Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date22 Jul 2024
Closing Date13 Sep 2024
Tender Amount₹ 49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thick , M-35 grade, set, jointed and pointed in neat cement slurry in floors with grey cement & pigments complete all as specified and directed by Engineer-in-Charge

515

-

-

... More
M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed by Engineer-in-Charge

2.5

-

-

... More
M&L Chequered cement concrete tiles20cmx20cmx25mm thick, set jointed and pointed in neat cement slurry with grey cement and pigment over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-Charge

360

-

-

... More
M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in side of path / benching / coved fillets etc rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge

4.4

-

-

... More
M & L for 75mm thick PCC 1:3:6 type C-2 as in plinth protection, finished even and fair complete all as specified and directed by Engineer-in-Charge

195

-

-

... More
M&L for providing precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in window or door cills, lintels, posts, boundary pillars, frames etc and similar works, of any section as directed, with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM 1:4 complete with joints to match complete all as specified and directed by Engineer-in-Charge

0.5

-

-

... More
M&L for providing precast cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) louvers and jallies, 40mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4 complete all as specified and directed by Engineer-in-Charge Note : Pre cast frame shall be measured and paid separately

100

-

-

... More
Demolition of brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge

24.2

-

-

... More
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
All as per item No 12 above but except bricks.

5

-

-

... More
Taking down of cement or cement lime plaster/tile work any description from brick or stone wall etc. including raking out of joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge

610

-

-

... More
M&L for Rendering,15 mm thick, in cement mortar 1:4 over brick or concrete surfaces, finished fair and even without using extra cement, mixed with water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge Note:-Integral water proofing compound shall be measured and paid separately

770

-

-

... More
Supply only integral water proofing compound conforming to IS-2645-1975 complete all as specified and directed by Engineer-in-Charge

157

-

-

... More
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls complete all as specified and directed by Engineer-in-Charge

770

-

-

... More
M&L for Painting to new or previously untreated steel surfaces of any description over 10 cm in width or girth with two coats of synthetic enamel paint over a coat of Zinc chrome primer including preparation of surfaces complete all as specified and directed by Engineer-in-Charge

160

-

-

... More
M&L for complete removal of existing treatment of walls including preparing old plaster surfaces filling of holes with plaster of paris and applying two coat of oil bound distemper over applying a coat of wall care putty on walls 1mm thick complete all as specified and directed by Engineer-in-Charge

500

-

-

... More
M&L for two coat of cement base paint on old decorated plastered surface of wall including complete removal of existing treatment & preparation of surfaces complete all as specified and directed by Engineer-in-Charge

600

-

-

... More
M&L for complete removal of existing treatment of walls including preparing old plaster surfaces filling of holes with plaster of paris and applying two coat of wheather coat/ exterior emulsion paint of electric blue or AF blue colour or equivalent colour as approved by GE, using ultra clean paint over the old decorated wall surfaces , edges of slab, roof/chajja projection and column etc, after necessary preparation with all vaccume based sanding machine complete all as specified and directed by Engineer-in-Charge

450

-

-

... More
M&L for Preparation of new steel/iron surfaces of any description applying two coates of synthetic enamel ordinary tint over a coat of red oxide primer of any description n exc 10 cm width or girth, not otherwise described complete all as specified and directed by Engineer-in-Charge

1487

-

-

... More
Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works complete all as specified and directed by Engineer-in-Charge

1.35

-

-

... More
M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopie, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge

1.35

-

-

... More
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (Horizontal or sloping) for fair finished flat surfaces of concrete complete all as specified and directed by Engineer-in-Charge

15

-

-

... More
Formwork to edges of concrete flats, roofs, floors etc not exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for fair finished surfaces complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
S&F TMT MS bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge

140

-

-

... More
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, door chowkats of angle or other section and similar works of Gde Fe-290 Gde E-165 including welding etc complete all as specified and directed by Engineer-in-Charge

280

-

-

... More
S&F mild steel work such as in angle iron, flat iron fillets etc for horn, fixing of barbed wire to RCC post, securing wire mesh etc. including all necessary cuttings, drilling, bolting or riveting etc and including 10mm MS bars as in tie bars fixed to fencing posts including necessary welding where required, as per site requirement and other similar works complete, conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge

2347

-

-

... More
S&F galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified and directed by Engineer-in-Charge Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.

15

-

-

... More
M&L for Restraining resecuring including making good staples etc galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins etc complete all as specified and directed by Engineer-in-Charge Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.

