Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date7 Mar 2025
Closing Date29 Mar 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 300 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 185 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 120 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 95 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.

200

-

-

... More
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 50 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge.

300

-

-

... More
M&L as in replacement of Power Cables, Aluminium Stranded Conductor 25 sqmm, 4 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings/LT OH Line and testing on completion including taking down old unserviceable cable complete all as specified and directed by Engineer-in-Charge. Note for item 04 to 09 above: (i) Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.

300

-

-

... More
Supply and laying Double wall corrugated HDPE duct pipe of 50 mm outer dia conforming to IS:14930 Pt-II with antirodant and non flame propergating properties of make and colour as approved by Engineer-in-Charge with fittings as protection to cable, laid in tranches or fixed to poles/walls complete all as specified and as directed.

550

-

-

... More
Supply and lay Double wall corrugated HDPE duct pipe of 100 mm outer dia conforming to IS:14930 Pt-II with antirodant and non flame propergating properties of make and colour as approved by Engineer-in-Charge with fittings as protection to cable, laid in tranches or fixed to poles/walls complete all as specified and as directed.

750

-

-

... More
M&L Cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate for foundations, mass and for repairing to paths/ road & hardstanding etc. including necessary cutting of roads/ paths for passing of pipes and making good the disturbed portion complete all as specified and directed by Engineer – in - Charge.

2

-

-

... More
Supply and laying as in replacement 80 mm bore tube "light grade" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge.

6

-

-

... More
Supply and laying as in replacement 50 mm bore tube "light grade" galvanised iron pipe laid in trenches or fixed along poles with mild steel clamps or protection to GI earth strip/cable, complete all as specified and directed by Engr-in- Charge.

12

-

-

... More
M&L for Finding of fault to 1100 Volts LT UG cable with electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency , distance calculator etc including and additonal excavation in normal/ alluvial strata required for exposing the cable fault, removal of deterioted portion of cable and keeping the same ready for jointing work for cable of any size. The fault locating equipments will be brought to site within the hours of instruction form Engr-in-Charge as specified. Note - (a) Cable jointing kit and XLPE cable of required length, if any shall be measured and paid separaetly under respective items. (b) Cost of necessary T&P shall be deemed to be included in the quoted rates. (c) Report for the fault obtained shall be kept in record duly giving location and other related details and signed by rep of company and Engineer-in-charge.

50

-

-

... More
Supply and fixing in repairs only electrical panel doors fabricated from MS sheet as per existing size and shape and fixed with hinges by properly welding and checking for proper closing and opening complete all as specified and directed. Note:- Repairing and refixing of one door panel fitted with 2/3 hinges shall be considered as one job. Any small piece of MS sheet of thickness 2mm or 3mm required for repairing the portion of the door to be fixed with hinges and replacing any damaged MS hinge shall be deemed to be included in the unit rate quoted.

20

-

-

... More
Design, fabricate, supply, installation, testing and commissioning in replacement of outdoor type dust proof & vermin proof cubicle panel board compartmentalized with seperate bus and cable alley chambers suitable for 3 phase, 4 wire, 415 Volts, 50 Hz, AC supply system as per latest IS / IEC standards & regulations, factory fabricated in an approved factory (Manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3 mm thick for outer shell and 2 mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad-locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mmx50mmx6mm angle iron base frame of suitable size for mounting the panel board, 04 nos legs 600 mm long with a minimum ground clearance of 450 mm above GL to the bottom of panel including PCC foundation with PCC 1:2:4 type B-1 graded aggregate stone for grouting of base.

2

-

-

... More
Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards(02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1500mm x 1300mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity including taking down old unserviceable LT Panel complete all as specified and directed. Note: (i) Factory made name plates with feeder names / Bldg Nos shall be fixed on relevant incomer / outgoing MCCB doors. (ii) The Contractor shall submit set of all drawings of the L.T. Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing.

-

-

-

... More
However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations. (i) Bus bar: TPN Aluminium bus bar of rating suitable rating provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators for main bus bar and from main bus bar to outgoing MCCBs and outgoing MCCBs up to cable termination etc complete. (The rating of main bus bar shall be 1.5 times of ampere rating of incomer and outgoing bus bar rating shall be 1.5 times of ampere rating of each outgoing MCCB.) and Continuous earth bus with GI strip of suitable size capable for carrying full short circuit current for 1 sec shall be provided at bottom of the panel. (ii) Incomer: (a) MCCB, 400 A, 4 Pole, 50 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No (b) Digital Voltmeter with selector switch - 01 Set. (c) Digital Ammeter with selector switch & suitable ratio of CT's - 01 set of 03 (d) LED Pilot light indication lamps for R,Y,B phases - 01 Set of 03.

