Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 50,740Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Cwe/ggn/ft-10/2024-25 Comprehensive Maintenance Of Lifts, Stp And Other Connected Allied Works Associated Works Under Aor Of Ge (af) Faridabad
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666853_1Tender No
CWE/GGN/FT-10/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(viii) The cost of labour required for replacement of spares/ accessories deemed to be included in the quoted rates.
(ix) Lift mechanic shall be equiped with well experienced in lift / elevators repair and maintenance.
(x) Contractor shall submit police verification certificates of engaged staff before commencement of works.
(xi) Contractors shall carryout daily, weekly, fortnightly, monthly quarterly, half yearly inspection and submit the same to Engineer-in-charge without fail.
(xii) Non wearing of uniform by contractor staff a penalty of Rs 500/- shall be in forced per person per shift.
(xiii) All spares shall be deemed to be included in Sch "A" Section - I & II and cost is included in quoted rate.
(xiv) The contractor shall ensure proper functioning of safety devices.
(xv) Contractor Shall provide the two mobile Number and two eamil IDs for regular communication.
-
-
-
Following repairs are deemed to be included in the rates quoted by the contractor under comprehensive maintenance
(a) CAR CABIN
(i) Repairs/replacement of acrylic roof cover.
(ii) Contractor is responsible for maintaining the car cabin neat and clean. Necessary cleaning to car cabin shall be done by the contractor on daily basis.
(b) CONTROLLER
(i) Checking fuses of controller and mains, replace if any found defective.
(ii) Checking the conditon of brake coil and replacement if required.
(iii) Checking flexible leads to relays to make them serviceable.
(c) AC Motor
(I) Lubricate bearings with suitable lubricants.
(ii) Clean ventilation passages on weekly basis.
(iii) Carryout the insulation test and continuity test of motor on quarterly basis and make them in satisfactory condition.
(iv) Checking the alignment of motor shaft and realigment of shaft.
-
-
-
(d) Governor
(I) Lubricate bearing on weekly basis with suitable lubricants.
(ii) Checking that the levers work smoothly.
(iii)Checking that electrical contact opens before rope get locked.
(e) Ropes
(I) Checking the condition of hoist and governor ropes (ii) Lubricate rope in case of non self lubricating ropes on weekly basis.
(iii) Checking the dia of rope and record in maintenance book on quarterly basis for its proper functioning.
(f) Hoist Way
(I) Lubricate guides and guide shoes on weekly basis with suitbale lubricants.
(ii) Checking that the bufffers are in proper, position measurement and record counter weight buffer cleans with car at the top.
(iii) Checking the rope fastening at the car and counter weight.
(iv)Checking guide clamps and adjusted.
(v) Checking to upper and lower limit switches for proper connection after physical inspection get the lift to over travel by holding from the controller and see that the switches operate properly.
(vi) Checking condition of travelling cables and termination at junction boxes
-
-
-
(g) Machine Room
(I) Checking and adjusting of overload relay and phase failure relay (ii) Checking power wiring termination in switch motor controller and power switching relays.
(iii) Checking/ lubrication of all equipment on weekly basis
(iv) Cleaning the machine room on daily basis
(v) Cleaning the relay contacts, replacement of contact
(h) Gear Box
(I) Inspect for stray noises .
(ii) Checking axial play of work shaft .
(iii) Lubricate bearing and top up oil in gear box when its required.
(j) Brakes
(I) Cleaning of oil surface and trace source of oil leakage and rectify the leakage problems.
(ii) Adjust clearance between shoes and drum on monthly basis.
-
-
-
(k) Retiring Car and Locks
(I) Checking operation of car and lock from the top at each landing checking that retiring car solenoid is not getting a over heated and that movement of car is smooth.
(ii) Checking that all locks are functioning properly, mechanically and electrically after opening the covers, checking all set screws and springs and replace if necessary. The lever should lock the brake properly.
(iii) Checking that the retiring car does not touch the lock roller at the landing which is being passed.
(iv) Checking the door closer safety, clean and adjust if necessary .
(v) Checking the car gear switch operates properly .
(vi) Lubricate top track and door motor and linkage.
(vii) Checking the landing door and can be operated by emergency keys.
(viii) Repair/replacement of retiring car solenoid locks doors closer safety switch.
-
-
-
(l) General
(I) Checking the car frame for bends or cracks and correct if required.
(ii) Checking and carrying out insulation resistance test half yearly basis for the follwing :- (a) All power circuit cables and incoming cables. (b) Switch and feed controller (c) Between different power relays. (d) Power card in the traveling cables (e) Motor
(iii) Checking operation of the car over speed safety gear by moving the levers manually landing so that the safety locks up properly.
(iv) Checking that sheaves are tight on the shaft also checking with hammer sounding for cracks, check sheave bearing clean and re-lubricate. Adjust for proper axial play.
(v) Unload car (s) checking the worn gear lash and adjust by removal of sheaves as required.
(vi) Checking of motor bearing, clean and lubricant
(vii) Checking that the gear coupling belts are tight
(viii) Checking oil seals of gear box and fill fresh oil
(ix) Contractor is responsible for maintenance of lift well/pit /shaft/machine room in dry and clean condition at all times. Any entry of water needs to be pumped immediately and rates quoted is inclusive of necessary pumping arrangement.A pump should be kept in store at all time to meet the emergency. No extra payment will be done in this account. Failing Rs 10,000/- recovered as penality per failure due to above reason
(x) Remove brake shoes clean and refit or replace brake linings inspect pins springs clean and reassemble. Checking that brake drum is not scored or worn unevenly.
