Military Engineer Services Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 94,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677838_1Bid Award Id
ViewTender No
GE (AF) Gurgaon No 1/GUR-31/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://mes.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Annual Cleaning of Oil & Grease Strap tank, Equilization tank, CCT Tank, sludge tank & Treated water tank of 250 KLPD Plant complete all as specified and as directed by Engr-in-charge. Note :- Cleaning shall be carried out by the following methods:- (i) Removing all the existing water from the tank through tankers. (ii) Cleaning inner surface of tank by scraping with steel wire brush and removing mud & sludge collected inside the tanks manually at a distance not exceeding 50 Mtrs. (iiI) Washing with clean water & bleaching powder mixture complete tank internally and removal of left out sludge. (iii) Labour and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same where approved by the PCB. (iv) All Safety measures to be taken by the contractor for doing the cleaning.
1
-
-
Annual Cleaning of Oil & Grease Strap tank, Equilization tank, CCT Tank, sludge tank & Treated water tank of 85 KLPD Plant complete all as specified and as directed by Engr-in-charge. Note :- Cleaning shall be carried out by the following methods
(i) Removing all the existing water from the tank through tankers.
(ii) Cleaning inner surface of tank by scraping with steel wire brush and removing mud & sludge collected inside the tanks manually at a distance not exceeding 50 Mtrs. (iiI) Washing with clean water & bleaching powder mixture complete tank internally and removal of left out sludge. (iii) Labour and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same where approved by the PCB. (iv) All Safety measures to be taken by the contractor for doing the cleaning.
1
-
-
M&L for Cleaning of sludge chamber of 250KLPD Sewage treatment plant which includes removing of dry sludge and suction of muddy water. The work also includes scrubbing of internal surfaces and cleaning of walls, floors & ceiling which dislodges the layers of dirt, funges struck on its surface and applying Anti-bacterial sterlization spray to walls, floors & ceiling external surfaces of reservoirs and also remove all masses,algae,dirt by using high pressure water jet. Disposal of sludge to be done outside the station location and as per the guidelines of Govt of India.
Note : (a) If the contractor fail to clean the sludge in every 1st week of the month the penality of Rs 1000/- per day shall be recovered from RAR/Final Bill being a Hygiene and sanitation point.
(b) The retrieved sludge quantity will be charged @ Rs 1 per kg by the contractor at the time of RAR/Final Bill
(c) Certificate be provided by the contractor for safely disposal of sludge.
9
-
-
M&L for Cleaning of sludge chamber of 85KLPD Sewage treatment plant which includes removing of dry sludge and suction of muddy water. The work also includes scrubbing of internal surfaces and cleaning of walls, floors & ceiling which dislodges the layers of dirt, funges struck on its surface and applying Anti-bacterial sterlization spray to walls, floors & ceiling external surfaces of reservoirs and also remove all masses,algae,dirt by using high pressure water jet. Disposal of sludge to be done outside the station location and as per the guidelines of Govt of India complete all as specified by Engineer-in-Charge.
Note : (a) If the contractor fail to clean the sludge in every 1st week of the month the penality of Rs 1000/- per day shall be recovered from RAR/Final Bill being a Hygiene and sanitation point. (b) The retrieved sludge quantity will be charged @ Rs 1 per kg by the contractor at the time of RAR/Final Bill
(c) Certificate be provided by the contractor for safely disposal of sludge.
9
-
-
Supply , laying and fixing in replacement of HDPE pipe outer Dia of 110mm dia of PE -63, IS: 4984:1995 material Black colour having 6kgf/cm2 pressure rating all as specified and directed by Engr-in-Charge.
2000
-
-
Supply , laying and fixing in replacement of HDPE pipe of outer Dia 90mm dia of PE -63 IS: 4984:1995 material Black colour having 6kgf/cm2 pressure rating all as specified and directed by Engr-in-Charge.
1500
-
-
Supply , laying and fixing in replacement of HDPE pipe of outer Dia 50mm dia of PE -63 IS: 4984:1995 material Black colour having 6kgf/cm2 pressure rating all as specified and directed by Engr-in-Charge.
