Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Services
Electrical and Electronics
Eprocure
Opening Date30 May 2020
Closing Date18 Jun 2020
Tender Amount₹ 11,81,981 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F Blower Motor (as approved) suitable for AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. Make: AMERICAN/UNIVERSAL/BOTLIBOI

2

-

-

... More
S&F Running capacitor 36+6 mfd suitable for AC 1.5 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA

8

-

-

... More
S&F Running capacitor 45+6 mfd suitable for AC 2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA

4

-

-

... More
S&F starting capacitor 80/100 mfd suitable for AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA

4

-

-

... More
S&F Selector Switch suitable for AC 1.5/2.0 Ton Window type of any Make including taking out/ down unserviceable one, complete all as specified and as directed.

2

-

-

... More
S&F Thermostatic Switch with Knob Plate and Screws suitable for AC 1.0/ 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed.

2

-

-

... More
Sealed Compressor Unit suitable for AC 1.5 Ton Window type including brazing of Copper Pipe, cleaning of Refrigerant System of AC, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing including taking out/ down unserviceable Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH Note: (a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate. (b) Transporation Charges shall deem to be included in Quoted Unit Rate. (c) Charging of refrigerant shall be measured separately

2

-

-

... More
Sealed Compressor Unit suitable for AC 2.0 Ton Window type including brazing of Copper Pipe, cleaning of Refrigerant System of AC, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing including taking out/ down unserviceable Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH Note: (a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate. (b) Transporation Charges shall deem to be included in Quoted Unit Rate. (c) Charging of refrigerant shall be measured separately

1

-

-

... More
Taking out Blower Motor from AC 1.5/2.0 Ton Window type, 230 Volt, 50 Cycles, removing burnt Winding Wire, rewinding the Blower Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of insulating materials, binding, varnishing and drying well after varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, testing on load after fixing, complete all as specified and as directed.

2

-

-

... More
Cleaning Gas System with suitable chemical, charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter and Air Filter of AC 1.5/ 2.0 Ton Window type, testing on completion, complete all as specified and as directed.

10

-

-

... More
AIR CONDITIONER (SPLIT TYPE)

-

-

-

... More
Repairing and Maintenance of AC 1.5/2.0 Ton Split type at different location by, Washing and Cleaning Cooling Coil and Condenser along with Fittings First with Air Blower, then with Spraying with coil cleaning chemical of best quality in Coil and Condenser, then Washing with Plain Fresh Water until all Chemicals are removed and Testing, complete all as specified and as directed.

230

-

-

... More
S&F auto Circuit Plate with Remote 220 Volt, 50Hz suitable for AC of any type (Window/Split) including taking out/ down unserviceable one, complete all as specified and as directed.

10

-

-

... More
S&F Blower Fan Blade with Allen Nuts (as approved) suitable for AC 1.5/2.0 Ton Spilt type including taking out/ down unserviceable one, complete all as specified and as directed.

10

-

-

... More
S&F Blower Motor (as approved) suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: AMERICAN/UNIVERSAL/BOTLIBOI

30

-

-

... More
S&F Coil for Outdoor/Indoor Unit suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

2

-

-

... More
S&F Copper Tubing of size 3/8" suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

25

-

-

... More
S&F Copper Tubing of size 5/8" suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

50

-

-

... More
S&F Copper Tubing of size 4/16" suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

50

-

-

... More
S&F Copper Tubing of size 1/2" suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

50

-

-

... More
S&F Insulation Sleeve type of Best quality for Copper Tubing for Suction/ Discharge Pipe any size including taking out/down unserviceable one, complete all as specified.

175

-

-

... More
S&F Plastic PVC Pipe of 25mm bore, ISI mark as Drain Pipe of ACs Split type, fixed to Wall with necessary Clamps, Screws, etc. including taking out/ down unserviceable one, complete all as specified and as directed.

