Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date7 Feb 2025
Closing Soon28 Feb 2025
Tender Amount₹ 49,95,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for sand cushioning with a layer of sand 80 mm thick before laying of cables and 150 mm thick after laying of cables in trenches, or in Existing duct as directed for electric cables for protection incl.consolidation complete all as specified and directed.

68

-

-

... More
M&L for brick protection with sub class B bricks,laid dry flat over electric cables in trenches complete all as specified and directed,

6.9

-

-

... More
Lifting and taking out the sewage submersible pump set and motor of capacity 10 to 15 HP including column pipe by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sewage sump /well and lowering back the pump after repairing /removing the sludge from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut bolts, washers/ packing to the existing header without any leakage complete all as directed. Note :- Rate are deemed to be inclusive for jointing of Submersible Cable , reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete.

10

-

-

... More
All as per item No. 6 desribed here in before but of capacity 2 HP to 7.5 HP complete all as specified and as directed .

25

-

-

... More
M&L for electric arc welding at places like flanges/pipe line, joints , strip of clarifier tank, approach ladder to aeration tank etc all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M&L for rewinding of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire, varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 10 HP to 15 HP complete all as specified and as directed . (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If submersible motor become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

6

-

-

... More
All as per Item No 9 but 5 to 7.5 HP Capacity

6

-

-

... More
M&L for repairing and testing of pump centrifugal/mono block/non clogging upto 5 to 12.5 HP of any make and type including welding work, rotor turning and balancing, re-metaling of shaft bush bearing, keys, mechanincal seal, SS shaft impeller and any other accessories required to make pump functional and testing on load complete all as specified and as directed . (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If monoblock pump/motor become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

5

-

-

... More
M&L for repairing of electric motor upto 5 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If monoblock pump/electric motor become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

5

-

-

... More
M&L for repairing of electric motor 15 to 20 HP 50 Hz 400/415 volts of mono block/centrifugal pump of any make and type with super enameled copper winding wire including bearing bushes, varnishing and stamping and overhauling. making the winding leak proof etc. and other accessories etc required to make motor functional and testing on load complete all as specified and as directed . (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If motor/pump become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

2

-

-

... More
Disconnecting and taking down treated sewage transfer pump set up to 15 HP horizintal type and replacement of burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire including bearing bushes, mechanical seal rotor tunring & balancing, shaft SS impeller varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter and re-assembling and fixing the pump set complete in the same location and testing all as specified and as directed . (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) REplacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If monoblock pump become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

2

-

-

... More
M & L for servicing of air blower with positive displacement type twin lube root blower with Motor of 12.5 HP to 15 HP capacities, including Opening the blower motor blower shaft, shaft Key ways, shaft holes etc and M & L for replacing the gland packing, gland nuts, coupling, replacement of oil seal including oil and rewinding of blower motor with super enameled copper winding wire as per existing size including re-fixing the same to the original position and commissioning testing complete all as specified and as directed . (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) REplacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If Air blower become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

6

-

-

... More
S & F Fan belt B-45 suitable for Air blower including taking down complete all as specified and directed.

10

-

-

... More
M & L for Periodical Cleaning of collection tank/equalizing tank /grit chamber/ oil grease chamber/stilling chamber of Sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required all as required at site and directed by the Engineer-in-Charge at AF Stn Gurgaon for Sewage tank of STP 500 KLD of under mentioned sizes complete all as specified and directed :- (a) Collection tank dia 6m and depth 9m x 4m - (Sump Well/ Equalization tank). (b) Screen/ grid Chamber. (c) Aeration tank - dia-9m and depth 5m. (d) Clarifier - dia 7.4 mtrs and depth 4.5 mtrs. (e) Sludge drying bed of size 10 m x 4.5 m x1.5m. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same sludge ha to be deposited at least 5 KM away from the Defence Land/Station. Mechanical cleaning of all the chamber sewage lines with clean water and reuse for proper functioning complete all as specified and as directed. Note : Pumping out sludge water from MBBR tank by using diesel engine operated pump is to be arranged by the contractor . (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in- Charge.

3

-

-

... More
M & L for Cleaning of filter medial tank (ACF & DMF) , pumping out all sludge and foreign material including washing the entire tank and scraping the walls with wire brushes and making good the patches on walls internally or externally where required all as specified and directed by Engr-in-Charge. (Make: MM Aqua/Venayaka Engineers/ Ion Exchange)

3

-

-

... More
Supply and pouring Bio media made of plastic and corrugated shape having surface area 260 sqm/cum in MBBR as directed by Engr-in-charge

5

-

-

... More
Supply only DWPE chemical for sewage treatment plant.

150

-

-

... More
Material and labour for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge.

200

-

-

... More
Material and labour for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge

200

-

-

... More
Material and labour for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge.

200

-

-

... More
Material and labour for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge.

200

-

-

... More
Material and labour for replacement of activated carbon IV 1000 complete all as specified and directed by Engr-in-charge.