1200
-
-
Supply , laying and fixing in replacement of HDPE pipe of outer Dia 25mm dia of PE -63 IS: 4984:1995 material Black colour having 6kgf/cm2 pressure rating all as specified and directed by Engr-in-Charge.
900
-
-
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 Sqm on plan and not exc 1.5M in depth and getting only out in hard soil/standing complete all as specified and directed
2030
-
-
Returning, filling in trenches including spreading, levelling watering and well ramming in layers not exceeding 25 cms thick in each layer of oil complete all as specified and directed
1780
-
-
Removing surplus excavated material to a distance exc 50 Mtr and deposting where directed at l level not exceeding 1.5 Mtr above the starting point all as specified and directed by Engr - in Charge
250
-
-
M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecified and directed by Engr-in-Charge.
20
-
-
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete as sepecified and directed by Engr-in-Charge.
2.2
-
-
S&F in replacement of fusion joint to Compressor push joint COUPLER & R.COUPLER of Dia 110mm HDPE pipe complete all as specified and directed.
6
-
-
S&F in replacement of fusion joint to Compressor push joint COUPLER & R.COUPLER of Dia 900mm HDPE pipe complete all as specified and directed.
6
-
-
S&F in replacement of fusion joint to Compressor push joint COUPLER & R.COUPLER of Dia 50mm HDPE pipe complete all as specified and directed.
10
-
-
S&F in replacement of fusion joint to Compressor push joint 90 ELBOW of Dia 110mm HDPE pipe complete all as specified and directed.
4
-
-
S&F in replacement of fusion joint to Compressor push joint 90 ELBOW of Dia 90mm HDPE pipe complete all as specified and directed.
4
-
-
S&F in replacement of fusion joint to Compressor push joint 90 ELBOW of Dia 50mm HDPE pipe complete all as specified and directed.
4
-
-
S&F in replacement of fusion joint to Compressor push joint TEE & R.TEE of Dia 110mm HDPE pipe complete all as specified and directed.
2
-
-
S&F in replacement of fusion joint to Compressor push joint TEE & R.TEE of Dia 90mm HDPE pipe complete all as specified and directed.
3
-
-
S&F in replacement of fusion joint to Compressor push joint TEE & R.TEE of Dia 50mm HDPE pipe complete all as specified and directed.
3
-
-
S&F in replacement of fusion joint to Compressor push joint End cap of Dia 110mm HDPE pipe complete all as specified and directed.
3
-
-
S&F in replacement of fusion joint to Compressor push joint End cap of Dia 90mm HDPE pipe complete all as specified and directed.
3
-
-
S&F in replacement of fusion joint to Compressor push joint End cap of Dia 50mm HDPE pipe complete all as specified and directed.
4
-
-
S&F in replacement of Air Release Valve of 110mm Dia alongwith Saddle and UPVC pipe all as specified and directed by Engr-in-charge
3
-
-
S&F in replacement of Air Release Valve of 90mm Dia alongwith Saddle and UPVC pipe all as specified and directed by Engr-in-charge
2
-
-
S&F in replacement of Air Release Valve of 50mm Dia alongwith Saddle and UPVC pipe all as specified and directed by Engr-in-charge
4
-
-
S&F in replacement of Ball Valve of 110mm Dia all as specified and directed by Engr-in-charge
4
-
-
S&F in replacement of Ball Valve of 90mm Dia all as specified and directed by Engr-in-charge
4
-
-
S&F in replacement of Ball Valve of 50mm Dia all as specified and directed by Engr-in-charge
4
-
-
S&F in replacement of fusion joint to Compressor push joint reducer 110mm x 90mm Dia HDPE pipe complete all as specified and directed.
10
-
-
S&F in replacement of fusion joint to Compressor push joint reducer 90mm x 50mm Dia HDPE pipe complete all as specified and directed.
6
-
-
S&F in replacement of fusion joint to Compressor push joint reducer 50mm x 25mm Dia HDPE pipe complete all as specified and directed.
