Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681460_1Bid Award Id
ViewTender No
GE/SRA/T-52/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F in repairs Geyser Element, cup/triangular/threaded type, 1.5 KW, ISI Mark (as approved), complete all as specified and as directed.
300
-
-
... More
S&F in repairs Geyser Element, cup/triangular/threaded type, 2.0 KW, ISI Mark (as approved), complete all as specified and as directed.
250
-
-
... More
S&F in repairs Gasket Rubber Ring for Heater Plate of any size Geyser (as per site), complete all as specified and as directed.
110
-
-
... More
S&F in repairs Indicating Neon Lamp Red / Green, Round/Square in shape (as approved), suitable for Geyser 25 to 50 Litre capacity, complete all as specified and as directed.
250
-
-
... More
S&F in repairs Insulation Material Glass Wool complete (as approved) and filling in Geysers 25/50 Litre capacity, complete all as specified and as directed.
20
-
-
... More
S&F in repairs Inner Steel Tank, ISI marked suitable for Electric Water Heater 25 Litre capacity of any Make and type with 16 Gauge of Steel Sheet, complete all as specified and as directed.
55
-
-
... More
S&F in repairs Inner Steel Tank ISI marked suitable for Electric Water Heater 50 Litre capacity of any Make and type with 16 Gauge of Steel Sheet, complete all as specified and as directed.
40
-
-
... More
S&F in repairs Outer Cover ISI Marked of Inner Tank suitable for Electric Water Heater 25 Litre capacity of any Make any type made up of Mild Steel Sheet Cover 1.6mm thick, complete all as specified and as directed.
40
-
-
... More
S&F in repairs Outer Cover ISI marked of Inner Tank suitable for Electric Water Heater 50 Litre capacity of any Make any type made up of Mild Steel Sheet Cover 1.6mm thick, complete all as specified and as directed.
20
-
-
... More
S&F in repairs PRV (Pressure Release Valve) suitable for Geyser 25 to 50 Litre capacity, complete all as specified and as directed.
310
-
-
... More
S&F in repairs Safety Fusible Plug, ISI marked suitable for Geyser 25/50 Litre capacity, complete all as specified and directed.
220
-
-
... More
S&F in repairs Syphon Assembly suitable for Geyser 25 Litre capacity of any Make and type including Rubber Gaskets with Nut, Bolts & Washers, complete all as specified and as directed.
220
-
-
... More
S&F in repairs Syphon Assembly suitable for Geyser 50 Litre capacity of any Make and type including Rubber Gaskets with Nut, Bolts & Washers, complete all as specified and as directed.
40
-
-
... More
S&F in repairs Thermostat 11 inch and cutout Temp Range 30-90 degree centigrade manual reset type, ISI Mark , complete all as specified and as directed.
330
-
-
... More
M&L Repairing leakage of Copper/Steel Inner Tank of Geyser of any capacity by Gas Welding/ Brazing for Water Tightness and Testing under Pressure, complete all as specified and as directed.
20
-
-
... More
M&L preparaing Old Painted Steel Surfaces of Geyser of any Make, size or capacity by applying Putty to make the surface smooth and even and applying one coat of Synthetic Enamel Paint White, complete all as specified and as directed.
30
-
-
... More
M&L for descaling of electric water geyser 25/50 litre by opening apparatus plate and pvc flexible pipe and descaling with nylon wire brush first with descaling chemical till all scales are removed and then with plain water complete all as specified and as directed by Engr-in-charge
50
-
-
... More
S&F in repairs PVC Connection pipe, heavy duty (suitable for hot water), 15/20mm dia in size with PTMT Nuts of length 450mm complete all as specified and as directed.
110
-
-
... More
S&F in repairs PVC Connection pipe, heavy duty (suitable for hot water), 15/20mm dia in size with PTMT Nuts of length 600mm complete all as specified and as directed.
200
-
-
... More
S&F in repair angle valve , 15 mm bore, cast copper alloy, chromium plated fancy type, concealed type with wall flange fixed to iron pipe complete all as specified and directed.
20
-
-
... More
S&F in repairs Metal Clad Industrial Plug Top 20 Amps ISI marked (as approved), complete all as specified and as directed.
