Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date18 Sep 2024
Closing Date17 Dec 2024
Tender Amount₹ 44,50,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the contractor for "ROAD, PATH AND CULVERT" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES

1

-

72353724.44

... More
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES

1

-

2111726.74

... More
Lump sum price worked out by the contractor for "AREA DRAINAGE " as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES

1

-

20132462.4

... More
Lump sum price worked out by the contractor for "FENCING AND GATE" as listed in Schedule ‘A’ Part-VII" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES

1

-

8646604.21

... More
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES

1

-

1525220.22

... More
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES

1

-

10662393.35

... More
Lump sum price worked out by the contractor for "LIGHTENING PROTECTION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES

1

-

154087.4

... More
Lump sum price worked out by the contractor for " SUMMER APPLIANCES " as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES

1

-

3449561.55

... More
Lump sum price worked out by the contractor for "HOT WATER SUPPLY" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES

1

-

1076927.32

... More
Lump sum price worked out by the contractor for " DG SET" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES

1

-

42762.59

... More
Lump sum price worked out by the contractor for "SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK" as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES

1

-

15872489.77

... More
Lump sum price worked out by the contractor for "DEMOLITION WORK" as listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES

1

-

1259079.48

... More
Sch 'A' Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XIV (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule).

-

-

-

... More
INTERNAL ELECTRIFICATION S&F of modular blanking plates 1 Module complete all as specified and directed

86

-

-

... More
S&F of Sheet metal enclosure distribution board VTPN 4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed

3

-

-

... More
S&F of Sheet metal enclosure distribution board VTPN 6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed

2

-

-

... More
Supply and fixing SP 63Amps rating 240V, 10KA 'B' curve rupturing capacity, IS-8828 marked fixing in DBs complete all as specified and directed. Note : (a) Make of the MCB should be the same as that of DB. (b) DBs shall be catered respective items of this schedule

6

-

-

... More
Supply and fixing of MCBs TP 32 Amps, 415V Exinox Metra plug & socket DB's for 3 Phase connection as per IEC 61493-3, suitable for flush mounting and surface mounting suitable for protection of appliances like AC/Geyser etc. suitable with neutral links and win provision for mounting modular devices complete all as specified and directed.

1

-

-

... More
S&F for highbay light 70 watts complete all as specified and directed

41

-

-

... More
S & F for Highly efficient LED Bulbs, 9 watt complete all as specified and directed.

88

-

-

... More
Supply, fixing and testing wall termination telephone socket RJ-11 complete all as specified and directed.

26

-

-

... More
Supply and fixing (Concealed in wall) factory made flameproof DB duly painted, 4 way dust and vermin proof including with all accessories complete all as specifed and directed. (i) MCB 2Pole, 16/25 Amps, 10KA- 01 Nos(incoming) (ii) MCB 1Pole, 6/10 Amps, 10KA- 02 Nos(outcoming)

1

-

-

... More
ROAD PATH AND CULVERT S&F ABS Speed Breaker/Rumbler of height 50mm and width 380mm in two colour of length 500mm each fixed alternately with reflectors on either side complete fixed with epoxy and bolts by drilling 6mmx75mm dia fastener as per manufacture instruction complete all as specified and directed.

160

-

-

... More
S&F convex mirror having 130 degree of viwing angle made of one piece polycarbonate lens size of 0.80 mtr dia protect with any type of light ray not prodice toxic fumes if burnt complete all as specified and directed.

28

-

-

... More
EXTERNAL WATER SUPPLY Supplying, installing, testing and commissioning of centrifugal pumpset with bronze impellor, electrical driven having discharge capacity of 7.5 HP upto 16 metres head, with AC slow speed induction motor of suitable capacity to operate on AC, 3 phase, 415 volts, 50 Hz, with common base plate for electric motor and pump including provision of necessary star delta starter, cable connection from starter to motor with copper conductors complete, each pump set provided with independent suction arrangement consisting of suitable size and length of GI pipes and suitable size of sluice valves with flanged ends, long body, class PN-1 at suction and delivery sides and gun metal stop cock controlled pressure gauge on the delivery side with provision of over load protection no volt release, single phase preventor and armoured PVC cable of suitable size from panel to electric motor complete all as specified and directed. Make : Kirloskar / KSB / Crompton / Jyoti Note : Foot valves and non return valves shall be measured and paid separately

2

-

-

... More
Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 200 mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed. Note: The rate quoted by contractor are inclusive of all type of Joints.

