Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Jan 2025
Closing Date29 Jan 2025
Tender Amount₹ 39,40,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as specified and directed by Engr-in-Charge. Note:- Compacted / punned thickness of sand shall be measured and paid to the contractor.

105

-

-

... More
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete as sepecified and directed by Engr-in-Charge.

11250

-

-

... More
M&L for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of pipe for protection of cable etc by means of mannual bookle and without disturbing the top surface and making good the disturbed surface if any complete as sepecified and directed by Engr-in-Charge.

150

-

-

... More
Supply and laying GI tube medium grade 80 mm bore, ISI marked complete all as specified and directed by Engr-in-Charge.

80

-

-

... More
Supply and laying GI tube medium grade 40 mm bore, ISI marked complete all as specified and directed by Engr-in-Charge.

70

-

-

... More
M&L for detecting of fault in 1100 Volt cable of any size upto 400 Sqmm 3.5 core laid in trench fault locating machine comprising of surg generator pulse,ECHO fault locator with high frequency distance calculator etc and exposing the cable fault,removal of deteriated portion of cable , treating of cable and making the same ready for jointing work complete all as specified and directed by Engr-In-Charge. Note-(1) The area of this contract is very critical for safety reason so as to contractor has to arrange 24X7 hours fault locating machine and jointing kit when fault occurs and when denied by the contractor, double of quoted rate as panelty will be imposed by Engineer-in-Charge .

42

-

-

... More
Taking out old serviceable /unserviceable under ground cable of following sizes from trenches/poles /pipe/floor complete all as specified and as directed:-

-

-

-

... More
16 Sqmm 3.5 core to 35 Sqmm 3.5 core

550

-

-

... More
50 Sqmm 3.5 core to 120sqmm 3.5 core

980

-

-

... More
185 Sqmm 3.5 core to 400 sqmm 3.5 core

320

-

-

... More
Supplying , laying, passing through pipe , connecting and testing in replacement of UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts, cross sectional area 16 Sqmm, 4 Core complete all as specified and as directed by Engr-in-charge (Note:- Excavation & earthwork etc shall be measured and paid sepretaly under respective item, of schedule):-

150

-

-

... More
All as per item No 11.00 described here-in-before but of size 25 Sqmm, 3½ Core .

230

-

-

... More
All as per item No 11.00 described here-in-before but of size 35 Sqmm, 3½ Core .

170

-

-

... More
All as per item No 11.00 described here-in-before but of size 50 Sqmm, 3½ Core .

250

-

-

... More
All as per item No 11.00 described here-in-before but of size 70 Sqmm, 3½ Core .

260

-

-

... More
All as per item No 11.00 described here-in-before but of size 95 Sqmm, 3½ Core .

350

-

-

... More
All as per item No 11.00 described here-in-before but of size 120 Sqmm, 3½ Core .

120

-

-

... More
All as per item No 11.00 described here-in-before but of size 185 Sqmm, 3½ Core .

80

-

-

... More
All as per item No 11.00 described here-in-before but of size 240 Sqmm, 3½ Core .

120

-

-

... More
All as per item No 11.00 described here-in-before but of size 400 Sqmm, 3½ Core .

120

-

-

... More
M&L in repair for cold shrinkable jointing kit including suitable size of connector complete all as per directed by Engr-in-charge. Note : Cost of necessary excavation and earth work (by hydra machine or manual which suits), labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location shall be deemed to include in quoted rates) for the following sizes :- Note- This item also includes charges for exacavation in concrete/pitched road (by hydra) in case fault occurs in the cable below the road.

