.5/10 HP
8
-
-
... More
All as per Srl item No 25 here-in-before but cap of pump 3/5 HP
4
-
-
... More
Supply and fixing in replacement CI auto coupling of size 100 mm dia from sewage well of size depth 10 Mtr and 9 Mtr dia.
10
-
-
... More
Supply and fixing in replacement CI auto coupling of size 150 mm dia from sewage well of size depth 10 Mtr and 9 Mtr dia.
7
-
-
... More
Supply and fixing in replacement CI auto coupling of size 250 mm dia from sewage well of size depth 10 Mtr and 9 Mtr dia.
5
-
-
... More
Supply and fixing in replacement CI duck foot bend of size 100 mm dia from Sewage Well of size depth 10 Mtr and 9 mtr dia.
10
-
-
... More
Supply and fixing in replacement CI duck foot bend of size 150 mm dia from Sewage Well of size depth 10 Mtr and 9 mtr dia.
7
-
-
... More
Supply and fixing in replacement CI duck foot bend of size 250 mm dia from Sewage Well of size depth 10 Mtr and 9 mtr dia.
Note for item No 31 to 36:- Dewatering of Sewage well is included in Quoted rate if required.
5
-
-
... More
Supply and fix in replacement PVC insulated submersible copper cable flat/round of size 6 Sqmm 3 core complete all as specified & directed by Engineer-in-Charge
250
-
-
... More
All as per Srl item No 37 here-in-before but 10 Sqmm 3 core.
350
-
-
... More
All as per Srl item No 37 here-in-before but 16 Sqmm 3 core.
400
-
-
... More
S&F in replacement CI column pipe both end flanged ISI marked of size 100mm dia including lowering down the column pipe including dewatering of sewage well if required complete all as specified & directed by Engineer-in-charge.
120
-
-
... More
All as per Srl item No 40 here-in-before but 150mm dia CI pipe.
180
-
-
... More
All as per Srl item No 40 here-in-before but 250 mm dia CI pipe.
60
-
-
... More
Supply and fix in replacement MS adjustable spiral bottom plate suitable for 40 to 60HP Motor complete all as specified & directed by Engineer-in-Charge.
3
-
-
... More
All as per Srl item No 43 here-in-before but for size 20 to 30 HP motor.
5
-
-
... More
All as per Srl item No 43 here-in-before but for 7.5 HP to 10 HP motor.
4
-
-
... More
Supply and fix in replacement shaft AISI-410 suitable for 20 to 30 HP Motor.
4
-
-
... More
All as per Srl item No 46 here-in-before but suitable for size 40 to 60 HP motor.
2
-
-
... More
Supply and fix in replacement MS hexagonal nut and washers MS Steel eye Bolts, Allen Screws etc ISI Marked.
20
-
-
... More
S & F in replacement Rubber gasket 150mm dia ISI marked complete all as specified & directed by Engineer-in-Charge.
10
-
-
... More
All as per Srl item No 49 here-in-before but 100 mm dia.
5
-
-
... More
S & F in replacement profile gasket (MS bracket) 100mm dia ISI marked suitable for non clog submersible pump complete all as specified & directed by Engineer-in-Charge
4
-
-
... More
M&L PCC foundation of size 75cmx75cmx20cm with PCC 1:2:4 type B-1(ushing 20mm graded crushed store aggregate) including 8mm thick frame base plate of size 40cmx40cm suitable for 40 to 60HP Non Clog Submersible Pump including self drill bolt of size 150mm long and 15mm dia of shank fully threaded 04 Nos made of stainless steel complete all as specified & directed by Engineer-in-Charge.
Note : The platform shall be constructed in sewage well of approximate 12mtr deep including dewatering if required and the contractor shall quote rate keeping in view the depth of sewage well and dewatering.
22
-
-
... More
S & F in replacement CI sluice Valve PN 1.6 with SS Steel spindle and CI wheel ISI Marked of Size 100mm complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
All as per Srl item No 53 here-in-before but 150 dia.