50

-

-

... More
S&F Running capacitor 50+6 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

40

-

-

... More
S&F Running capacitor 36+6 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

50

-

-

... More
S&F Starting capacitor 100/120 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

50

-

-

... More
S&F Starting capacitor 80/100 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

50

-

-

... More
S&F Running capacitor 45+6 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

50

-

-

... More
S&F Running capacitor 6 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

25

-

-

... More
S&F Running capacitor 2.5 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed.

25

-

-

... More
S&F Starting Relay Assembly with Cover & Clip suitable for AC 1.5/ 2.0 Ton capacity, Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: INDFOS/RANUTROL

20

-

-

... More
Sealed Compressor Unit suitable for AC 1.5 Ton Split type including brazing of Copper Pipe, cleaning of Refrigerant System of AC, and Compressor Oil, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and testing on completion including taking out/down unserviceable Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH NOTE :- (a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate. (b) Transporation Charges shall deem to be included in Quoted Unit Rate. (c) Charging of refrigerant shall be measured seperately

25

-

-

... More
Sealed Compressor Unit suitable for AC 2.0 Ton Split type including brazing of Copper Pipe, cleaning of Refrigerant System of AC and Compressor Oil, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion including taking out/ down unserviceable Sealed Compressor and Connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH NOTE :- (a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate. (b) Transporation Charges shall deem to be included in Quoted Unit Rate. (c) Charging of refrigerant shall be measured seperately

20

-

-

... More
Taking out Blower Motor from AC 1.5/2.0 Ton Split type, 230 Volt, 50 Cycles, removing burnt Winding Wire, rewinding the Blower Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of insulating materials, binding, varnishing and drying well after varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, Testing on Load after fixing, complete all as specified and as directed.

15

-

-

... More
Dismantling existing AC 1.5/2.0 Ton Split type including Outdoor and Indoor Unit & reinstallation of Compressor Unit of AC 1.5/2.0 Ton Split type fixing of Air Conditioner on wall with Mild Steel Stand wherever required, providing connection of Copper Pipes of Compressor/Air Conditioner Unit the Pipe connection should be leak proof including necessary brazing of Pipes required, providing proper insulation of Copper Pipes as per requirement Installation of Voltage Stabilizer, making connections of Electric Cable of Compressor with Air Conditioner and further to Voltage Stabilizer and Power Point including Provision of Extra quantity of Flexible Copper Conductor Cable 3 Core 1100 volts of size 40/0.0076 and Top Plug 15 Amp, complete all as specified and as directed. NOTE :- (a) Refilling of gas shall be measured separately.

10

-

-

... More
Cleaning Gas System with suitable chemical, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary of AC 1.5/ 2.0 Ton Split type, Testing on Completion, complete all as specified and as directed.

120

-

-

... More
DESERT COOLER

-

-

-

... More
S&F Fan Leaf of best quality suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed.

90

-

-

... More
S&F Front Grill Double Partition type of 20 SWG, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all Accessories as required including taking out/ down unserviceable one, complete all as specified and as directed.

110

-

-

... More
S&F Motor Kit suitable for Desert Cooler, Copper wounded complete and One Set of Lugs for mounting body including taking out/ down unserviceable one, complete all as specified and as directed. Make: CG/KHAITAN/Blueline

90

-

-

... More
S&F Plastic PVC Distributor suitable for Desert Cooler heavy duty 15mm with Elbow, Tee, etc. fixed with Bolts, Nut & Washers including taking out/down unserviceable one, complete all as specified and as directed.

210

-

-

... More
S&F Plastic PVC Pipe of 15mm bore suitable for Desert Cooler, heavy duty, ISI mark including taking out/down unserviceable one, complete all as specified and as directed.

420

-

-

... More
S&F Running Capacitor 4 mfd suitable for Blower Motor of Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA

70

-

-

... More
S&F Selector Switch suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed.

