Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 15,00,000Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696935_1Tender No
80886Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lump sum price worked out by the contractor for "ROAD, PATH, CULVERTAND STONE SETT FLOORING" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
1
89082851
-
... More
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
1
5556107
-
... More
Lump sum price worked out by the contractor for "AREA DRAINAGE " as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
1
7228497
-
... More
Lump sum price worked out by the contractor for "FENCING , GATE AND BOUNDARY WALL" as listed in Schedule ‘A’ Part-VII" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
1
9243667
-
... More
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
1
659084
-
... More
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
1
6405753
-
... More
Lump sum price worked out by the contractor for " SUMMER APPLIANCES " as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
1
725224
-
... More
Lump sum price worked out by the contractor for "AIR CONDITIONING" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
1
70599
-
... More
Lump sum price worked out by the contractor for "HOT WATER SUPPLY" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
1
193052
-
... More
Lump sum price worked out by the contractor for "SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
1
45908441
-
... More
Sch 'A' Part-XIV MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XIII (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule).
-
-
-
... More
INTERNAL ELECTRIFICATION
S&F of modular blanking plates 1 Module complete all as specified and directed
102
-
-
... More
S & F for lamp holder including Highly efficient LED Bulbs, 9 watt insulated body with back plate suitable for batten fittings etc complete all as specified and directed.
156
-
-
... More
S&F LED highbay light 70/80 W (or nearest higher Cap), suspended or surface type with very high efficiency in PDC housing suitable for sheds. The luminaries has efficacy 110Lm/W with Ingress protection of IP66 including connecting 3 core copper wire of size 1.5 Sqmm complete all as specified and directed
169
-
-
... More
S & F for LED bed side reading light 5W white/black powder coated housing with movavle string, metalic base complete with driver to oparate 240V AC, 50 HZ suitable for indoor application etc complete all as specified and directed.
118
-
-
... More
S&F of Sheet metal enclosure distribution board VTPN 4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed
3
-
-
... More
S&F in VTPN MCCB 3 Pole, 415 V, 25 to 100Amps , 10KA rupturing capacity IS-8828 marked etc complete all as specified and directed.
2
-
-
... More
S&F in VTPN MCCB 3 Pole, 415 V, 160Amps , 10KA rupturing capacity IS-8828 marked etc complete all as specified and directed.
1
-
-
... More
ROAD, PATH, CULVERTAND STONE SETT FLOORING
M&L for cement Concrete (1:3:6) type C-2, using 40mm graded crushed aggregate in Concrete bed to drain pipes 600mm dia including packing under, and haunching against the sides of pipes after they are laid and tested etc complete all as specified and directed. Note: Qty 781 RM, haunching of 600mm dia pipe shall be executed againt Srl item 25.00 of sewage disposal here-in after
949
-
-
... More
M&L for cement Concrete (1:3:6) type C-2, using 40mm graded crushed aggregate in Concrete bed to drain pipes 450mm dia including packing under, and haunching against the sides of pipes after they are laid and tested etc complete all as specified and directed.
168
-
-
... More
S&F steel fibre reinforced concrete (SFRC) cover anf frame (Heavy duty HD-20 grade designation) 560mm internal diameter confirmoing to IS-12592 total weight of cover and frame shall not be less than 182 kg and to be fixed in Cement Concrete 1:2:4 complete all as specified and directed.
18
-
-
... More
M&L for Cutting into existing manholes for connecting new drains600mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed.
2
-
-
... More
SEWAGE DISPOSAL
Demolition and breaking up drain pipes (salt glazed ware or RCC) set in cement mortar 600mm dia etc complete all as specified and directed.
781
-
-
... More
M&L for cement Concrete (1:3:6) type C-2, using 40mm graded crushed aggregate in Concrete bed to drain pipes 600mm dia including packing under, and haunching against the sides of pipes after they are laid and tested etc complete all as specified and directed.(Qty 781 RM). Note: Haunching of 600mm dia pipe shall be mesured and paid under Srl item 22.00 here in before.
-
-
-
... More
S&F for steel fibre reinforced concrete (SFRC) cover and frame (Heavy duty HD-20 grade designation) 560mm internal dia confirming to IS-12592, total weight of cover and frame not less than 182kgs and to be fixed in cement concrete 1:2:4, type B1 etc complete all as specified and directed.
