If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 2,08,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Summary
Cwe/af Amb/amb-56/2023-24 Provn Of De-humidifiers At Different Locations At Afs Ambala Under Ge (p) (af) Ambala
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_676608_1Tender No
CWE/AF AMB/AMB-56/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
PROVN OF DE-HUMIDIFIERS AT DIFFERENT LOCATIONS AT AFS AMBALA UNDER GE (P) (AF) AMBALA
PROVN OF DE-HUMIDIFIERS AT DIFFERENT LOCATIONS AT AFS AMBALA UNDER GE (P) (AF) AMBALA
PROVN OF DE-HUMIDIFIERS AT DIFFERENT LOCATIONS AT AFS AMBALA UNDER GE (P) (AF) AMBALA
BOQ Items
Decription all as per BOQ item No. 1.00 here-in-above but capacity 2000 cubic feet per minute @ 550 Pa (20 TR) (WWR Building 4 & 5) Note for BOQ Item No. 1.00 to 4.00: All necessary pipe connection with existing pipe, wall cutting and making good after work and other accessories required for support & fixing of pipe line shall deemed to be included in quoted rates.
1
-
-
Supply, installation, testing & commissioning floor mounted side horizontal discharge Treated Fresh Air Unit of capacity 1000 CFM (P-417 storage 1 & 2) DX type (outdoor application) with rain water protection canopy and TFAU should be mounted on anti-vibration pad. TFAU consist of the following accessories complete all as specified & directed. (i) The panel construction with hollow profile puff insulation panels with inner skin 0.6mm thick GSS and other skin of size 0.6mm thick GSS complete.
(ii) TFAU shall have water tight service door and inspection lamp with limit switch complete.
(iii) The fresh air intake louver with aluminium section powder coated with bird screen constructed from SS material filter section 01, filter should be 5 ply in aluminum mesh, aluminum casing, washable type complete.
(iv) The final filter section (EU-4) having efficiency of 90% down to 10 micron, this section shall be suitable to install above said filter complete.
1
-
-
BOQ Item No. 5.00 contd...../-
(v) DX evaporative coil section consist of the DX evaporative coil shall be suitable for 1000 CFM TFAU. The evaporative coil shall have 4 rows deep coil, the size of the copper coil tube shall be inner grooved of dia 9.5mm and thickness shall be 0.47mm. The aluminum fins having thickness 0.15mm with 12 to 13 Nos. per square inch, the drain pipe material shall be SS-304 and drain pan thickness 18 gauge duly insulated complete.
(vi) The coil configuration having capacity for 5.5 TR/19.2 KW connected to 10 HP VRF ODU capacity or next standard size available as per OEM design.
(vii) The fan section shall be comprise of backward curve DIDW type centrifugal fan, the fan and fan motor and drive set package shall have common base frame with cushy foot mounting or spring isolates.
(viii) The TFAU shall have water tight positive pressure access/service door duly interlocked with fan, TFAU shall heavy thermally insulated totally sealed glass inspection window. The inspection lamp shall be weather proof marine type with limit switch.
(ix) The damper section have low leakage volume control dampers, dampers should have aero foil blade made of aluminium with rubber seal and frame work.
-
-
-
Supply, installation, testing, balancing & commissioning of ducting made out of 24 Guage (MS angle flange) factory fabricated galvanized steel sheet metal (GSS) round / rectangular low pressure ducting, having zinc coating of 120 gram/sqm total on both sides and complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, volume control dampers, hangers, supports, etc. as per approved drawings and conforming to IS 655: 2006 & the latest edition of HVAC Duct Construction Standards - Metal and Flexible of SMACNA along with required scaffolding work to install the ducts at site complete all as specified & directed.
Notes :- (i) The connection of ducts shall be carried out by angle flange technique. (ii) The quoted rates shall be inclusive of hangers & supports, etc. (iii) Volume Control Damper shall be measured & paid separately.
120
-
-
S&F black flexible closed-cell elastomeric thermal insulation 19mm thick (for Supply Air Duct), made of elastomeric foam based on synthetic rubber (NBR / PVC), tested for maximum service temperature 100 ºC as per ASTM C534 & minimum service temperature -50 ºC as per ASTM C534, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 24 ºC as per ASTM C518 / C177, ASTM C335, water absorption by volume ≤ 0.2% as per ASTM C 209 / C1763, flame spread index (FSI) & smoke development index (SDI) 25/50 as per ASTM E84, flammability HB, V-0 as per UL 94, fungi resistance as per ASTM G21/C1338, mould growth resistance as per ASTM E2180-18 / UL 181 and ozone resistance as per ASTM D 1149-18 along with self pre-covered self-adhering, UV treated glass cloth of thickness 7 mm / 200 GSM adhesives and other necessary accessories complete all as specified & directed.
750
-
-
Decription all as per BOQ item No. 7.00 here-in-above but 19mm thick (for Return Air Duct)
600
-
-
M&L 80mm NB MS ERW pipe, Class - C, for chilled water piping including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulated complete all as specified & directed.
20
-
-
Decription all as per BOQ item No. 9.00 here-in-above but 65mm NB MS ERW pipe.
20
-
-
Decription all as per BOQ item No. 9.00 here-in-above but 50mm NB MS ERW pipe.
20
-
-
Decription all as per BOQ item No. 9.00 here-in-above but 40mm NB MS ERW pipe.
20
-
-
Decription all as per BOQ item No. 9.00 here-in-above but 32mm NB MS ERW pipe. Notes for BOQ item No. 9.00 to 13.00 :- (i) The pipe size 150mm NB & below shall be MS 'C' class confirming to IS 1239-(Part-1): 2004 & IS 1239(Part-2): 2011.
(ii) Insulation shall be measured & paid separately.
(iii) All necessary fittings and other accessories shall be deemed included in the quoted rate.
20
-
-
M&L 25mm NB MS ERW pipe, Class - C (confirming to IS 1239 (Part- 1): 2004 & IS 1239 (Part- 2): 2011) drain water piping including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories complete all as specified & directed.
240
-
-
S&F 32 mm thick off-white flexible closed-cell elastomeric thermal insulation for 80mm NB pipe (in tubular form) made of elastomeric foam based on synthetic rubber (NBR / PVC), tested for maximum service temperature 100 ºC as per ASTM C534 & minimum service temperature -50 ºC as per ASTM C534, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 24 ºC as per ASTM C518 / C177, ASTM C335, water absorption by volume ≤ 0.2% as per ASTM C209 / C1763, flame spread index (FSI) & smoke development index (SDI) 25/50 as per ASTM E84, flammability HB, V-0 as per UL 94, fungi resistance as per ASTM G21/C1338, mould growth resistance as per ASTM E2180-18 / UL 181 and ozone resistance as per ASTM D 1149-18 along with self pre-covered self-adhering, UV treated glass cloth of thickness 7 mm / 200 GSM adhesives and other necessary accessories complete all as specified & directed.
20
-
-
Decription all as per BOQ item No. 15.00 here-in-above but thermal insulation for 65mm NB pipe
20
-
-
Decription all as per BOQ item No. 15.00 here-in-above but thermal insulation for 50mm NB pipe
20
-
-
Decription all as per BOQ item No. 15.00 here-in-above but thermal insulation for 40mm NB pipe
20
-
-
Decription all as per BOQ item No. 15.00 here-in-above but thermal insulation for 32mm NB pipe
20
-
-
Supply, installation, testing & commissioning Butterfly valve 80mm NB, wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF8M stainless steel disc, AISI- 304 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125 with necessary accessories complete all as specified & directed.
2
-
-
Decription all as per BOQ item No. 20.00 here-in-above but Butterfly valve 65mm NB.
2
-
-
Decription all as per BOQ item No. 20.00 here-in-above but Butterfly valve 50mm NB.
2
-
-
Decription all as per BOQ item No. 20.00 here-in-above but Butterfly valve 40mm NB.
2
-
-
Supply, installation, testing & commissioning of cast iron bolted cover Y-type strainer 80mm NB with CI body conforming to IS:210 Gr.FG200, SS AISI 304 screen having 1.2 mm perforation, 24 Kg/Sqcm body test pressure & 16 Kg/Sqcm maximum working pressure and standard flange end conforming to BS 10 Table F / Class-150 with necessary accessories complete all as specified & directed.
2
-
-
Decription all as per BOQ item No. 24.00 here-in-above but Y-type strainer 65mm NB.
2
-
-
Decription all as per BOQ item No. 24.00 here-in-above but Y-type strainer 50mm NB.
2
-
-
Decription all as per BOQ item No. 24.00 here-in-above but Y-type strainer 40mm NB.
2
-
-
Decription all as per BOQ item No. 24.00 here-in-above but Y-type strainer 32mm NB.
2
-
-
Supply, installation, testing & commissioning of manual balancing valve 80mm NB, precise balancing, double regulation type brass balancing valve having brass body, brass steam, copper alloy trim, 2.4 MPa body test pressure & 1.6 MPa maximum working pressure and standard screwed female thread ends duly insulated with elastomeric thermal insulation with necessary accessories complete all as specified & directed.
1
-
-
Decription all as per BOQ item No. 29.00 here-in-above but manual balancing valve 65mm NB.
1
-
-
Decription all as per BOQ item No. 29.00 here-in-above but manual balancing valve 50mm NB.
1
-
-
Decription all as per BOQ item No. 29.00 here-in-above but manual balancing valve 40mm NB.
1
-
-
Decription all as per BOQ item No. 29.00 here-in-above but manual balancing valve 32mm NB.
