If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Dec 2024
Closing Soon23 Jan 2025
Tender Amount₹ 31,00,000 
Notes
Download

Costs

Summary

Ge I R And D/chd-95/2024-25 Repair And Maintenance Of Central/ Package Type Ac Plants, Cannected Panels/chiller Pipe Lines/air Ducting And Other Connected Work At Chandigarh And Tbrl Range Ramgarh Area Under Ge I R And D Chandigarh

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per serial item no 1.00 above for discharge reed and spring.

4

-

-

... More
All as per serial item no 1.00 above for piston ring set.

4

-

-

... More
All as per serial item no 1.00 above for piston with pin

2

-

-

... More
All as per serial item no 1.00 above for gaskit set

1

-

-

... More
Repair to crank shaft by machining work as required and completed all as specified and directed.

1

-

-

... More
All as per serial item no 8.00 above for main bush -ditto-

3

-

-

... More
All as per serial item no 8.00 above for piston lock -ditto-

12

-

-

... More
All as per serial item no 8.00 above for loading unloading valve coil -ditto-

1

-

-

... More
Overhauling to the unserviceable compressor semi sealed type capacity 16 Ton by opening, dismantling of compressor, necessary machining / mechanical repair work etc and replacement of wornout spare parts for smooth functioning of compressor, reassembling and testing for satisfactory operation all as directed by Engineer-in-Charge. The spare parts & other items required for replacement shall be measured and paid under Sch 'A' item No. 12.00 to 29.00 separately. The spare parts which are not mentioned but are required for smooth and proper functioning / operation of compressor are deemed to include in the unit job. Note :- (Refrigerant gas and compressor oil shall be measured and paid for separately under relevant item of Sch 'A').

1

-

-

... More
Supply only in replacement of following spare parts for compressor semi sealed type capacity 16 Ton for serial Item no 12.00 above Connecting Rods completed all as specified and directed.

6

-

-

... More
All as per serial item no 13.00 above for connecting rods bearing in two half -diito-

6

-

-

... More
All as per serial item no 13.00 above for suction reed and spring -diito-.

6

-

-

... More
All as per serial item no 13.00 above for discharge reed and spring. -diito-

6

-

-

... More
All as per serial item no 13.00 above for piston ring set -diito-

6

-

-

... More
All as per serial item no 13.00 above for piston -diito-

1

-

-

... More
All as per serial item no 13.00 above for pistion pin bush -diito-

3

-

-

... More
All as per serial item no 13.00 above for piston Pin -diito-

6

-

-

... More
All as per serial item no 13.00 above for piston Lock -diito-

12

-

-

... More
All as per serial item no 13.00 above for piston Liner -diito-

1

-

-

... More
All as per serial item no 13.00 above for retaining Plate-diito-

1

-

-

... More
All as per serial item no 13.00 above for discharge Valve Assembly -diito-

2

-

-

... More
All as per serial item no 13.00 above for shaft seal assembly. -diito-

1

-

-

... More
All as per serial item no 13.00 above for gaskit set -diito-

1

-

-

... More
Repair to crankshaft by machining work as required and completed all as specified and directed.

1

-

-

... More
All as per serial item no 27.00 above for ‘O' ring set -ditto-

1

-

-

... More
All as per serial item no 27.00 above for main bush -ditto-

2

-

-

... More
Supply and fixing in replacement following sections/sizes of V-Belt as per existing complete all as specified and directed. A28 Section-A V Belts

8

-

-

... More
All as per serial item no 30.00 above for A32 Section-A V Belts -ditto-

7

-

-

... More
All as per serial item no 30.00 above for B68 Section-B V Belts -ditto-

10

-

-

... More
All as per serial item no 30.00 above for B95 Section-B V Belts -ditto-

20

-

-

... More
All as per serial item no 30.00 above for B118 Section-B V Belts -ditto-

12

-

-

... More
Supply and filling compressor oil complete all as specified and directed.

40

-

-

... More
Supply and fixing in replacement gun metal butterfly valve of 200 mm bore after removing old defective valve and providing necessary aluminium cladding & insulation as per existing complete all as specified and directed.

