If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_645590_1Bid Award Id
ViewTender No
GE/GUR-/NIT-83/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F 110mm bore PVC(SWR) pipes single socketed in any length pressure rating @6Kg/Sq cm medium Grade laid in floors including all fittings complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
32
-
-
... More
S&F 75mm bore PVC(SWR) pipes single socketed Pressure rating @6Kg/Sq cm medium grade in any length with rubber ring joint, fixed to walls (using MS clamp at every 2mtr) length including taking down eaves, gutters rain water pipes (any size or pattern) including all fittings complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
912
-
-
... More
S&F 75mm bore PVC(SWR) pipes single socketed in any length pressure rating @6Kg/Sq cm medium Grade laid in floors including all fittings complete all as specified and as directed. Notes : The Area includes in this items to working in shaft portion upto 6th storied building.
40
-
-
... More
S&F 110mm bore PVC (SWR) bends any radius With access door complete all as specified and as directed.
48
-
-
... More
S&F110mm PVC (SWR) junction single, (Single T) equal or unequal.with access door complete all as specified and as directed.
288
-
-
... More
S&F 75mm bore PVC (SWR) bends any radius With access door complete all as specified and as directed.
48
-
-
... More
S&F 75mm PVC(SWR) junction single, (Single T) equal or unequal with access door complete all as specified and as directed.
384
-
-
... More
S&F 75mm bore( SWR) vent cowl complete all as specified and as directed.
96
-
-
... More
S&F PVC (SWR) reducers 110mm complete all as specified and as directed.
48
-
-
... More
M&L for demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
9.52
-
-
... More
Excavation in trenches n.exc 1.50 m wide and n.exc 1.50 m in depth for foundation or shafts, wells, cesspits, manholes, pier holes,cable laying, sewage/water lines etc complete and getting out in soft/loose soil complete all as specified and as directed.
542.43
-
-
... More
Demolition and breaking of drain pipes of 150 mm dia (Salt galzed ware, AC or Reinforced concrete set in cement mortar etc complete all as specified and as directed.
128
-
-
... More
M&L for reinforced cement concrete drain pipes of 150 mm dia bore class NP-2, laid and jointed complete with collars etc complete all as specified and as directed.
128
-
-
... More
M&L for concrete bed of thickness 100mm to drain pipes 150 mm bore including packing under and hunching against the sides of pipe, after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregagte) etc complete all as specified and as directed.
128
-
-
... More
Returning filling in including spreading leveling watering and well ramming in layer not exc 25cm thick complete all as specified and as directed.
471.54
-
-
... More
Removal of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.50 mtr above the starting point complete all as specified and as directed.
70.88
-
-
... More
M&L for Cement concrete in filling and mass concrete Type B0 1:2:4(12.5 mm graded aggregate) complete all as specified and as directed.
1.2
-
-
... More
M&L for Cutting into existing manholes for connecting new/existing drains, making good to pipe and rendering , cutting out existing benching for and forming branch channel in cement conc 1:2:4 type B-1 smooth finished and making good benching for 150 mm bore SGSW sewage pipe complete all as specified and as directed.
32
-
-
... More
Dismantling of brickwork or stone boulder masonry, built in cement mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
11.9
-
-
... More
M&L for Brick work with sub class ‘B’ bricks(old size brick), straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:4) and external face of brick work pointed flush in the same mortar as the work proceeds, complete all as specified and as directed.
11.9
-
-
... More
M&L for Rendering 15 mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and as directed.
80
-
-
... More
M&L for preparing newly Plastered surfaces of Walls by applying 1 mm Wall Putty, cutting/rubbing to obtained a Smooth Surface and applying Two Coats of Acrylic Weather Coat Exterior Paint with approved Tint over a coat of Primer (as per Manufacturer's instructions), complete all as specified and as directed.
80
-
-
... More
S&F polycarbonate roofing of thickness 10mm with sides lap fixed with coach screws and washers in roof, walls, MS structure including wind ties wherever required and including taking down existing sheeting complete all as specified and as directed.
225
-
-
... More
M&L for preparing old treated steel surfaces over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
50
-
-
... More
Taking up or down steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches complete all as specified and as directed of sizes :-
-
-
-
... More
(a) 15mm bore.
60
-
-
... More
(b) 20mm bore .
250
-
-
... More
(c) 25mm bore .
80
-
-
... More
(d) 40mm bore .
120
-
-
... More
(e) 50 mm bore .
200
-
-
... More
(f) 80 mm bore .
60
-
-
... More
(g) 100 mm bore .
1100
-
-
... More
S & F in repair steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches complete all as specified and as directed of sizes :-
-
-
-
... More
(a) 15mm bore.
60
-
-
... More
(b) 20mm bore .
250
-
-
... More
(c) 25mm bore .
80
-
-
... More
(d) 40mm bore .
120
-
-
... More
(e) 50 mm bore .