1320

-

-

... More
Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 150 mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed. Note: The rate quoted by contractor are inclusive of all type of Joints.

180

-

-

... More
Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 100 mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed. Note: The rate quoted by contractor are inclusive of all type of Joints.

130

-

-

... More
S&F 250mm dia sluice valves cast iron both ends flanged/spigot and socket ends class PN-1.6 conforming to IS-14846 : 2000 with stainless steel spindle including joints & joining materials (Rubber gasket, nut, bolts, washers etc) complete all as specified and directed.

2

-

-

... More
S&F 63mm bore gun metal globe / gate valve, screwed down high pressure with iron wheel had, screwed both ends for GI pipe including all fittings/fixture complete all as specified and directed.

2

-

-

... More
Supply and Fix ductile iron air valve with two air relese outlets, conforming to IS 14845 of size 200 mm dia bore and fixing up in DI water supply mains complete all as specified and directed

1

-

-

... More
M&L for construction of valve chamber of PCC 1:3:6 masonry built in CM (1:4) with MS covers 3 mm thick and 50 x 50 x 6 mm locking arrangement including excavation and earth works PCC (1:4:8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15mm thick with CM 1:4 painting with one coat of bituminous black paint over a coat of red oxide primer on all steel surface, for the size of chamber 1200 mm x 1200 mm x 1200 mm complete all as specified and directed.

3

-

-

... More
M&L for construction of valve chamber of PCC 1:3:6 masonry built in CM (1:4) with MS covers 3 mm thick and 50 x 50 x 6 mm locking arrangement including excavation and earth works PCC (1:4:8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15mm thick with CM 1:4 painting with one coat of bituminous black paint over a coat of red oxide primer on all steel surface, for the size of chamber 900 mm x 900 mm x 900 mm complete all as specified and directed.

5

-

-

... More
M & L for Cutting of existing 250 mm dia CI/DI pipe line & insert of new 'T' of size 250 x 250 x 200 mm dia including complete earth work joint complete all as specified and directed. Note: The rate quoted by contractor are inclusive of Tee of size 250 x 250 x 200 mm

1

-

-

... More
Supply and fixing bleaching dozer bucket type of capacity 105 ltr complete all as specified and directed

1

-

-

... More
Supply & fixing Foot Valve conforming to IS 4038, of size 100mm dia including complete earth work & joint complete all as specified and directed.

2

-

-

... More
EXTERNAL ELECTRIFICATION Supply, installing, testing and commissioning of 315 KVA 3-Phase Dry Type Compact Sub station out door type, plateform mounted, 11 KV/433 Volts,Air cooled, AC 3 phase, 50 Hz, copper wound, with HT Switch gear (RMU), 02 incomming and 01 outgoing, dry type transformer , LV Switchgear Panel consisting of Incomming MCCB 400 Amp 36 KA FP -01 No,and outgoings MCCB 315 Amp 25 KA 3P - 01No, MCCB 63Amp 25 KA - 03 Nos and MCB DP 20 Amp - 01 and timer 1 phase -01 for street light, Amp meter, Volt meter, Trivector meter along with all interconnection from RMU to Transformer to LT Panel, Earthing arrangment complete all as specified and directed

1

-

-

... More
(a) One cable box on HT side (primary side) consisting ofthree nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out 3 core 185 Sq mm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (b) One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception / taking out 3 1/2 core 400 Sq mm (Two Run), LT 1100 volts grade, PVC / XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers.

-

-

-

... More
(f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device. (g) Two earthing terminals on tank cover to facilitate fixing of 50 x 6 mm galvanised iron earth strip for earthing of body. (h) Rating plate and terminal marking plate. (j) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral. (k) First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 40 KV dielectric strength at 2.5 mm air gap between testing electrodes. (l)  Providing adequate size and nos of channels, embeded in floor, for movement of transformer. Note :- (a) Tranformer shall be energy efficient and be star rated complying with following requirements as under :- (i) Distribution transformer 11KV/433V upto 500 KVA capacity shall be three star rated/marked in accordance with pilot energy labeling scheme. Such mark/label shall be there on the transformer supported by manufacture's declaration/certificate to this effect. (ii) Transformers 11KV/433V, other than being star rated,will have Max losses given as under. The losses of transformers of intermediate rating should also fall in the respective bracket of maximum losses. The manufacturer has to render a certificate with details that heir transfoemer losses at 50% as well as 100% loading doesn't exceed as per IS requirements.