-

-

-

... More
XLPE Cable of size 16 sqmm to 50 Sqmm x 3.5/4 core

32

-

-

... More
XLPE Cable of size 70 sqmm to 120 Sqmm x 3.5/4 core

25

-

-

... More
XLPE Cable of size 185 sqmm to 240 Sqmm x 3.5/4 core

18

-

-

... More
XLPE Cable of size 300 sqmm to 400Sqmm x 3.5 core

17

-

-

... More
Supply and fixing in replacement of aluminium thimble , cable gland and lugs after disconnecting from panel and taking down burnt cable from panel of different location and cutting out the burnt portion of cable and extending the cable from cable loop, preparation of cable including necessary connection and testing complete (Note : (i) 01 Job consisting of 04 Nos Lugs/thimble at one end of cable (ii) Rate of necessary earth work for opening of loop if requried at site are deemed to be included in the quoted rate.) of following sizes :-

-

-

-

... More
25 Sqmm 3.5 core 1100 volt grade

45

-

-

... More
35 Sqmm 3.5 core 1100 volt grade

45

-

-

... More
50 Sqmm 3.5 core 1100 volt grade

45

-

-

... More
95 Sqmm 3.5 core 1100 volt grade

45

-

-

... More
120 Sqmm 3.5 core 1100 volt grade

45

-

-

... More
240 Sqmm 3.5 core 1100 volt grade

45

-

-

... More
300 Sqmm 3.5 core 1100 volt grade

45

-

-

... More
400 Sqmm 3.5 core 1100 volt grade

45

-

-

... More
S&F in replacement LT volt meter (0-500) digital square flush type of size 96x96 mm including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable Volt meter complete as specified and directed by Engr-in-Charge.

9

-

-

... More
S&F in replacement 1100 Volts grade LT Ammeter (0 - 300 A) digital square flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete as specified and directed by Engr-in-Charge.

6

-

-

... More
S&F in replacement 1100 Volts grade LT Ammeter (0 - 500 A) digital square flush & CT type with CT's including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable Ammeter complete as specified and directed by Engr-in-Charge.

4

-

-

... More
M&L for Spray painting to LT panel board with synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces. complete as specified and directed by Engr-in-Charge.

25

-

-

... More
S&F in replacement of MCCBs 415 volts 50Hz thermal and fixed magnetic setting release including necessery fixing arrangement & testing complete as specified and directed by Engr-in-Charge of following sizes:-

-

-

-

... More
100 Amps 4 Pole breaking capacity 35/36 KA .

4

-

-

... More
125 Amps 3 Pole breaking capacity 35/36 KA .

4

-

-

... More
160 Amps 4 Pole breaking capacity 35/36 KA .

8

-

-

... More
160 Amps 3 Pole breaking capacity 35/36 KA .

3

-

-

... More
200 Amps 4 Pole breaking capacity 36 KA .

8

-

-

... More
200 Amps 3 Pole breaking capacity 36 KA .

4

-

-

... More
250 Amps 4 Pole breaking capacity 36 KA .

8

-

-

... More
250 Amps 3 Pole breaking capacity 36 KA .

2

-

-

... More
400 Amps 4 Pole breaking capacity 36 KA ..

3

-

-

... More
400 Amps 3 Pole breaking capacity 36 KA .

3

-

-

... More
630 Amps 4 Pole breaking capacity 50 KA .

3

-

-

... More
630 Amps 3 Pole breaking capacity 50 KA .

2

-

-

... More
Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size including bus bar ,ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as directed.

2

-

-

... More
Supply, install, commissioning and testing of LT panel board double door outdoor type floor mounted of factory made powder coated made out of outside body of 3.15mm thick steel sheet and inside body 14 gauge steel sheet, locking arrangement, front side and rear side opening arrangement of suitable size, Incl mounted on Angle iron stand of size 50x50x6mm having minimum height 1.5 feet duly grouted or welded on floor. Aluminium bus bar TPN of 800 A for MCCB to all feeders to accommodate following items:- The Quoted price of this Panel will also include following items and should accomodate in this panel: - (a) Incoming MCCB 630 Amp 35/36 KA 4pole-01 No. (b)Outgoing MCCB 400 amp 35/36 KA 4pole -01 No.(c) Outgoing MCCB 250 amp 35/36 KA 4pole -01 No. (c) Outgoing MCCB 100 amp 35/36 KA 4pole -01 No. (d) RYB indicating lamp for each incoming & outgoing supplies-1set (e) Voltmeter, amp meter, with CT’s & selector switch-01 set. (f) Termination of all cables with suitable size thimble and gland-1job and all auxillary items required Note- This item also includes separate Steel Roof with four leg for panel whose leg should be grouted with RCC . Note- The panel should be installed on PCC plinth of height 1.5 feet above ground level and and base should be proper depth and the making of plinth amount included in this item.