120

-

-

... More
S&F Submersible Water Pump suitable for Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed. Make: KHAITAN/ORIENT/LITTLE PUMP

180

-

-

... More
S&F Plug Top, 3 Pin, 5/6 Amp including taking out/ down unserviceable one, complete all as specified and as directed. Make: ANCHOR/PLAZA/HAVELLS

180

-

-

... More
S&F PVC Round Flexible 3 Core Copper Connection Lead of size 23/0.0076, including taking out/ down unserviceable one, complete all as specified and as directed. Make: EMPIRE/PLAZA/PRINCE

450

-

-

... More
S&F Mild Steel Desert Cooler Body of 20 SWG Powder Coated with 03 Nos Side Shutters of 22 SWG, Noise Pollution Control complete Body suitable for Air Flow capacity of 5000 Cum of large body including taking out/ down unserviceable one, complete all as specified and as directed. Make: BLUE LINE/CLARION/ELECTROMECH

90

-

-

... More
Taking out Fan Motor from Desert Cooler any size and Make, 230 Volts, 50 Cycles, removing burnt Winding Wire, rewinding the Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of Insulating Materials, binding, Varnishing and drying well after Varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, testing on load after fixing, complete all as specified and as directed.

55

-

-

... More
S&F Wood Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality including taking out/ down unserviceable one, complete all as specified and as directed.

690

-

-

... More
Preparing old surfaces of Desert Cooler Body by descaling, rubbing, brushing, cleaning and applying two coats of Synthetic Enamel Paint (as approved) with Spray Gun Machine and Tank with Black Bituminous Paint from Inside Tank, complete all as specified and as directed.

200

-

-

... More
WATER COOLER

-

-

-

... More
S&F Fan Motor 1/35 HP complete with Blades suitable for Water Cooler of any capacity including taking out/down unserviceable one, complete all as specified and as directed. Make: AMERICAN UNIVERSAL/BOTLIBOI

1

-

-

... More
S&F Over Load Protector with Clips suitable for Water Cooler including taking out/down unserviceable one, complete all as specified and as directed. Mak

3

-

-

... More
S&F Running Capacitor 36 mfd suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA

2

-

-

... More
S&F Running Capacitor 15 mfd suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA

2

-

-

... More
S&F Starting Capacitor 80/100 mfd suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA

2

-

-

... More
S&F Starting Capacitor 40/60 mfd suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA

1

-

-

... More
S&F Starting Relay Assembly with Cover & Clip suitable for Water Cooler of any capacity, including taking out/ down unserviceable one, complete all as specified and as directed. Make: INDFOS/RANUTROL

2

-

-

... More
S&F Self Closing Tap Brass Chromium plated 15mm suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed.

2

-

-

... More
S&F Thermostatic Switch with Knob Plate and Screws suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: INDFOS/RANUTROL

2

-

-

... More
S&F for Sealed Compressor Unit of capacity 1.0 Ton suitable for Water Cooler 40 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Strainer, Capillary, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH

1

-

-

... More
S&F for Sealed Compressor Unit of capacity 1.5 Ton suitable for Water Cooler 150 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Strainer, Capillary, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH

1

-

-

... More
Taking out Blower Motor of Water Cooler of any capacity, 230 Volt, 50 Cycles, removing burnt Winding Wire, rewinding the Blower Motor with Super Enamelled Copper Winding Wire of suitable size and providing Insulation along with insertion of Superior type of Insulating Materials, Binding, Varnishing and Drying well after Varnishing, Replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, Testing on Load after fixing, complete all as specified and as directed.

1

-

-

... More
Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Water Cooler 40 Litre, Testing on Completion, complete all as specified and as directed.

1

-

-

... More
Cleaning Gas System charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Water Cooler 150 Litre 1.0 Ton, Testing on Completion, complete all as specified and as directed.

1

-

-

... More
REFRIGERATOR

-

-

-

... More
S&F Starting Relay Assembly suitable for Refrigerator 170 Litre, including taking out/ down unserviceable one, complete all as specified and as directed.

2

-

-

... More
S&F Starting Relay Assembly suitable for Refrigerator 286/310/315 Litre, including taking out/ down unserviceable one, complete all as specified and as directed.

2

-

-

... More
S&F over load protector suitable for Refrigerator 170 Litre, including taking out/ down unserviceable one, complete all as specified and as directed.

1

-

-

... More
S&F over load protector suitable for Refrigerator 286/310/315 Litre, including taking out/ down unserviceable one, complete all as specified and as directed.

1

-

-

... More
S&F Thermostatic Switch suitable for refrigerator of any description including taking out/ down unserviceable one, complete all as specified and as directed.

2

-

-

... More
S&F for Sealed Compressor suitable for Refrigerator 120 to 170 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. Make: VOLTAS/KELVINATOR/TACEMESH NOTE : Transportation Charges shall deem to be included in Quoted Unit Rate.

1

-

-

... More
Sealed Compressor suitable for Refrigerator 286/310/315 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and Connected Items, complete all as specified and as directed. Make: VOLTAS/KELVINATOR/TACEMESH NOTE : Transportation Charges shall deem to be included in Quoted Unit Rate.

1

-

-

... More
Cleaning Gas System with suitable chemical, charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Refrigerator 120 to 170 Litre, Testing on Completion, complete all as specified and as directed.

2

-

-

... More
Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Refrigerator 286/310/315 Litre, Testing on Completion, complete all as specified and as directed.

1

-

-

... More
DEEP FREEZER

-

-

-

... More
S&F for Sealed Compressor Unit suitable for Deep Freezer 400/500 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and Connected Items, complete all as specified and as directed. Make: Voltas/kelvinator/Tacemesh/Kirloskar/Godrej NOTE : Transportation Charges shall deem to be included in Quoted Unit Rate.

1

-

-

... More
VOLTAGE STABILIZER

-

-

-

... More
Repairing Voltage Stabilizer 4.0/5.0 KVA of any existing make, Replacement of whichever of the following defective Accessories required:- (a) Relays (b) Repair/Rewinding of Transformer with Copper Coil (c) Circuit Plate (d) Digital Volt Meter (e) Indicator and Switches.

8

-

-

... More
Supply, Installation Electronic Voltage Stabilizer for multi-protection Advance Technology with Transformer Single Phase Naturally Air Cooled Indoor type Wall mounted and designed for Input variation 150 Volt to 290 Volt with Output Voltage stabilized at 230 Volt with accuracy of (+) 2.5% and of capacity 4.0 KVA in Repairs, complete all as specified and as directed.

5

-

-

... More
MISC ITEMS

-

-

-

... More
Attending and Rectifying Minor AC's/Cooling Appliances Complaints (on Daily Basis) within 24 HOURS in DOMESTIC/TECH AREA at AF STATION SIRSA, complete all as specified and directed. NOTE : Mechanic will be well qualified and equipped with all T&P required for rectifying the AC's/Cooling Appliances Complaints.

500

-

-

... More
S&F Connection Lead 3 Core, PVC insulated and sheathed Copper Cable size 2.5sqm including taking out/ down unserviceable one, complete all as specified and as directed.

20

-

-

... More
S&F MCB 32 Amp, Single Pole, 220 Volt, 50 Hz, suitable for split AC 1.5/2.0 Ton with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCB, complete all as specified and as directed.

20

-

-

... More
S&F 20 Amp metal socket with earth for AC box including taking out/ down unserviceable one, complete all as specified and as directed.

10

-

-

... More
S&F 20 Amp metal plug with earth for AC box including taking out/ down unserviceable one, complete all as specified and as directed.

10

-

-

... More
S&F 20 Amp AC box with metal plug and socket without MCB including taking out/ down unserviceable one, complete all as specified and as directed.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.