-

-

-

... More
All as per item No 41.01 above but capacity of transformer 400 KVA

1

-

-

... More
Supply, install, test and commissioning of factory made tested LT panel board cubical double door compartment outdoor type Confirming to IS 8623 Part 1 1993, free floor standing/plate mounted made out 3.15 mm thick CRCA sheet and inner compartment 1.6mm CRC sheet & suitable size to accomodate all accessories / fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN having bus bar chamber with insulated Aluminium bus bar of rating not less than 1.5 times the rated cap of incomer ACB/MCCB

1

-

-

... More
The bus bars shall be installed with colour code heat shrinkable sleeve and shall be mounted on DMC/epoxy insulato of size not less than 50 x 50 mm conical type at an interval of not more than 500mm through out the length of the TPN. The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/epoxy insulators having provision for termination off incoming and out going cables. All extension links / interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubical shall have a bottom channel of size 75 x 40 mm. A detachable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands. The above panel shall be front and back openable lockable/openable by key from both side and shall have louvers and air vent gasket for natural flow of air . 3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 2.5 sqmm), including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size complete as specified and consisting the folowing switch gears and accessories (Main Panel Board for 500 KVA Transformer)

-

-

-

... More
(i) Main Incoming ACB Thermal Magnetic Manual Draw out type of rating 1000 Amps, Four Pole 50 KA , 50 Hz, 415 Volts, -1 No (ii) Outgoing MCCB FP 415 Volts 315 Amps 36 kA - 01 No (iii) Outgoing MCCB FP 415 Volt 250 Amps 35 KA - 02 Nos (iv) Outgoing MCCB FP 415 Volt 160 Amps 25 KA - 01 No (v) Outgoing MCCB FP 415 Volt 100 Amps 25 KA - 01 No (vi) Outgoing MCCB FP 415 Volt 63 Amps 25 KA - 01 No (vii) LED type RYB Phase indicator -01 Set(viii) Digital VAFPF meter - 01 no (ix) Heat resistance sleeve (x) TPN Aluminium bus bar with colour code 1500 Amps (xi) Copper wound with CTR 800/5 - 01 Set (xii) Bus bar support Epoxy 50mm (xiii) Brass nut bolt washer 10 x 15mm

-

-

-

... More
(xiv) Sheet metal work including fabrication, PCC foundation etc (xv) Complete wiring with copper cable, thimble etc Spare Compartment - 05 Nos to accommodate switch gear for Phase II Accn Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) The MCCBs shall have spreader links and barriers as standard feature of manufacture. (v) All CTs Shall be as per the rating of the switch gear and Cast resin type (vi) PCC foundation 0.60 mtr hight from GL for mounting of Panel is deemed to be included in the quoted rate for the job.

-

-

-

... More
All as per sl item No 10 here in befor but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 320 Amps 36 kA - 01 No (ii) Outgoing MCCB FP 415 Volts 250 Amps 36 kA - 01 No (iii) Outgoing MCCB FP 415 Volt 100 Amps 36 KA - 01 No (v) Outgoing MCCB FP 415 Volt 32 Amps 10 KA - 01 No (vi) Outgoing MCB DP 240 Volt 25 Amps 10 KA - 02 Nos

1

-

-

... More
All as per sl item No 10 here in befor but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 250 Amps 36 kA - 01 No (ii) Outgoing MCCB FP 415 Volts 100 Amps 36 kA - 03 Nos

2

-

-

... More
All as per sl item No 10 here in befor but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 160 Amps 36 kA - 01 No (ii) Outgoing MCCB FP 415 Volts 63 Amps 36 kA - 02 Nos (iii) Outgoing MCCB FP 415 Volt 32 Amps 25 KA - 02 Nos (iv) Outgoing MCB DP 240 Volt 32 Amps 10 KA - 02 Nos

1

-

-

... More
Supply, install, test and commissioning of factory made tested LT panel board cubical double door compartment outdoor type Confirming to IS 8623 Part 1 1993, free floor standing/plate mounted made out 3.15 mm thick CRCA sheet and inner compartment 1.6mm CRC sheet & suitable size to accomodate all accessories / fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN having bus bar chamber with insulated Aluminium bus bar of rating not less than 1.5 times the rated cap of incomer ACB/MCCB.