1

-

-

... More
Excavation in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50m complete all as specified and directed by Engineer-in-Charge

134

-

-

... More
Material and labour for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in fdn filling and mass concrete and filling of footing for fencing post complete all as specified and directed by Engineer-in-Charge

22

-

-

... More
M&L round bars Fe 410W of 10 mm dia and above cut to length, bent to shape required, cindluding cranking, bending spirally for hooping and fixing as required complete all as specified and directed by Engineer-in-Charge

744

-

-

... More
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n. exc 10cm long and dia 5 to 10 mm complete all as specified and directed by Engineer-in-Charge

47

-

-

... More
Supply only chain link MS galvanised fencing, of any size and type complete all as specified and directed by Engineer-in-Charge

1737

-

-

... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc including provision of binding wire.( Supply of chain link shall be measured under serial item No 37 here-in-above complete all as specified and directed by Engineer-in-Charge

724

-

-

... More
Removing excavated material to a distance n exc 50 m and depositing where directed at level n exc 1.5cm above the starting point complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
Dismantling fencing wire mesh,any type complete all as specified and directed by Engineer-in-Charge

724

-

-

... More
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed by Engineer-in-Charge

2.5

-

-

... More
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-Charge

65

-

-

... More
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed by Engineer-in-Charge

5

-

-

... More
M&L for Rendering, 15 mm thick, in cement mortar 1:6, over brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge

150

-

-

... More
M & L 10mm thick rendering in ceilings in CM(1:3) finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
M&L for preparing New plastered surfaces and applying two coats of distemper oil emulsion on wall surfaces including chalk whitening preparatory to distempering complete all as specified and directed by Engineer-in-Charge

150

-

-

... More
M & L preparation of new plastered surfaces on ceilings and applying three coats ofwhite wash complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
M&L for welding repair works at small patches like hinges, door closer, window repair, steel door/gate fittings like hinge, bolts, bars etc complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
M&L for PVC (SWR) pipes, 75 mm bore, single socketed, in any length, with rubber ring joints, fixed to wall complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
M&L for PVC (SWR) pipes, 100/110 mm bore, single socketed, in any length, with rubber ring joints, fixed to wall complete all as specified and directed by Engineer-in-Charge

25

-

-

... More
M&L for mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete all as specified and directed by Engineer-in-Charge

250

-

-

... More
M&L for Welding in repairs n. exc 2.5cm in length and thickness of metal to be welded exc 6mm but not exceeding 9mm complete all as specified and directed by Engineer-in-Charge

50

-

-

... More
S&F MS Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates, hook and pintle hinges: large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engineer-in-Charge

25

-

-

... More
M&L for repairs to steel gate/Wicket gate of sliding door bolt, hinges, pintel, locking arrangment, spike, V groove/Flat edge heavy duty gate roller, roller rails etc including greasing, welding /reveting to bring the steel gate /wicket gate in service condtions etc complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A complete all as specified and directed by Engineer-in-Charge

280

-

-

... More
S&F mild steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St-240 complete all as specified and directed by Engineer-in-Charge

200

-

-

... More
S & F Pre-painted galvalume aluminum zinc coating GI vased corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge

65

-

-

... More
S & F Pre-painted galvalume aluminum zinc coating GI vased Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge

15

-

-

... More
M&L for preparation of old steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying one coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge

50

-

-

... More
Dismantling Iron/RCC fencing posts or struts any section embedded in natural ground including taking out embedded portion and making good disturbed ground after embedding new posts complete all as specified and directed by Engineer-in-Charge

156

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing) and disposal of debris complete all as specified and directed by Engineer-in-Charge

65

-

-

... More
M&L for Providing plain cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregates, 25mm thick, as in floor/sub base and finishing concrete surface fair and even to receive top floor finishes complete all as specified and directed by Engineer-in-Charge

35

-

-

... More
M&L for Providing screed bed or bedding layer, 15 mm thick, in cement mortar 1:6 for laying floor finishes complete all as specified and directed by Engineer-in-Charge

35

-

-

... More
M&L for Rendering, 10 mm thick, in cement mortar 1:4, on wall surafaces, as backing coat to tiles complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
M&L for coloured Non Skid Ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge

35

-

-

... More
M&L for Glazed ceramic tiles, 300/350 x 450 x 7mm thick, glossy finish, first quality, of approved colour, laid on vertical surfaces such as skirting or dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge

30

-

-

... More
Excavation in trenches in soft / loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engineer-in-Charge

46

-

-

... More
Returning, filling, including spreeding leveling watering and well ramming in layers not exceeding 25 cm apart complete all as specified and directed by Engineer-in-Charge

23

-

-

... More
Removing of surplus excavated soil to distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge

24

-

-

... More
Material and labor for sand cushioning to XLPE cable with using clean dry and natural river sand with a layer of 8 cm thick before laying the cable and 15 cm thick layer after laying the cable and this then gently punned down to a thick of 10 cm above the top the upper most cable complete all as specified and directed by Engineer-in-Charge

7.2

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer-in-Charge

1280

-

-

... More
Supply,Laying,Connecting and testing in repairs cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 Volt grade cross sectional area 35 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge

200

-

-

... More
Taking down carefully aluminum/copper point wiring (light, fan, switch, socket, power point, holder) complete includind fittings and fixtures and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified keeping aside serviceable items for reuse with in the same bldg and removing U/S items from site complete all as specified and directed by Engineer-in-Charge (Refixing of serviceable fitting shall be measured and paid seperately).

104

-

-

... More
Taking down carefully copper / aluminum two core sub main wiring of sizes 4/6 Sqmm cable any type and removing old material from site and making good disurbed surface complete all as specified and directed by Engineer-in-Charge

200

-

-

... More
M&L for two single core PVC insulated cable with copper conductor multi stranded 4 Sqmm duly drawn through and including concealed PVC conduit of suitable size not less than 20mm dia as sub main with continuous earth wire 4 Sqmm size and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge(Flexible Copper Wire Used in FRLS)

200

-

-

... More
M&L for point wiring complete with 1.5 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable 1100 volts grade FRLS cable IS-694 marked drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of 2 mm thick pressed steel terminal box of suitable size with 3 mm thick laminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed by Engineer-in-Charge for following (Color coding to be followed)

72

-

-

... More
All as per item No 76 above but one three pin 5 Amps socket out let on the same board

12

-

-

... More
All as per item No 76 above but one three pin 5 Amps socket out let on independant board

10

-

-

... More
All as per item No 76 above but 15 Amps 3 pin socket outlet on independent board with 2.5 sq mm PVC insulated and sheathed copper conductor with 2.5 sq mm PVC insulated copper conductor single core for continuous earthing

10

-

-

... More
S&F Piano switch flush button,single pole,one way 5/6 Amp complete all as specified and directed by Engineer-in-Charge

94

-

-

... More
S&F piano switch flush button single pole one way 15/16 Amp complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
S&F socket outlet, in repairs,flush type 2 in 1, 2 pin and 3 pin 5 Amp complete all as specified and directed by Engineer-in-Charge

22

-

-

... More
S&F socket outlet, in repairs,flush type 2 in 1, 3 pin and 6/16 Amp complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
S&F stepped type electronic fan regulator, in repairs, flush type on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
S&F in repairs,ceiling rose surface backlight, 65 x 50 mm two to to three terminals complete all as specified and directed by Engineer-in-Charge

104

-

-

... More
S & F Modular stepped type electronic fan regulator 2 Module, on the existing phenolic laminated sheet etc complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
S&F in repairs,LED tube light batten,9/10W(+) 2% LED 6000K (2 ft.), 230 volts AC,Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver connector block,lamp etc complete with all accessories, internally pre-wired including twin core twisted flexible copper conductor of suitable size with PF -0.95,THD-10%,driver should be of same make as LED fitting,with in build over voltage ,under voltage and short circuit protection with operating range of 140 volst to 280 volts,isolation LED driver complete all as specified and directed by Engineer-in-Charge

40

-

-

... More
Supply and fix flushed inside the wall MS sunken box more than 1mm thicknes of size 8"x10" complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
S&F in repairs,sheet metal enclosure for MCB DB's SPN 240 volts, 4 way with neutral bus bar 200 Amp rated double door type regal grey complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
S&F in repairs MCB SP 6 to 32 Amps 240 Volts."B" grade complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
S&F in repairs MCB SPN, 40 Amps, 240Volts ."B" grade complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
Supply and fixing in replacement of LED building security light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge

12

-

-

... More
M&L for earthing complete for pole with galvanized mild steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtr below ground level connected by using galvanised iron strip 25 X 4mm as earthing lead size by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber) 1:2:4 type B-1 using 20mm graded stone aggregate copy shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate, internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 funnel wiht wire gauge of 22 gauge (0.68mm) 8 mesh per liner inch, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm four MS bars @ 80mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 40mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, all excavation and earth work & connectiing the earthing to an earthing test point as specified and testing on complete all as specified and directed by Engineer-in-Charge

10

-

-

... More
Supply and fix aluminium strip 25 mm x 3 mm complete with saddles and fixing screws etc for roof conductors and down conductors above ground level including removing u/s strips complete all as specified and directed by Engineer-in-Charge

350

-

-

... More
Supply and fix single pointed air termination aluminium rod,12 mm dia, 300 mm long complete all as specified and directed by Engineer-in-Charge

100

-

-

... More
S&F porcelain strip holder on wall and roof of suitable size including removing broken u/s one complete all as specified and directed.

150

-

-

... More
M&L 32 mm GI pipe light grade of 1.3 mtr long fixing in PCC cubical and complete connection of existing air termination rod complete all as specified and directed by Engineer-in-Charge

100

-

-

... More
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping and necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply and fixing in repairs lightening arrester expulsion type complete with all fittings transmission class discharge capacity up to10 kilo ampere HT 11KV 10 kilo ampere, HT 11KV, 65KA station class and shall comply with the requirements of routine test as a specified in the relevant IEC: 99-4 and IS- 3070 (Part-III) complete all as specified and directed by Engineer-in-Charge

12

-

-

... More
M & L for Cement concrete in foundations, filling and mass concrete type B2 1:2:4 (40 mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge

22

-

-

... More
M&L for broken bricks hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed by Engineer-in-Charge. Note: Item No 100 to 101 are considered for DG sets platform as per site requirement.

2

-

-

... More
M & L for taking out and shifting of existing DG Set of capacity 62.5KVA/100KVA of any make with connected panel with the help of labour and hydra installed inside/outside substation building room including removal of electric disconnection of all LT cables from DG Set/LT panels including complete welding work, all cable disconnecting items/ T&P items must be included in rate complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M & L for re-fixing / Re - Installing of DG Set at another place not exceeding 500m from original place (taking out vide item No 103) after servicing including cleaning properly of all parts ,removing dust, carbon deposits etc of connections, making all connections and re-installation with existing LT panel to same location or any other location after painting of LT panel including removing old dust partical,oily portion by rubbing with sand paper with spry pump, and writing /digital printing, Capacity Descripton, date of installation,etc with complete electrical connection with existing cable complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
M&L for attending of any breakdown of standby power supply in any location, whenever required round the clock, rectify the fault and restore the standby supply within three hours after receipt of complaint of any nature ie engine, alternator, control panel/AMF pael etc complete all as specified and directed by Engineer-in-Charge. Note- (i) The cost of replaced spare parts will be paid and measure seperatly. (ii) If complaint is not attended by contractor with in five hours the penalty of Rs 500/- per hour to be imposed and amount of penalty will be deducted from RAR. (iii) The cost of transportation (to and from) for all kind of necessary equipment /T&P shall be arranged/brought by contractor to complete the job at site or at E/M Yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically so contractor to specify the telephone/mobile No who will receive the complaint round the clock.

6

-

-

... More
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of 200 KVA capacity three phase 415 Volts, 50 HZ AC including internal wiring with suitable copper conductor with thimbles, timer, relay, MCB 6 Nos- 10 Amps, VMR 3 pole - 02 Nos, battery charger 12 V - 01 No, Motorised changeover switch CX3 200 Amps, Volt meter/Ammeter, RYB phase indicators(DG and Mains) and selector switchs etc including fixing with PCC work in floor alongwith suitable angle iron frame for AMF panel complete with all standard features, safeties etc., complete as directed and specified by Engineer in Charge.

