Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 79,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684568_1Tender No
CWE/HSR/41 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
186
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
150
-
-
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
10
-
-
M & L for treating the backfill in contact with foundation at the rate of 7.5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of vertical surface complete all as specified and as directed. (Area of the sub structure in contact with backfill to be measured).
69
-
-
M & L for treating the soil under plinth protection, apron etc. at the rate of 5 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per square metre of surface area complete all as specified and as directed.
28
-
-
M & L for treating the soil along with external perimeter of building at the rate of 2.25 litres of chemical emulsion in water of one percent Chlorpyrifos 20 EC for per metre of the perimeter wall complete all as specified and as directed.
46
-
-
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
18
-
-
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
65
-
-
Designing, fabricating, manufacturing, transporting, erecting, installing of reinforced solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories for foundation (150 mm thick) in M25 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall including the provision of pipes, fixtures etc. for electricity, plumbing, sewage etc. complete all as specified and as directed. Note: The rate for the provision of pipes, fixtures etc, for electricity, plumbing, sewage shall be measured and paid separately under the relevant items.
90
-
-
Designing, fabricating, manufacturing, transporting, erecting, installing of reinforced solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories for column (250 mm dia) in M25 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall including the provision of pipes, fixtures etc. for electricity, plumbing, sewage etc. complete all as specified and as directed. Note: The rate for the provision of pipes, fixtures etc, for electricity, plumbing, sewage shall be measured and paid separately under the relevant items.
19
-
-
Designing, fabricating, manufacturing, transporting, erecting, installing of reinforced solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories for wall (125 mm thick) in M25 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall including the provision of pipes, fixtures etc. for electricity, plumbing, sewage etc. complete all as specified and as directed. Note: The rate for the provision of pipes, fixtures etc, for electricity, plumbing, sewage shall be measured and paid separately under the relevant items.
347
-
-
Designing, fabricating, manufacturing, transporting, erecting, installing of reinforced solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories for beam (400 mm X 200 mm) in M25 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall including the provision of pipes, fixtures etc. for electricity, plumbing, sewage etc. complete all as specified and as directed. Note: The rate for the provision of pipes, fixtures etc, for electricity, plumbing, sewage shall be measured and paid separately under the relevant items.
25
-
-
Designing, fabricating, manufacturing, transporting, erecting, installing of reinforced solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories for chajja (50 mm thick) in M25 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall including the provision of pipes, fixtures etc. for electricity, plumbing, sewage etc. complete all as specified and as directed. Note: The rate for the provision of pipes, fixtures etc, for electricity, plumbing, sewage shall be measured and paid separately under the relevant items.
8
-
-
Designing, fabricating, manufacturing, transporting, erecting, installing of reinforced solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories for slab (125 mm thick) in M25 (Design Mix) grade concrete as per IS 11447: 1985 and IS 15916: 2020 based on the concept of shear wall including the provision of pipes, fixtures etc. for electricity, plumbing, sewage etc. complete all as specified and as directed. Note: The rate for the provision of pipes, fixtures etc, for electricity, plumbing, sewage shall be measured and paid separately under the relevant items.
280
-
-
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate mixed with water proofing compound as levelling course of roof padding in slope finished even and fair including provision of contraction joint 6 mm wide X 10 mm deep at 1.2 metre interval or part thereof, both ways on top of PCC padding and including filling with mastic bitumen with 85/25 industrial grade bitumen and coarse sand mixture. 1:3 by weight complete all as specified and as directed. Note: - Water proofing compound shall be measured and paid for separately.
10
-
-
M & L for preparing RCC roof surfaces with wire brush drying and cleaning to remove all foreign materials and washing with water to remove loose particle and applying APP membrane HMHDPE 3 kg plain (thickness 2.1 mm) (total weight of the finished membrane not less than 3.0 kg/ sqm ± 5 % per sqm) confirming to IS 16540: 2017 over a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25⁰C, 0.87-0.89 kg/ litre and viscosity 70-160 cps, laying over the primer coat using Butane Torch and sealing all joints, overlapping etc. as per Annex D of IS 16540: 2017 complete all as specified and as directed.
130
-
-
Supply only integral water proofing compound.