3

-

-

... More
All as per serial item no. 36.00 above but of bore 150 mm -ditto-

4

-

-

... More
All as per serial item no. 36.00 above but of bore 100 mm -ditto-

4

-

-

... More
All as per serial item no. 36.00 above but of bore 80 mm -ditto-

4

-

-

... More
All as per serial item no. 36.00 above but of bore 65 mm -ditto-

5

-

-

... More
All as per serial item no. 36.00 above but of bore 50 mm -ditto-

5

-

-

... More
Supply and fixing in replacement gun metal gate valves of size 15 mm with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.

5

-

-

... More
All as per serial item no. 42.00 above but of size 20 mm -ditto-

4

-

-

... More
All as per serial item no. 42.00 above but of size 25 mm -ditto-

4

-

-

... More
Supply and fixing in replacement ball brass valves of size 15 mm dia, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.

5

-

-

... More
All as per serial item no 45.00 above but of size 20 mm -ditto-

8

-

-

... More
All as per serial item no 45.00 above but of size 25 mm -ditto-

8

-

-

... More
Material and labour for galvanised iron pipe medium grade of dia 25 mm including all fittings like elbows, bends, nipples, tees, plugs and unions etc. complete for making connections to cooling towers/ condenser or chilled water line for air release/make up water tank etc. complete all as specified and directed.

25

-

-

... More
All as per serial item no. 48.00 above but of dia 20 mm -ditto-

30

-

-

... More
All as per serial item no. 48.00 above but of dia 15 mm -ditto-

25

-

-

... More
Material and labour for laying MS pipe heavy grade of dia 40 mm with all fittings for making connections to cooling towers/ condenser or chilled water line complete all as specified and directed.

24

-

-

... More
Material and labour for laying MS pipe heavy grade of dia 50 mm with all fittings for making connections to cooling towers/ condenser or chilled water line complete all as specified and directed.

30

-

-

... More
Material and labour for laying MS pipe heavy grade of dia 65 mm with all fittings for making connections to cooling towers/ condenser or chilled water line complete all as specified and directed.

30

-

-

... More
Material and labour for laying MS pipe heavy grade of dia 80 mm with all fittings for making connections to cooling towers/ condenser or chilled water line complete all as specified and directed.

24

-

-

... More
Material and labour for taking out / purging of refrigerant gas from the system of A/c plant unit upto 1x 16 TR capacity for carrying out vacuum test by vacuuming the whole A/c plant with the help of vacuum pump and checking the complete system for leakages. Carrying out the pressure test by charging the nitrogen gas in the system and checking of any leakage point , repair / rectification of the same and removing the nitrogen gas from the system and charging of refrigerant gas including charging of additional gas as required and complete all as specified and directed (Note: The arrangement of T&P Nitrogen gas shall be contractors responsibility) Note : Refrigerant gas shall be measured and paid for separately.

10

-

-

... More
Material and labour for taking out / purging of refrigerant gas from the system of A/c plant unit range 1x 25 TR to up to 1x33 TR capacity for carrying out vacuum test by vacuuming the whole A/c plant with the help of vacuum pump and checking the complete system for leakages. Carrying out the pressure test by charging the nitrogen gas in the system and checking of any leakage point , repair / rectification of the same and removing the nitrogen gas from the system and charging of refrigerant gas including charging of additional gas as required and complete all as specified and directed (Note: The arrangement of T&P Nitrogen gas shall be contractors responsibility) Note : Refrigerant gas shall be measured and paid for separately.

11

-

-

... More
Material and labour for taking out / purging of refrigerant gas from the system of A/c plant unit range 1x 66 TR to up to 1x85 TR capacity for carrying out vacuum test by vacuuming the whole A/c plant with the help of vacuum pump and checking the complete system for leakages. Carrying out the pressure test by charging the nitrogen gas in the system and checking of any leakage point , repair / rectification of the same and removing the nitrogen gas from the system and charging of refrigerant gas including charging of additional gas as required and complete all as specified and directed (Note: The arrangement of T&P Nitrogen gas shall be contractors responsibility) Note : Refrigerant gas shall be measured and paid for separately.