100

-

-

... More
Taking out complete pebbles from the filter and and refilling the same pebbles after washing /cleaning thoroughly complete all as specified and directed by Engr-in-charge.

2

-

-

... More
M & L for Periodical Cleaning of equalizing tank /grit chamber/ oil grease chamber/stilling chamber of sewage Water in the tank and Removing of settle down Sewage sludge cum mud/De-Silting etc and making good the patches on walls internally or externally in cement mortor 1:3 where required all as required at site and directed by the Engineer-in-Charge at AF Stn Gurgaon for Sewage tank of STP 300 KLD of under mentioned sizes etc complete all as specified and directed :- (a) Equilizer tank/ /grit chamber/ oil grease chamber/stilling chamber of Sewage Water of size - 6.30m x 4.70m x 6m - 01 No. (b) Sludge holding tank of size - 2.6mx2.6mx3m-01 No. (c ) Fab-1 & Fab-2 of size - 2.1m x 2.1m x 5.80m - 02 Nos. (d) Tube Settler Tank - 4.1m x 2.5m x 3.8m - 01 No. (e) Treated water Tank 9.3 m x 3.4 m x 4.1m-01 No. Note: The rate quoated by the tenderer is deemed to be included in the unit rate of the following :- (a) Diesel Driven Pump Set of appropriate capacity with operators including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Lorry/Tractor mounted septic storage tank of appropriate capacity not less than 3 KL should be used for disposing off the same sludge ha to be deposited at least 5 KM away from the Defence Land/Station. Mechanical cleaning of all the chamber sewage lines with clean water and reuse for proper functioning complete all as specified and as directed. Note : Pumping out sludge water from MBBR tank by using diesel engine operated pump is to be arranged by the contractor . (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in- Charge.

3

-

-

... More
Supply and mixing of Sodium hypochloride having 10% chlorine content etc required at site and all as directed by the Engineerin-Charge.

2500

-

-

... More
Supply and mixing of Poly aluminium chloride 100% purity etc required at site and all as directed by the Engineerin- Charge.

2000

-

-

... More
M&L for repair,servicing,fixing, testing and commissioning of existing 0-6 LPH electrically operated, metered, adjustable dosing pump with accssories including lead tubing , connecting nuts injection check valve with 60 ltr PE/ FRP tank fitted with agiatator all as directed by engineer -in - charge E tank with PE/FRP/HDPE lid and level gauges, mounted on tank all as specified and directed by Engineer -in-charge .

2

-

-

... More
M & L for carrying sample testing of sewage water as per relevant IS of STP and submission of detailed test report to the office of the Engr-in-charge and testing in Govt approved laboratory as approved by GE. (a) Carrying out minimum essential testing of sewage water as per relevant IS mandatory for chemical, odour, PH value,TSS, BOD, COD, total nitrogen, sulphate, oil and grease, ammonical Nitrogen (NH3-N) and Bacteriological total colliform organism and other characterstics as per relevant IS of sewage water. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate.

16

-

-

... More
M & L for Carrying sample for testing of treated water of STP and submission of detailed test report to the office of the Engineer-in-charge. Details are as under:- (a) carry ing out minimum essential testing of treated water as per IS 3025 & IS 1622 mandatory for chemical , colour, odour, PH value, TSS, BOD,COD, Total residual chlorine, total Nitrogen, sulphate, oil and grease, Ammonical nitrogen(NH3-N) and Bacteriological total coliform organism per 100ml (MPN) and Ecoli in 100ml. (b) Treated sewage water shall confirm to the following characterstics:- (i) TSS : 10 mg/litre. (ii) BOD : 10 mg/ litre. (iii) COD: 150 mg/litre. (iv) Ph: 6.5 -8.5. (v) Total coliform: 100 MPN/100 ml (desired nil). (vi) Resudual CI 1 mg/litre. Rest of the characterstic of the treated water shall be as per IS 3025 & IS 1622. (i) Cost of sterilized bottle as required. (ii) cost of sample collection from Site to laboratory including transportation charges are included in the quoted rate.

16

-

-

... More
Supply & filling compressure oil all as specified and directed by Engineer - in- charge .

20

-

-

... More
Supply, laying , jointing, welding & testing MS pipe ( Heavy duty Class 'c') including fitting as required of following sizes laid in treches or laying or floor for connecting to various STP accessories and to connect outgoing water main from Non clogging submersible pump including taking down the unserviceable pipe all as directed by Engr-in-charge. Note:- MS flange and flange joint, bends etc complete with jointing material shall deemed to be included in the unit rate of this item.

-

-

-

... More
(a) 100 mm bore

60

-

-

... More
(b) 80 mm bore

60

-

-

... More
(c) 65 mm bore

20

-

-

... More
(d) 50 mm bore

30

-

-

... More
(e) 40 mm bore

30

-

-

... More
(f) 150 mm bore

18

-

-

... More
S & F in repair GI tubing and connections including all fittings such as bends, belows tee, unions, sockets, flange welding on both side of a length of 6 mtr span etc or laid complete in trenches of size 50mm dia including taking down etc complete all as specififed and directed.