1

-

-

... More
The TPN bus bars shall be installed with colour code heat shrinkable sleeve and shall be mounted on DMC/epoxy insulato of size not less than 50 x 50 mm conical type at an interval of not more than 500mm through out the length of the TPN. The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/epoxy having provision for termination off incoming and out going cables. All extension links / interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubical shall have a bottom channel of size 75 x 40 mm. A detachable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands. The above panel shall be front and back openable lockable/openable by key from both side and shall have louvers and air vent gasket for natural flow of air . 3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 2.5 sqmm), including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size complete as specified and consisting the folowing switch gears and accessories (Main Panel Board for 400 KVA Transformer) (i) Main Incoming ACB Thermal Magnetic Manual Draw out type of rating 800 Amps, Four Pole 50 KA , 50 Hz, 415 Volts, -1 No (ii) Outgoing MCCB FP 415 Volts 250 Amps 35 kA - 02 No (iii) Outgoing MCCB FP 415 Volt 200 Amps 35 KA - 03 No (iv) LED type RYB Phase indicator -01 Set (v) Digital VAFPF meter - 01 no (vi) Heat resistance sleeve (vii) TPN Aluminium bus bar with colour code 1500 Amps (viii) Copper wound with CTR 800/5 - 01 Set (ix) Bus bar support Epoxy 50mm (x) Brass nut bolt washer 10 x 15mm

-

-

-

... More
(xi) Sheet metal work including fabrication, PCC foundation etc (xii) Complete wiring with copper cable, thimble etc Spare Compartment - 05 Nos to accommodate switch gear for Phase II Accn Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) The MCCBs shall have spreader links and barriers as standard feature of manufacture. (v) All CTs Shall be as per the rating of the switch gear and Cast resin type (vi) PCC foundation 0.60 mtr hight from GL for mounting of Panel is deemed to be included in the quoted rate for the job.

-

-

-

... More
All as per item No 46 here-in-before but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 160 Amps 35 kA - 01 No (ii) Outgoing MCB SPN 230 Volts 20 Amps 25 kA - 06 Nos

1

-

-

... More
All as per item No 46 here in befor but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 225 Amps 35 kA - 01 No (ii) Outgoing MCCB FP 415 Volts 160 Amps 25 kA - 01 Nos (iii) Outgoing MCCB FP 415 Volt 32 Amps 25 KA - 04 Nos (iv) Outgoing MCCB FP 240 Volt 63 Amps 10 KA - 01 No

1

-

-

... More
Supplying, installation, testing and commissioning of 11 KV, 630 Amps having short circuit capacity 20kA/3-sec, outdoor (IP65 type), RMU (Ring Main Unit) 3-way comprising of 01 Nos manually operated Load Break Switches and 02 Nos 630 Amp Fixed-Type spring-charging VCBs, electrolytic grade copper bus bars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank with minimum thickness 3+0.5 mm, IP 67 Degree of Protection, internal-arc classified 20kA/1sec as per IEC62271-200, on-site-repairable with site replaceable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have pad lockable double-door access with anti-theft hinges, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site.

1

-

-

... More
(A) 01 Nos Incoming Load Break Switches module each consisting of following accessories :- (i) Each switching-unit shall be designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 20kA/3-sec, Making Capacity 50kA - 01 No (iii) Auxiliary contacts 1NO + 1NC - 01 No (iv) Spring-assisted snap-action manual mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch - 01 No (v) Cable terminals (site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 300 Sqmm , 3 Core , XLPE cable termination in live-condition : Each Set of 03 (vi) Right angle boots (push on type) : Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom, front with Interlocking mechanism including earth switch - 01 No (viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It shall be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault - 01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No (B) 02 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch. The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 20kA/3-sec, Making Capacity - 50kAp - 01 No

-

-

-

... More
(iii) Aux. contacts 1NO+1NC - 01 No (iv) Stored-energy manual high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow un-inhibited operation -01 No (v) Cable terminals (site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV, 185 Sqmm, 3 Core, XLPE cable termination in live-condition - Set of 3 (vi) Right angle boots (push on type) - Set of 3 (vii) Associated ring-core cast-resin insulated CTs 50/1 Amp 2.5 VA, 5P10 for protection – Each Set of 3 (vii) O/C + 1E/F self powered numerical protection relay with Low and High set for over current and Earth Fault. Relay shall have the facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping and shall be communicable on MODBUS. (viii) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (ix) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (x) Mechanically latched buttons for breaker On/Off - 01Set