120
-
-
S & F reinforced solid precast concrete element in M25 (Design Mix) grade concrete for construction of manhole of size ( 1300 mm (length) X 1300 mm (width) X 1500 mm height) with wall element (minimum 125 mm thick) and base slab (minimum 150 mm thick) and medium duty precast manhole cover including excavations, earthworks, complete all as specified and as directed.
2
-
-
M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete all as specified and as directed.
0.5
-
-
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and fair complete all as specified and as directed.
10
-
-
M & L for precast cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar (1:4) complete with joints to match complete all as specified and as directed.
0.2
-
-
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips and including welding has to be done with minimum 20 cm over lap for new and old of any height. Complete all as specified and as directed.
25
-
-
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.
10
-
-
Material and labour for plastering 15 mm thick on fair faces of brick work or concrete surfaces (on vertical surfaces) in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
1
-
-
Cutting into existing manholes for connecting new drains of pipe of nominal size 150 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate, smooth finished, and reforming benching as required complete all as specified and as directed.
1
-
-
M & L for applying white cement based polymeric putty conforming to IS 17545: 2021, average thickness 2 mm on new, old plastered surfaces, mixed with water in mechanical mixer, applying in one or more coats not exceeding the recommended thickness and keeping the gap/ the interval in subsequent coats, applying on the moistened wall surface uniformly in an upward direction with the help of a putty blade complete as per the manufacturer’s instructions and complete all as specified and as directed.
682
-
-
M & L for prefabricated glass fiber reinforced gypsum beads/ cornices including corners architecturally crafted decorated 100 mm wide and fixing complete all as specified and as directed.
50
-
-
M & L for ceramic fully vitrified tiles as per IS 15622: 2017 and IS 13712: 2019, group B Ia, glazed, polished, rectified, area of each tile exceeding 0.42 sqm but not exceeding 1.0 sqm, length more than 650 mm but less than 1010 mm, minimum 10 mm thick in floors including 15 mm thick screed bed or bedding layer in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
111.38
-
-
M & L for ceramic floor tiles as per IS 15622: 2017 and IS 13712: 2019, group B IIa, anti-skid, glazed, unpolished, rectified, area of each tile exceeding 0.12 sqm but not exceeding 0.22 sqm, length more than 340 mm but less than 460 mm, minimum 8 mm thick in floors including 15 mm thick screed bed or bedding in cement mortar(1:6) set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
27.85
-
-
M & L for ceramic wall tiles as per IS 15622: 2017 and IS 13712: 2019, group B III, glazed, unpolished, rectified, area of each tile exceeding 0.12 sqm but not exceeding 0.22 sqm, length more than 340 mm but less than 460 mm, minimum 7 mm thick on vertical surfaces including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed in epoxy mortar to match complete all as specified and as directed.
62.71
-
-
M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 15 mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
17.17
-
-
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
5
-
-
S & F flush door shutters, 35 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
5
-
-
M & L for plain, solid, straight chowkhats and frames made out of timber species of group I and durability class I as per IS 12896: 1990 and first grade as per IS 4021: 1995, wrought, framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed.
0.26
-
-
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
5
-
-
S & F powder coated, minimum thickness 50 micron, aluminium sections for doors, windows, ventilators, door partition including fabrication of frame, shutters and fixing with necessary lugs, cleats, rollers, handles, locking arrangement etc. including all accessories such as glazings clips, and rubber beadings for fixing glass panes in frame complete all as specified and as directed. Note : (i) Glass panes, wire mesh & handle will be measured & paid separately . (ii)The quoted rate shall be inclusive of cost of rubber beading however it will be not be weighed and not paid separately. (iii) All other minor details including cost of locking arrangement shall be included in the quoted rate.
330
-
-
S & F double action concealed type floor springs (hydraulically regulated) made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel top cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
5
-
-
S & F solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed.
15
-
-
Supply and fix 15 micron coloured aluminium anodised grill design no DG-202, 10 mm thick complete all as specified and as directed. Make : M/S Deco grill or equivalent with & including F sections,
12
-
-
S & F wash basins, vitreous china, colour, oval type, counter top, size 570 mm X 480 X 210 mm fixed on and including granite counter 20 mm thick with and including 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, 32 mm bore brass chromium plated bottle trap including sealing gap between wall and basin with silicone sealant and making good wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
1
-
-
S & F PVC box type mirror cabinet selected quality of size 45 cm X 35 cm X 15 cm thick coloured fixed with min 04 Nos screws fixed on walls complete all as specified and as directed. (Make: Prayag Cat No 557 or equivalent of Make as mentioned under Appendix "B" )
1
-
-
S & F 15 mm nominal size, nonrising spindle type fancy wall mounting combination as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
1
-
-
S & F vitreous china wash down water closet (pedestal pattern), wall mounted type, white including thermoplastic seats and covers of grade 2 type, recessed with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant including necessary masonry/concrete works complete all as specified and as directed.