90
-
-
... More
S&F in repairs Metal Clad Industrial Socket 20 Amps ISI marked (as approved), complete all as specified and as directed.
90
-
-
... More
S&F in repairs Sheet Metal Enclosure with Metallic Socket, Plug Top and MCB Single Pole 20 Amp with 2 Pin & Earth Plug and Socket ISI marked (as approved), complete all as specified and as directed.
60
-
-
... More
S&F in repairs Polycarbonate/bakelite Plug Top 16/20 Amp, ISI marked (as approved), complete all as specified and directed.
220
-
-
... More
S&F in repairs Polycarbonate/bakelite new socket outlet, flush type with indicator lamp, 16/20 Amps complete all as specified and directed.
210
-
-
... More
S&F in repairs Polycarbonate/bakelite piano switch, flush type, 16/20 Amps complete all as specified and directed.
210
-
-
... More
S&F in repairs PVC insulated, multi-stranded sheathed Copper Conductor Cable of size 2.5 Sqmm, 3 Core complete all as specified and as directed.
50
-
-
... More
S&F in repairs PVC insulated, multi-stranded sheathed Copper Conductor Cable of size 4 Sqmm, 3 Core complete all as specified and as directed.
60
-
-
... More
S&F in repairs MCB, 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed.
155
-
-
... More
S&F in repairs MCB, 'C' series, SP, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed.
330
-
-
... More
M&L for concealed type point wiring with 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC casing capping/conduit complete with all fittings and accessories, fixed to walls/ceiling including providng mild steel terminal boxes 1.20 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/sockets etc with and including 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one 3/6 pin 16/20 Amp socket outlet controlled by one switch on independent board including taking out old unsv wiring and testing on completion complete all as specified and directed.
(NOTE: Wiring shall be done in existing casing capping/conduit. Quoted rate shall be excusive of the cost of conduit/casing capping)
200
-
-
... More
S&F in repairs Sub-main Wiring with 2-Runs of 2.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 2.50 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in and including non-metallic rigid PVC CONDUIT concealed in wall of suitable size complete all as specified and as directed. NOTES: (i) Three runs of 2.50 sqmm wire and one run of PVC conduit shall be measured as one unit. (ii) Cost of cutting chases for concealed wiring and making good shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
320
-
-
... More
-ditto- but for Sub-main Wiring with 2-Runs of 2.50 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 2.50 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in existing PVC CONDUIT complete all as specified and as directed. (NOTE: The wires shall be provided in existing conduit. Quoted rates shall be exclusive of the cost of conduits. Three runs of wire shall be considered as one unit)
210
-
-
... More
SCH 'A' PART-II (REPAIRS TO SOLAR WATER HEATERS)
-
-
-
... More
M&L for Taking down/Dismantling Solar Water Heater Tank 500 LITRE PER DAY capacity by taking the Outer Cladding, Glass Wool and repairing Old Serviceable Inner Tank made out of Stainless Steel Sheet, re-fixing the same in Original Position with and including new Mild Steel Nut, Bolts and and Testing upto satisfactory performance, complete all as specified and as directed.
11
-
-
... More
M&L for Taking down Solar Water Heating System Collector Panel from its Position, removing the Top Glass of Solar Heat Collector and carry out welding/ brazing work to the Collector and arresting the leakages in the Collector, refixing Top Glass Back, Testing for proper satisfactory Function, complete all as specified and as directed.
10
-
-
... More
M&L for Servicing Solar FP Collector by removing the Flange Plates, cleaning the Collectors internally by using Descaling Solution, removing the blockages in the Collectors and re-fixing the Flange Plates, Testing for proper satisfactory Function, complete all as specified and as directed.
11
-
-
... More
M&L for Cleaning, washing Solar Glass Panel of Solar Water Heating System and Painting to Mild Steel Stand of Solar Water Heating System and Mild Steel Staging of Cold and Hot Water Tank with Synethic Enamelled Paint (White Colour), complete all as specified and as directed.
11
-
-
... More
M&L for Solar Water Heater Tank 500 LITRE capacity, made out from Stainless Steel Sheet 16 Gauge, fixing with and including new Nut, Bolts as per existing system, hoisted/fixing in Position, providing necessary Water & Electric Supply Connections, Testing (upto satisfactory performance) on Completion including lowering/taking down Solar Water Heater Tank of any description, complete all as specified and as directed.