1

-

-

... More
M&L spray gun painting of generator upto 62.5 KVA in existing colour with smooth finishing complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
M&L spray gun painting of generator 82.5 KVA upto 160 KVA in existing colour with smooth finishing complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
M&L for General Servicing of DG sets upto 160 KVA/200KVA , at run of 500 hours or 5 months which ever comes first (twice in Contract period based on condition ) comprising of Cleaning & greasing of the parts, Tappet setting as per standard, Fan belt, tensioner pulley and lever adjustments, Tightening of all the nuts, bolts and clamps, Testing & checking of AC & DC Wiring, Self & Charging Alternator cleaning and testing, checking of working & minor fault removal, Checking of Supply & return fuel pipes from fuel tank to engine. Checking of FIP timing by Fuel cut off method including Transportation, Labour charges & minor material required for servicing etc. as reqd complete all as specified and directed by Engineer-in-Charge Note - Servicing through OEM authorised rep or service engineer from the manufacturer only. (a) Cleaning of lubrication of oil filter (b) Cleaning of by pass filter (c) Cleaning of hydraulic governer (d) Cleaning of Checking and toping up of coolant (e) Cleaning of fuel filter (f) Cleaning of air cleaner element (g) Cleaning of in Air filter (h) Cleaning of radiator complete set (j) Engine oil as per manufacturer specification and any other checking as per manufacturer instruction Note: Cost of unserviceable items will be measured and paid seperately under relevant items.

4

-

-

... More
All as per item No 109 above but capacity of DG set 100 KVA

2

-

-

... More
All as per item No 109 above but capacity of DG set 82.5 KVA

1

-

-

... More
All as per item No 109 above but capacity of DG set 62.5 KVA

2

-

-

... More
All as per item No 109 above but capacity of DG set 25 to 40 KVA

2

-

-

... More
Supply only the following items of DG Set of various capacity complete all as specified and directed by Engineer-in-Charge :-

-

-

-

... More
Battery terminal, lug, bolts type suitable for heavy duty battery 12/24 V.

8

-

-

... More
Battery leads copper conductor multi wired 35 Sqmm.

6

-

-

... More
Hinges for DG set door of any size, any type as required on site.

5

-

-

... More
Servo cool plus Radiator coolent

150

-

-

... More
Low viscosity synthetic Engine oil 15W40

100

-

-

... More
M&L for Dismantling the radiator and fan from the engine for cleaning of copper tubes and cooling fins by descaling solution and using air compressor ,soldering on leakage, patch work and re-assembling the radiator and fitted with DG set properly including replacement of radiator hose pipe with clamps and bolt/nut with washer, leak check and pressure testing including transporting to repair workshop and bringing back for upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
All as per item No 120 above but capacity from 82.5 KVA upto 200 KVA

6

-

-

... More
Supply, replacment and testing of radiator assembly of DG Set 62.5 KVA complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply, replacment and testing of radiator assembly of DG Set 82.5 KVA complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply and replacement of low lube oil pressure sensor upto 160 KVA DG Set complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supply and fixing in repair of Water Pump of Radiator suitable for DG set Radiator up to 62.5 KVA complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
All as per item No 125 above but capacity from 82.5 KVA upto 200 KVA

6

-

-

... More
M&L for Removal & replacement of fly wheel gear ring suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
All as per item No 127 above but capacity from 82.5 KVA upto 200 KVA

3

-

-

... More
M&L for Removal & replacement of thermostat suitable for upto 62.5 KVA DG set connection & testing complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
All as per item No 129 above but capacity from 82.5 KVA upto 200 KVA

1

-

-

... More
Supply and fixing in repair of AVR for DG set having capacity 62.5 KVA complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
All as per item No 131 above but capacity from 82.5 KVA upto 200 KVA

4

-

-

... More
Supply and fixing in all type of hose pipe with clamps , over flow pipe, copper tube fuel supply pipe, etc with clip and complete fittings suitable for DG set upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
All as per item No 133 above but capacity from 82.5 KVA upto 200 KVA

2

-

-

... More
S&F of under/over voltage relay 3 phase 415V for DG set of capacity upto 100 KVA complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supply & Fixing in repair of Battary Charger 12V DC, 5 Amp of Autocut Electrical Battery Charger Unit SMPS with Constant Voltage Output with Battery Charging Transformer and Moulded Rectifier Unit etc suitable for smoothing functioning of DG set as required on site complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
All as per item No 136 above but capacity Battary Charger 24V DC, 10 Amp

2

-

-

... More
Supply only distilled water for top up in Batteries complete all as specified and directed by Engineer-in-Charge

