Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689249_1Tender No
GE/CHM-97/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item 2 here-in-before but for 4 Ton cassette type / ductable type AC. Make: Amtrex LG/ Danfoss/ Indofos/ Copeland
8
-
-
... More
All as per item 2 here-in-before but for 3 TR cassette type / Pillar type AC. Make: LG/Hitachi
32
-
-
... More
Material for providing insulation on and around suction and discharge copper tube of size 1/2'' and 1/4'', 3/8" and 5/8" with 6 mm thick flexible thermocol heat resistance duly warpped with sticking tape and finally covered with flexible PVC conduit of 50mm dia complete all as specified and as directed.
150
-
-
... More
Supply only of AC 4 Pole power contactor three phase of capacity 25 Amp to 40 Amp suitable for pillar type AC-3 TR/5TR/8.5R complete all as specified and as directed.
40
-
-
... More
Supply only liquid line drier filter suitable for 8.5 ton ductale AC with necessary brazing work and charging the refrigerant after replacing the liquid line filter to obtain adequate cooling complete all as specified and as directed. Note:- Supply and charging Refrigerent gas will be measured and paid seperately under relavent items. Make of drier filter: LG / Danfoss / Hitech
10
-
-
... More
All as per item 8 here-in-before but for 3 to 5 TR ductable type AC. Make: Amtrex/ Danfoss/ Indofos
10
-
-
... More
Supply only of air filter set suitable for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
20
-
-
... More
All as per item 10 here-in-before but for 3 to 5 TR ductable / cassette type AC. Make: Amtrex/ Danfoss/ Indofos
20
-
-
... More
Supply only of low / high pressure switch for 8.5 ton ductable split type AC complete all as specified and as directed. Make : LG / Danfoss / Hitech
20
-
-
... More
All as per item 12 here-in-before but for 5 TR/3 TR ductable / cassette type AC. Make: Amtrex/ Danfoss/ Indofos
10
-
-
... More
Taking out unserviceable sealed unit compressor from cassetee/ pillar type air conditioner by disconnecting cooling and condensor copper pipe and electric connection carefully and Supply and fixing new scroll compressor of capacity 3 ton including charging of refrigerant gas R-22 upto required cooling and connecting all the copper pipes, electric connection and testing the AC complete all as specified and as directed. Make : LG/ Danfoss/ Sanyo/ Tecumseh/Kirloskar/ Comipro/Copeland
NOTE : Supply and charging refrigerent gas will be measured and paid separately under relavent items
15
-
-
... More
All as per item 14 here-in-before but three phase compressor of capacity or 4TR/4.25 TR suitable for 8.5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland
25
-
-
... More
All as per item 14 here-in-before but three phase compressor of capacity 5 TR suitalbe for 5 TR ductable AC. Make : LG / Kirloskar / Tecumseh/Danfoss/Comipro/Copeland Note for serial item No 14 to 16 : Supply and charging refrigerent gas will be measured and paid seperately under relavent items
4
-
-
... More
Carrying out pressure leak test of 3 to 8.5 ton ductable split type AC whenever required by nitrogen gas pressure for detecting leakage in cooling/condensing unit refrigerant pipe and repairing the leakage by welding or brazing of condensing/ cooling unit, refrigerant pipe and putting under pressure for leakage checking after repair of leaking pipe flushing out by N2 and CTC/ vaccumination complete all as specified and as directed. Note :-Supply & charging of refrigerant gas R-22 will be measured and paid for separately
30
-
-
... More
Supply only thermal relay 15 A to 30 Amps, 415 Volt, single phase suitable for pillar/ cassette/ductable type AC of 3 TR/5 TR/8.5 TR capacity as per sample complete all as specified and as directed. Make : LG / Hitech/Indo Asian/L&T/Tecumseh.
20
-
-
... More
Supply only PCB (circuit plate) of out-door/indoor unit of 8.5 TR ductable split AC complete all as specified and as directed.
10
-
-
... More
All as per item 19 here-in-before but for pillar /ductable/ casette / any type AC 3.0 TR to 5.0 TR
10
-
-
... More
Repair only PCB (circuit plate) of outdoor /indoor unit of 8.5 TR ductable split AC complete all as specified and as directed.