6
-
-
... More
All as per Srl item No 53 here-in-before but 200 dia.
4
-
-
... More
All as per Srl item No 53 here-in-before but 250 dia.
4
-
-
... More
Supply fix and testing in replacement of Non Return Valve 250 mm dia PN 1.6, connected with two end flanges suitable for connecting with Pipe, nut-bolts etc including taking down old unserviceable one complete with flanges nut - bolts etc all as specified and directed.
4
-
-
... More
All as per Srl item No 57 here-in-before but 150 mm dia.
6
-
-
... More
All as per Srl item No 57 here-in-before but 100 mm dia.
6
-
-
... More
S & F in replacement MS Nut, bolts and washers of size 5/8"x3", 5/8"x4" long complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
Supply and fixing in replacement Heavy duty fully automatic star-delta starter for Non clog Sewage submersible pump set of capacity 40 HP, 415 V, 50 Hz ,3 Phase, with suitable rating of contactor, overload relay range, with single phase protection complete all as specified and directed by Engr-in-Charge.
5
-
-
... More
Supply and fixing in replacement Heavy duty fully automatic star-delta starter for Non clog Sewage submersible pump set of capacity 30 HP, 415 V , 50 Hz ,3 Phase,with suitable rating of contactor, overload relay range, with single phase protection with Ammeter Voltmeter complete all as specified and directed by Engr-in-Charge.
3
-
-
... More
S&F in replacement BOCR 3EZ thermal over load relay 05-60 Amps,415 volts , 50 Hz complete all as specified and directed by Engr-in-charge.
Note:- Contractor have to install BOCR Relay in starter with in 45 days after accepting of tender otherwise Rs 20000 /- per item will be recovered from contractor for non execution.
18
-
-
... More
Dismanteling the UNSV sign board in sewage wells of Sector 'A', 'B' & 'C' . Supply and fixing of retro reflector board of size 4'x3' with high quality retro reflector tape green base high intensity prismatic sheeting (HIP) grade white retro tape cutting good quality with 3mm thick ACP sheet base including 40mm x 40mm square size MS pipe legs and all around the board appx 18 feet incl welding the MS flat plate of size 25mm x 3mm across the board appx 10 feet including grouting the sign board in PCC 1:2:4 complete all as specified and directed by Engr-in-Charge.
4
-
-
... More
Supply and fixing high quality ACP sheet board of size 5 feet x 3feet minimum with router cutting letter blue base of sheets and white colour acrylic letter with complete fitting of minimum 3 Nos LED lights of 20 W of 4 feet including wiring from existing DB Board complete all as specified and directed by Engr-in-Charge. Note- Detail of printing material for flex will be provided by department.
4
-
-
... More
M&L for attending any type pump/motor/LT panels/DGs/Starters complaint at Sewage pump houses and rectify the same, rates are also included for replcement of thimbles any type and any size with nut-bolts and cable jointing with tap, gland packing, greasing in pumps/valves with all connected items all as specified by the Engr-in-Charge. Note: Complaint should be rectify within 06 Hrs otherwise a penalty of 1000 Rs per day will be imposed.
90
-
-
... More
Scraping old existing paint from delivery line inside and outside the sewage well including making smooth surface and primer and applying two coat of synthetic enamel paint of pipe size 100 to 250 mm approved colour as specified and directed by Engr-in-charge.
300
-
-
... More
Dewatering sewage well and taking up rusty & chocked CI rising main 100mm dia from sewage well 10 to 12mtr deep opening up rusty & worn out nut & bolts cleaning the same with wire brush, bocky & refixing in sewage well by replacing nut, bolts & rubber gasket etc, complete all as specified and directed by Engr-in-Charge
10
-
-
... More
All as per ser item No. 68 here in before but 150/250 mm dia.