18
-
-
... More
Cutting into existing manholes for connecting new drains, 600mm bore,making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required etc complete all as specified and directed.
2
-
-
... More
EXTERNAL WATER SUPPLY 'Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.
Note: The rate quoted by contractor are inclusive of all type of Joints.
300
-
-
... More
Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 200mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.
Note: The rate quoted by contractor are inclusive of all type of Joints.
160
-
-
... More
Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.
Note: The rate quoted by contractor are inclusive of all type of Joints.
520
-
-
... More
Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 100mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.
Note: The rate quoted by contractor are inclusive of all type of Joints.
40
-
-
... More
Supply and Fixing DI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed.
400
-
-
... More
S&F 200mm dia sluice valves cast iron both ends flanged/spigot and socket ends class PN-1.0 conforming to IS-14846 : 2000 with stainless steel spindle including joints & joining materials (Rubber gasket, nut, bolts, washers etc) drilled CI gate with brass ring and iron hand wheel and suitable for CI/DI pipe line etc complete all as specified and directed.
2
-
-
... More
S&F 150mm dia sluice valves cast iron both ends flanged/spigot and socket ends class PN-1.0 conforming to IS-14846 : 2000 with stainless steel spindle including joints & joining materials (Rubber gasket, nut, bolts, washers etc) drilled CI gate with brass ring and iron hand wheel and suitable for CI/DI pipe line etc complete all as specified and directed.
4
-
-
... More
S&F 80mm dia sluice valves cast iron both ends flanged/spigot and socket ends class PN-1.0 conforming to IS-14846 : 2000 with stainless steel spindle including joints & joining materials (Rubber gasket, nut, bolts, washers etc) drilled CI gate with brass ring and iron hand wheel and suitable for CI/DI pipe line etc complete all as specified and directed.
2
-
-
... More
Supply & fixing Foot Valve conforming to IS 4038, of size 100mm dia including complete earth work & joint complete all as specified and directed.
2
-
-
... More
Supply and Fix valve, reflex with by pass arrangement 100mm dia etc complete all as specified and directed
1
-
-
... More
Supply and Fix ductile iron air valve with two air relese outlets, conforming to IS 14845 of size 80 mm dia bore and fixing up in DI/CI water supply mains complete all as specified and directed
1
-
-
... More
M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 30x30x4 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering 15mm thick with CM 1:4 painting with two coats of synthetic enamel paint over a coat of red oxide primer for the size of chamber 2000 mm x 2000 mm x 2000 mm (internal dimention) complete all as specified and directed.
1
-
-
... More
M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primer for the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed.
6
-
-
... More
M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primer for the size of chamber 900 mm x 900 mm x 900 mm (internal dimention) complete all as specified and directed.
2
-
-
... More
M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primer for the size of chamber 750 mm x 750mm x 750 mm (internal dimention) complete all as specified and directed.
5
-
-
... More
Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1400 LPM at a head of 50 mtr coupled with 3 phase 415 volt squirel case induction motor of adequate capacity complete with and including following :-
(a) Necessary wiring for interconnection between starter & pump set with 1100 volt rated FRLSH PVC insulated unarmoured cable of minium 10 sqmm three core cable.
(b) Necessary light grade GI pipe protection for cabling from pump set to LT panel.
(c) Bourden pressure gauge.
(d) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.
(e) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.
Note: All other items/material required for fixing pumpset shall be included in cost quoted.
(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. complete all as specified and directed.