8
-
-
M& L in replacement of standpost to water sprinkler plastic 15-18mtr range, Type Pop Up 25 mm dia all as specified and directed by Engr-in-charge
40
-
-
M&L for filling of tube media including removing the water and cleaning Tube Settler Tank complete from the tank complete all as specified and directed by Engr-in-Charge
13
-
-
M&L for filling of Fab MBBR media including removing the water and cleaning complete from the MBBR tank 1 & 2 complete all as specified and directed by Engr-in-Charge.
Note: Water to be removed through filling of water tankers and thereafter cleaning to be done all this rate is included in quoted rate.
13
-
-
S&F of Dosing Pump IMP 64 Diaphragm Water Pump (0.5 hp) , Electrical 230 V AC, 50 Hz., Splash-proof enclosure, Dosing rate @ 4 Kg/Cm² & 10.0 Lph, Built in air release valve (ARV) , IP 65 certified, Suction/Discharge tubing 4/6 mm complete all as specified and directed by Engr-in-Charge.
2
-
-
M&L for filling of Sand media including removing the water and cleaning complete from Sand Filter complete all as specified and directed by Engr-in-Charge
3000
-
-
M&L for filling of Carbon media including removing the water and cleaning complete from Carbon Filter complete all as specified and directed by Engr-in-Charge
700
-
-
M&L for filling of EM Bio Culture all as specified and directed by Engr-in-Charge
5
-
-
M&L for filling of Bacteria solvent all as specified and directed by Engr-in-Charge
40
-
-
M&L for filling of urea all as specified and directed by Engr-in-Charge
150
-
-
M&L for filling of DAB all as specified and directed by Engr-in-Charge
150
-
-
M&L for fixing of butterfly valve 2" in Sludge drain tank along with its fixture and fitting complete all as specified and directed by Engr-in-charge
1
-
-
M&L for pressure gauge (4") 7Kg alongwith its fitting and fixture all as specified and directed by Engr-in-Charge
4
-
-
S&F GI Butterfly valve 4" size alongwith all its fixtures and fittings all as specified and directed by Engr-in-charge
3
-
-
S&F GI Butterfly valve 3" size alongwith all its fixtures and fittings all as specified and directed by Engr-in-charge
2
-
-
M&L CVD diffuser in MBBR Tank complete all as specified and directed by Engr-in-Charge
20
-
-
M&L in replacement of GI Pipe 50mm dia alongwith Tee & Elbow complete all as specified and directed by Engr-in-charge
40
-
-
M& L for Repair & testing of parts of starter panels complete all as specified and as directed by Engr-in-charge.
(Note;- The rate also includes change of Wiring of any size in the panel. Parts required are seperately measured in the schedule)
6
-
-
S&F in replacement Voltage monitor relay (3 phase ) AC : 110/ 415Volt Setting 75 -100/300 - 400 V, complete all as specified and directed by Engineer-in-Charge.
3
-
-
Supply and fix in replacement Over current relay definite time Non directional ,definite time & current adjustable setting 0.5 -5A 1-10A /0.1-1A time 0-10 sec, complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply & Fixing only Electronic Phase sequencing relay Make:Universal or equivalent
3
-
-
S & F in replacement of Contractor MNX 25, 240V 50/60Hz upto 500V,50/80Hz 3 Pole all as specified and as directed by Engr-in-Charge
2
-
-
S & F in replacement of Contractor MNX 18, 240V 50/60Hz upto 500V,50/80Hz 3 Pole all as specified and as directed by Engr-in-Charge
6
-
-
S & F in replacement of Contractor MNX A2, 240V 50/60Hz upto 500V,50/80Hz 3 Pole all as specified and as directed by Engr-in-Charge
3
-
-
S & F in replacement of Contractor MNX 9, 240V 50/60Hz upto 500V,50/80Hz 3 Pole all as specified and as directed by Engr-in-Charge
3
-
-
Supply & Fix in replacement of MCCB 63 Amps, 4 pole 415 V conform to IS/IE60947-2 with breaking capacity 16 KA Adjustable Thermal and Fixed Magnetic complete.
2
-
-
S&F of MCCB 100 Amps 4 pole 415 Volts conform to IS/IE60947-2 with breaking capacity 16 KA Adjustable Thermal and Fixed Magnetic complete all as specified and directed.
3
-
-
M&L complete for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of HDPE pipe by means of bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.