10
-
-
... More
All as per item 21 here-in-before but for pillar /ductable/ casette / any type AC 3.0 TR to 5.0 TR.
10
-
-
... More
Supply only single phase preventor, 230 volt, 50 HZ, AC supply suitable for 3 to 8.5 TR AC as per sample complete all as specified and as directed. Make : L&T / Seimens / Hagger.
50
-
-
... More
Supply only reverse cycle valve suitable for cassette/pillar type AC of capacity AC 3.0 Ton to 8.5 Ton as per sample complete all as specified and as directed.
20
-
-
... More
Supply only indoor fan / blower motor for cooling coil/ condensing coil 1/3 HP, 230 volt, 930 RPM including blower suitable for ductable AC 3 TR to 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
15
-
-
... More
Supply only outdoor fan / blower motor for cooling coil/ condensing coil 1/3 HP, 230 volt, 930 RPM including blower suitable for ductable AC 3 TR to 8.5 TR complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar.
15
-
-
... More
Supply only drain pump DC 12/24 volt or AC 230 for indoor unit, cassette type AC of 3 TR to 4 TR as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan.
10
-
-
... More
Supply only drain pipe of PVC medium grade of 25mm with all accessories like elbow, socket, tees, bend, adhesive etc complete all as specified and as directed.
100
-
-
... More
Supply only drain pipe of PVC flexible 15mm with all accessories like elbow, socket, tees, bend, adhesive etc complete all as specified and as directed.
200
-
-
... More
Supply only complete wiring kit for indoor / outdoor panel of ductable AC of capacity 3 to 8.5 Ton complete all as specified and as directed.
20
-
-
... More
Supply only starter 3 phase ,415V, 40A suitable for ductable AC of cap3 to 8.5 TR complete all as specified and as directed. Make: L&T/BCH/ABB
10
-
-
... More
Disconnecting electric connection from defective blower/ fan motor and taking out from unit capacity 3 to 8.5 TR of existing make and transporting to store yard of Refg AC Section, then to be transported to contractors workshop after getting the gate pass from Engineer-in-Charge. Dismantling the burnt winding & rewinding of 1/6 to 1/8 HP double shaft blower motor with the existing size of super enemelled copper winding as per existing gauge wire as per maunufactrer instructions including insulation, varnishing, greasing, testing complete and transporting back to the location from where it was disconnected and refixing the same and testing complete all as specified and as directed.
4
-
-
... More
Supply only AC contactor single phase 230 volt, 50 Hz, double pole, AC3 rating 25 Amp to 40 Amp, AC1 rating 45 Amps to 55 Amps complete all as specified and as directed.
50
-
-
... More
Taking down of defective evaporator unit of 3 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or as per existing make with evaporator coil blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
2
-
-
... More
Renewal condensing unit of Cassette type AC of capacity 3 TR capacity outdoor unit complete with condensing coil, compressor, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerant gas will be measured and paid for separetly.
2
-
-
... More
Taking down of defective evaporator unit of 4 TR capacity Cassette type AC and supply & fixing new evaporator unit of the same capacity (Make: Toshiba/ LG/ Totaline or as per existing make with evaporator coil blower motor, front grill and connecting the cooper tubing by brazing, detecting leakage, rectifying the same and recharging with refrigerant gas as required to obtain adequate cooling complete all as specified and as directed. Note: Supply & charging of refrigerant gas will be measured and paid for separately
1
-
-
... More
Renewal condensing unit of Cassette type AC of capacity 4 TR capacity outdoor unit complete with condensing coil, compressor, wiring kit, starting and running capacitor, relay, condensing/ outdoor motor with blade complete all as specified and as directed Make: Toshiba/ LG/ Voltas or equivlent) Note : Supply and charging of refrigerant gas will be measured and paid for separetly.
1
-
-
... More
Vertical three phase distribution board 12 way 440 volts having IP 43 protection with metal double door with provision for fixing of MCCB's as incomer and outgoing MCB TPN complete all as specified and directed and making new electrical connections with thimbles or other suitable arrangements including taking down existing unserviceable DB and making good surface with matching existing surfaces all as specified and directed.