54

-

-

... More
M & L for High density polyethylene pipes (HDPE) of size 50mm of pressure rating 6 Kgf/cm2 fixed complete laid in trenches etc complete all as specified and directed.

24

-

-

... More
M & L for High density polyethylene pipes (HDPE) of size 90mm of pressure rating 6 Kgf/cm2 fixed complete laid in trenches etc complete all as specified and directed.

24

-

-

... More
M & L for Earthing complete with GI earth plate electrode 600 mm x 600 mm x 600 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised strip 25×4mm mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth pit surrounded by picked layer of coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 50mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 6mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.

4

-

-

... More
Supply and fix cast iron flanged drilled heavy duty sluice valve 150 mm dia with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion, nuts and bolts with washers etc complete all as directed by Engr-in-Charge. Note. Rate for Nuts, bolts, gasket, etc. shall be included in the unit rates.

2

-

-

... More
Supply and fix cast iron flanged drilled heavy duty sluice valve 100 mm dia with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion, nuts and bolts with washers etc complete all as directed by Engr-in-Charge. Note. Rate for Nuts, bolts, gasket, etc. shall be included in the unit rates.

10

-

-

... More
Supply and fix in butterfly valves suiatable for GI/MS pipe complete including dismantling the old one all as specified and as directed by Engr-in-Charge for the following sizes :-

-

-

-

... More
(a) 100 mm bore

2

-

-

... More
(b) 80 mm bore

4

-

-

... More
(c) 65 mm bore

4

-

-

... More
(d) 50 mm bore

6

-

-

... More
(e) 150 mm bore

1

-

-

... More
Supply and fix Gun Metal globe or Gate valve iron wheel head screwed both ends for iron pipes of size 50mm dia bore complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fix in replacement MCCB 100 A ,3 pole ,25 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make : L&T/Schneider/Siemens

2

-

-

... More
Supply and fixing in replacement of MCCB 250 A, 4 pole, 36 KA with adjustable thermal magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make :- Legrand/Schineder /Siemens/L&T

1

-

-

... More
Supply and fix in replacement MCCB 160 A ,3 pole ,36 KA with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning all as specified and as directed by the engineer-in-Charge. Make : L&T/Schneider/Siemens

1

-

-

... More
Supply and fixing in replacement of flat submersible 3 core 6 sqmm cable PVC insualted unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.

450

-

-

... More
Supply and fixing in replacement of flat submersible 3 core 10 sqmm cable PVC insualted unsheathed multistranded copper conductor water proof suitable for submersible pump set complete all as specified and as directed.

140

-

-

... More
Supply and fix in replacement of cast iron pipes with spigot and socket ends centrifugally cast 100mm dia size Class LA, in any length, laid in trenches all as specified and as directed.

30

-

-

... More
Supply and fix in replacement of cast iron pipes with spigot and socket ends centrifugally cast 150mm dia size Class LA, in any length, laid in trenches all as specified and as directed.

144

-

-

... More
M&L for CI fitting for spigot and socketed pipes such as bends (any type, radius and angle) Tapers any type (straight, bend, increasing or double socket etc) Tee pieces single branch 'Y' juction double branch cross (all sockets or socket and spigot) collars, caps and plugs of any size complete all as specified and as directed.

155

-

-

... More
M & L for trenchless boring under roads/ crossing or fixed to wall/ pole, GI tubing light grade of size upto 150mm bore for protection of UG cables complete all as specified and as directed.

6

-

-

... More
Supply, laying and testing cable XLPE insulated, screened, PVC badded,galvanised steel strip or wire armoured, Heavy duty, electric power cable with Aluminum conductor 1100 Volts Grade, Cross-Sectional area as mentioned under complete all as specified and directed.

-

-

-

... More
(a) 35 Sqmm, 3.5 core

300

-

-

... More
(b) 50 Sqmm, 3.5 core

300

-

-

... More
(c) 70 Sqmm, 3.5 core

150

-

-

... More
S & F in replacement MS Coloumn pipe of bore 100 mm and 3 meter length with socket of size 100 mm dia 6 mm thick duly screwed as well as welded on both ends , lowering and fixing into the Sewage well by using nuts, bolts , gasket and washers complete all as specified and diected by Eng-in-charge.

13

-

-

... More
M & L for CI non return valve of size 100mm dia PN 1.6 including flage and Nut, bolts, washer etc including taking down old complete all as specified and directed by Engr in charge..

4

-

-

... More
M & L for CI non return valve of size 150mm dia PN 1.6 including flage and Nut, bolts, wahsher etc including taking down old complete all as specified and directed by Engr in charge.

6

-

-

... More
M&L for 3-Layer PP-R Polypropylene random copolymer concealed pipes of outer dia 160 mm SDR 7.4 & PN-16 UV stablised and antimicrobial fusion welded having thermal stability for cold water supply all PP-R plain & brass threaded polypropylene random complete making connection as required at site and laid in trenches all as specified & directed.

24

-

-

... More
Complete all as per item No 56 above but outer dia 110 mm size

70

-

-

... More
Complete all as per item No 56 above but outer dia 90 mm size

30

-

-

... More
Complete all as per item No 56 above but outer dia 75 mm size

12

-

-

... More
Complete all as per item No 56 above but outer dia 63 mm size

12

-

-

... More
Complete all as per item No 56 above but outer dia 32 mm size

18

-

-

... More
M&L for construction of Valve pit chamber 90 cmx90cm (inner dimension) and 90 cm deep , from the top of MS cover fixed on PCC Base , top cover shall be of 3 mm thick MS Sheet with locking arrangement of pad lock of 50mm size including brick work with sub class"B" bricks in CM 1:4 including 15 mm thick plaster in CM 1:4 (internally and externally) and necessray earth work in anu type of soil including returning filling in and disposal of surplus oil to a distance n exc 50 mtrs and 150 mm thick PCC 1:4:8 , type D-2 , using 40mm graded stone aggregates as in floor complete all as specified and directed.

8

-

-

... More
S&F in replacement of water pop up sprinkler head irrigation system for garden Lawn Patio 180 degree of dia 32 mm bore including 0.5 mtr long 32 mm inner dia PP-R pipe, socket of any type and other fixing material for fixing with PP-R pipe all as directed and specified. Note: All fixing material is included in the unit rate. Sprinkler will be fixed ever 90 mm.

31

-

-

... More
Disconnecting/removing the old unserviceable burnt parts from the FASD starters and supply and fix the new items as per exiting the model for AC 415 V,50 HZ 3 phase suitlable for lthe motors all as directed by the Engineer-in-charge.

-

-

-

... More
(a) Power Contactor, 3 pole, MNX-12 with front mounting Aux contacts block1 NO + 1NC of range AC1 -30 A & AC3 - 12 A of Make - L&T Cat No. CS94108 and Aux contat block Cat No CS94112^

5

-

-

... More
(b) Power Contactor, 3 pole, MNX-18 with front mounting Aux contacts Block1 NO + 21NC of range AC1 - 30 A & AC3 - 18 A of Make - L&T Cat No. CS94100 and Aux contact block Cat No CS94112^

5

-

-

... More
(C) Power Contactor, 3 pole, MNX-22 with front mounting Aux contacts 1 NO + 21NC of range AC1 - 32 A & AC3 - 22 A of Make - L&T Cat No. CS94980 and Aux contact block Cat No CS94113^

5

-

-

... More
(d) Power Contactor, 3 pole, MNX-25 with frot mounting Aux contacts 1 NO + 21NC of range AC1 - 45 A & AC3 - 25 A of Make - L&T Cat No. CS94110 and Aux contact block Cat No CS94114^

4

-

-

... More
(e) Power Contactor, 3 pole, MNX-32 with Aux contacts 1 NO + 1NC of range AC1 - 55 A & AC3 - 32 A of Make - L&T Cat No. CS94110

6

-

-

... More
(f) Power Contactor, 3 pole, MNX-40 with Aux contacts 1 NO + 1 NC of range AC1 - 55 A & AC3 - 40 A of Make - L&T Cat No. CS94190 and Aux contact block Cat No CS94114^

5

-

-

... More
(g) Power Contactor, 3 pole, MNX-45 with Aux contacts 2 NO + 2 NC of range AC1 - 80 A & AC3 - 45 A of Make - L&T Cat No. CS97074

2

-

-

... More
(h) Power Contactor, 3 pole, MNX-50 with Aux contacts 2 NO + 2 NC of range AC1 - 85 A & AC3 - 50 A of Make - L&T Cat No. CS97076

2

-

-

... More
(j) Power Contactor, 3 pole, MNX-70 with Aux contacts 2 NO + 2 NC of range AC1 - 100 A & AC3 - 70 A of Make - L&T Cat No. CS97076

1

-

-

... More
(k) Power Contactor, 3 pole, MNX-80 with Aux contacts 2 NO + 2 NC of range AC1 - 100 A & AC3 - 80 A of Make - L&T Cat No. CS97077

1

-

-

... More
(l) Power Contactor, 3 pole, ML-2 with Aux contacts 2 NO + 2 NC of range AC1 - 40 A & AC3 - 32 A of Make - L&T Cat No. SS90701

3

-

-

... More
(m) Bimetal over load relay MN-2 type directly mounted/operated of range 9-15 Amp of Make L&T Cat No. SS94142OOVO

3

-

-

... More
(n) Bimetal over load relay MN-2 type directly mounted/operated of range 14-23 Amp of Make L&T Cat No. SS94144OODO