2
-
-
... More
Supply, install, commissioning and testing complete of manufacturer or OEM (original Eqpt Manufacture) Manufactured and tested static Diesel Engine driven generating set, radiator cooled with AMF panel capable of delivering 40 KVA (32KW) or nearest higher rating 415 volts AC 3 phase , 4 wire system of supply, 50 Hz . The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternator and mounted on foundation pads on a common base frame in the CPCB approved acoustic enclosure (the complete set confirming to and test certificate as per CPCB norms and as specified ) all as specifed with AMFcontrol panel standardised by manufecture, inbuilt fuel tank , flexible exhaust pipe complete incl necessary PCC foundation as per manufecturer instructruction and shall comprise of the following:-
1
-
-
... More
(a) Engine (Prime mover): Diesel Engine 1500 RPM, of suitable HP as recommended by manufacturer but not less than 58 BHP (AT rated RPM)water cooled ,4 cylinder,inline,4 stroke, confirming to ISO3046/BS 5514 with turbo charged air cooled, 1 x88 AH 12 volts batteries start, mechanical FIP,electronic governor,pulse tuned exhaust manfold,stainless steel exhaust flexible connection complete with flywheel and all standard fitting/ fixtures as per manufecturing practice incl suitable engine control panel with techometer, lub oil temp and pressure guage, water temp starter, dynmo, fuel tank etc
(b) Alternator:- AC alternator, self excited, self regulated, self ventilated, brushless design, confirming to BS 2613/5000,3 phase,415 volts, 4 wire rated line current min 56 amps output at PF 0.8, 1500 RPM, insulation class 'H' enclosure IP 23 complete with AVR with +/- 1% voltage regulation, directly couped to and matched with above engine.
(c) Anti vibration pad for mounting engine alternaor assly on the base frame / plate.
(d) Base Plate: Made out of structural steel as per manufacturer (s) recommended design/specifications.
(e) Acoustic enclosure: Engnine Alternator assy mounted on AV mounts with silencer and SS exhaust bellow suitable optimised to meet stringent noise emmision standards as laid down by MOEF/CPCB. Base rail with drawout type fuel tank provided with drain plug,air vent,inlet and out let connection,level indicator,manhole etc.
(f) 01 Nos 12 volts x 88 AH maint free batteries complete with suitable size copper lead.
(g) AMF Control Panel : RAL-9003 white powder coated control panel manufactured with CRCA sheet provide with MCCB of suitable rating withshort ckt protection, controller which display voltage,current,KW,PF,Frequency,KWH,lube oil pressure etc. display indicating lamps for " Load ON" and "set running",current transformer of suitable rating, aluminium busbar of suitable rating with incomming and out going termination all as manufacturer instruction.
-
-
-
... More
Supply, install commissioning and testing LT panel board (indoor type) cubical type made out of CRCA sheet 2.00 mm thick dust and vermin proof and angle iron of size 35 x 35 x4 mm, pedestal frame grouted in PCC (1:2:4) type B-1 20mm graded stone aggregated thimble and cable entry boxes with cable glands. Panel should be covered from all sides with front and back lockable door and hinges complete with copper busbar of capacity 200 Amps, TPN, three phase, 04 wire (In separate chamber) including painting with two coats synthetic enamelled paint over a coat of red oxide primer and consisting of the following :-
1
-
-
... More
INCOMING:
(a) MCCB 4 Pole 63 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) - 01 No.
OUTGOING:
(b) MCCB 4 Pole 50 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) - 02 Nos (c) Single phase preventor -02 Nos
(d) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No
(e) MCB SPN 10 Amp C curve, 10 KA capacity - 01 No
(f) Provisiion for housing Star-delta starter 25 HP - 02 Nos
(g) Indicator lamp (R,Y,B)
(h) Digital Ammeter 0-100A with suitable ratio of CTs – 01 No.
(j) Digital Volt meter 0-500 Volts – 01 No.
-
-
-
... More
EXTERNAL ELECTRIFICATION
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.
Note :- GI pipe shall be measured and paid separately.
30
-
-
... More
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick SS sheet over MS 40 X 40 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :-
1
-
-
... More
INCOMING:-
(a) MCCB 4 Pole 400 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal release & adjustable magnetic 3.5 to 10.0 In - 01 No (b) Copper Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCCBs - 01 Set.
OUTGOING
(c) MCCB 4 Pole 50 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal setting - 01 Nos (For SM Barrack HQ)
(d) MCCB 4 Pole 40 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal setting - 04 Nos (For SM Barrack 65 ORs 1,2,3, dining hall, pump house)
(e) MCCB 4 Pole 32 amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) with adjustable thermal setting - 05 Nos (For SM Barrack 4, dining hall2,3,4,5)
(e) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 03 Nos for garrage
(f) Street light timer using Power contactor 32 Amps, (1-No), 3 pole, 415Volt, DIN type digital programable time switch 230V AC, Auto/Manual selector switch, MCB TPN, 32 Amps, ON/OFF indicator all prewired and making provision for fixing outgoing cables. - 01 Set (g) Digital Ammeter 0-350 A with selector switch & CTs of suitable capacity - 01 set.