-

-

-

... More
(iii) Outgoing:- (a) MCCB, 200 A, 3 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 Nos (b) MCCB, 160 A, 3 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 04 Nos (c) MCCB, 63 A, 3 Pole, 25 KA (Ics=100%Icu), 415 V, 50 Hz, with adjustable thermal - magnetic release - 01 No (d) On-Load Changeover switch 4 Pole, 400A, 415 Volts, AC, 50 Hz in sheet Metal enclosure with front operated handle - 01 No. Make:- As specified in list of makes as given in Appx 'B' of PS for Group - I of LT Panels.

-

-

-

... More
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including galvanized iron strip 32x6mm by means of GI bolts, nuts, check nuts and washers and connected other end to main board duly protected by GI pipe 40mm bore medium grade, earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No. 3 of SSR Part – I and connecting to earthing test point, main switch board and testing on completion including CI cover, frame and PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in earthing pit with CI cover and frame including necessary earth works etc, complete all as specified and directed by Engineer - in – Charge. Note:- 1. PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner.

10

-

-

... More
Supply only LT insulation tape ( FR PVC electrical insulation tape ) 0.125 mm thick , 1.80 cm width and 25 mtr length complete all as specified and as directed.

1000

-

-

... More
M&L for repair of any type of breakdown in LT Panel / feeder fillar box of any size by carrying out necessary rectification work including disconnecting the LT cable, taking down any burnt/ unserviceable parts like MCCBs of any rating, onload changeover switch of any rating, aluminium lug eye type of any size, decarbonizing and cleaning the conducting parts of the panel with CRC power spray, replacing the unserviceable parts with new one, dressing the cable properly with LT insulation tape and restoring back the electric supply including ensuring the availabilty of electric supply in the affected area complete all as specified and as directed.

350

-

-

... More
Note :- (a) The items required for the repair shall be measured and paid separately under respective items as supply only. The cost of taking down of old unserviceable/burnt material shall be deemed to be included in the quoted rates. (b) Conveyance and necessary T&P for maintaining the services shall be provided by the contractor and unit rate quoted will be deemed to include the cost of the same. (c) Repair work shall be initiated within an hour of receipt of intimation of breakdown by JE/ Engineer-in-charge otherwise a penalty of Rs 500 per hour per event shall be levied to the contractor.

-

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 25 sqmm.

250

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 35 sqmm.

250

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 50 sqmm.

300

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 70 sqmm.

300

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 95 sqmm.

300

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 120 sqmm.

250

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 150 sqmm.

250

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 185 sqmm.

200

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 240 sqmm.

150

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 300 sqmm.

100

-

-

... More
Supply only heavy duty aluminium lugs eye type (Thimble) of size 400 sqmm.

100

-

-

... More
M&L for repair of any type of breakdown in LT electric supply due to fault in LT cables laid in ducts/poles/walls and floors of any size , by carrying out the rectification work including location of fault in LT cable, disconnecting the electric supply of the cable, cutting the affected cable and making arrangements for joining the cable ends with aluminum inline connectors complete all as specified and as directed. Note - Spares shall be measured and paid in respective items as supply only.

150

-

-

... More
Supply only heavy duty aluminium in line connector (Ferrule) of size 25 sqmm.

50

-

-

... More
Supply only heavy duty aluminium in line connector (Ferrule) of size 35 sqmm.

50

-

-

... More
Supply only heavy duty aluminium in line connector (Ferrule) of size 50 sqmm.

30

-

-

... More
Supply only heavy duty aluminium in line connector (Ferrule) of size 70 sqmm.

20

-

-

... More
Supply and fix Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE cable of size 25 to 50 Sqmm complete all as specified.

10

-

-

... More
Supply and fix Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE cable of size 70 to 120 Sqmm complete all as specified.

15

-

-

... More
Supply and fix Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE cable of size 150 to 185 Sqmm complete all as specified.

15

-

-

... More
Supply and fix Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE cable of size 240 to 300 Sqmm complete all as specified.

7

-

-

... More
Supply and fix Heat Shrink jointing kit for 1100 volts grade cable for straight through joint complete with jointing material and accessories suitable for 3.5 core XLPE cable of size 400 to 500 Sqmm complete all as specified.

3

-

-

... More
Supply and fix in replacement of MCCB 630 A ,4 pole ,50 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
Supply and fix in replacement of MCCB 500 A ,4 pole ,50 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.

1

-

-

... More
Supply and fix in replacement of MCCB 400 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.

2

-

-

... More
Supply and fix in replacement of MCCB 315/350 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.

3

-

-

... More
Supply and fix in replacement of MCCB 250 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.

4

-

-

... More
Supply and fix in replacement of MCCB 200 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.