1
-
-
S & F vitreous china urinals, bowl (flat back) with flushing rim of size 440 mm X 265 mm X 355 mm with side fixing arrangements with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe)complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed.
1
-
-
Supply only 5 litres plastic automatic flushing cistern, including brackets
1
-
-
S & F 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
8
-
-
S & F CPVC pipes for potable hot and cold water distribution, nominal size 15 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 on walls/ ceiling or laying in floors complete all as specified and as directed.
30
-
-
S & F CPVC special transition fittings, elbow with brass threading, 15 mm nominal size complete all as specified and as directed.
5
-
-
S & F CPVC special transition fittings, Tee with brass threading, 15 mm nominal size complete all as specified and as directed.
5
-
-
S & F CPVC pipes for potable hot and cold water distribution, nominal size 25 mm, pressure class 1, SDR 11 including plain CPVC fittings of pressure class 1, SDR 11 on walls/ ceiling or laying in floors complete all as specified and as directed.
35
-
-
S & F CPVC special transition fittings, elbow with brass threading, 25 mm nominal size complete all as specified and as directed.
5
-
-
S & F CPVC special transition fittings, Tee with brass threading, 25 mm nominal size complete all as specified and as directed.
2
-
-
S & F towel rail 600 mm long of PTMT fixed with and including chromium plated brass screw and wooden/plastics cleats, minimum weight 190 gms complete all as specified and as directed.
1
-
-
S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed.
1
-
-
S & F brass, chromium plated toilet paper holder complete all as specified and as directed.
1
-
-
M & L for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
8
-
-
S & F corner sheet glass shelf assembly consisting of 8 mm thick glass sheet shelf, 30 cm wide with chromium plated screwed down for fixing to wall with screws complete all as specified and as directed.
1
-
-
S & F rotational moulded polyethylene double layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
1
-
-
S & F 20 mm gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed to pipe complete all as specified and as directed.
2
-
-
S & F 20 mm nominal size brass float valve, high pressure, with polythene float and flynut, screwed for iron pipe and fixed complete all as specified and as directed.
1
-
-
S & F 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
1
-
-
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 110 mm dia, laid in trenches complete all as specified and as directed.
15
-
-
S & F PVC-U, type B as per IS 13592: 2013 single socketed soil waste pipes in any length with rubber ring joints, 75 mm dia, laid in trenches complete all as specified and as directed.
10
-
-
S & F UPVC bends without inspection door (any angle), 110 mm dia conforming to IS 14735: 1999 complete all as specified and as directed.
12
-
-
S & F UPVC bends without inspection door (any angle), 75 mm dia conforming to IS 14735: 1999 complete all as specified and as directed.
20
-
-
M & L for preparing plastered surfaces of wall treated with any type of putty including chajjas, facias etc. and applying premium acrylic smooth exterior paint (100% acrylic) with silicone additives in two or more coats, that offers an anti-algal, excellent resistance to ultraviolet radiation, dirt pick up resistance (DPUR) property, rich sheen, low VOC, of approved shade over a coat of primer as per the manufacturer’s instructions, applying using brush, keeping the gap/ the interval in subsequent coats, including scaffolding, trestles, ladders, cradles and necessary safety measures complete all as specified and as directed. Note: - The paint shall be as per Apex Ultima of Asian Paints or equivalent of Make mentioned under Appendix "B".
133
-
-
Material and labour for applying two coats of plastic emulsion paint (as per IS 15489: 2024), interior grade type, class-A (matt finish) over and including one coat of primer as per the manufacturer’s instructions on plastered surfaces of wall treated with any type of putty complete all as specified and as directed.
344
-
-
S & F sink made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers & 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to draft wall or including fixing cantilever brackets & connecting union to pipe, overall size 495 mm X 420 mm, bowl size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
1
-
-
S & F sink mixer wall mounted with long arms as per catalogue part No. T1635A1 equivalent of Make as mentioned under Appendix "B" complete all as specified and as directed.