100

-

-

... More
Supply only electrolyte battery solution (Dilute sulphuric acid have specific gravity 1210 degree) in 10 litrs sealed gallon packing complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
Supply & Fixing in DC 12V Stop Solenoid Coil suitable for DG Set complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply & Fixing in DC 24V Self Solenoid Coil suitable for DG Set complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
Supply and replacement of Bty 12 Volt 100 AH suitable DG set complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply and replacement of Bty 12 Volt 180 AH suitable DG set complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
M&L for repairing of self starter of DG set capacity 12 Volts including transporting upto workshop to carry out necessary replacement of burnt copper winding with new copper winding/ coil of existing gauge from rotor and stator coil, cleaning of slots, dryings varnishing and proper insulating to winding complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
All as per item No 144 above but capacity 24 Volts

1

-

-

... More
S & F Copper Battery leds suitable for Bty 12V complete all as specified and directed by Engineer-in-Charge

6

-

-

... More
Supply, fixing and testing for smoothing fuctioning Fan Belt suitable for DG set up to 62.5 KVA complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
All as per item No 147 above but capacity from 82.5 KVA upto 200 KVA

4

-

-

... More
M&L for carrying out complete over hauling/servicing of DG set panel /AMF panel/control panel including checking and rewiring of faulty electrical circuit using 1.5 Sqmm FRLS copper conductor for DG set of any type/make /capacity and making all electric connection and testing for smooth operation complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
Supply and fixing in repair IOPS Module digital display controller unit suitable for exisitng DG Set complete all as specified and directed by Engineer-in-Charge

3

-

-

... More
S&F in replacement of old u/s for fuel hose pipe from fuel filter to fuel pump for DG set upto 62.5 KVA complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
S&F in replacement of old u/s for fuel pipe from fuel tank to fuel filter for DG Set 82.5 KVA to 200 KVA complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
Supply, fixing and testing in replacement of old u/s of charging alternator 12 V/24V complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Supply and fixing in replacement of old u/s mounting rubber bushing set of 6 for existing generator complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
S&F in replacement of old u/s MNX 95, 3 pole contractor,2 NO+ 2 NC,415 volts AC, confirms to IS/IEC 60947 -4-1, in existing model and make including after taking out old unserviceable one complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
S&F in replacement of old u/s Contactor, (4 Pole AC & DC Control) operational current AC1,160 Amps,poles composition- 4NO,DC control ref-LP1D80004 of TC complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
S&F in replacement of old u/s Contactor, (4 Pole AC & DC Control) operational current AC1,125 Amps,poles composition- 4NO,DC control ref-LC1DT125A of TC complete all as specified and directed by Engineer-in-Charge

2

-

-

... More
Material and Labour for in replacement of old u/s fixing white boards 5' x 4' as per site details of Line digram / Machine History /Distribution boards complete all as specified and directed by Engineer-in-Charge

4

-

-

... More
S&F in replacement of old u/s Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engineer-in-Charge

20

-

-

... More
Taking down street light fitting or flood light fitting any type and rating from poles, walls or any other indicated situation/location after disconnecting electrically. seggregating serviceable and unservicable fittings. Keeping aside serviceable for reuse , refix after repair at same location or any other and removing unserviceable from site complete all as specified and directed by Engineer-in-Charge

24

-

-

... More
Supply and fix bracket for street light fitting made out of 40 mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts &washer and painting of clamps and street light firtting bracket with one coat of red oxide primer, one under coat and one finishiung coat with alumminium paint complete all as specified and directed by Engineer-in-Charge

24

-

-

... More
Supply and fix as in repair of 60W LED Street Light luminaire. LED Street Light shall be made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life. The luminaire shall be complete IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Street light should be top maintainable for easy maintenance.LED Street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Street Light shall be of Integral type. The Input voltage range shall be 150V to 270V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Street Light shall have power factor more than 0.95 complete all as specified and directed by Engineer-in-Charge

24

-

-

... More
Supply and fix in replacement of old unserviceable aluminium conductor cable single core PVC insulated and sheathed aluminium conductor cable of size 1.5 sqmm down through the existing pole/GI pipe bracket complete all as specified and directed by Engineer-in-Charge

100

-

-

... More
Supply and fix as in reapir / replacement of pole mounted street light factory fabricated junction box of size 260 x 120 x 230 mm of approved make and of appropriate size made out of 2 mm thick CRCA powder coated sheet , including 63A Single Phase two wire having two no.AL Bus Bar including 6A SP MCB. The box should have auto Door Lock facility with magnetic Lock having Size box fixed on pole using necerssary fixing arrangement such as clamps,nut,bolts and washer including taking down existing junction box of any description/type etc complete all as specified and directed by Engineer-in-Charge

16

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.