2

-

-

... More
(o) Bimetal over load relay MN-5 type directly mounted/operated of range 30-50 Amp of Make L&T Cat No. SS94136OOGO

2

-

-

... More
(p) Bimetal over load relay MN-5 type directly mounted/operated of range 66-110 Amp of Make L&T Cat No. SS94137OOKO

2

-

-

... More
(q) single phase preventer suitable for 3 HP to 60 HP pump sets

4

-

-

... More
Maintenance of Olympic size swimming pool by removing of dirt, sludge, foreign material from wall and floor of swimming pool by using of brushes, rope etc and by the help of suction sweeper complete all as specified and directed, Note Rate quoted shall include the cost of all tools, expendable materials like brushes broom, rope and minor repair/welding work in suction sweeper brush assembly / trolley etc

90

-

-

... More
M&L for painting to motors, pump sets upto 15 HP including MS Channels, suction and delivery pipes of pump sets up to 5 M length from Pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of synthetic enamel paint with proper colour codes and writing letters of SM No. and MES No. etc., complete all as specified and directed.

5

-

-

... More
Disconnecting Monoblock pumping set, 15 HP capacity (any make), separating from suction, delivery pipeline, electrical connection etc. dismantling the same for repairing and replacing the unserviceable spare parts such as gland, packing, bearing bush, washer, ball bearing, bushes, neckring, Motor fan etc. and re-installing, making connection suction and delivery side with necessary new packing material, nut bolt etc. complete all as specified. (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If monoblock pumpset become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

5

-

-

-

-

-

... More
M&L for rewinding of electrical motor of capacity 15 HP, 3 Phase, 50 Hz, AC supply and carry out following repair/ rewinding and overhauling of pump complete all as required at site: (i) Cutting thoroughly burnt out defective winding (ii) Cleaning stator body complete by rubbing sand paper and to remove carbon (iii) Rewinding the stator with super enameled copper wire of existing size and reassemble complete motor pump and testing complete all as specified and as directed. (iv) Disconnecting electrical connection from pump and motor. (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If monoblock pump/motor become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

2

-

-

... More
M&L Silica Quartz sand with pebbles of multi grade sand filter as per the existing by size wise and layer wise after taking out the old sand complete all as specified and as directed.

1500

-

-

... More
Supply and pouring PH correction chemicals (Soda Ash) for smooth functioning of Swimming Pool

100

-

-

... More
Supply and pouring Crystal Alum complete all as specified and directed.

1300

-

-

... More
Supply and pouring Copper Sulphate complete all as specified and directed.

97

-

-

... More
Supply and pouring high strength Calcium base chlorine Granules TCC 90 complete all as specified and directed.

1400

-

-

... More
S&F of Cast Iron Air Valves with two air outlets, 150mm dia bore and fixing up in cast iron water supply mains. Note: Fixing materials is included in overall cost quoted by the contractor

1

-

-

... More
Supply and fixing wafer type cast iron butterfly valves tested to 10 kg/sq.cm pressure (including flanges & All other accessories) complete all as specified and as directed by Engr in charge. (a) 80mm (OD 90 mm)

1

-

-

... More
(b) 150mm (OD 160 mm)

1

-

-

... More
(c) 100 mm (110 OD)

1

-

-

... More
M&L for servicing of Centrifugal pump set by disconnecting, dismantling the three phase induction motor 415 Volts 50 Hz of centrifugal pumpset 40 HP 1440 RPM and winding the same with super enamelled copper wire of best quality of existing size/gauge and weight including replacement of insulation material, varnish,bearing, connection plate and all other petty items like Shaft sleeve DE/NDE made of Bronze, casing wear ring DE/NDE made of Stainless steel, Bearings as per sample etc required to make motor functional and re-assembling the motor including installation, commissioning and testing on full load all as specified and directed. Notes :- (a) Transportation charges from installation to contractor's workshop and back after repair are deemed included in the rate quoted in the item. (b) Cost of nuts, bolts, washers, connection plate, grease lubrication to bearing bushes etc are deemed included in this rate. (c) Old dismantled winding wire will be contractor’s property for which credit shall be affected as per schedule of credit. (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If motor become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

2

-

-

... More
Disconnecting, dismantling of Centrifugal monoblock pumpset of capacity 40 HP 1440 RPM and dismantling of defective parts such as Impeller nut , gland , impeller key, gland packing, water deflector, bush bearing sleeve, gaskets, volute stud and nuts , suction and delivery flange and stud and nuts, gland bolts and nuts Gun metal impeller etc and all other petty items like split gland made of Cast Iron, set of gasket made of asbestos, gland packing, coupling of suitable size for motor etc required to make pump functional and re-assembling the pump with motor including installation , commission and testing on full load complete all as specified and directed by Engg-in-charge. Notes:- (i) Transportation charges from installation to contractor work shop and back after repair are deemed included in the rate quoted for the above item. (ii) Cost of nuts, bolts, washers,, grease lubrication to bearing bushes etc are deemed included in this rate. (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) REplacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If pump become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

2

-

-

... More
Supply and fixing cast iron Foot valve 150 mm dia having matching flange including all fitting and accessories. complete all as specified and as directed by Engr in charge.