7

-

-

... More
Material and labour for taking out / purging of refrigerant gas from the system of VRV/VRF unit of any capacity vacuuming the whole VRV/VRF with the help of vacuum pump and checking the complete system for leakages. Carrying out the pressure test by charging the nitrogen gas in the system and checking of any leakage point , repair / rectification of the same and removing the nitrogen gas from the system and charging of refrigerant gas including charging of additional gas as required and complete all as specified and directed (Note: The arrangement of T&P Nitrogen gas shall be contractors responsibility) Note : Refrigerant gas shall be measured and paid for separately.

4

-

-

... More
Material and labour for charging of refrigerant gas R-410A/R-134A/R-22/R-407C in AC plant complete all as specified and directed.

505

-

-

... More
Material and labour for dismantling unserviceable electric motor AC 3 Phase of capacity 2/3/5/7.5/10 HP and rewinding with super enamelled copper winding wire of existing size and replacing other burnt items including installing and testing complete all as specified and directed. Note:- Copper Winding wire shall be measured and paid for separately under respective Item.

15

-

-

... More
Supply and fixing in replacement super enamelled copper winding wire complete all as specified and directed

65

-

-

... More
Supply and fixing in replacement ball bearing No 6206/6208/6306/6307 complete all as specified and directed

15

-

-

... More
Supply and fixing in replacement ball bearing No 6308/6309/6310 complete all as specified and directed.

15

-

-

... More
Supply and fixing in replacement of cooling fan (PVC) for following rating water pump sets including dismantling of old one complete all as specified and directed.

5

-

-

... More
All as per serial item no 64.00 above for size 7.5 HP / 10 HP -ditto-

5

-

-

... More
Repair and overhauling to air handling unit of central AC Plants, dismantling of Air filters and cleaning the cooling coil with chemical and refixing the air filter after cleaning and testing and greasing the bearing of blower shaft etc complete all as specified and directed for the following AC Plant AHUs :-

1

-

-

... More
Air handling unit of 2x25 Ton Central AC plant at Spark Range, Zone-I

1

-

-

... More
All as per serial item no 66.00 above but air handling unit of 3x33 Ton Central AC plant at Instrument Bldg, Zone-I -ditto-

3

-

-

... More
All as per serial item no 66.00 above but Air handling unit of 3x25 Ton Central AC plant at DEC Bldg, Zone-I -ditto-

2

-

-

... More
All as per serial item no 66.00 above but Air handling unit of 3x16 Ton Central AC plant at ETF Vibration Bldg -ditto-

5

-

-

... More
All as per serial item no 66.00 above but Air handling unit of 5x66 Ton Central AC plant at AAG Zone -ditto-

1

-

-

... More
All as per serial item no 66.00 above but Air handling unit of 4x12.5 Ton Central AC plant at Old RTRS, Zone – VIII -ditto-

1

-

-

... More
All as per serial item no 66.00 above but Air handling unit of 3x13 Ton Central AC plant at Zone -III -ditto-

1

-

-

... More
Repair and overhauling to air handling unit of Central AC Plants, dismantling of Air filters and cleaning the cooling coil with chemical and refixing the air filter after cleaning and testing and greasing the bearing of blower shaft etc complete all as specified and directed for the following AC Plant AHUs :-

1

-

-

... More
Air handling unit no.1 of 3x12.9 KW and 1x15.3KW VRV VRF type Central AC plant at EMI building ETF

1

-

-

... More
All as per serial item no 74.00 above but Air handling unit no.2 of 3x12.9 KW and 1x15.3KW VRV VRF type Central AC plant at EMI building ETF -ditto-

2

-

-

... More
All as per serial item no 74.00 above but Air handling unit of 2x85 Ton Central AC plant at EMC Bldg, ETF -ditto-

2

-

-

... More
Servicing of cassette type/ hi wall split type indoor units of cap 1.28/2.0/3.18/1.5/2.0 TR installed at high pulse bldg Zone-IV from OEM/ Authorised dealer of OEM complete all as specified and directed

11

-

-

... More
Supply and fixing in replacement of suction/discharge oil pressure gauge / water pressure gauge of size 100 mm dia with pressure range 0-150 PSI/ 0-300 PSI complete all as specified and directed.

