Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date17 Dec 2024
Closing Date18 Jan 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L rendering 10 mm thick on concrete surfaces of slab in CM 1:3 with admixture of liquid water proofing compound @ 250 ml per bag of cement on green concrete surfaces complete all specified and directed. Note: Water proofing shall be measured & paid separately.

460

-

-

... More
M & L applying evenly a tack coat of industrial bituman 85/25 @ 1.2 Kg / Sqm on plaster surface including cleaning of surfaces all as specified and directed by Engineer – in – Charge

460

-

-

... More
M&L for APP based polymeric membrane minimum weight 3kg per sqm and minimum 3mm thick reinforced with polyster non wove fabric laid over primed surface by force application complete all as specified and directed.

460

-

-

... More
Cleaning existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and applying two coats of alkaline rust converting primer with a coverage of 350gm per sqm on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluable and adhesive protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats. Product: Sika Rustoff-100 or equivalent makes M/s Fosroc or M/s Pidlite. Note: Measurement per sqm surface area of concrete shall be considered for payment.

50

-

-

... More
Providing and application of zinc rich epoxy anti-corrosive protective coating for rebar corrosion protection system in 2 coats of 0.4 kg per sqm. The product should confirm carbonation resistance of 2 mm and bond strength 1N/mm2 according to ASTM C 882-78. Product: SikaTop Armatec-108 Plus or equivalent makes M/s Fosroc or M/s Pidlite. Note: Measurement will be surface area of concrete shall be considered for payment.

50

-

-

... More
M&L providing and applying 15-20 mm thick layer of single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementious structural repair mortar conforming to EN 1504-3 Class R4 on exposed concrete surface as per technical specification. Material should have Compressive strength ≥ 55 MPa as per EN:12190, Chloride ion content ≤ 0.05% as per EN:1015-17, Adhesive bond ≥ 2.0 MPa as per EN:1542, Carbonation resistance dk ≤ control concrete [MC(0,45)] as per EN:13295 & Elastic modulus ≥ 20.0 GPa as per EN:13412. (Complete finished item with all leads and lifts) Product: Sika MonoTop-122F or equivalent makes M/s Fosroc or M/s Pidlite. Note: Measurement will be surface area of concrete shall be considered for payment.

50

-

-

... More
Demolition brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removing of debris from the site complete all as specified.

10

-

-

... More
M&L Brick work with sub class 'B' old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .

10

-

-

... More
Taking down cement plaster/ terrazo finish on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer - in - Charge.

1200

-

-

... More
M & L rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 finished even & smooth without using extra cement all as specified and directed by Engineer - in - Charge .

250

-

-

... More
M & L two coats of distemper oil emulsion over chalk whiting, preparatory to distempering, on newly plastered surfaces of walls including preparation of surfaces all as specified and directed by Engineer - in - Charge.

250

-

-

... More
M & L 15mm thick rendering in Cement Mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge. Note:- The rates do not include for the supply of integral water proofing compound, which shall be paid for in addition at “supplied only rates separately, as applicable.

1100

-

-

... More
M & L two coats of cement base paint over alkali resistant primer, preparatory old surfaces after complete removal of existing treatment all as specified and directed by Engineer - in - Charge.

1800

-

-

... More
M & L applying two coat of cement base paint on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in – Charge

1100

-

-

... More
Supply only liquid waterproofing compound all as specified and directed by Engineer - in - Charge.

80

-

-

... More
M & L two coat of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge .

1600

-

-

... More
M & L two coats of distemper oil emulsion over a coat of wall putty (Asian / JK / Birla), preparatory to distempering on old surfaces after complete removal of existing treatment all as specified and directed by Engineer - in - Charge.

1200

-

-

... More
M & L for preparation of old painted wooden surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge .

30

-

-

... More
M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge .

200

-

-

... More
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge .

36

-

-

... More
M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge.

480

-

-

... More
Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.all as specified and directed by Engineer - in - Charge.

480

-

-

... More
M & L for 75mm thick cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in plinth protection etc with joints filled wih sand mix or bituminous at every interval of 3 metre all as specified and directed by Engineer - in - Charge.