(h) Digital volt meter 0-500 V with selector switch - 01 No.
(i) LED Indicating Lamps R,Y,B - 01 Set
-
-
-
... More
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick SS sheet over MS 40 X 40 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :-
INCOMING:-
(a) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with adjustable thermal release 0.8 to 1.0 & fixed magnetic type - 01 No for incoming.
(b) Copper Busbar 150 Amps duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCCBs - 01 Set.
1
-
-
... More
OUTGOING
(c) MCB TPN 16 Amp 415 V 10 KA- 02 Nos ( For Garrage Feeder piller-3).
(d) Digital Voltmeter 0-500 V with selector switch- 01 No
(e) Digital Ammeter 0-100 A with selector switch & CTs of suitable capacity-01 set
(f) LED Indicating Lamps R,Y,B
(g) Street light timer using Power contactor 32 Amps, (1-NO), 3 pole, 415Volt, DIN type digital programable time switch 230V AC, Auto/Manual selector switch, MCB TPN, 32 Amps, ON/OFF indicator all prewired and making provision for fixing outgoing cables. - 01 Set
-
-
-
... More
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick SS sheet over MS 40 X 40 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :-
1
-
-
... More
INCOMING:-
(a) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with adjustable thermal setting (Optium 2.0) - 01 No for incoming.
(b) Copper Busbar 150 Amps duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCCBs - 01 Set.
OUTGOING
(c) Digital Voltmeter 0-500 V with selector switch- 01 No
(d) Digital Ammeter 0-100 A with selector switch & CTs of suitable capacity-01 set
(e) LED Indicating Lamps R,Y,B - 01 set
(f) Street light timer using Power contactor 32 Amps, (1-NO), 3 pole, 415Volt, DIN type digital programable time switch 230V AC, Auto/Manual selector switch, MCB TPN, 32 Amps, ON/OFF indicator all prewired and making provision for fixing outgoing cables. - 01 Set complete.
-
-
-
... More
Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.0 mm thick SS sheet over MS 40 X 40 x 6 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes all as specified and directed by Engr-in- Charge :-
3
-
-
... More
INCOMING:-
(a) MCCB 4 Pole 16 amps ,415 Volt of breaking capacity not less than 10 KA (Ics=100 % of Icu) with adjustable thermal setting (Optium 2.0) - 01 No for incoming.
(b) Copper Busbar 100 Amps duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCCBs - 01 Set.
OUTGOING
(c) Digital Voltmeter 0-500 V with selector switch- 01 No
(d) Digital Ammeter 0-50 A with selector switch & CTs of suitable capacity-01 set
(e) LED Indicating Lamps R,Y,B - 01 set
-
-
-
... More
Supply and fixing GI pipe bracket of 1.5 m long and made out of 40 mm dia light grade pipe including MS clamp of size 25 x 4 mm - 02 Nos for holding one bracket, nut and bolt with washer duly painted with aluminium paint over one coat of primer of suitable size complete all as specified and diected.
104
-
-
... More
Supply and fixing of energy efficient LED street light fittings of 45 Watts capacity including electric connection, complete fitting including all accessories and following specification and all as directed by Engr-in-charge.
(a) Lumen system efficacy of luminarie should be minimum 100 Lumen per watt.
(b) Input voltage range 140 to 270 volts
(c) Temp operating range minus 10°C to Plus 50°C (d) Power factor : minimum 0.95
104
-
-
... More
(e) THD : Max 10%
(f) CRI : More than 80 and CCT : 5700 K
(g) IP rating : IP66
(h) IK rating : Minimum IK07
(j) Pressure die cast aluminium alloy for housing and heat resistant alear toughened glass (k) Built in potted LED driver of the make as of the luminaire.
(l) LED driver should be complete with all protection viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer.
(m) Surge protection 10 kV (inbuilt + extended)
(n) Lens:- High sfficiency wide angle lens
(o) BIS approved fixtures and driver
(p) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily)
-
-
-
... More
Supply and fixing junction box complete with fixing accessories and following specification and all as directed by Engr-in-charge.
(a) Junction box should be insulated and made out of polycarbonate with glass fiber re-inforced material.
(b) Size Min 210 mm x 155 mm x 92 mm.
(c) IP protection : IP 66 in accordance with IEC 60529.
(d) Internally embedded gasket of plyurethane.
104
-
-
... More
(e) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60670-22, IEC-60670-22, IEC-60670-2 to 5 and color according to RAL 9011.
(f) The manufacture of junction box shall submit a copy of IEC cerfigicate.
(g) Junction box shall be fire retardant and self extigushing in accordance with IEC-60695-2 to 11, DIN VDE 0304 part -3, UL94 V-2 flammability standard. It should be tested at Glove Wire test for 960C.
(h) The degree of protection of enclosure against mechanical load shall be in accordance with E N 50298 for IK08.
(j) Junction box shall be 4 pole complete with single pole MCB 'C' curve of 6 AMP, rating.
-
-
-
... More
M&L for decorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed.
8
-
-
... More
Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5 Sqmm 1100 Volt , draw through LT steel tubular poles for connection to street light from junction box etc complete all as specified & directed.
864
-
-
... More
S&F for Cable route indicator, duly engraved with 'LT CABLE 1100 VOLT' on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed.
74
-
-
... More
M&L for Providing cement concrete type B1 (1:2:4) using 20 mm stone crushed graded aggregate in precast posts for cable route indicator of size 500x300x100 mm rounded top as directed and grouting in ground with PCC (1:3:6) C2 tpye block of size 350mmx150mmx200mm including 10 mm thick plastering all around of exposed surfaces of post above ground with CM (1:4) and applying two coats cement base paint on plastered surface and writing with synthetic enamel paint in black colour in suitable size like HT Cable , complete all as specified and directed by Engr-in-Charge.
8
-
-
... More
Supply and installation of 11 KV 630 KVA compact sub station with consisting of 01 No. manually operated 11 KV, 630 Amps VCB, HT cable/ Bus bar, transformer 630 KVA, 11 KV/433 oil cooled type & associated LT devices (ACB/ MCCB/ Bus Bar/ Cable). All the main components like VCB, Transformer & LT Panel shall be of same make including foundation as manufacturers specification consisting of following items & as per detailed technical specifications:
1
-
-
... More
HV Section
HT 12 KV, 3 phase 50 Hz totally metal clad withdraw able type vaccum circuit Breaker INCOMER CUM OUTGOER (ICOG) panel with Copper bus bar of suitable rating , horizontal isolation type VCB of capacity minimum 630 Amps rated current, as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction with ALUZINC not less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non - loaded bearing and shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25kA/0.1 Sec.
-
-
-
... More
(A) Panel and VCB parameters are as below:-
(i) Rated Voltage level/PF withstand voltage/Impulse level : 12KV/28kV/75 KVP.
(ii) Continuous current rating: minimum 630A.
(iii) Short circuit withstand current : minimum 25 KA for 3 sec.
(iv) One No minimum 630 Amps horizontal draw out type vaccum circuit breaker in 12 KV metal clad floor mouting panel complete with following :-
(a) Manually and motor operated (230V,AC,50Hz) spring charged type, manually and electrically open (electrical - 110VDC ) operation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contact in service position.
(b) manual Charging of breaker should be done without opening the front door.
(c) Cast resin current transformer 11KV,50-25/5,core1: class 1.0,15VA for 3 phase, core2 : 5P10,15VA. (d) Cast resin potential transformer 11KV/V3/110V/V3/110V/3, 50 VA, CI 1.0,CI 3P and HT Fuse at the primary end and 04 pole MCB at the secondary end of the PT (Confirming related IS specification).
-
-
-
... More
(B) Protection arrangements for the breaker shall comprise of the follwing : (i) U/V.O/V,E/F,O/C, S/C with modbus protecol and drawout type- Numerical Type Siemens (Siprotec)/ABB(REF series)/ Schneider (MICOM P 122) (ii) Auxillary transformer protection
(iii) 8 window Annunciator SI800 model
(iv) Power pack with 7 AH Battery along with battery charger for 24 V DC circuit.