-

-

-

... More
(xi) ON, OFF, TRIP mechanical indication on the front mimic of the panel.(C) Additional equipment delivered separately or mounted separately :- (i) Operating Handle for Manual Isolator/Disconnector/Earthing Operation - 02 Nos (ii) Standard Manometer - 01 No (iii) Operation and Maintenance Manual - 01 No (iv) Installation & Commissioning Manual - 01 No (v) Cable clamping provision (standard) - 01No Note :-(i) It shall be preferable to have all feeder-switches inside single stainless steel compartment with incomer feeders at the extremities to prevent chances of failure due to plug-in coupling arrangement. (ii) Necessary interlocking arrangement shall be provided for safety and operations (iii) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. Any claims towards internal arc compliance, number of mechanical/electrical/short-circuit operations, gas-leakage rates etc. shall not be accepted unless proven via type-test reports of model being offered. (iv) Cost of Provision of Plinth for RMU as per OEM drawing shall be deemed to be included in the cost inserted by the bidders.

-

-

-

... More
S & F cable route indicator of size 100 mm x 100 mm x 5 mm thick GI Plate with insertion there on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and frounting the sae in ground with PCC as required for LT/HT cable incl necessery earth work all as specified and directed.

47

-

-

... More
Supply and fix lithium based energy efficiet integrated solar street light 30 watt in single FRP body encase solar PV panel 53/55 Wp monocrystalline, lithium battery 11.1/12.8V, 28.6AH with inbuilt BMS, high brightness W-LED (180lm/Watt) lamp, CRI70, color temperature 6500K, microcontroller based charge controller cum driver, automatic dimming function with PRI motion sensor, dusk to down operation,LuX output 20-25 (from 8-9 mtr height), working temperature (-) 10 to (+) 55°c weight : 14-16 Kg, with adjustable. MS clamp suitable for pole/wall mounting. protection : short circuit, overload, reverse polarity and battery protections. Firm should produce vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS certified and including necessary civil work and incl GI pipe bracket of suitable dia light grade.

70

-

-

... More
M&L for construction of plate form with PCC Block masonry Masonry platform of size 3m x 3m x 1.2 m hight , PCC(1:3:6) type C1 using 20mm graded stone aggregate built in CM 1:4 complete with and including necessary excavation & earth work , PCC 1:4:8 type D-2 as in foundation , rendering 15 mm thick rendering in CM 1:6 on sides and top of the brick work , upto 300 mm below ground level , supply and fixing of 02 Nos MS Chennels of size MC 100 for balancing of Transformer embedded in PCC (1:2:4) type B-1 , top surface of plateform shall be provided with 100 mm Thick RCC (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 10 mm steel TMT bar , including provn of steps in one side of plateform and all the outer face of platform shall be given with two coat of white wash , including chain link fancing around Transformer plinth size of wire 4 mm dia complete all as specified and directed .

20

-

-

... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed. Note :- GI pipe shall be measured and paid separately.

80

-

-

... More
LIGHTINING PROTECTION M&L for GI pipe of 5 mtr height grouting in PCC type C2 1:3:6 40 mm grade aggregate for fixing of air termination including with socket reducer 40 x 25mm and aluminium gutakha externally threated suitable for socket reducer 25mm and internally threated for air termination rod complete all as specified and directed

4

-

-

... More
SUMMER APPLIANCES Supply and fixing refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice build up, automatic adjustment of speed in response to cooling demand, capacity upto 195 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and directed.

4

-

-

... More
Supply and fixing refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice build up, automatic adjustment of speed in response to cooling demand, capacity upto 310 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and directed.

3

-

-

... More
Supply and Fixing voltage stabilizer for automatic operation single phase naturally air cooled copper bounded, indoor type & designed for input variation between 170 volt to 260 volt with output voltage stabilizer at 230 volt with accuracy of (±) 2.5% and of capacity 3.0 KVA complete all as specified and directed.

10

-

-

... More
Supply and Fixing voltage stabilizer for automatic operation single phase naturally air cooled copper bounded, indoor type & designed for input variation between 170 volt to 260 volt with output voltage stabilizer at 230 volt with accuracy of (±) 2.5% and of capacity 4.0 KVA complete all as specified and directed.