4

-

-

... More
Supply and fix in replacement of MCCB 160 A ,4 pole ,36 KA (Ics =100% Icu) with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the Engineer-in-Charge.

4

-

-

... More
Material and labour for drawing out of LT ACB 4 pole 415 volts of capacity 630/800/1000/1200 amps form the LT panel and servicing/ repairing the same for proper functioning, tightening the loose hardware parts and loose connections and lubricating all mechanism, clean all contacts with fine emery paper and CRC, replacement of burnt/defective parts, applying petroleum jelly on the contacts, refixing in the original position and checking for proper functioning, complete all as specified and directed Note - Defective parts will be measured and paid seprately under the relevant items.

15

-

-

... More
Supply only fixed contacts as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed.

6

-

-

... More
Supply only moving contacts as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed.

6

-

-

... More
Supply only spring charging and operating mechanism as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply only shunt trip coil 240 volts as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply only CT as per sample suitable for 630/800/1000/1200 amps capacity of LT ACB of any make complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply and fixing in replacement voltmeter, digital type, 0-500 volts with inbuilt selector switch, size 96 x 96 mm, complete all as specified and directed.

5

-

-

... More
Supply and fixing in replacement ammeter meter, digital type 0-1000 amp with inbuilt selector switch, complete with suitable size of CTs, 96 x 96 mm complete all as specified and directed.

5

-

-

... More
Supply and fixing in replacement multimeter flush mounitng type, digital type,0 -500 volts and 0-750 amp, 50 Hz, 96 x 96 mm complete all as specified and directed .

5

-

-

... More
Supply and fixing in replacement APFC panel relay 8 steps, 415 volts, single CT input 1/5 Amps including taking down old unserviceable relay complete all as specified and directed.

5

-

-

... More
Supply and fixing in replacement APFC panel relay 12 steps, 415 volts, single CT input 1/5 Amps including taking down old unserviceable relay complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement APFC panel relay 14 steps, 415 volts, single CT input 1/5 Amps including taking down old unserviceable relay complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement capacitor duty contactor 5 KVAR, 440 volts, 3 phase, 50 Hz, detaching type early make contacts, separate termination for damping resistor, encapsulated damping resitor assembly, built in surge supresspr low pick up VA consumption including taking down old unserviceable complete all as specified and directed .

5

-

-

... More
Supply and fixing in replacement capacitor duty contactor 10 KVAR, 440 volts, 3 phase, 50 Hz, detaching type early make contacts, separate termination for damping resistor, encapsulated damping resitor assembly, built in surge supresspr low pick up VA consumption including taking down old unserviceable complete all as specified and directed .

5

-

-

... More
Supply and fixing in replacement capacitor duty contactor 15 KVAR, 440 volts, 3 phase, 50 Hz, detaching type early make contacts, separate termination for damping resistor, encapsulated damping resitor assembly, built in surge supresspr low pick up VA consumption including taking down old unserviceable complete all as specified and directed .

5

-

-

... More
Supply and fixing in replacement capacitor duty contactor 20 KVAR, 440 volts, 3 phase, 50 Hz, detaching type early make contacts, separate termination for damping resistor, encapsulated damping resitor assembly, built in surge supresspr low pick up VA consumption including taking down old unserviceable complete all as specified and directed .

5

-

-

... More
Supply and fixing in replacement capacitor duty contactor 25 KVAR, 440 volts, 3 phase, 50 Hz, detaching type early make contacts, separate termination for damping resistor, encapsulated damping resitor assembly, built in surge supresspr low pick up VA consumption including taking down old unserviceable complete all as specified and directed .

5

-

-

... More
Supply and fixing in replacement capacitor duty contactor 50 KVAR, 440 volts, 3 phase, 50 Hz, detaching type early make contacts, separate termination for damping resistor, encapsulated damping resitor assembly, built in surge supresspr low pick up VA consumption including taking down old unserviceable complete all as specified and directed .

3

-

-

... More
Supply and fixing in replacement of heavy duty capacitors cylindrical series 5 KVAR rating, 440 Volts including taking down old unservieable complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement of heavy duty capacitors cylindrical series 10 KVAR rating, 440 Volts including taking down old unservieable complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement of heavy duty capacitors cylindrical series 15 KVAR rating, 440 Volts including taking down old unservieable complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement of heavy duty capacitors cylindrical series 20 KVAR rating, 440 Volts including taking down old unservieable complete all as specified and as directed.

3

-

-

... More
Supply and fixing in replacement of heavy duty capacitors cylindrical series 25 KVAR rating, 440 Volts including taking down old unservieable complete all as specified and as directed.