100

-

-

... More
Dismantling floor or wall tiles including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer - in – Charge.

360

-

-

... More
M & L for glazed ceramic coloured tiles 7mm thick 450 x 350mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick cement sand plaster (1:4) complete all as specified and directed by Engineer - in - Charge.

210

-

-

... More
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and all as specified and directed by Engineer - in - Charge.

5

-

-

... More
Taking down chowkhats or frames with shutters without taking off shutters from the frame not exceeding 1.5 Sqm each and all as specified and directed by Engineer - in - Charge.

3

-

-

... More
S & F pressed steel door frames with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, size of frame 105X60mm , complete all as specified and directed by Engineer - in – Charge .

25.5

-

-

... More
S & F plain framed paneled shutters, any No. of panels with panels of plywood 9mm thick for two or more panel construction and 12mm for single panel construction, BWR conforming to IS fixed to timber frame of 2nd class hard wood, 30mm thick all style & rail are as per SSR Part – I all as specified and directed by Engineer – in – Charge .

12

-

-

... More
S & F Solid PVC door frame factory made of size 50mmx 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube jointed , supplying and fixing in opening complete all as specified and as directed by Engineer-in-Charge

15

-

-

... More
S&F Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying and fixing in the frame at site as per specification complete all as specified and as directed by Engineer-in-Charge.

4.5

-

-

... More
Cutting hole in brick wall built in cement mortar not exceeding half brick for fixing holdfasts in jambs and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B – 1 all as specified and directed by Engineer - in - Charge.

15

-

-

... More
S & F aluminium handle cast type anodised, 150mm long all as specified and directed by Engineer - in - Charge.

10

-

-

... More
S&F 100 mm size butt hinges, medium weight cold rolled mild steel complete all as specified and as directed by Engineer-in-Charge.

15

-

-

... More
S&F 75 mm size butt hinges, medium weight cold rolled mild steel complete all as specified and as directed by Engineer-in-Charge.

9

-

-

... More
S & F aluminium alloy anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheets cast or extruded section and fixing bolts of extruded section or cast aluminium alloy 300mm size all as specified and directed by Engineer - in – Charge .

5

-

-

... More
S & F Aluminium anodised barrel tower bolt of extruded section 150mm long all as specified and directed by Engineer - in - Charge

10

-

-

... More
S & F floor door stopper 140mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor all as specified and directed by Engineer - in - Charge.

5

-

-

... More
S & F Aluminium anodised barrel tower bolt of extruded section 100mm long all as specified and directed by Engineer - in - Charge

6

-

-

... More
S & F aluminium handle cast type anodised, 100mm long all as specified and directed by Engineer - in - Charge.

6

-

-

... More
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer - in - Charge ..

160

-

-

... More
S & F 4mm thick sheet glass ordinary quality and glazing with aluminium snap beading on aluminium frame for door, windows and ventilators in square not exceeding 0.50 sqm in each pane all as specified and directed by Engineer - in - Charge .

160

-

-

... More
M & L providing two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge .

28

-

-

... More
Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge .

0.5

-

-

... More
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed by Engineer - in - Charge.

200

-

-

... More
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engineer - in - Charge.

200

-

-

... More
Dismantling wrought iron or mild steel work of any description all as specified and directed by Engineer - in - Charge .

3

-

-

... More
S & F Rolled sections conforming to Fe-410-W (Gde E-250 Quality), as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed by Engineer-in-Charge.

300

-

-

... More
M & L for non skid ceramic coloured tiles with matt finish, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed by Engineer - in - Charge.

150

-

-

... More
Taking down carefully old and unserviceable aluminium point wiring for light/fan/socket or power point complete including fittings such as switches, ceiling rose, pendents, regulators, sockets, bell, distribution boards and MCB's etc and making good disturbed surface of walls, floors etc to match with the existing surface complete all as specified and directed.