200
-
-
... More
(f) 80 mm bore .
60
-
-
... More
(g) 100 mm bore .
1100
-
-
... More
S & F in replacement Gun metal Gate valve with iron wheel head screwed both ends complete all as specified and as directed of sizes :-
-
-
-
... More
(a) 50 mm dia.
2
-
-
... More
(b) 40 mm dia.
2
-
-
... More
(c) 20 mm dia.
2
-
-
... More
(d) 15 mm dia.
2
-
-
... More
Taking down CI pipe 150 mm bore including connections and all fittings, U/S Lead complete all as specified and as directed.
110
-
-
... More
Supply, Laying and Testing 150mm DI water mains pipes including all fittings with spigot and socket ends and rubber tytan joints Class K9 in any length laid in trenches complete all as specified and as directed.
110
-
-
... More
M&L for CI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction,double branch cross (all sockets or scocket and spigot) collars, Tail piece, caps and plugs upto 150 mm bore CI pipe complete all as specified and as directed.
200
-
-
... More
M&L for boring/auguring (upto 6mtr span) suitable hole and insertion of 50 to 150mm dia pipe not less than 600mm below existing PCC/Road/hard standing complete all as specified and as directed. Note: Pipe will be paid in saperate item.
27
-
-
... More
M&L for PCC 1:3:6 type C2 using (40 mm graded stone aggregate ) for making good distrubed road surfaces and pole foundation including necessary use and waste of form work complete all as specified and as directed.
8
-
-
... More
S&F cast iron flanged drilled heavy duty sluice valve of size 100 mm bore with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion, nuts and bolts with washers etc including taking down old unserviceable sluice valve of size 80 from existing position after removing out nuts/bolts etc complete all as specified and as directed. Note.Nuts and bolts,gasket is included in the unit.
3
-
-
... More
S&F cast iron flanged drilled heavy duty sluice valve of size 150 mm bore with ISI mark with stainless steel spindle and check nut and plan PN-1.6 complete with rubber insertion, nuts and bolts with washers etc including taking down old unserviceable sluice valve of size 80 from existing position after removing out nuts/bolts etc complete all as specified and as directed. Note.Nuts and bolts,gasket is included in the unit.
3
-
-
... More
Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified for the 900mm x 750mm x 900mm size.
6
-
-
... More
Repairs/Maint & Servicing of Automatic operation servo controlled, oil cooled, 3 phase Volage Stabilizer 15 KVA capacity complete all as specified and as directed comprising with the following Works:-
(a) Taking proper shut down in writing/disconnecting up the Incoming and outgoing cable connections and earthing connections from volatge stabilizer and LT panels.
(b) Removing the Volage stabilizer from platform and shifting to suitable place/ building /shed with the help of crane/hydra/Chain pully etc as required at site(Required plant/machiery of any capacity shall be in the scope of contractor).
(c) Drain out transformer oil and storing in suitable container and keep at safe place for refilling. (Container required for serviceable/unserviceable oil received from draing out from voltage stabilizer will be in scope of otractor)
(d) To carry out inspection internally by opening top cover by removing nuts, bolts and washers and all mounting accessories.
(e) Cleaning the tank internally with suitable clothes before refilling the transformer oil.
(f) Refilling the new/serviceable oil after complete repair.
(g) Replacement of worn out parts such as Dimmer coil, transformer, etc including liftting out /lowering down the core (Burnt out/unsv parts paid under respective item of schedule.
(h) Reassembling the same and shifting back to the plateform and connecting all incoming/outgooing cable/earthing connections etc and including testing on load on completion of job complete all as specified and as directed. Note : Any T & P required to faclitate the repair will be in the scope of contractor.
48
-
-
... More
Supply only Volmeter 0-300 V, 72/96 mm complete all as specified and as directed.
8
-
-
... More
Supply only Amp meter 0-1000 A with set of 1000/5A CTs complete all as specified and as directed.
8
-
-
... More
Supply only carbon complete all as specified and as directed.
48
-
-
... More
Supply only Servo circuit PCB complete all as specified and as directed.
5
-
-
... More
Supply only Servo control Panel complete all as specified and as directed.
5
-
-
... More
Supply only Electronic control panel with servo card.(Servo control Box) complete all as specified and as directed.
40
-
-
... More
Supply only Dimmerstate unit 15 amp complete all as specified and as directed.
24
-
-
... More
Supply only servo motor 3 Kg with RC complete all as specified and as directed.
28
-
-
... More
Supply only Main Transformer complete all as specified and as directed.
25
-
-
... More
Dehydration and filteration of voltage stabilizer oil with filtration machine and heating system to get di-electric strength of oil 60 kV minimum complete all as specified and as directed.
48
-
-
... More
Supply only new transformer oil of dielectric strength not be less than 60kV and conforming to IS-335 of 1993 for filling / topping up oil of transformer up to disired level complete all as specified and as directed.
800
-
-
Evaluation Notes How It Works ?