1
-
-
Supplying, fabricating & fixing 18 mm thick single side prelam PVC sheet of density 600 kg per cum, lipped all around exposed surfaces with 0.5 mm thick PVC sheet using bonding tape including fixing with solvent cement adhesive and screws to form cabinet, shelves, wardrobe, drawers and other accessories in modular kitchen cabinet/ cupboard shutters and fixing to wall using rawl plug, to readymade fittings with suitable fasteners complete all as specified and as directed. (Note: All surfaces of cabinet/ cupboard shutters shall be measured for payment.)
10
-
-
S & F thali (plate) basket of size 520 mm X 485 mm X 200 mm made out of stainless-steel sheet (SS 304) as per product code 6168 of Godrej complete all as specified and as directed.
1
-
-
S & F perforated cutlery basket of size 520 mm X 485 mm X 100 mm made out of stainless-steel sheet (SS 304) as per product code 6162 of Godrej complete all as specified and as directed.
1
-
-
S & F three shelf pull out of size 530 mm X 485 mm X 150 mm made out of stainless-steel sheet (SS 304) as per product code 6171 of Godrej complete all as specified and as directed.
1
-
-
S & F self-closing hinge, 75 mm long for kitchen cabinet complete all as specified and as directed.
12
-
-
S & F magnet lock 30 mm long complete all as specified and as directed.
6
-
-
S & F 100 mm long stainless steel (SS 304) fancy type handle complete all as specified and as directed.
6
-
-
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
45
-
-
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
9
-
-
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
8
-
-
M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
5
-
-
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
3
-
-
S & F modular switch, 1 way, 6 A, 1 module complete all as specified and as directed.
61
-
-
S & F modular switch, 1 way, 16 A, 1 module complete all as specified and as directed.
5
-
-
S & F (3 pin and 2 pin) combined modular socket outlets, 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
17
-
-
S & F (3 pin and 3 pin) with common earthing pins, combined modular socket outlets, 6A & 16A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
5
-
-
S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed.
1
-
-
S & F modular bell push, 6A, 1 module, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
1
-
-
S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
15
-
-
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
8
-
-
S & F LED light fittings mirror type with high output diffuser consisting separate batten and tube lights, including both batten and tube lights, 2 feet, 1 X 10 W, 220 V, AC, decorative box type, epoxy powder coated white extruded aluminium channel housing, lumen output of minimum 1000, integral electronic driver (SMPS based constant current output) with output short circuit protection, over voltage protection, surge voltage protection upto 2 kVs, protection grade IP20, CRI greater than 80%, THD less than 10%, power factor of minimum 0.95, life span of minimum 50000 working hours including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
1
-
-
S & F including testing LED batten light fitting 1 X 20 watt with aluminium housing and polycarbonate diffuser complete with integrated LED driver suitable for fixation on wall/roof with robust body, corrosion resistant, flicker control, superior finish. The power factor should be more than 0.95, total harmonic distortion (THD) should be less than 20%, lumen efficacy should not be less than 100 lumens per watt, total input voltage range 140-280V AC, colour rendering Index should not be less than 80, corelated colour temperature should 5000⁰-6500⁰ Kelvin, including dismantling/removing of existing lights complete all as specified and directed. Note: - Rates quoted includes dismantling and nothing will be paid extra on this account.
7
-
-
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
2
-
-
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
1
-
-
S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
8
-
-
S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
2
-
-
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 40 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
1
-
-
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
1
-
-
S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 63 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
2
-
-
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)
35
-
-
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
2
-
-
Supply and fix exhaust fan made of sturdy engineering plastic (having excellent impact and abrasion resistance, light weight and resistance to colour change), complete with louvers shutter, voltage 230V, 50 Hz, speed 1200 rpm, 250 mm sweep size, 5 number of blades, air delivery 860 cubic metre per hour, copper winding complete all as specified and as directed.
1
-
-
S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers complete all as specified and as directed.
1
-
-
Supplying, installing, testing & commissioning, storage water heater (geyser), 25 litres capacity, standing loss less than 0.465 Kwh per day for 45⁰C difference of temperature as per IS 2082 (five-star rated as per BEE), reheating time less than 60 minutes, mixing factor less than 20%, shock proof high density PUF insulation body material, glass lined inner tank material having warranty 7 years on tank material, 4 years on heating element and 2 years on other spares parts comprising following fittings (a) glass coated incoloy element (b) capillary type thermostat (c) digital display unit (d) thermal cutout (e) multifunction valve (f) earth leakage circuit breaker (g) magnesium anode rod cathodic protection (h) flexible cable of suitable length with 3-pin plug of 16A capacity (i) drain plug (j) fusible plug fitted on the crown of water heater with operating temperature between 100⁰C to 110⁰C including fixing by grouting and fastener complete all as specified and as directed.
1
-
-
S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 210 m³ per minute, minimum service value 6 m³ per minute per watt, 3 Nos metal blades protected with corrosion resistance paints, with brushless DC motor having electronic controllers that use sensors, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
8
-
-
Supply, fixing and testing LED Building security light fitting of 25 Watt complete with robust body, corrosion resistant, superior finish, made in a single piece by high pressure die cast aluminium alloy with corrosion resistant polyester powder coated housing including fixing on wall with 1.2 metre long galvanised iron pipe 40 mm or suitable dia medium grade bracket at 120 degree angle with help of suitable GI clamps, nuts, bolts and washers etc complete all as directed. The luminaries shall be monolithic construction totally enclosed dust and waterproof with minimum IP66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 Hz, power factor should be more than 0.95 and Total Harmonic Distortion (THD) less than 10%, corelated colour temperature should 5700⁰-6500⁰ Kelvin. Fitting should be provided with 4 kV surge protection. Driver should have high voltage withstanding capacity upto 300 volt AC. Driver should also have normal phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficacy of LED luminaries system shall be more than 100 lumens per watt. Note for ser Item Nos 5 to 7: - (i) On every fitting CA No. and office name shall be printed by screen printing (min size 20mm x 100mm) and quoted rate shall be deemed to include this factor. (ii) Contractor will arrange its own T&P for any of the schedule work and the rate of the same is deemed to be included in the respective items. (iii) Contractor will provide Certificate from Area Sales manager for purchasing and Genuity of LED Lights. (iv) Contractor will provide safety testing certificate as per IS:10322-2012/2013 all as directed by Engineer-in-charge.
4
-
-
S & F LED panel light recess mounted nominal power 36 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 3600, lumen efficacy of minimum 100 lumens per watt, isolated electronic LED driver (SMPS based constant current supply) with output short circuit protection, over voltage protection, surge voltage protection upto 2 KVs, protection grade IP 20, CRI greater than 80%, beam angle of 110⁰ clear, THD below or less than 10%, CW available CCT of 4000K, power factor of minimum 0.95, CRCA powder coated housing, life span of minimum 50000 working hours as per catalogue No. BZRSQL 36W XL NW Product code 111904 of Bajaj or equivalent of Make mentioned under Appendix "B" complete all as specified and as directed.
8
-
-
S & F sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed.
4
-
-
S & F concealed light fixed in roof round shape 15 W complete all as specified and as directed.
14
-
-
Supplying, installing, testing and commissioning air cooled split unit air conditioner with indoor unit (IDU), outdoor unit (ODU) of capacity 2.0 TR, single phase, input voltage 170 to 270 V AC, 50 Hz, surface / concealed coper Refrigerant piping with insulation (EP Foam pipe section) up to 5 metre (IDU to ODU), copper power cable up to 4 metre, PVC Insulation, FR-LSH copper wire, complete with inverter, twin rotary compressor, cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with BEE 5 star rating complete all as specified and as directed.
2
-
-
Supplying, installing, testing and commissioning air cooled split unit air conditioner with indoor unit (IDU), outdoor unit (ODU) of capacity 1.50 TR, single phase, input voltage 170 to 270 V AC, 50 Hz, surface / concealed coper Refrigerant piping with insulation (EP Foam pipe section) up to 5 metre (IDU to ODU), copper power cable up to 4 metre, PVC Insulation, FR-LSH copper wire, complete with inverter, twin rotary compressor, cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with BEE 5 star rating complete all as specified and as directed.
1
-
-
Supplying, installing, testing and commissioning refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice built-up, automatic adjustment of speed in response to cooling demand, capacity upto 310 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and as directed.
1
-
-
Supplying, laying , jointing, testing and commissioning PVC insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 35 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.
450
-
-
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
32.4
-
-
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.
2667
-
-
Supplying & laying in trenches, in road cutting and along pole 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%