25

-

-

... More
Overhauling to FRP cooling towers by draining the water, cleaning the scales and dirt, washing the PVC fills by opening and dismantling the CT fan , replacing the damaged fills with new ones, re-assembling and testing complete all as specified and directed Note : New PVC fills shall be measured and paid as Supply and fix in replacement separately under respective item of schedule.

10

-

-

... More
Supply and fixing in replacement of PVC fills blocks for FRP cooling tower complete all as specified and directed.

155

-

-

... More
Descaling of each condenser of Central AC plant, dismantling of existing water pipe line , filling the descaling compound (Chemical RXSOL-41-8865-025) in condenser, flushing out the same after 24 Hours, cleaning the condenser tubes with water by using nylon brush with rod to remove the scaling complete all as specified and directed for the following AC Plants 2x25 Ton Central AC plant at Spark Range, Zone-I

2

-

-

... More
All as per serial item no 82.00 above but 3x33 Ton Central AC plant at Instrument Bldg,Zone-I -ditto-

3

-

-

... More
All as per serial item no 82.00 above but 3x16 Ton Central AC plant at ETF Vibration Bldg -ditto-

3

-

-

... More
All as per serial item no 82.00 above but 5x66 Ton Central AC plant at AAG Zone -ditto-

15

-

-

... More
All as per serial item no 82.00 above but 3x25 Ton Central AC plant at Zone -II -ditto-

3

-

-

... More
All as per serial item no 82.00 above but 3x13 Ton Central AC plant at Zone -III -ditto-

3

-

-

... More
All as per serial item no 82.00 above but 3x12.5 Ton Central AC plant at Old RTRS, Zone-VIII -ditto-

3

-

-

... More
All as per serial item no 82.00 above but 3x25 Ton Central AC plant at DEC Bldg Zone -I -ditto-

3

-

-

... More
Cleaning of fins type air cooled condensing unit of Package type AC Plant with caustic soda , after that flushing /cleaning the condenser coil and fins with water by using nylon brush to remove the dirt and scale complete all as specified and directed for the following AC plants 2x11 Ton Package Type AC plant at PFC Bldg , SWS Complex

2

-

-

... More
All as per serial item no 90.00 above but 1x11 Ton Package type AC Plant at Project Office Bldg, SWS Complex and 2x11 Ton Package type AC Plant at Zone-VII -ditto-

3

-

-

... More
All as per serial item no 90.00 above but 2x5.5 Ton Package Type AC plant at Zone V -ditto-

2

-

-

... More
All as per serial item no 90.00 above but 4x16.5 Ton Package Type AC plant at Auditorium Zone I -ditto-

4

-

-

... More
All as per serial item no 90.00 above but 3x8.75 Ton Package Type AC plant at Workshop Zone I -ditto-

3

-

-

... More
All as per serial item no 90.00 above but 4x8.5 Ton Package Type AC plant at Auditorium, SASE, Sec-37, Chandigarh -ditto-

4

-

-

... More
Servicing of outdoor unit of VRV/VRF AC Plant from OEM / Authorised dealer of OEM, cleaning the condeser coil and fins with water by using nylon brush to remove the dirt and scale complete all as specified and directed for the following AC plants 6x12.9 KW VRV/VRF unit at EMI building ETF

6

-

-

... More
All as per serial item no 96.00 above but 2x15.3 KW VRV/VRF unit at EMI building ETF -ditto-

2

-

-

... More
All as per serial item no 96.00 above but 2x 18 HP VRV/VRF unit at CADS bldg zone-I -ditto-

2

-

-

... More
All as per serial item no 96.00 above but 20 HP VRV/VRF unit at High Pulse bldg zone-IV -ditto-

1

-

-

... More
Supply and fixing in replacement display controller complete unit of package type /Central type AC Plants of various Capacity complete all as specified and directed.

2

-

-

... More
Supply and fixing in replacement HP/LP pressure cut out switch complete all as specified and directed.

15

-

-

... More
Supply and fixing in replacement Water Flow switch 220 V AC 10 Amps for Condenser/Chilled Water complete all as specified and directed.

8

-

-

... More
Supply and fixing in replacement finned strip heater having terminal at one end and two holes at another end for installation, 240 volt, 3 KW complete all as specified and directed.

20

-

-

... More
Supply and fixing in replacement finned strip heater having terminal at one end and two holes at another end for installation, 240 volt, 2 KW complete all as specified and directed.

15

-

-

... More
Supply and fixing in replacement finned strip heater having terminal at one end and two holes at another end for installation, 240 volt, 1.5 KW complete all as specified and directed.

6

-

-

... More
Material and labour for preparation of old painted surfaces of MS / GI pipe line of condenser and chilled water and applying two coats of synthetic enamel paint on steel/iron surfaces complete all as specified and directed.

25

-

-

... More
Material and labour for preparation of old painted surfaces of condenser water/chilled water monoblock pump sets of capacity upto 10 HP and applying two coats of synthetic enamel paint on steel/iron surfaces complete all as specified and directed.

8

-

-

... More
Material and labour for preparation of old painted surfaces of control panels of AC Plants of any capacity and applying two coats of synthetic enamel paint on steel/iron surfaces complete all as specified and directed.

5

-

-

... More
Material and labour for preparation of old painted surfaces of Chiller/Package unit including condensers/ condenser fan assembly, compressors, frames, valves etc. of any capacity and applying two coats of synthetic enamel paint on steel/iron surfaces complete all as specified and directed.

8

-

-

... More
Supply and fixing in replacement Fan assembly with blade for FRP Cooling towers as per sample of approved make complete all as specified and directed

4

-

-

... More
Supply and fixing in replacement Syphon with cock complete all as specified and directed

10

-

-

... More
Supply and fixing in replacement Industrial type thermometer complete all as specified and directed.

15

-

-

... More
Supply, install, testing and commissioning of Hermetically sealed Scroll Compressor of capacity 11.00 Ton compatible with R22 refrigerant gas , suitable for Water cooled AC Plant complete all as specified and directed.

3

-

-

... More
Supply, install, testing and commissioning of Hermetically sealed Scroll Compressor of capacity 8.5 Ton compatible with R22 refrigerant gas , suitable for Ductable AC complete all as specified and directed.

1

-

-

... More
Supply, install, testing and commissioning of Hermetically sealed Scroll Compressor of capacity 5.5 Ton 3 phase 440 Volts compatible with R22 refrigerant gas , suitable for Ductable AC complete all as specified and directed.

3

-

-

... More
Supply ,installation ,testing and commissioning of centrifugal monoblock type pumping set i.e chiller water pump having discharge capacity minimum 500 LPM at 45 mtr head coupled with electric motor 3 phase, 415 volt ,50 Hz of suitable capacity (approx 10 HP or above) to drive pump delivering water up to 45 m head and suction del pipe size 100mmx100mm ,mounted on common MS base frame including pcc foundation, nut, bolts etc all as specified and directed. Modal no-KDS -1030+ , make -kirlosakr

2

-

-

... More
Supply, replacing, commissioning and testing of mono block water pump set electric driven 415 volt 1450 RPM (approx cap 7.5 HP or above) ,Kirloskar model no FEF42/XV-1004 suitable for existing suction/discharge 400 LPM and not less than 30mtr head suitable for condenser water complete all as specified and directed.

1

-

-

... More
Material and labour for Insulation of M S Pipe with PUF slab 30 mm thick with 50 mm dia and including applying bituminous compound and Aluminium cladding with 26 gauge Aluminium sheet for MS pipes of following dia complete all as specified and directed:

50

-

-

... More
All as per serial item no 118.00 above but size 65 mm dia -ditto-

80

-

-

... More
Supply and fixing for Display Board for electric shock treatment chart/ Maintenance Chart/ Description Chart of size 850x600 mm made out of CRCA sheet 2 mm thick with square pipe 35 mmx35 mm fixed around sheet by welding and making hanging arrangements on top of the board. Board shall be painted with two coats of stove enamelled paint (navy Blue) over a coat of red oxide primer and writing the detail with fluorescent reflective tape (as per sample) by digital computerized printing style complete all as specified and directed.