435

-

-

... More
M & L point wiring complete with 1.5 Sqmm (nominal area) PVC FRLS insulated unsheathed copper stranded conductor cable with colour code in and including medium grade rigid PVC conduit with tees, bends, elbows, couplers, MS junction boxes concealed after cutting chases in wall, floor etc and making good to match with existing surface including sunken iron terminal box, 3mm thick bakelite sheet cover, clips, pipe hooks, brass screws, washers and 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light /bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer – in – Charge.

275

-

-

... More
All as per Srl item No. 54 here-in-before but one 06 Amp socket outlet point on independent board controlled by one, single pole, one way switch, complete all as specified and directed.

80

-

-

... More
All as per Srl item No. 54 here-in-before but one 06 Amp socket outlet point on same board controlled by one, single pole, one way switch, complete all as specified and directed.

30

-

-

... More
All as per Srl item No. 54 here-in-before but one 16 Amp socket outlet point on independent board controlled 16 Amp switch, complete all as specified and directed.

50

-

-

... More
S&F submain wiring as in repairs with 2 runs of single core 6 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLS copper conductor drawn through and including ISI markes PVC conduit and conduit accessories of medium grade not less than 20mm dia in concealed system including one run of single core 6 sqmm dia FRLS PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one runs of 6 sq.mm copper earth continuity conductor shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly. (iii) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces.

50

-

-

... More
S&F switch piano flush button single pole one way 6 Amp all as specified and directed by Engineer - in – Charge.

385

-

-

... More
S&F regulator electronic stepped heavy duty flush type 230 volt AC, white colour fixed in switch board after cutting necessary chases to required size complete connections all as specified and directed by Engineer-in-Charge.

20

-

-

... More
S & F socket outlet 2 in 1, 3 pin, 6 Amps, flush type all as specified and directed by Engineer-in –Charge.

110

-

-

... More
M&L ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .

180

-

-

... More
M&L Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings all as specified and directed by Engineer - in - Charge .

20

-

-

... More
S&F switch piano flush button single pole one way 16 Amp all as specified and directed by Engineer - in – Charge.

50

-

-

... More
S&F socket outlet 2 in 1, 3 pin, 6 and 16 Amps, flush type complete all as specified and as directed by Engineer-in-Charge.

50

-

-

... More
S & F MCB distribution board of sheet metal triple pole and neutral 4 way, double door, with 200 Amp rated bus bar 240 volt, neutral link and earth link complete including cutting to wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with existing surface all as specified and directed by Engineer-in- Charge.

2

-

-

... More
S & F MCB distribution board of sheet metal single pole and neutral 8 way, double door, with 200 Amp rated bus bar 240 volt, neutral link and earth link complete including cutting to wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with existing surface all as specified and directed by Engineer-in- Charge.

6

-

-

... More
S&F MCB Three Pole and Neutral (TPN) 63 Amps, 415 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.

2

-

-

... More
S&F MCB Single Pole and Neutral (SPN) 40 Amps, 415 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.

6

-

-

... More
S&F MCB Single Pole and Neutral (SPN) 6-32 Amps, 415 Volt, 'C' Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge.

24

-

-

... More
Taking down unserviceable distribution board of any description and making good with cement plaster, putty and paint to match with existing surface all as specified and directed by Engineer-in- Charge.

8

-

-

... More
Supply and fix as in replacement LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5 Sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge.

145

-

-

... More
Supply and fix as in replacement integrated LED batten 9/10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including galvanized earth lead wire 4mm dia by means of GI bolts, nuts, check nuts and washers and connected other end to main board duly protected by GI pipe 15mm bore, medium grade, earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No. 3 of SSR Part – I and connecting to earthing test point, main switch board and testing on completion including CI cover, frame and PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in earthing pit with CI cover and frame including necessary earth works etc, all as specified and directed by Engineer - in – Charge. Note:- 1. PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner.

8

-

-

... More
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades and re-fixing back the same duly cleaned and connecting up including provision of three core, flexible cable of size 0.75 sqmm from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge.

15

-

-

... More
Taking down exhaust fan, sealing cable end, dismantling blades and removing fan and blades and re-fixing back the same duly cleaned and connecting up including provision of three core, flexible cable of size 0.75 sqmm from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
Supply and fix as in replacement of LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed by Engineer-in-Charge.

75

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.