12
-
-
... More
Supply and fix replacement CI fittings Bend, tee, reducer etc for pipe 100m to 300mm dia complete all as specified and directed.
550
-
-
... More
S&F Electric Resistance Insulated Rubber Floor mat sheet of size 1mx2mx25mm thick ISI marked and equivalent colour as per direction with fixing mtrls complete all as specified and directed.
20
-
-
... More
Supply and fixing flex board of mininmum size 4 feet x 3feet including angle iron with painting complete all as specified and directed by Engr-in-charge. Note- Detail of printing material for flex will be provided by department.
20
-
-
... More
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 3.15 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level), and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of GI strip 32x6 mm and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion.
Note:- Earthing shall be tested after execution and payment shall only be admissible if result found proper.
24
-
-
... More
M&L for preperation of old decorated plastered or unplastered surfaces of walls of Sewge tanks/bldgs by complete brooming down or steel wire brushing , scrapping down smoke and applying two coat of Apex paint complete at all Sewage well installations all as specified and directed by Engr-in-Charge.
3850
-
-
... More
M & L for preperation of old decorated brick / concrete , plastered or unplastered surfaces of ceiling by brooming down with steel wire brushing, scraping down smoke soot, moulds, moss and effloroscent salts, trading oil and grasy spots etc. and applying one coat of white wash on ceiling/wall completeat all sewage well installations all as specified and directed.
650
-
-
... More
M&L for PCC ( 1:4:8 ) type D2 with 40 mm graded aggregate for foundations, filling and mass concrete complete all as specified and directed by Engr-in-Charge .
6
-
-
... More
Desiliting/cleaning of sewage well of depth 12 Mtr and 9 Mtr dia taking out sludge by sludge vacuum truck in the form of solid also and getting out and removal to as distance exceeding 250mtr but not exc 500 Mtr and burried the same in low laying area as directed by Engr-in-Charge.
Note :- (a) Dewatering of sewage well shall be included in the quoted rate of item.
(b) Contractor have to arrange all safety equipments for works in sewage well at his own cost as directed by Engr-in-Charge.
(c) Desilting of Sewage well should be done within 72 Hrs otherwise a penalty of Rs 5000/- per day will be imposed.
20
-
-
... More
Material and labour for rubber moulded machine pressed precast concrete interlocking paver block with grey cement confirming to IS -15658-2000 of 60 mm thickness , M-35 grade as in path , hard standing etc laid over and including 25 mm compacted sand cushioning , including 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate including surface excavation over area n. exc. 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil and remving excavated soil exc 50 mtr but n . exc 250 mtr, at any installation as per requirement complete all as specified and directed by Engr-in-charge.
550
-
-
... More
Complete removal of the wild grass/ vegetation from surrounding area of SEWAGE Well installations area for each sewage well and making the surface clear and plain and spraying roundup chemical on the same clean area as directed after removing and depositing the same at a distance not less than 50 mtr away from the site complete all as specified and directed. Note:- T&P machinary will be provided by the contractor. Cleaning should be done regularly as per directed by Engr in Charge. However, payment shall be made one time during contract period. otherwise penalty of Rs. 1000/ per day per well for non cleaned surrounding area.
8000
-
-
... More
Maintenance and repair to leakage/blockage of water supply MS/CI/DI pipe line of 80 mm to 250 dia size including necessary excavation required for taking out burning out lead joint or damaged rubber ring/hole from position and making the disturbed surfaces as per existing surface after replacing new spun yarn and lead joint or Tyton joint or necessary fitting required as per site properly including welding work and making the pipe line leak proof completly to the entire satisfaction of Engineer-in-Charge .
Note:- Excavation and earth work shall be included in quoted rate.
Note: Complaint should be rectify within 12 Hrs otherwise a penalty of 1500 Rs per day will be imposed.
60
-
-
... More
Note:- Amount of credit of Rs 220890.00 for retrieved materials is mentioned in Schedule of Credit attached in tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-