5

-

-

... More
Supply and fixing for synthetic insulating rubber mat of size 2 metre x 1 metre x 19 mm (ISI Marked) suitable for control panels of AC Plants complete all as specified and directed.

5

-

-

... More
Supply and fixing in repair MCCB rating 100 Amps, 4 pole, 415 volts breaking capacity 16 KA complete all as specified and directed.

4

-

-

... More
Supply and fixing in repair MCCB rating 125 Amps, 4 pole, 415 volts breaking capacity 16 KA complete all as specified and directed.

4

-

-

... More
Supply and fixing in repair MCCB rating 200 Amps, 3 pole, 415 volts breaking capacity 36 KA complete all as specified and directed.

3

-

-

... More
Supply and fixing in repair MCCB rating 250 Amps, 3 pole, 415 volts breaking capacity 36 KA complete all as specified and directed.

4

-

-

... More
Supply and fixing in repair MCB TPN rating 40 Amps, 4 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and directed.

6

-

-

... More
Supply and fixing in repair MCB TPN rating 63 Amps, 4 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and directed.

8

-

-

... More
Supply and fixing in repair MCB TP rating 40 Amps, 3 pole, C-type, 415 volts breaking capacity 10 KA complete all as specified and directed.

7

-

-

... More
Supply and fixing in repair MCB SP rating 6-32 Amps, single pole, 240 volts complete all as specified and directed.

15

-

-

... More
Supply and fixing in repair MCB SPN rating 40 amps, single pole neutral, 240 volts complete all as specified and directed.

12

-

-

... More
Taking out old unserviceable power/auxiliary contactor from control panel / starter and supply and fix new power contactor of following size and capacity complete all as specified and directed. Power contactors of AC3 rating 12 Amps MNX type Complete all as specified and as directed.

20

-

-

... More
Power contactors AC3 rating 22 Amps ML type complete all as specified and directed.

12

-

-

... More
Power contactors AC3 rating 32-40 Amps ML type complete all as specified and directed.

10

-

-

... More
Taking out old unserviceable Timer switches from LT panel / starter and supply and fix new Timer Switches timer switch range 0 to 60 second complete all as specified and directed.

12

-

-

... More
Supply and fixing in replacement selector switch for volt meter/ Amp Meter complete all as specified and directed.

12

-

-

... More
Supply and fixing in replacement of terminal block connector complete all as specified and directed.

15

-

-

... More
Supply and fixing in replacement phase failure relay with fixed under & over voltage cut out complete all as specified and directed .

20

-

-

... More
Supply and fixing in replacement Digital Volt Meter, complete all as specified and directed.

8

-

-

... More
Supply and fixing in replacement Digital Ampere Meter, complete all as specified and directed.

8

-

-

... More
Supply and fixing in replacement single phase preventor complete all as specified and directed.

15

-

-

... More
Supply and fixing in replacement On / Off push button with lense complete all as specified and directed.

20

-

-

... More
Supply and fixing in replacement compressor motor protector relay 22 A,240V reset delay 30 min + 5 min complete all as specified and directed

5

-

-

... More
Supply and fixing in replacement time delay relay range 0-30 Sec complete all as specified and directed.

15

-

-

... More
Supply and fixing in replacement temperature control switch complete all as specified and directed.

6

-

-

... More
Supply and fixing in replacement indicating light universal complete all as specified and directed.

5

-

-

... More
Supply and fixing in replacement toggle switch 15 Amps complete all as specified and directed.

21

-

-

... More
Supply and fixing in replacement thermostat for heating control range 0-30 degree centigrade complete all as specified and directed.

15

-

-

... More
Material and labour for painting to existing AC installations sign board of size 1.2 metre x 1.0 metre with two coats of synthetic enamel paint approved colour over a coat of primer and writing letters in 4 inches sizes and colours as required including scrapping out old rusted paints complete all as specified and directed.