1
-
-
S&F 32mm NB PN 25 rated forged brass ball valve, having lever operated two piece design, renewable P.T.F.E. seat, brass ball, machined brass nickle plated stem, P.T.F.E. packings, full bore port opening, screwed female BSP parallel thread end connections, body test pressure 40 Kg/cm2g Hyd. and working pressure 25 kg/cm2g Hyd. duly insulated with elastomeric thermal insulation with adhesives and other necessary accessories complete all as specified & directed.
2
-
-
S&F 6" dual scale (°F / °C), lower mount (radial), bimetal thermometer having 0.5 NPT process connection, Grade A accuracy class as per ASME B40.200, stem diameter 6.35 mm, laminated safety glass window, stainless steel 304 case, steam, process connection & joint, aluminium dial & pointer, IP67 protection, scale range 0- 60 °C with necessary accessories complete all as specified & directed.
10
-
-
S&F 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar with necessary accessories complete all as specified & directed.
10
-
-
Supply, installation, testing & commissioning of heavy continuous duty industrial grade compressor type flame proof ducted - inline (flange at inlet and outlet) dehumidifier having GI section profile frame, SS/ GIPC single skin heavy grade panel, One touch digital for humidity, temperature and digital sensor for tank overflow. setting & display, inbuilt auto defrost, inbuilt fuse & MCB protection, micro-computer based with inbuilt Compressor auto shut off, O/L for compressor and auto cut-OFF & cut-ON for humidity control & temperature display, +5 to +50 degree centigrade operating temperature, 30% to 90% RH range, R407 Refrigerent, fixed drain tray inside below the coil, capacity 500 LPD for P-774 Building 1, 415 volt, 50Hz, three phase power supply and other accessories, etc. complete all as specified & directed.
SERIES DEW POINT
2
-
-
Decription all as per BOQ item No. 37.00 here-in-above but capacity 400 LPD for P-774 Building 2, P-416, WWR - IV & V, 415 volt, 50Hz, three phase power supply.
4
-
-
Decription all as per BOQ item No. 37.00 here-in-above but capacity 165 LPD for P-417, 230 volt, 50Hz, single phase power supply.
1
-
-
M&L CBRI certified 16-gauge GI fire damper (motorized, spring return type, combination fire and smoke damper), at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated crossovers (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555, the fire dampers shall meet the following under mentioned criteria, complete all as specified & directed. :-
(i) Bare fire dampers with 400mm sleeve.
(ii) Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
(iii) Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers.
(iv) Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer.
6
-
-
Supply, installation, testing & commissioning of commercial air curtain unit size 64" x 90" (for P-774 Building 1) for prevention of dust and conditioned air losses, made out of MS / CRCA sheet of minimum thickness 18 gauge, finished with two coats of red oxide primer and final coat of synthetic enamel paint (oven baked) with MS - CRC 18 gauge square perforated suction grills, aluminium alloy fans, TEFC, high efficiency (IE3), squirrel cage induction motor, conforming to IS 12615: 2018, having BHP rating 20% higher than the peak capacity suitable for 3-Phase, 415 volt ±10%, 50 Hz AC power supply, nozzles etc., complete with fittings, limit switch and accessories so as to produce 1- 1.5 mtr/sec air velocity at floor level complete all as specified & directed.
4
-
-
Decription all as per BOQ item No. 41.00 here-in-above but air curtain unit size 40" x 90" (for P-774 Building 2)
1
-
-
Decription all as per BOQ item No. 41.00 here-in-above but air curtain unit size 64" x 90" (for P-416 Storage 3)
4
-
-
Decription all as per BOQ item No. 41.00 here-in-above but air curtain unit size 64" x 90" (for WWR Building 4)
4
-
-
Decription all as per BOQ item No. 41.00 here-in-above but air curtain unit size 64" x 90" (for WWR Building 5)
4
-
-
Decription all as per BOQ item No. 41.00 here-in-above but air curtain unit size 64" x 90" (for P-417 Storage 1 & 2)
8
-
-
M&L underdeck insulation for RCC roof with bonded fibre glass wool of density 48 Kg/Cum, 75 mm thick, suitably factory laminated with aluminium foil having flange on one side, backed up by scrim and kraft paper, comprising of the following (insulating material shall confirm to BS-476, Part 4,5,6 & 7) complete all as specified & directed.
(a) 50mm x 50mm or 75mm x 75mm slotted angles 50mm wide, fixed to the ceiling by means of rawl plug 600mm centre.
(b) GI tie wire 22 Gauge from vertical slots, for holding the insulating material in position with and including GI washer.
(c) Aluminium foil, adhesive tape 50mm for sealing of aluminium foil flanges. (d) Providing additional support to the insulation with and including chicken wire mesh of size 12.5mm x 0.51mm (24SWG) hexagonal construction, stretched firmly over the insulation
90
-
-
S&F Accoustic lining on wall of AHU Rooms with 50mm thick, 24 Kg/Cum, rigid bonded fibreglass. Accoustic insulation shall be fixed in 610mm frame work made out of 0.6mm thick GI sheet U shaped channel and covers with reinforced fibre glass tissue paper and finished with 0.8mm perforated aluminum sheet including aluminum beading of 25mm wide and 1.00mm thick fixed on all horizontal and vertical joints by means of screws etc. complete all as specified & directed.
480
-
-
Supply, laying & testing PVC sheathed cable galvanised steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 4sqmm, 4 core , 1100 volts grade complete all as specified & directed.
160
-
-
Supply, laying & testing PVC sheathed cable galvanised steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5sqmm, 4 core, 1100 volts grade complete all as specified & directed.
120
-
-
S&F Flame proof - weather proof switch socket & plug combined 16Amp, 500 volt (3P + Earth) complete all as specified & directed.
25
-
-
S&F Flame proof - weather proof switch socket & plug combined 25Amp , 500 volt (3P + Earth) complete all as specified & directed.
7
-
-
S&F Flame proof - weather proof switch socket & plug combined 25Amp , 500 volt (2P + Earth) complete all as specified & directed.
5
-
-
S&F flame proof weather proof MCB DB TPN 415 volts 4 way with bus bar in cast aluminium LM-6 enclosre operated externally spring type knob complete with M-25 cable entry to suit incomming cable and 2 Nos. M-20 cable entries for out going cable from bottom with cable glands suitable for hazardous area and confirming to IS- 2147/62 neoprene gasket degree of protection IP-65 including flame proof MCBs mentioned here-in-under complete all as specified & directed. (a) MCB TPN 63 Amps 10 KA - 01 No. (b) MCB TP 32 Amps 10 KA - 02 Nos. (c) MCB SPN 32 Amps 10 KA -01 No.
12
-
-
M&L flame proof sub main wiring in steel conduit with single core cable (FRLS) PVC insulated sheathed 1100 volt grade copper conductor multistandard 4 run of size 6 sqmm including 2 run of earth wire of 6 sqmm to be drawn in & including enamelled black rigid steel conduit ISI marked including all flame proof conduit accessories such as tee, bend elbow junction box duly tested complete all as specified & directed.
Note: 6 run of conductor and one run of conduit shall be measured as one unit.
120
-
-
M&L flame proof sub main wiring in steel conduit with single core cable (FRLS) PVC insulated sheathed 1100 volt grade copper conductor multistandard 2 run of size 6 sqmm including 1 run of earth wire of 6 sqmm to be drawn in & including enamelled black rigid steel conduit ISI marked including all flame proof conduit accessories such as tee, bend elbow junction box duly tested complete all as specified & directed.
Note: 3 run of conductor and one run of conduit shall be measured as one unit.
120
-
-
M&L flame proof sub main wiring in steel conduit with single core cable (FRLS) PVC insulated sheathed 1100 volt grade copper conductor multistandard 4 run of size 10 sqmm including two run of earth wire of 10 sqmm to be drawn in & including enamelled black rigid steel conduit ISI marked including all flame proof conduit accessories such as tee, bend elbow junction box duly tested complete all as specified & directed.
Note: 6 run of conductor and one run of conduit shall be measured as one unit.
80
-
-
M&L flame proof sub main wiring in steel conduit with single core cable (FRLS) PVC insulated sheathed 1100 volt grade copper conductor multistandard 4 run of size 16 sqmm including two run of earth wire of 16 sqmm to be drawn in & including enamelled black rigid steel conduit ISI marked including all flame proof conduit accessories such as tee, bend elbow junction box duly tested complete all as specified & directed.
Note: 6 run of conductor and one run of conduit shall be measured as one unit.
80
-
-
M&L earthing complete with copper earth plate electrode 600mm x 600mm, 3.15 mm thick electrode and 20mm x 3mm copper strip as earthing lead buried directly in ground earth (earth pit not less 2.25 mtr deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to copper earthing strip 20mm x3mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I, connected to earth test point as specified and testing on completion including provision of 40mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe 1.5 mtr long shall be 20mm bore medium grade including all excavation & earth work in any type of soil including PCC pit (1:3:6) type C-1 with RCC cover including charcoal, salt, funnel, complete all as specified & directed.
Note:- Copper strip beyond 7.5 mtr shall be measured and paid separetely.
16
-
-
S&F copper strip, size 25mm x 3mm with saddles and fixing screws etc. for roof conductors and down conductors above level on the wall and inside the room of AC bldgs to made grid as per user requirement complete all as specified & directed.
50
-
-
M&L test point terminal block made of gun metal & phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screw complete all as specified & directed.
16
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%