4

-

-

... More
S&F in replacement of under water LED light 18 watt, DC supply type, as per on site and making complete system water proof by selant and rubber washers and necessary wiring work, complete all as specified and directed. Note : Necessary arrangement like mapower , electrician, T&P, dewatering pump etc is deemed to be included in quoted rate.

12

-

-

... More
M&L for cleaning and removing out sludge/ silt/ solid deposits by suitable capacity of Non- Clogging centrigugal pump/ sewage tanker of the following tanks and cleaning with bleaching powder and sodium hypo chloride and deposited of sludge material outside the campus. Note: - Contractor shall arrange pump/ sewage tanker/ Iron ladder of suitable capacity/ safety belt for human precaution/ chain pulley/ tee poy/ hydra and other T&P items as required at site. Rate quoted by the contractor shall include all the resources in unit rate. (i) Collection tank dia 3m and depth 10m - (Sump Well/ near out side IMAC gate)-01 No and 5.0x5.30 m of depth 10m-01 No. (ii) Screen/ grid Chamber 2.6mx2.6mx3m-01 No. (iii) Aeration tank - 2.6mx2.6mx3m-01 No (iv) Clarifier - 4.7mx2.8mx2m-01 No. (v) Equalization tank 6 m x 4.5 m x9.5m-01 No.Note : Pumping out sludge water from MBBR tank by using diesel engine operated pump is to be arranged by the contractor . (c ) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects to be observed including necessary Phawda, Steel Bucket, Manila rope etc. required at site and all as directed by the Engineer-in- Charge.

2

-

-

... More
M&L for replacing existing damaged Bar screen with new bar screen of size 40 cm x 40 cm x 60 cm by using stainless materials at equalizer tank and grid chamber. Note: All fixing material shall included in the unit rate.

3

-

-

... More
M&L for replacing existing coarse/fine Bubble silicon membrane diffusers 1000 mm (for collection tank and MBBR). complete all accessories inside the MBBR tank and equalization tank as size above against sr No. 81.

1

-

-

... More
M&L for replacing the unserviceable MBBR media with new FAB/MBBR media Note: Pipe & fitting will be measured and paid separetly.

2

-

-

... More
Taking out the existing waste lifting non clogging sewage pump with motor monoblock set of capacity 2 Hp and refixing after replacement of impller, ball bearing, lock nut, gland, gland packing, suitable size nuts and bolts, including rewinding of motor by super enamel copper wire as per existing gauge/size with complete heat varnish and including necessary newPVC insulated, PVC sheathed multi stranded copper conductor submersible flat/round cable 3 core 6 sqmm 1100 V grade, 2 run through flexible conduit pipe from panel board to motor including painting of pump motor baseplate complete . Note: All fixing material and painting of pump and motor shall included in the quoted rate. (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If monoblock pump/motor become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

3

-

-

... More
Taking down the existing pump and motor non clogging type/ monoblock set of capacity 3 Hp and refixing after replacement of impller, ball bearing, lock nut, gland, gland packing, suitable size nuts and bolts, including rewinding of motor by super enamel copper wire as per existing gauge/size with complete heat varnish and including necessary new PVC insulated, PVC sheathed multi stranded copper conductor submersible flat/round cable 3 core 6 sqmm 1100 V grade, 2 run through flexible conduit pipe from panel board to motor including painting of pump motor baseplate complete. (Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If monoblock pump/motor become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

2

-

-

... More
Taking out filter media from flter plant and Supply & Replace Filter media of Pressure Vessel ACF DMF FRP, 42"X72", with pebble Gravel, coarse sand.

4

-

-

... More
Taking out U/S ACF carbon from pressure vessel Supply & Replace Pressure Vessel ACF Carbon replacement FRP, 42"X72", with activated carbon (make: Euro/Agro/Aster)

2

-

-

... More
Taking out unserviceable multiport block valve 2" dia 5 way and supply and fixing multiport block valve 2'' dia 5 way with handle complete set.

2

-

-

... More
Material and labour for chemicals like urea, DAP, Gur and Cow dung for areiation tank are as under.Note: Urea-100Kgs, DAP-50Kgs, Gur-50Kgs, Cow Dung-100 Kgs complete all as directed.

1

-

-

... More
S & F in replacement MS Coloumn pipe of bore 80 mm and 3 meter length with socket of size 80 mm dia 6 mm thick duly screwed as well as welded on both ends , lowering and fixing into the Sewage well by using nuts, bolts , gasket and washers complete all as specified and diected by Eng-in-charge.