27

-

-

... More
Supply and Fixing voltage stabilizer for automatic operation single phase naturally air cooled copper bounded, indoor type & designed for input variation between 170 volt to 260 volt with output voltage stabilizer at 230 volt with accuracy of (±) 2.5% and of capacity 1.0 KVA complete all as specified and directed.

7

-

-

... More
HOT WATER SUPPLY S&F sheet metal enclosure single pole and neutral with a two pin and earth plug and socket of capacity of MCB 32 Amps complete all as specified

8

-

-

... More
DG SET Supply , install , test and commissioning diesel engine driven silent generating set, 415 volts, 20 kVA 3 phase, 0.8 power factor, 50hz, brushless,1500rpm, self excited, self regulated, AC, and conforming to condition under IS 4722, BS-5514,2613/5000 and adhering to CPCB II norms with control panel complete all as specified and as directed with and including following:(A) ALTERNATOR Standard design alternator rated at 20KVA net putput at site after considering all derating factor, site condition and all power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles,1500 rpm, self excited, self regulated, screen protected, drip proof IP-23 enclosure, brishless design woth hub and sealed ball/roller bearing,wiith winding on each pole face, insulating class H, band of voltage regulation (+- )1% operated voltage from no load to full load and self conforming to BS-2613/BS-5000 and shell B in position to generate supply with frequency regulation with in (+-3) % tolerance, revoling field type, Make: M/S Stamford, M/S Kirloskar electrric, M/S Caterpillar

8

-

-

... More
(B) DIESAL ENGINE Adequate capacity diesel engine suitable to above alternator , water cooled, to drive independently above alternator and after considering deratingas per site condition directly coupled to alternator throught flexible coupling of multicylinder, multistroke, direct injecting, cold starting, 1500 rpm , as per relevant ISI/BS-5514 with an overload cap of 10% for 1 hour in any 12 hours continuous running complete with standard accessories all as specified and required for safe running and operation, salient feature of accessories shall be as under: (i) Flywheel housing (ii) Air cleaner wet/dry type (iii) Fuel Filter (iv) Fuel Injection system including injection pump, solenoid switch, nozzle as per manufacturer's specifications (v) Lubricating oil filter, bypass filter, oil cooler (vi) Lubricating oil pump (vii) Turbocharger (viii) Radiator for water cooling (ix) 12 volts starting system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequates size, initial charging of batteries, battery charger/generator, starter motor, starter gear, start and stop push buttons, ignition key and switch.

-

-

-

... More
(x) Residential type exhaust silencer complete with exchust pipe of suitable dia upto outside the accoustic renclosure, all covered with glass wool wrapped with aluminium foil of 28 SWG adequate to create draft for safe exchaust without transferring vibrations to buildings/walls, flexible exhaust pipe complete. (xi) Microprocessor control electronic metering and module (ECPG) for indication of battery voltage, oil pressure , water pump, engine rmp, hours meter and protection against low oil pressure, high water temperature and over speed of engine including electronic govering . (xii) Battery charging indicator (xiii) Radiator cooling system comprising of radiator, radiator fan belt, water pump with belts , thermostat. (xiv) Fuel hoses (xv) Separate fuel tank made out of 3mm thick CRCP sheet of suitable capacity not less than 500 liters with level indicator, stop cock, drain plug/valve, breath inlet and outlet connections and all fuel supply lines as required at site and as per manufacturers instructions including return and overflow as well as fuel filling arrangement with piping (xvi) Air intake system (xvii) Common base frame of study design suitable for antivibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instrustions (C) CONTROL PANEL control panel shall be indoor cubical type made out of suitable thick CRCA sheet complet factory made dust and vermin proof, totally enclosed with front opening of 415V 3 phase, 4 wire system AC 50Hz,having aluminium busbar of capacity suitable for 110% full load of 16 KW generating set with standard accessories as per manuufacturers instructions

-

-

-

... More
(D) Accoustics insulated enclosure/canopy for Generating set- Accoustic enclosure shall be factory built suitable and conforming to the provisions of environment (protection)second amendment rules 2002 issued vide notification no. GSR371 dated 17 May 2002 at SI NO 94 (Para1&3) (noise limit for warded DG set upto 20kVA type and tested complete (E) 2mm thick Rubber mat of size 1x2m with chequered finish ISI marked suitable for using in electrical installations Make : Premier Polyfins Notes:(a) The capacity of generator set shall be net after all de-rating factory as per relevant design (b) PCC foundation of thickness 150mm bed dimensions as per manufacturers recommendations deemed to be included in the quoted rate

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.