4

-

-

... More
Supply and fixing in replacement of CR15 contactor, 22 A, 415 Volts, including taking down old unserviceable complete all as specified and as directed.

3

-

-

... More
Supply and fixing in replacement of CR15 contactor, 04 A (4 NC), 415 Volts, including taking down old unserviceable complete all as specified and as directed.

2

-

-

... More
M&L for in replacement of complete internal wiring of 50 KVAR APFC Panel parts i.e. relay, contractors, ammeter, voltmeter with HRFR 1.5 sqmm multistranded copper cable with proper coding of each circuit of capacitors/contractors/voltmeter/ammeter/indication lamp etc including taking down old unservicebale wiring complete all as specified and as directed.

1

-

-

... More
M&L for in replacement of complete internal wiring of 75 KVAR APFC Panel parts i.e. relay, contractors, ammeter, voltmeter with HRFR 1.5 sqmm multistranded copper cable with proper coding of each circuit of capacitors/contractors/voltmeter/ammeter/indication lamp etc including taking down old unservicebale wiring complete all as specified and as directed.

1

-

-

... More
M&L for in replacement of complete internal wiring of 100 KVAR APFC Panel parts i.e. relay, contractors, ammeter, voltmeter with HRFR 1.5 sqmm multistranded copper cable with proper coding of each circuit of capacitors/contractors/voltmeter/ammeter/indication lamp etc including taking down old unservicebale wiring complete all as specified and as directed.

1

-

-

... More
M&L for in replacement of complete internal wiring of 125 KVAR APFC Panel parts i.e. relay, contractors, ammeter, voltmeter with HRFR 1.5 sqmm multistranded copper cable with proper coding of each circuit of capacitors/contractors/voltmeter/ammeter/indication lamp etc including taking down old unservicebale wiring complete all as specified and as directed.

1

-

-

... More
M&L for in replacement of complete internal wiring of 150 KVAR APFC Panel parts i.e. relay, contractors, ammeter, voltmeter with HRFR 1.5 sqmm multistranded copper cable with proper coding of each circuit of capacitors/contractors/voltmeter/ammeter/indication lamp etc including taking down old unservicebale wiring complete all as specified and as directed.

1

-

-

... More
M&L for in replacement of complete internal wiring of 200 KVAR APFC Panel parts i.e. relay, contractors, ammeter, voltmeter with HRFR 1.5 sqmm multistranded copper cable with proper coding of each circuit of capacitors/contractors/voltmeter/ammeter/indication lamp etc including taking down old unservicebale wiring complete all as specified and as directed.

1

-

-

... More
M&L for in replacement of complete internal wiring of 250 KVAR APFC Panel parts i.e. relay, contractors, ammeter, voltmeter with HRFR 1.5 sqmm multistranded copper cable with proper coding of each circuit of capacitors/contractors/voltmeter/ammeter/indication lamp etc including taking down old unservicebale wiring complete all as specified and as directed.

1

-

-

... More
Supply and fixing in replacement MCB TP 32 Amps, 415 volts, 'D' curve/ series including taking down old unserviceable complete all as specified and directed.

5

-

-

... More
Supply and fixing in replacement MCB TP 40 Amps, 415 volts, 'D' curve/ series including taking down old unserviceable complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement MCB FP 63 Amps, 415 volts, 'D' curve/ series including taking down old unserviceable complete all as specified and directed.

2

-

-

... More
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth, in layers not exceeding 25cm, watering, and removing surplus spoil to a distance not exceeding 50 m and making good surface all as specified and directed by Engineer - in - Charge.

75

-

-

... More
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in hard / dense soil all as specified and directed by Engineer - in – Charge.

600

-

-

... More
M&L for Hardcore of gauge n exc. 63 mm of broken stone, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface around outdoor transformer and HT 11 KV two/four pole structure complete all as specified and directed.

60

-

-

... More
M & L Sand filling under floors or in foundations including watering and consolidation all as specified and directed by Engineer - in - Charge.

60

-

-

... More
M&L Brick work with sub class 'B' old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .

5

-

-

... More
M & L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .

5

-

-

... More
S & F mild steel work as in posts, struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, and necessary provision of notch including welding and cutting at bottom etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge.

600

-

-

... More
Supply only chain link MS galvanised fencing any size or type all as specified and directed by Engineer - in - Charge.

800

-

-

... More
Fixing only of chain link fencing including line wire, any mesh size and type to any type of standard rails straining bolts etc including provision of binding wire all as specified and directed by Engineer - in - Charge.

180

-

-

... More
M & L 10 mm mild steel round bars Fe-410-W(Gde. E-250) quality-A or Fe 290 (Gde-E-165) for securing chain link fencing including forming necessary hook/ bend for tightening with fencing post and the like complete all as specified and shown on drg.

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.