3

-

-

... More
M&L for servicing of Submersible motor by taking out burnt copper winding, cleaning the casing & slots with wire brush & washing with pressure water & shall be dried , rewinding the motor using required gauge of super enameled copper winding wire, varnishing and stamping and overhauling etc. Making the winding leak proof & taking out the electric connection with suitable size of submersible cable up to 03 Meter, Capacity of motor 7.5 HP to 12.5 HP complete all as specified and as directed .(Note: (i) Cost of all spare parts included in quoted rates to make serviceable in complete (ii) Transportation charges are deemed to be included in quoted rates (iii) Replacement of any unserviceable/defective /burnt part is also included in quoted rates (iv) If submersible motor become unserviceble due to any reson during the contract period, the contractor will get it repair or replacement at no extra cost )

5

-

-

... More
Repair/Maintenance of existing dosing system to make it functional in all respect all as specified and directed by Engr-in-Charge. Note:- Unit rate quoted by Contractor shall also be deemed to included replacement of defective part.

1

-

-

... More
M&L for earthing complete with galvanised iron earth plate electrode of the size 600 mm x 600 mm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 32 x 6 mm by means of bolts ,nuts.chuck nuts and washers of galvanised iron or .steel watering pipe of 20 mm bore , galvanised iron medium grade of 40 mm bore galvanised iron light grade of earth wire protection including all excavation earth work in any type of soil ,PCC pit with RCC pit cover , charcoal,salt,funnel complete all as shown in electrical plate No-3 of SSR Part-I & Testing on completion. Note: Quoted rates shall be including for earth strip with protection pipe upto 7.5 mtr length.

4

-

-

... More
M&L for electric arc welding at places like flanges/pipe line, joints , strip of clarifier tank, approach ladder to aeration tank etc all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F Tube Settler Manual drain all as specified and directed by Engr-in-Charge.

1

-

-

... More
Taking up or down steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-

-

-

-

... More
(a) 20mm bore

30

-

-

... More
(c) 50mm bore

24

-

-

... More
S & F in repair steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-

-

-

-

... More
(a) 20mm bore

30

-

-

... More
Repair & maintenance of Tube Settler Size 80 x 750 Pvc 60 completed all as specified and directed.

1

-

-

... More
Maintenace of STPs of following sizes of 150 KLD including cleaning of Sewage system replacement of damaged section of sewage lines, rectifcation of sewage blockages etc complete to ensure smooth and trouble free operation of sewage system all as specified and as mentioned below:-.

9

-

-

... More
i) Checking of regular parameters required for smooth operation of STP. ii) Ensure desired water quality and quantity. iii) All necessary measures to be taken for satisfactory operation of plant. iv) Regular cleaning of bar screen. v) Regular backwash and rinsing of Multi-grade filter, and Activated carbon filter. vi) To undertake regular preventive maintenance of the mechanical equipment’s such as pumps, valves etc and take corrective action in order to ensure smooth operation of the STP. vii) Checking of oil & grease and servicing of all blowers and gear boxes. viii) Physical monitoring of abnormal sound, alignment of pumps, motors, blowers, ix) To check and repair the Electrical LT panel including its components and it’s wiring for proper functioning. x) Clearing sludge bed on regular basis.

-

-

-

... More
Note: i) The rates quoted are deemed to be inclusive of Repairs and replacement of spares as and when required. ii) Contractor shall ensured that only trained technicians should repair to make the plant opeartional within 3 to 4 hours by repairing the faulty system in case of repair. Cost of replacement of spares shall be measured and paid under relevant items of schedule. Failure of operation of plant will be penalised @ Rs 1000/ per day. No extra payment will be done on this account.

-

-

-

... More
Nature of effluent - Domestic Sewage from toilet, Kitchen waste water medical waste shall be discharged into the STP.

-

-

-

... More
(Approximate characteristies of the inlet flow of sewage

-

-

-

... More
pH - 6.5 – 8.5

-

-

-

... More
BOD - 250-400 Mg/L

-

-

-

... More
S. Solids - 150-450 Mg/L

-

-

-

... More
COD - 600-800 Mg/L

-

-

-

... More
Oil & Grease - upto 50 Mg / L

-

-

-

... More
DISCHARGE EFFLUENT CHARACTERSTICS REQUIRED AFTER TREATMENT

-

-

-

... More
pH - 6.0 – 8.5

-

-

-

... More
BOD - Less than 30 Mg/L

-

-

-

... More
S. Solids - Less than 100 Mg/L

-

-

-

... More
COD - Less than 100 Mg/L

-

-

-

... More
Oil & Grease - Less than 5 Mg / L

-

-

-

... More
Sewage treatment plant shall include the following items:-

-

-

-

... More
Grit chamber

-

-

-

... More
Screen Chamber

-

-

-

... More
Oil & Grease Trap

-

-

-

... More
Sewage equalization tank/sump

-

-

-

... More
Tube Settler Tank

-

-

-

... More
Sludge Holding Tank

-

-

-

... More
Air Blowers, Pumps & equipment

-

-

-

... More
Piping, valves etc

-

-

-

... More
Irrigation / Flushing Water tank

-

-

-

... More
Tertiary Treatment MGF/ACF

-

-

-

... More
Electrical Panel & Cabling

-

-

-

... More
Desludging the following existing chambers and getting out through sucking super soccer machine or any other method and same has to be deposited at least 5 km away from the Defence area/ station. mechanical cleaning of all the chamber sewage lines with clean water and reuse for proper functioning complete all as specified and as directed. Note: Pumping out sludge water from MBBR tank by using diesel engine operated pump is to be arranged by contractor