1

-

-

... More
Supply, install, commissioning and testing of LT panel board double door outdoor type floor mounted of factory made powder coated made out of outside body of 3.15mm thick steel sheet and inside body 14 gauge steel sheet, locking arrangement, front side and rear side opening arrangement of suitable size, Incl mounted on Angle iron stand of size 50x50x6mm having minimum height 1.5 feet duly grouted or welded on floor. Aluminium bus bar TPN of 400A for MCCB to all feeders to accommodate following items:- Make -L& T/Universal Switch Gear/CG. The Quoted price of this Panel will also include following items and should accomodate in this panel: - (a) Incoming MCCB 630 Amp 35/36 KA 4pole-01 No. (b) Outgoing MCCB 100 amp 35/36 KA 4pole -03 No. and MCCB 100 amp 35/36 KA 4pole -02 No. (c) RYB indicating lamp for each incoming & outgoing supplies-1set (d) Voltmeter, amp meter, with CT’s & selector switch-01 set. (e) Termination of all cables with suitable size thimble and gland-1job Note- This item also includes separate Steel Roof for panel whose leg should be grouted with RCC . Note- The panel should be installed on PCC plinth of height 1.5 feet above ground level and and base should be proper depth and the making of plinth amount included in this item.

1

-

-

... More
M&L for preparation of old painted surface of electric RCC pole by removing all dirt, dust etc and apply approved colour one coat of synthetic enamel weather resistant paint upto 1.5 mtr height (Five layer 30 cm Blue and 30 cm White one over another) and one coat of synthetic enamel paint on steel surface such as cross arm including writing of identification No , etc complete all as specified and directed.

40

-

-

... More
All as per item No 31 herein before but one coat of aluminium paint on steel tubular pol -ditto-.

200

-

-

... More
Supply and fixing in replacement of stay assembly complete with 16mm dia stay Rod including PCC 1:3:6 type C-2 complete all as specified and as directed by Engr-in-charge. (Note:- Excavation and earth work measured and paid seperately).

8

-

-

... More
S&F danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters,figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts and nuts of approved siz,for LT ,20X15 cm size complete all as specified and as directed.

18

-

-

... More
M&L for surface dressing and proper laying of XLPE electrical cable of any size and capacity nearby the LT Panel after disconnecting all incoming and outgoing connection complete including cleaning of grass nearby the LT Panel upto 2mtr all around , necessary earthwork as required all as specified and as directed by Engr-in-charge. (Note : Rate of necessary earthwork as required at site are deemed to be included in the quoted rate)

15

-

-

... More
Supply, laying/fixing, jointing and testing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connection of size 10 Sqmm 2 core single stranded as in repair complete as specified and directed by Engr-in-Charge.

220

-

-

... More
Supply, laying/fixing, jointing and testing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connection of size 16 Sqmm 2 core single stranded as in repair complete as specified and directed by Engr-in-Charge.

420

-

-

... More
Supply and laying in repair Synthetic insulating mat of size 2Mx1Mx10mm thick ISI marked complete as specified and directed by Engr-in-Charge.

6

-

-

... More
Supply and laying in repair synthetic insulating mat of size 2Mx1Mx12mm thick ISI marked complete as specified and directed by Engr-in-Charge.

4

-

-

... More
S&F in replacement for Side handle main switch of capacity 200 Amps , 415 Volts , 3 pole with sheet metal inclosure complete all as specified and directed by Engr-in-charge.