6

-

-

... More
Overhauling/Servicing of voltage stabilizer of capacity 15 KVA/20 KVA 3 phase by checking of PCB plate, main transformer, control transformer, servo motor, Dimmer and resistance port etc and making necessary adjustment by replacing screw, lugs, shouldering of loose connection, wiring etc. Complete all as specified and directed. ( Spare parts shall be measured and paid for separately under respective items )

4

-

-

... More
Supply and fixing in replacement PCB complete all as specified and directed.

4

-

-

... More
Supply and fxing in replacement digital volt meter square type 0 to 300 volt complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement Servo motor 220 volt 3 Kg torque, 60 RPM complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement resistance port complete all as specified and directed.

4

-

-

... More
Supply and fixing in replacement control transformer complete all as specified and directed.

2

-

-

... More
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6.0mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore light grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and directed all as shown in electrical plate No. 5 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost . (Note: GI strip & GI pipe beyond 7.5Mtr length from earth electrode shall be measured and paid for separately).

4

-

-

... More
Material and labour for earth continuity conductor size 32x6 mm galvanized iron strip complete all as specified and directed

15

-

-

... More
Supply and fixing for rotational moulded polyethylene water storage tank of storage capacity 1000 Litres (cylindrical vertical with closed top) hoisted and fixed in position including fixing of inlet and outlet pipes, flaot valves and other necessary accessories complete all as specified and directed

2

-

-

... More
Supply and fixing for chicken wire mesh of medium SS material , Hexagonal weave type, fine finish suitable for cooling tower protection including all necessary nuts, bolts, screws, washers etc. complete all as specified and directed

50

-

-

... More
Material and labour for insulation of MS Chilled water Pipes of any size with Class 'O' Nitrile Sheet of thickness 25 mm having factory evaporated aluminium foil using suitable adhesive of approved make and sealing all the longitudinal joints and circular overlaps with suitable ALP tapes 50 mm x 3 mm complete all as specified and directed

45

-

-

... More
Supply and fixing in replacement 50 mm thick washable type pre-filters with filter element made out of synthetic non-woven media supported by HDPE mesh on both side including stitching in diamond pattern complete including frame, suitable for efficiency 90% down to 10 micron EU-3 Type sample with mounting frame work. complete all as specified and directed

21

-

-

... More
Supply and fixing in replacement Solenoid coil AMG type 120-240 volts complete all as specified and directed.

12

-

-

... More
Material and labour for repair of PCB of control panels of Chilling Units/Package Units/VRV VRF unit of any capacity including checking the components, replacing damaged components with new ones, making the PCB fully functional till Engineer-in-Charge's satisfaction complete all as specified and directed.

10

-

-

... More
Taking out old unserviceable thermal overload relay from LT Panel/Control Panel/Starter and Supply and Fix new thermal overload relays ML Type of any range as per existing complete all as specified and directed.

20

-

-

... More
Supply, install, testing and commissioning of sealed unit compressor of Cap 1.5 Ton after taking down defective compressor from foundation and making connection with suction/discharge of the AC capacity 1.5 Ton complete all as specified and directed.

3

-

-

... More
Supply and fixing in replacement of refrigerant dryer filter of various size/capacity as per sample for water cooled central AC plant complete all as specified and directed

11

-

-

... More
Supply and fixing in replacement of refrigerant dryer filter of various size/capacity as per sample for Package type AC plant complete all as specified and directed.

10

-

-

... More
Taking out old u/s chiller water sensor of any size/cap and supply and fixing of new chiller water sensor as per sample complete all as specified and directed.

4

-

-

... More
Supply, programme, testing & commissioning of AC drive, 5.5kW ,V/F control, input 3- phase, 415Volt, AC, output 3phase, 415Volt, AC for control AHU motor of VRV/VRF AC plant and chiller plant complete all as specified and directed.

2

-

-

... More
Supply, programme , testing & commissioning of AC drive, 2.2kW ,V/F control, input 3- phase, 415Volt, AC, output 3phase, 415Volt, AC for control AHU motor of VRV/VRF AC plant and chiller plant complete all as specified and directed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.