(C) The following meters, indications and accessories are to be provided with the panel :
(i) Digital Volmeter range 0-12KV with necessary volmeter with built in selector switch & suitable for 110V AC 96x96 sq mm dia with shrouded terminal.
(ii) Digital Ammeter range of applicable range with necessary ameter with built in selector switch dual graduated scale 96x96 sq mm dia with shrouded terminal.
(iii) Multi-function meter (6400NG/equvalent)
(iv) Necessary DC supply, healthy indication lamp & switch.
(v) Control : (a) TNC (Trip, Neutral & Close) breaker control switch with indicating arrangement, (b) Local/Remote selector switch for breaker open/close operations.
-
-
-
... More
Transformer Section
Transformer 630 KVA, 11/0.433KV, 50 Hz, step down, outdoor type, ONAN Cooled oil immersed copper wound energy efficient transformer, complete with first filling of IS-335 ISI marked filtered & dehyrated tranformer oil and other standard fittings/acceesories and 7 position OFF load circuit tap changer (Tapping range + 7.5% in steps of 2.5% Each) with vector group Dyn-11, with provision of making connection of incomming HT cable and outgoing LT cable Busbar all as per IS 1180-2014 (Level-2) as per Latest IS and complet with and including all required accessories for installation of transformer all as specified and directed. The transformer shall comprises following:
(i) 03 Nos porcelain bushings with copper rod on HV side.
(ii) 04 Nos bushing on LV Side.
(iii) Oil level guage,oil drain filter valve,lifting hucks,oil filling hole with cap/plug with connection plate, Air release valve plug complete.
(iv) 01 Nos 150mm dia, oil temperature indicator with A&T contacts,vapour pressure type having range 0-120 degree with metal guard.
(v) 01 Nos 150mm dia, winding temperature indicator with A&T contacts,vapour pressure type having range 0-120 degree with metal guard.
(vi) 02 Nos earthing terminals on tank cover to facilitate fixing of 50x6mm GI earth strip for earthing of body including rating plate and terminal marking plate. All date shall me marked on Rating plate.
(vii)First fill of unused and new transformer oil,IS-335 Marked filtered and tested upto 60KV die electric strngth at 2.5 mm air gap between testing electrode.
-
-
-
... More
LV Section
INCOMING-
(a) ACB 4 pole 1000 Amp, 50 KA with microprocessor based with O/L, S/C & Earth Fault Protection.
INDICATING PANEL-
(a) Digital multi-functional meter which shows PF, Volts, Amps etc complete.
(b) Aluminium bus bars of suitable capacity, fixed on insulators, coated with PVC sheeves with red, yellow, blue colour.
(c) Phase indicating lamps each backed up with suitable MCB. OUTGOING-
(a) MCCB 4 Pole 400 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with Adjustable Thermal & Magnetic Range (Optium 2.0) - 01 Nos (for Panel-B) (b) MCB TPN 16-25 amps, 10kA, 415 Volt, C series - 01 No(for Religious institute) (c) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) with Adjustable Thermal setting (Optium 2.0) - 01 Nos (for Panel-C). (d) LED Indicator lamp (R,Y,B) - Set of Three.
(e) Digital Ammeter 0-400A with suitable ratio of CTs – 01 No.
(f) Digital Volt meter 0-500 Volts – 01 No.
-
-
-
... More
APFC Panel
Automatic APFC Capacitor bank panel of 200 KVAR. Automatic switching "ON" & "OFF" control panel with dust and vermin proof hinged and lockable door complete with interconnection, bonding to earth (suitable for 400/440 volts, 3 phase 50 Hz supply system). Having Automatic switching with microprocessor based relay ON" & "OFF" control panel for 200 KVAR capacitor in and including fixing Danger plate on both side, interconnection with LT panel with appropriate size of electric cable. Panel consists of following:-
