Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 1,34,215Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_691215_1Tender No
CWE/CHM(U)-101/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(C) Auto Main Failure(AMF): (i) AMF control panel suitable for 400KVA DG set consisting of overload relay, under current relay, phase failure detector, battery charger, delay timer consisting of quick auto mode system. AMF panel shall be floor mounted, outdoor type 3.15mm thick CRCA sheet including meter connected and copper busbar of suitable rating and also having data logging history of engine etc.
(ii) LED display designed to meet temp compensation, Start/Stop engine metering,oil pressure, coolent temp, battery voltage, engine speed,and AC alternator metering.
(iii) 4 Pole ACBs 630 Amp with microprocessor release, 50 KA breaking capacity, electical drawout type(EOD) having overload, short circuit and earth fault protection alongwith LED display.
-
-
-
... More
(D) METALLASTIC : Anti-vibration pads for mounting engine, alternator assembly on the base frame/ plate. (E) BASE PLATE: Base Plate shall be made out of structural steel as per manufacturer's recommended design/ specifications.
-
-
-
... More
(F) ACOUSTIC ENCLOSURE : Provision of an integral type approved/ certified acoustic enclosure weather proof, water proof and corrosion free, as per latest CPCB norms IV or latest, for the DG Sets to restrict the noise level to 75 db at one meter distance and temp rise within canopy shall not exceed 50 - 70 degree Celsius. It shall be made of minimum 14 SWG CRCA MS Sheet with powder coated finish on outside and provided with non igniting fire retardant foam as acoustic material. There shall be four hinged doors out of which one shall be with a glass window. The base shall be of ISMB section all as directed and shall include as under:-
-
-
-
... More
(i) Silencer shall be absorption type, non resistance, residential and exhaust pipe covered with asbestos roof extending to about 2 meters outside the acoustic enclosures.
(ii) Internal wiring with PVC copper conductor cables, IS - 694 marked, FRLSH in conduit and fluorescent lamp fittings. (iii) Fuel tank of capacity sufficient to continously run the DG set atleast upto 8 hours made out of 14 SWG CRCA MS sheet, duly powder coated and provided with float, gauge and fuel float switch - 01 Set.
-
-
-
... More
Note: (i) DG set shall be "pre-commissioned" by rep of Accepting Officer within overall cost quoted. Fuel for "Pre-commissioned" test shall be arranged by contractor.
(ii) Before delivery/dispatch of DG Set(s) from approved manufacturing unit, the contractor shall give notice to the GE and accepting officer before one month for consideration by accepting officer and detailing the representative to witness the factor testing (routine tests as per IS) at factory premises. Necessary arrangement & tie up the manufacturer etc, the test will be of contractor’s responsibility without any extra cost to the Govt.
(iii) Suitable capacity battery maintenace free as per OEM recommendation shall be provided within overall quoted rates.
(iv) If any modification are required on existing main panel, it will be deemed in contract quoted rate.
(v) Drawing for AMF panel and LT supply shall be approved by GE before placement of order and installation.
-
-
-
... More
M&L for construction of plateform for 400 KVA DG Set, by constructing 400 mm thick in Concrete mix RCC 1:2:4 Block of approximate size 5600 mm X 2200 mm with nominal reinforcement type B-1 (using 20 mm thick graded stone aggregates) as in flooring and 230 mm thick brick wall masonry in cement mortar 1:4 all around the PCC Block along the perimeter leaving a gap of 75 mm between PCC block and brick wall masonry and filling the gap with sand from all sides over and including 50 mm thick PCC 1:4:8 type D-2 (using 40 mm thick graded stone aggregates) as in sub base including 15 mm thick plastering on the exposed brick wall masonry in cement mortar 1:4 and applying two coats of white wash on newly plastered surface complete all as specified and as directed by Engineer-in-Charge.
1
-
-
... More
Note:(i) Size of the plateform for DG Set mentioned above is approximate, Final size of plateform shall be as per the recommendtion of OEM and as directed by Engineer-in-charge.
(ii) necessary Excavation if required shall deemed to be included in the rate quoted.
-
-
-
... More
M&L for earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connecting to GI strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth wire protected by 50mm dia GI pipe medium grade earth plate surrounded by alternate layer of coal dust and common solt 15 cm thik each layer all as per electrical plate and connected to pole structure/ panel board/ earthing test point all as shown in electrical plate No. 3 of SSR Part-I (2009) and testing on completion complete all as specified and directed.
6
-
-
... More
Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C-1 pit, 40mm thick RCC 1:2:4 mix type B-1 cover reinforced with 8 mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe, earth strip with protection pipe upto 7.50 m long.
-
-
-
... More
Supply and fixing GI strip 32 mm x 6 mm buried in ground complete all as specified and as diected by Engineer-in-Charge.
10
-
-
... More
Supply and fixing GI pipe 'light grade' of size 40 mm dia for strip protection complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
Supplying, laying, jointing and testing LT XLPE insulated cable, 1100 volt grade heavy duty armoured aluminium conductor including cable glands, cable lugs etc to suit the cable size, laid in trenches, fixed along the poles bare or through GI pipe laid under floor/ road, concealed in walls, encased in GI pipe etc complete of size 400 Sqmm single core complete all as specified an as directed by engineer-in-charge.
(Note:- Earthwork shall be measured and paid separately)
280
-
-
... More
Excavation in trenches for foundations, laying, erecting of poles etc, in any type of soil, not exceeding 1.5 metre in depth and not exceeding 1.5 metre in width and getting out, complete all as specified and as directed by Engineer-in-Charge. Note:- Nothing extra will be paid to the contractor in this account if hard or rocky soil is encoutered during the execution.
70
-
-
... More
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed by Engineer-in-Charge.
52
-
-
... More
Removing surplus excavated material to a distance not exc 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-Charge.
18
-
-
... More
M&L for sand cushioning for underground cable 8 cm below and 15 cm above the cable with clean dry river sand in trenches including spreading, levelling etc. complete all as specified and as directed by Engineer-in-Charge.
Note: Punned thickness only will be measured for the purpose of payment.
20
-
-
... More
Supply and laying reinforced precast concrete cable cover class LV type-1, flat, size 250 mm x 150 mm x 40 mm as protection to LT cable complete all as specified and as directed by Engineer-in-Charge.
1800
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%