-

-

-

... More
Sewage well

9

-

-

... More
Filter Feed tank

1

-

-

... More
MBBR tank

9

-

-

... More
Tube Settler Tank

5

-

-

... More
Chlorine tank

1

-

-

... More
Treated water tank

1

-

-

... More
Collection tank

9

-

-

... More
Screen Chamber

9

-

-

... More
Oil and grease Chamber (3 m3)

5

-

-

... More
S&F of air diffuser rod type at least 1mt long with rubber coating and SS mouth diffuser and SS clamps after removing water & sludge from equalizer tank & MBBR tank, complete all as specified and directed. Note :- Contractor shall make alternative arrangement to meet the sewage disposal during the the desluding period. The rates quoted shall be deemed to inclusive of such arragement and no extra payment will be done on this account.

3

-

-

... More
M&L for Cleaning & Replacement of unserviseble sand media from sludge drying beds, and filling with clean and fine river sand or New Media for Sludge Drying Bed in layers complete all as specified and directed.

9

-

-

... More
M&L Bio Culture complete all as specified and as directed by Engr-in-Charge.

80

-

-

... More
M&L liquid chlorine all as specified and as directed by Engineer -in-charge.

480

-

-

... More
M&L MBBR media cylindrical with extended fin, black in colour of superior quality and UV stable complete all as directed by Engineer-in-charge

3

-

-

... More
M & L for servicing of air blower with positive displacement type twin lube root blower with Motor of Various capacities, including Opening the blower motor blower shaft and shaft Key ways, shaft holes etc and replacing the gland packing, gland nuts, topping up engine lubrication oil and coupling as per existing size including re-fixing the same to the original position and commissioning testing complete Note :- The rate quoted shall be deemed to include all necessary spare parts required to make the system serviceable during the contract period. (ii) If the blower becomes damaged or unserviceable due to any reason during the contract period, the contractor will get it repaired.

1

-

-

... More
M & L for installing electrical timer in existing electrical LT panel for air blower for auto working with inter-locking system between both air blowers. Time setting between both blower in manual way and including all accessories. complete all as directed by Engineer-in-charge

1

-

-

... More
Labour only for lifting /taking out the non clogging sewage submersible pump set and motor of capacity upto 5 HP including column pipe of any bore by dismantling nut bolt washers and rubber packing etc including disconnecting of submersible cable complete from the sewage equalizer tank of depth up to 7 meter and lowering back the pump after repairing /removing the sludge from the pump including making electrical connection with the existing panel /starter and connecting the complete the column pipe assembly with nut ,Bolts,washers/packing to the existing header without any leakage complete all as directed. Note for :- Rate are deemed to be inclusive for jointing of Submersible Cable upto 7mtr, Steel wire of suitable gauge tied with motor before lowering down upto the depth of motor, reconnecting the delivery pipe line of submersible pump sets to water mains , testing for satisfactory running & continuous flow of water complete all as specified.

3

-

-

... More
M&L for rewinding of electric motor monoblock 3HP 50 HZ 400/415 volts of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed .Note :- The rate quoted shall be deemed to include all necessary spare parts required to make the system serviceable during the contract period. (ii) If themotor becomes damaged or unserviceable due to any reason during the contract period, the contractor will get it repaired.

1

-

-

... More
M&L for rewinding of electric motor 5HP , 50 HZ 400/415 volts of non clogging/ mono block/centrifugal elctric motor of any make and type with super enameled copper winding wire including bearing bushes and other accessories etc required to make motor functional and testing on load complete all as specified and as directed ..Note :- The rate quoted shall be deemed to include all necessary spare parts required to make the system serviceable during the contract period. (ii) If the motor becomes damaged or unserviceable due to any reason during the contract period, the contractor will get it repaired.

3

-

-

... More
Supplying and connecting PVC insulated flexible flat 3 core submersible cable with copper conductors of size 10 sqmm from control panel to non clogging motor for STP installation complete all as specified & directed by Engineer in charge.

125

-

-

... More
Testing of Sewage water as per relevant IS of STP & submission of detailed NABL approved laboratory test report to the office of the Engineer-in-charge must comprise of following specifications:- (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value, TSS, BOD,COD total nitrogen, sulphate, oil and grease ammonium Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water. Notes :- Rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and from transportation charges for collection of sample

9

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.