Capacitor Bank:-
25A MCB TP suitable for 12.5 KVAR- 2 Nos
63A MCB TP suitable for 25 KVAR-1 No
100A MCCB TP suitable for 50 KVAR-3Nos
Capacitive duly contactors-
Capacitive-duly contactors suitable for 12.5 KVAR-2Nos
Capacitive-duly contactors suitable for 25 KVAR-1No
Capacitive-duly contactors suitable for 50 KVAR-3Nos
Heavy duty capacitor cylindrical 440V-
12.5 KVAR APP tecnology capacitor bank-2Nos
25 KVAR APP tecnology capacitor bank-1No
50 KVAR APP tecnology capacitor bank-3Nos
6 Sets of illuminated push button stations "RED" & "GREEN" push buttons for manual operation of capacitors.
1 No selector switches for changing automatic to manual operation of capacitors .
-
-
-
... More
Enclosure Section
Outdoor type enclosure having construction of Galvanised Sheet Steel with combination of 1.5/2mm thickness with 4mm HRCA base frame.The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure shall be PU painted/Powder Coated. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. -01Job Note : (i) Drawing of CSS shall be approved by GE before placing order by the contractor.
(ii) All types of spares such as gland, switchgears etc & others items if required shall be included in over all cost quoted.
-
-
-
... More
M&L for construction of plateform of size 2.5m x 3.0m x 0.6 m of Compact Sub Stn with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primer complete all as specified and directed.
1
-
-
... More
M & L for Cutting of existing 250 mm dia CI/DI pipe line & insert of new 'T' of required size including complete earth work joint complete all as specified and directed.
Note: The rate quoted by contractor are inclusive of Tee of required size
2
-
-
... More
SUMMER APPLIANCES
Supply and fixing double door refrigerator electric driven single phase 230 volts, AC 50 Hz,of capacity 400 litre or next available higher capacity with BEE approved, 3 star rating with inbuilt stablizer complete including electric connection etc complete all as specified and directed.
2
-
-
... More
Supply and fixing Desert Cooler of size 26 x 26 x 33 inch or next available higher size having nominal air flow capacity 4000 cubic metre per hour single phase 240 volts 50 hz made out of plain GI sheet 18 SWG & side panels of 22 SWG , and having water storage capacity is min 80 Ltr and having a provision of float valve fixed on directed location and connecting etc complete all as specified and directed.
20
-
-
... More
Supply and fixing Voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variatiion between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of +/- 2.5% of capacity 1 KVA. etc complete all as specified and directed.
10
-
-
... More
Supply and fixing Voltage stablizer for automatic operation single phase naturally air cooled indoor type and designed for input variatiion between 170 volts to 250 volts with output voltage stabilized at 230 volts with accuracy of +/- 2.5% of capacity 2 KVA etc complete all as specified and directed.
2
-
-
... More
AIR CONDITIONING
Supply and fixing air cooled split unit air conditioner inverter type BEE 5 Star rated of capacity 2 Tonne single phase 230 Volt 50 Hz AC indoor & outdoor unit complete with cordless remote & mounted on brackets for outdoor unit including provision of waste water pipe from indoor unit to outside the building etc complete all as specified and directed.
8
-
-
... More
Supply and fixing air cooled split unit air conditioner inverter type BEE 5 Star rated of capacity 1.5 Tonne single phase 230 Volt 50 Hz AC indoor & outdoor unit complete with cordless remote & mounted on brackets for outdoor unit including provision of waste water pipe from indoor unit to outside the building etc complete all as specified and directed.
6
-
-
... More
Supply and fixing Voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized 230 Volt with accuracy of +/- 2.5% of capacity 5 KVA with mounting bracket complete with time delay relay (For ACs) etc complete all as specified and directed.
14
-
-
... More
HOT WATER SUPPLY
Supply and fixing Water heater vertical storage type, BEE approved, 5 star rating, ISI marked, electric driven single phase 230 volts AC 50 Hz of capacity 50 litre complete with vent pipe , fusible plug safety valve etc install at directed location with suitable size MS fasteners with nut, bolts and washers. including connecting inlet and outlet PVC tube connections suitable for hot & cold water supply, commissioning and testing, etc complete all as specified and directed. Note: Outer Tank should be of ABS (Acrylonitrite butadine styrene) material and inner tank should be feroglas coated.
7
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%