4

-

-

... More
S&F in replacement for Changeover switch of capacity 250 Amps , 415 Volts , 4 pole with sheet metal inclosure complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in replacement for Changeover switch of capacity 400 Amps , 415 Volts with sheet metal inclosure complete all as specified and directed by Engr-in-charge.

4

-

-

... More
S&F in replacement for Changeover switch of capacity 630 Amps , 415 Volts , 4 pole with sheet metal inclosure complete all as specified and directed by Engr-in-charge.

3

-

-

... More
S&F in replacement for Changeover switch of capacity 100 Amps , 415 Volts, 4 pole with sheet metal inclosure complete all as specified and directed by Engr-in-charge.

4

-

-

... More
Maintanance of installation including cleaning grass vegitations, trimming of trees and garden maintanance of installation complete all as directed.

60

-

-

... More
Supply and spary Grass herbicide with the help of kishan sprayer for cleaning the grass of Substation and other installations in AFSSR complete all as directed.

30

-

-

... More
Repair and maintenance of PV Module 300 WP and higher wattage PV module for 50 KW (with bipassdiode and connectors) complete 50 KW solar system any make. This item includes repair of solar control panel and solar plate and replacement of wiring, cable from plate to panel and all accessories for making the solar servicable in all respect and all cost incured in the quoted rate. Note- (i) Contractor should visit the site before quoting. (ii) Contractor has to provide a completion certificate after completion of 11 month period from user duly signed by AGE E/M for this item only. This item covers the comprehensive maintenance of a Solar Photovoltaic (SP) Plant. The contractor shall ensure smooth operation, regular cleaning, preventive maintenance, and prompt rectification of any faults to achieve optimum performance and efficiency.

11

-

-

... More
2. Scope of Work 2.1. Cleaning Services 1. Solar Panels: • Cleaning all solar PV modules at least twice a month or as required to maintain efficiency. • Use of soft brushes, water jets, and approved cleaning agents to prevent damage to the module surface. • Ensure no water stagnates on panels post-cleaning. 2. Surrounding Areas: • Keep the area around the plant clean, ensuring no dust, debris, or vegetation hampers panel performance or safety.

-

-

-

... More
2.2. Preventive Maintenance 1. Solar Panels: • Visual inspection of panels for cracks, discoloration, or damage. • Verification of proper mounting and alignment of modules. 2. Inverters: • Cleaning and inspection of inverters for proper operation. • Checking cable terminations, earthing, and performance logs. 3. Cabling and Connections: • Checking all DC and AC cables for insulation issues, loose connections, or damage. • Ensuring proper cable routing and securing with clamps or ties. 4. Monitoring Systems: • Inspect SCADA or data loggers for proper functioning and accurate reporting. • Calibrate sensors (if applicable). 5. Structures and Mountings: • Checking mounting structures for corrosion, loosened bolts, or alignment issues. 6. Battery Banks (if any): • Inspection of batteries for electrolyte levels, connections, and overall health.

-

-

-

... More
2.3. Breakdown Maintenance: 1. Respond to any faults within 24 hours of reporting. 2. Rectify issues related to: • Panel damage or inefficiency. • Inverter or electrical faults. • Cabling faults or loose terminations. 3. Replace defective parts (spare parts supplied by the owner or contractor as per contract terms). 2.4. Reports and Documentation 1. Submission of monthly O&M reports detailing: • Cleaning schedules and activities completed. • Performance data (energy generated, plant efficiency, and downtime). • Maintenance activities conducted. 2. Immediate reporting of faults, along with root cause analysis and corrective measures. 3. Maintaining an on-site logbook for all maintenance and operational activities. 3. Contractor’s Responsibilities 1. Deploy trained manpower to carry out maintenance activities. 2. Provide all necessary tools, equipment, and consumables for maintenance and cleaning. 3. Ensure adherence to safety standards and guidelines. 4. Provide insurance coverage for their personnel. 5. Use only approved cleaning agents and tools that do not harm the solar modules or components.

-

-

-

... More
4. Performance Standards 1. Ensure at least 98% plant availability during the contract period. 2. Maintain performance ratio (PR) above the agreed threshold (typically 75-80%). 3. Prevent downtime due to negligence in maintenance or delays in fault resolution. 5. Exclusions • Replacement of major parts (panels, inverters, transformer) unless otherwise agreed. • Force majeure events like natural calamities or vandalism. 6. Payment Terms 1. Payment to be made on a monthly basis upon submission of: • Monthly O&M report. • Invoice and certification of work by the site in-charge. 2. Deductions may apply if performance standards or scope of work is not met. 7. Safety and Compliance 1. Follow all applicable safety protocols while working on the plant. 2. Ensure compliance with electrical safety standards and regulations. 8. Penalty per day for failure to respond to faults within the agreed time. • Penalty of Rs. 1000 for failure to meet cleaning schedules.

-

-

-

... More
Repair and maintenance of PV Module 300 WP and higher wattage PV module for 70 KW (with bipassdiode and connectors) complete 70 KW solar system any make. This item includes repair of solar control panel and solar plate and replacement of wiring, cable from plate to panel and all accessories for making the solar servicable in all respect and all cost incured in the quoted rate. Note- (i) Contractor should visit the site before quoting. (ii) Contractor has to provide a completion certificate after completion of 11 month period from user duly signed by AGE E/M for this item only. 1. General Description:- This contract covers the comprehensive maintenance of a Solar Photovoltaic (SP) Plant. The contractor shall ensure smooth operation, regular cleaning, preventive maintenance, and prompt rectification of any faults to achieve optimum performance and efficiency.

11

-

-

... More
2. Scope of Work 2.1. Cleaning Services 1. Solar Panels: • Cleaning all solar PV modules at least twice a month or as required to maintain efficiency. • Use of soft brushes, water jets, and approved cleaning agents to prevent damage to the module surface. • Ensure no water stagnates on panels post-cleaning. 2. Surrounding Areas: • Keep the area around the plant clean, ensuring no dust, debris, or vegetation hampers panel performance or safety. 2.2. Preventive Maintenance 1. Solar Panels: • Visual inspection of panels for cracks, discoloration, or damage. • Verification of proper mounting and alignment of modules. 2. Inverters: • Cleaning and inspection of inverters for proper operation. • Checking cable terminations, earthing, and performance logs. 3. Cabling and Connections: • Checking all DC and AC cables for insulation issues, loose connections, or damage. • Ensuring proper cable routing and securing with clamps or ties. 4. Monitoring Systems: • Inspect SCADA or data loggers for proper functioning and accurate reporting. • Calibrate sensors (if applicable). 5. Structures and Mountings: • Checking mounting structures for corrosion, loosened bolts, or alignment issues. 6. Battery Banks (if any): • Inspection of batteries for electrolyte levels, connections, and overall health. 2.3. Breakdown Maintenance: 1. Respond to any faults within 24 hours of reporting. 2. Rectify issues related to: • Panel damage or inefficiency. • Inverter or electrical faults. • Cabling faults or loose terminations. 3. Replace defective parts (spare parts supplied by the owner or contractor as per contract terms). 2.4. Reports and Documentation 1. Submission of monthly O&M reports detailing: • Cleaning schedules and activities completed. • Performance data (energy generated, plant efficiency, and downtime). • Maintenance activities conducted. 2. Immediate reporting of faults, along with root cause analysis and corrective measures. 3. Maintaining an on-site logbook for all maintenance and operational activities. 3. Contractor’s Responsibilities 1. Deploy trained manpower to carry out maintenance activities. 2. Provide all necessary tools, equipment, and consumables for maintenance and cleaning. 3. Ensure adherence to safety standards and guidelines. 4. Provide insurance coverage for their personnel. 5. Use only approved cleaning agents and tools that do not harm the solar modules or components.