50
-
-
S&F of Float Valve 80mm dia size all as specified and directed by Engr-in-Charge
2
-
-
M&L for replacement of perforated cable tray 16SWG of width 150mm(6") complete all as specified and directed by Engr-in-charge
50
-
-
M&L Preperation of old painted Steel surface of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of Red oxide primer all as specified and directed by Engineer -in-charge
1250
-
-
S&F Valve box all as specified and directed by Engr-in-charge
6
-
-
M&L for disconnecting the electric and pipe connections for lifting/taking out the pipe of any dia from the well upto a depth of 50 meters and including cable, SWR rope, submersible pump and motor of any capacity and size for carrying out the necessary repair work and lowering the pumpset motor alongwith pipe, cable, SWR rope after repair and connecting electric and pipe connection as per existing etc complete all as specified and directed by Engineer-in-Charge. Note :- (i) Contractor shall take proper precautions while taking out and lowering pump set in well so as to avoid any damage to pipe and cable. All necessary T&P and equipments required fo taking out and lowering of pump set etc shall be arranged by the contractor at his own cost. (ii) Rates quoted by the contractor for the above item includes the cost of assembling & connecting pump set to pipes & assembling, jointing and fixing column pipes / pump sets / cable and making necessary connections and testing including reconnecting system.
8
-
-
M&L for transporting the motor / pump of any make and capacity to the workshop, opening of the motor after unscrewing nuts, bolts and washers, checking the serviceability of windings, electrically and manually, and transporting back to the existing site from workshop after carrying out the repair work, complete all as specified and directed by Engineer-in-Charge.
8
-
-
M&L for cutting and taking out unserviceable copper wire windings from the rotor grooves of the SUBMERSIBLE SEWAGE NON CLOG PUMP, 7.5HP, cleaning the grooves/ rotor with chemical reagent, re – winding the same with super enamelled PVC insulated copper wire of suitable gauge (Approx Kgs -4.5Kg) including teflon tape insulating paper jointing material and other accessories etc complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for cutting and taking out unserviceable copper wire windings from the rotor grooves of the SUBMERSIBLE SEWAGE NON CLOG PUMP, 12.5hp, cleaning the grooves/ rotor with chemical reagent, re – winding the same with super enamelled PVC insulated copper wire of suitable gauge (Approx Kgs -5Kg) including teflon tape insulating paper jointing material and other accessories etc complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for cutting and taking out unserviceable copper wire windings from the rotor grooves of the 25 HP submersible motor, cleaning the grooves/ rotor with chemical reagent, re – winding the same with super enamelled PVC insulated copper wire of suitable gauge (Approx Kgs - 7.5) including teflon tape insulating paper jointing material and other accessories etc complete all as specified and directed by Engineer-in-Charge.
2
-
-
M&L for cutting and taking out unserviceable copper wire windings from the rotor grooves of the 2.5 HP submersible motor, cleaning the grooves/ rotor with chemical reagent, re – winding the same with super enamelled PVC insulated copper wire of suitable gauge (Approx Kgs - 9.5) including teflon tape insulating paper jointing material and other accessories etc complete all as specified and directed by Engineer-in-Charge.
2
-
-
Monthly Technician charges for checkingup working of STP Plant or whenever required all as specified and directed by Engr-in-charge
18
-
-
Supply and fixing of Screen Filter and Disc filter fixed in 3'' MS pipe with flange Joint alongwith Gell type Pressure Gauge , Air Release Valve , Filter Support and Pressure Relief Valve Hydraulic type alongwith connected accessories including pipe all as specified and directed by Engr-in-Charge
1
-
-
Supply and fixing of Screen Filter and Disc filter fixed in 2'' MS pipe with flange Joint alongwith Gell type Pressure Gauge , Air Release Valve , Filter Support and Pressure Relief Valve Hydraulic type alongwith connected accessories including pipe all as specified and directed by Engr-in-Charge
1
-
-
Monthly charges for cleaning of filters or whenever required all as specified and directed by Engr-in-charge
18
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core all as specified and directed
250
-
-
Note:- (a) The amount of Rs 127584/- against Schedule of Credit on Page No 116 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
-
-
-