4
-
-
... More
M&L for Taking down unserviceable Solar Flat Plate Collector by disconnecting Flange Plates and Rubber Hose Pipes and replacing with new Flat Plate Collector of same size and Model, connecting Flange Plates and Rubber Hose, Testing for proper satisfactory Function, complete all as specified and as directed.
10
-
-
... More
S&F in repairs Flexible Heat Resistance Rubber Pipe (from Inter Connect Plate Collector to Hot Water Tank) of size 25mm to 32mm dia with fixing Clamp, etc. , complete all as specified and as directed.
30
-
-
... More
S&F in repairs Hot water pipe duly insulated with glass wool and aluminium cladding 15 mm bore helical/cone/cup type complete all as specified and as directed.
27
-
-
... More
S&F in repairs Heating Element for Solar Water Heating Plant of capacity 3.0 KW, ISI Marked , complete all as specified and as directed.
12
-
-
... More
S&F in repairs Thermostat for Solar Water Heating Plant suitable for 3.0 KW to 5.0 KW, complete all as specified and as directed.
10
-
-
... More
M&L for providing Mild Steel sections, conforming to Fe-290 Gde-E-165 for stand/frame of solar water heater including cutting, fabricating, welding and fixing as per existing size and design alongwith requisite nuts, bolts & washers including grouting on wall/roof and painting with two coats of synthetic enamel paint over a coat of red oxide primer including taking down/dismantling of existing frame or sections complete all as specified and directed.
1
-
-
... More
M&L for PCC 1:2:4 type B1 (20 mm graded aggregates) as in grouting/base of solar water heater frame/stand including necessary formwork complete all as specified and directed.
1
-
-
... More
Taking up or down CPVC/Steel Tubing 15mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and directed.
115
-
-
... More
Taking up or down CPVC/Steel Tubing 20mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and directed.
90
-
-
... More
Taking up or down CPVC/Steel Tubing 25mm bore (dia) with Fittings/ Connections, segregating Serviceable Pipes and Fittings/ Connections and keep in Safe Custody for re-use, complete all as specified and directed.
45
-
-
... More
S&F Galvanised Tubes 15 mm bore (dia), 'medium grade', with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, complete all as specified and as directed.
45
-
-
... More
S&F Galvanised Tubes 20 mm bore (dia), 'medium grade', with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, complete all as specified and as directed.
40
-
-
... More
S&F Galvanised Tubes 25 mm bore (dia), 'medium grade', with all Fitting and fixed complete to Walls and Ceilings or laid in Floors, complete all as specified and as directed.
20
-
-
... More
S&F Chlorinated Polyethylene Chloride (CPVC) pipes, SDR 11, 20 mm outside dia, having thermal stability for hot and cold water supply including all SDR 11 CPVC plain and brass threaded fittings (such as Bends, Elbows, Tees, Short Pieces, Connectors, Back - Nuts Caps, Plugs, Unions, Flange (core) & flange (ring), reduction Tee, reducing socket, Male & female threaded socket, tank connector etc) fixed / laying walls, ceilings or in floors etc. with suitable size MS clamp of spacing 1.00 mtr etc pipe line complete all as specified and directed.
70
-
-
... More
-ditto- but with 25 mm outer dia size CPVC pipes
50
-
-
... More
-ditto- but with 32 mm outer dia size CPVC pipes
25
-
-
... More
S&F CPVC Ball valve 20mm (outer dia), screwed both Ends for CPVC pipes, complete all as specified and directed.
2
-
-
... More
S&F CPVC Ball valve 25mm (outer dia), screwed both Ends for CPVC pipes, complete all as specified and directed.
2
-
-
... More
S&F CPVC Ball valve 32mm (outer dia), screwed both Ends for CPVC pipes, complete all as specified and directed.
2
-
-
... More
NOTE FOR ITEM NO 02 :- (a) Quoted rates shal be deemed to include for the cost of petty spares, accessories (other than considered in BOQ) and consumable for satisfactory completion of the job. No claim shall be entertained during currency of work.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements