Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_663514_1Bid Award Id
ViewTender No
GE/CHM-55/2024-2025Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
40mm thick brick tiles with including 20mm thick cement mortar 1:4 jointed grouted and pointed complete mixed with crude oil 5% by weight of cement complete all as specified and directed.
370
-
-
All as per serial item No 4 herein before but except tiles –ditto-
130
-
-
Raking out joints/ pointing to brick work in walls , on edge in floors, surface channels, roofs, etc complete all as specified and directed.
50
-
-
Flush pointing on bricks laid flat or brick tiles in paving laid flat in cement mortar 1:3 (with water proofing compound)complete all as specified & directed.
NOTE : WPC shall be measured and paid separately
100
-
-
Supply only integral liquid water proofing compound (ISI Marked) complete all as specified & directed.
30
-
-
PCC 1:2:4 type B-0 (12.5 mm graded stone aggs) as in roof padding, roof kerbs rounded or chamfered on edges complete all as specified and directed.
41
-
-
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) ,complete all as specified and as directed.
36.9
-
-
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gms/sqm) laid over a coat of oil bound bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc having 75mm side lap joint and 100m end lap joint after preparing the surface as per standard practice and as per manufacturer instructions and finished complete all as specified & directed.
820
-
-
Applying two coats aluminium paint @100gm/sqm on top of membrane complete all as specified and directed.
250
-
-
Reinforced cement concrete 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in chajjas, parapets, facia etc, all as specified and directed .
4.2
-
-
Mild steel TMT bars 10mm dia and over ,cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
150
-
-
Mild steel TMT bars 6mm to 8mm dia , cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as specified.
20
-
-
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
37
-
-
Brick work with sub class ‘B’ bricks of old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
37
-
-
Cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed.
3.3
-
-
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified.
657
-
-
Dubbing out average 15mm thick on irregular faces of walls, exposed reinforced surfaces, in CM 1:4 complete all as specified and directed.
110
-
-
Rendering 15mm thick (average thickness) plaster in cement mortar 1:4 mixed with WPC on concrete roof surfaces including flashings and junction of parapets etc , finishing the surface even and fair without using extra cement all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid separately as supply only).
820
-
-
15mm thick rendering in Cement and Sand mortar 1:4 over concrete /brick surfaces, in patches, finished even and smooth without using extra cement , providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
460
-
-
10mm thick rendering in Cement and Sand mortar 1:3 concrete surfaces as in ceiling / chajjas facia at any position finished even and smooth in patches without using extra cement including providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
307
-
-
Preparation of new plastered surfaces of walls/ parapets etc and applying two coats of external emulsion weatherproof paint (Acrylic based) over a coat of primer including providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
460
-
-
Preparation of new plastered surfaces of ceiling / chajja etc and applying two coats of external emulsion weatherproof paint (Acrylic based) over a coat of primer including providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
307
-
-
Preparation of old plastered surfaces of walls/ parapets etc and applying one coat of external emulsion weatherproof paint (Acrylic based) over a coat of primer including providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
750
-
-
Preparation of old plastered surfaces of ceiling / chajja etc and applying two coats of external emulsion weatherproof paint (Acrylic based) over a coat of primer including providing necessary scaffolding , safety precautions and other requisite arrangements all as per site requirement complete all as specified & directed.
300
-
-
Preparation of old decorated wall surfaces and applying one coats of oil bound distemper complete all as specified and directed.
500
-
-
Preparation of old decorated wall surfaces and applying two coats of oil bound distemper complete all as specified and directed.
700
-
-
Preparation of old plastered surfaces of walls and applying one coat of cement base paint, complete all as specified and directed.
700
-
-
Preparation of old plastered surfaces of walls and applying Two coats of cement base paint, complete all as specified and directed.
750
-
-
Complete removal of existing treatment of walls/ ceilings/ chajjas/facia/ roof projections in pataches & applying self adhesive water proof texture paint of 100% acrylic latex resin (colour/shade/texture shall be decided by GE) over & including wall care putty as per manufacturer's instruction complete all as specified and directed.
370
-
-
Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frame, glazed with put;ty, or fixed with beads, glazing,f pins/spring clips, complete all as specified and directed.
25
-
-
4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty (or beading) in square n.exc 0.5 Sqm in each panes complete all as specified and directed.
25
-
-
Preparation of old steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
15
-
-
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed
978
-
-
Glazed ceramic tiles in vertical surface 450x 350 x 7mm, joint free, first quality, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
328
-
-
Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed.
325
-
-
Light shade coloured vitrified ceramic tiles 8-10mm thick (square / rectangular) polished, area of each tiles n.exc 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over a 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed
325
-
-
25mm thick Plain cement concrete 1:2:4 type B-0 using 12.5mm graded aggregate as in sub base complete all as specified & directed.
461
-
-
500 Litres capacity Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) double layered hoisted and fixed in position including PTMT ball valve 20mm bore & PTMT tank nipple, etc, fixed as in repairs, complete all as specified and directed.
16
-
-
1000 Litres capacity Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) double layered hoisted and fixed in position including PTMT ball valve 20mm bore & PTMT tank nipple, etc, fixed as in repairs, complete all as specified and directed.
16
-
-
2000 Litres capacity Rotational moulded polythene water storage tanks (cylindrical vertical with closed top) double layered hoisted and fixed in position including PTMT ball valve 20mm bore & PTMT tank nipple, etc, fixed as in repairs, complete all as specified and directed.
5
-
-
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, all as directed.
702
-
-
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as directed.
10
-
-
Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
42
-
-
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
660
-
-
Steel work in tubular trusses and tubular posts including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 , complete all as specified & directed by Engineer-in-Charge.
3700
-
-
Framed work such as grills, gratings, etc with ends of bars shouldered and / or riverted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, raillings, frame work of water tanks and similar work confirming to Fe-290 grade E-165 complete all as specified & directed by Engineer-in-charge.
250
-
-
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide, zinc chrome complete all as specified and directed.
100
-
-
PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed.
210
-
-
110 mm bore PVC (SWR) bends of any radius complete, all as specified and directed.
24
-
-
110mm bore PVC (SWR) branch piece, (double Y) equal or unequal with access door fixed as in repair compelte all as specified and directed.
12
-
-
PVC (SWR) rain water pipe, 75mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed.
150
-
-
75 mm bore PVC (SWR) bends of any radius complete, all as specified and directed.
12
-
-
15 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors , including taking up or down existing GI tubing and removal to store complete all as specified and directed.
30
-
-
20 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors , including taking up or down existing GI tubing and removal to store complete all as specified and directed.
20
-
-