-
-
-
(m) The following cmponent Replacement are deemed to be included in the rates quoted by the contractor under comprehensive maintenance against item Srl No 1 :
(i) Contractor is responsible for repair/replacement of following coponents :- Motors, generators, ropes, invertor systems, controller parts to be incusive of printed circuit boards, Sub componens inclusive of belts, gears, bearings, solenoids, coils, chocks brake shoes, liners, contacts, contactors, relays, push bottons, firemen switches, door operator WVF drive, car door safety device limit switches, governors, hoistway door locks, controller, handrails, handrail drive, steps and step chains, sub components belts, steps rollers, handrail bearing, safety switches, magnetic switches, combs, ARD battery 12V 17AH, LED light fitting 14 watt including Lamp, cabin fan 300 mm Sweep, Landing operating panel (LOP), false ceiling in Stainless steel hairline finish fabricated from 1.2mm thick SS sheet, LED light 06 watts, aluminium chequar plate 3mm thick, Door Motor, Door Sensor and Door Welding shall also be included for repair or replacement complete all as specified and directed. (n) Contractor is responsible for renewal of insurance. Load testing for lifts to be carried out once in a year through chartered Engineer and necessary test report shall be submitted.
-
-
-
Complete all as above item No 1.0 to 1.09 but for electrically operated ThyssenKrupp elevator (India) make passanger lift of capacity 884 Kgs carrying 13 passangers in S+5 (total 6 landing)
11
-
-
Complete all as above item No 1.0 to 1.09 but for electrically operated ThyssenKrupp elevator (India) make passanger lift of capacity 884 Kgs carrying 13 passangers in S+6 (total 7 landing)
11
-
-
Complete all as above item No 1.0 to 1.09 but for electrically operated ThyssenKrupp elevator (India) make passanger lift of capacity 544 Kgs carrying 08 passangers in S+6 (total 7 landing)
11
-
-
M&L for repair/replacement of steel wire rope 8 Pp 1370/1770 (Dual) Sz material No 1000040582
125
-
-
M&L for repair/replacement of Inverter Tke-1-24.5 11 kw OI/CI material No 1000043229.
1
-
-
M&L for Replacement of Pcb Mcu mother board Tic-V item code No. 1000043616 complete all as specified and directed.
2
-
-
M&L for Replacement of Pcb Ctu Tic-V item code No. 1000043830 complete all as specified and directed.
3
-
-
M&L for Replacement of Pcb Ccu scrollig Tic-V item code No. 1000043831 complete all as specified and directed.
4
-
-
M&L for Replacement of UPS Sua scrollig Tic-V item code No. 1000043831 complete all as specified and directed.
1
-
-
M&L for Replacment of battery 12V 18 AH item code No. 1000045623 complete all as specified and directed.
16
-
-
M&L for repair/replacement of D locking Device Ad material No 1000052350
10
-
-
M&L for repair/ Replacement of Asy Emg Alarm Unit HI with bend Newlogo Material No. 1000065883 complete all as specified and directed.
1
-
-
M&L for repair/ Replacement of IR 957B61-AC220V cable 3.5 mtr PS WECO material No 1000084700 complete all as specified and directed.
3
-
-
M&L for repair/ Replacement of Terminal limit switch AC/DC Material No 1000085613 complete all as specified and directed.
30
-
-
M&L for repair/ Replacement of D locking key ACO NBSL material No. 1000225528 complete all as specified and directed.
10
-
-
Supply, fixing and testing of MBBR media complete all as specified and directed.
10
-
-
Supply, fixing and testing of Tube setter media complete all as specified and directed.
8
-
-
Supply, fixing in repair and testing of butter fly valve 2" suitable for MS pipe 50 mm bore complete all as specified and directed.
8
-
-
Supply, fixing in repair and testing of foot fly valve 2" suitable for GI pipe 50 mm dia complete all as specified and directed.
4
-
-
Supply, fixing in repair and testing of air blower sunction filter suitable for 7.50 HP centrifugal motor complete all as specified and directed.
4
-
-
Supply, fixing in repair and testing of butter fly valve 4" dia suitable for UPVC pipe 100 mm bore complete all as specified and directed.
4
-
-
Supply, fixing and testing UPVC pipe 80mm dia 3 mtr incl gitting and GI pipe medium grade 50 mm dia 3 mtr incl fitting complete all as specified and directed.
4
-
-
Supply, fixing and testing of MGF media complete all as specified and directed.
800
-
-
Supply, fixing and testing of ACF media complete all as specified and directed.
275
-
-
Supply, fixing and testing of Microbes for bacteria growth complete all as specified and directed.
125
-
-
Supply and fixing in repairof pressure guage complete all as specified and directed
6
-
-
Supply, fixing and testing of rubber flange round 500 mm, 6mm thickness for existing ACF to prevent leakage complete all as specified and directed.
4
-
-
M&L for Cleaning of existing MS pipe of 200 KLD STP of any size with emery paper then application of red oxide as primer and finally application of two coat of synthetic enemal paint of existing colour complete all as specified and directed
4
-
-
M&L for Cleaning of existing raw water collection tank including bar screen chamber, oil screen chamber, sludge bed and filter feed tank complete of 200 KLD STP with necessary cleaning material/tool complete all as specified and directed
4
-
-
S&F in repair PVC insulated 3 core 6 sqmm copper multi stranded PVC sheathed submersible cable ISI marked and confirming to IS 694 and connecting submersible pump and to starter panel after takig out old unserviceable cable complete all as specified and directed
100
-
-
S&F Galvalum sheet 6 mm thickness on existing panel including fixing screw and washers etc complete all as specified and directed
8
-
-
M&L for chemical and micro biological test of outlet water of STP from NABL approved labs by contractor and submitted to MES complete all as specified and directed
4
-
-
Net Contract Sum will be after deducting Sch of Credit of Rs 46,480.00
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements