Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date19 Sep 2024
Closing Soon18 Oct 2024
Tender Amount₹ 38,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F steel work as in tubular roof trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 Gde St 240 all as specified and as directed.

13500

-

-

... More
S&F rolled mild steel work as in Plates (plain or chequered) channels, Square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary welding etc. conforming to Gde E-250 (Fe 410-W) quality `A’ all as specified and as directed.

1000

-

-

... More
S&F Wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc. flat iron fillets (for securing wire mesh etc.) incl all necessary drilling, bolting or riveting ect and similar work conforming to Fe-290 Gde E-65.

100

-

-

... More
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified & directed.

862

-

-

... More
M&L for hardcore of broken stone or boulders, gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface all as directed.

86

-

-

... More
M&L for 100mm thick PCC M-15 in floor and paving finished even and smooth with out using extra cement all as specified and as directed.

862

-

-

... More
M&L for factory made 80mm thick machine pressed precast cement concrete coloured interlocking paver blocks glossy finish of Grade M-40 conforming to IS 15658-2006 of shape and size as directed with grey cement and pigment laid over & including 25mm thick sand cushioning, joints of blocks filled with dry sand and compacted with mechanical vibrator complete all as specified & directed.

862

-

-

... More
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified and directed.

250

-

-

... More
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified.

60

-

-

... More
M & L for rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified.

550

-

-

... More
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved shade/tint over a coat of primer of same make all as specified & as directed.

550

-

-

... More
Material and labour for point wiring for one light point controlled by one, one way switch with multistrand 1.50 Sqmm unsheathed copper conductor PVC insulated FRLS cable including continuous earth wire 1.5 Sqmm in green colour unsheathed copper conductor PVC insulated FRLS cable connected to common earth dolly in PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS in on New wooden boards fixed on wall for mounting switch, socket, regulators etc with and and including 3 mm thick new bakelite laminated sheet top cover ‘Hylam’, complete, all as specified & directed. (Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of BoQ' ).'

40

-

-

... More
S&F ceiling rose surface bakelite 65mm x 50mm, 3 terminals with back plate etc complete all as specified and

40

-

-

... More
S&F sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated, protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200 Amp rating copper bus bar, complete all as specified & directed.

1

-

-

... More
S&F MCB SPN, 32 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.

6

-

-

... More
S&F MCB SPN, 40 to 63 Amps 240 Volts , type 'C' curve, 10 KA, IS-8828 marked fixing in DB complete all as specified & directed. Note :-Make of MCB shall be same of that DB.

1

-

-

... More
S&F in repair Sub main wiring with two single core cable PVC insulated unsheathed of copper multi stranded conductor FRLS cable of size 1.5 sqmm, 1100 votls grade drawing through and including concealed conduit 25 mm dia medium duty including acessories such as Tee, bend, Elbow etc, ISI marked with and including PVC insulated 1.5 sqmm unsheathed multistranded FRLS copper conductor cable for earth continuity and connected to common earth dolly including cutting chasing of wall, if required and making good disturbed surface in CM (1:3) and finishig the surface to match with existing surface, etc complete all as specified and directed by Engineer-in-charge including taking down old unserviceable submain wiring. Note:- (i) Three lengths of 1.5 Sqmm cable, one length of 1.5 Sqmm cable and one length of PVC conduit will be measured as one length.

100

-

-

... More
S&F in replacement LED light fitting 1x40W, 220V AC wall mounted LED batten with aluminium housing and integrated electronic driver with efficiency of 100lumen / watt connecting with three core flexible copper conductor from ceiling rose complete all as specified and directed.

32

-

-

... More
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with dirver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including 1.5 mtr 25mm GI pipe bent to shape as angle bracket fixed on building as building security light complete all as specified and directed.

8

-

-

... More
S& F XLPE insulated, armoured heavy duty electric cable with aluminum conductor, 1100 volts grade, cross-sectional area 10 sq mm 2 Core.

130

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil complete all as specified and as directed.

14

-

-

... More
Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick etc complete all as specified and as directed by Engineer-in-Charge.

7

-

-

... More
Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed.

7

-

-

... More
M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .

0.6

-

-

... More
M&L for Sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed. Note :- For the purpose of payment only punned thickness shall be measured.

6

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.