1
-
-
... More
MCB Triple pole & Neutral C curve 63 Amp 10 KA including taking down existing unserviceable MCB complete all as specified and directed
30
-
-
... More
Renewal MCCB, four pole, 300 Amp 415 volts. 50 Hz breaking capacity not less than 36 kA with adjustable thermal and adjustable magnetic protection release with spreader links. Ics = 100% lcu complete all as specified and as directed.
2
-
-
... More
Renewal MCCB, four pole, 160 Amp 415 volts. 50 Hz breaking capacity not less than 36 kA with adjustable thermal and adjustable magnetic protection release with spreader links. Ics = 100% lcu complete all as specified and as directed.
2
-
-
... More
5/8” and 3/8” dia copper pipe including tubular heat/cold resistant rubber pipe insulation complete all as specified and as directed.
Note : 1 meter of 5/8" dia copper pipe, 1 meter of 3/8" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
100
-
-
... More
All as per item 42 here-in- before but size 1/2” and 1/4” dia,
Note : 1 meter of 1/2" copper pipe, 1 meter of 1/4" dia copper pipe & 01 meter insulation shall be considered as 1 RM for payment purpose.
100
-
-
... More
flair nut of 5/8" and 3/8" dia complete all as specified and as directed.
50
-
-
... More
flair nut of 1/2" and 1/4" dia complete all as specified and as directed.
50
-
-
... More
4 core copper wire size 6 sqmm PVC insulated 1100 volt grade complete all as specified and as directed.
200
-
-
... More
3 core copper wire size 4 sqmm PVC insulated 1100 volt grade complete all as specified and as directed.
200
-
-
... More
Supply & charging (Topping up) the ductable/ cassette type AC etc with refrigerant gas R-22 in required quantity for desired cooling complete all as specified and as directed.
Note:-The contractor should weight on balance of empty/refill cylinder of the refrigerent and refrigerent before/after using in MES store Yard.Electric balance should be provided by the contractor complete all as specified and as directed.
350
-
-
... More
Suction valve/ discharge valve suitable for 4.25, 3 & 5 TR compressor all as specified and as directed.Make:- BAP / TAK Cassel
30
-
-
... More
Supply only remote control hand set for existing window type/ split type air conditioner of make LG/ Samsung/ Voltas/ Bluestar or as per existing and of cap 3 to 8.5 ton with required pencil cells complete all as specified and as directed.
20
-
-
... More
Supply only any type of sensor suitable for AC of 3 TR to 8.5 TR as per sample complete all as specified and as directed. Make : LG / Tecumseh / Kirloskar/daccan.
50
-
-
... More
Dismantling at site for Repair and replace the defective parts to automatic phase corrector panel and reinstalled including S&F Contactor 415 v 300Amps cat pt no. MCE15SN3M7 and testing complete including making electric connection and all as specified and directed by Engr-in Charge.Make BCH or Equivalant
4
-
-
... More
Coil 415 v 300 Amps cat part No.2-2412-M complete all as specified and directed.
4
-
-
... More
Reley minilac 415 V cat part No.VSPD1415V complete all as specified and directed.
4
-
-
... More
Magnetic connector 415 V, 25 amps to 63 amps suitable for AC 3 to 8.5 TR and all as specified and directed by Engr-in Charge
20
-
-
... More
Condencing coil of out door unit suitable for AC 3 to 8.5 TR, fixed as in repair complete all as specified and directed.
5
-
-
... More
Evaporator coil of in door unit suitable for AC 3 to 8.5 TR, fixed as in repair complete all as specified and directed.
5
-
-
... More
Tray of thermocol suitable for drain of water of indooor unit suitable for AC 3 to 8.5 TR, complete all as specified and directed.
5
-
-
... More
Supply only 2.5 to 10 Mfd running capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
40
-
-
... More
Supply only 36 to 60 Mfd running capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
60
-
-
... More
Supply only 40/60,80/100 to 100/120 Mfd starting capacitor for cooling appliences complete all as specified and as directed.Make - Sharda / Asian / Unistar / Tesla / Epcos.
60
-
-