-

-

-

... More
2.2. Preventive Maintenance 1. Solar Panels: • Visual inspection of panels for cracks, discoloration, or damage. • Verification of proper mounting and alignment of modules. 2. Inverters: • Cleaning and inspection of inverters for proper operation. • Checking cable terminations, earthing, and performance logs. 3. Cabling and Connections: • Checking all DC and AC cables for insulation issues, loose connections, or damage. • Ensuring proper cable routing and securing with clamps or ties. 4. Monitoring Systems: • Inspect SCADA or data loggers for proper functioning and accurate reporting. • Calibrate sensors (if applicable). 5. Structures and Mountings: • Checking mounting structures for corrosion, loosened bolts, or alignment issues. 6. Battery Banks (if any): • Inspection of batteries for electrolyte levels, connections, and overall health.

-

-

-

... More
2.3. Breakdown Maintenance: 1. Respond to any faults within 24 hours of reporting. 2. Rectify issues related to: • Panel damage or inefficiency. • Inverter or electrical faults. • Cabling faults or loose terminations. 3. Replace defective parts (spare parts supplied by the owner or contractor as per contract terms).

-

-

-

... More
2.4. Reports and Documentation 1. Submission of monthly O&M reports detailing: • Cleaning schedules and activities completed. • Performance data (energy generated, plant efficiency, and downtime). • Maintenance activities conducted. 2. Immediate reporting of faults, along with root cause analysis and corrective measures. 3. Maintaining an on-site logbook for all maintenance and operational activities. 3. Contractor’s Responsibilities 1. Deploy trained manpower to carry out maintenance activities. 2. Provide all necessary tools, equipment, and consumables for maintenance and cleaning. 3. Ensure adherence to safety standards and guidelines. 4. Provide insurance coverage for their personnel. 5. Use only approved cleaning agents and tools that do not harm the solar modules or components.

-

-

-

... More
4. Performance Standards 1. Ensure at least 98% plant availability during the contract period. 2. Maintain performance ratio (PR) above the agreed threshold (typically 75-80%). 3. Prevent downtime due to negligence in maintenance or delays in fault resolution. 5. Exclusions • Replacement of major parts (panels, inverters, transformer) unless otherwise agreed. • Force majeure events like natural calamities or vandalism. 6. Payment Terms 1. Payment to be made on a monthly basis upon submission of: • Monthly O&M report. • Invoice and certification of work by the site in-charge. 2. Deductions may apply if performance standards or scope of work is not met. 7. Safety and Compliance 1. Follow all applicable safety protocols while working on the plant. 2. Ensure compliance with electrical safety standards and regulations. 8. Penalty per day for failure to respond to faults within the agreed time. • Penalty of Rs. 1000 for failure to meet cleaning schedules.

-

-

-

... More
M & L in replacement for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified.

20

-

-

... More
S&F in replacement of Energy saving environment friendly High mast Light with innovative di cast aluminium IP 66 Flood light fitting with 230Volts, 50Hz, 120W LED as light source complete all as specified and as directed Note: All fixing material is included in the unit rate.

25

-

-

... More
Supply only fuse wire tinned Cu rated for 50 Amps confirming to IS 9224 suitable for 415 volts for use in rewirable fuse units as per staandard al as directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing GI strip in trenches or wall 32 x 6 mm galvanised iron strip complete all as specified and directed.

90

-

-

... More
Taking down old unserviceable Bldg security light S&F high efficent LED building security light 30 watt , 230 V , lumen 2000 -3000, PF 0.9, THD less 10%, made of pressutre cast aluminuim housing with high power LEDs, lens and touughned glass IP 66 connecting with three core flexible copper wire from connecto to ceiling rose complete all as specified and directed by Engr-in-Charge.

50

-

-

... More
S & F in replacement of bracket for mounting building security light made out of 40 mm dia Light Grade GI pipe 1.2 metre bend in angle with holding MS clamps two nos each bracket of size 25x3 mm including screw etc for fixing all as specified and dirrected.

30

-

-

... More
Supply and fixing of cable insulation roll of length 20 metre each complete as per directed .

100

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.