Military Engineer Services Tender

If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date22 Dec 2024
Closing Soon25 Dec 2024
Tender Amount₹ 29,66,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Suppy only of moving contact block complete suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Suppy only of mechanical castle interlock assembly with key suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Suppy only of closing coil assembly 230 volts AC/ 24 volts DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

14

-

-

... More
Suppy only of Tripping coil with plunger assembly 230 volts AC/24V DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

13

-

-

... More
Suppy only of closing coil plunger with 24 volts DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

14

-

-

... More
Suppy only of spout bushing suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

13

-

-

... More
Suppy only of Canister Assembly suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Suppy only of HT 11 KV PT HRC Fuse suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Suppy only of HT 33 KV PT HRC Fuse suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Suppy only of Vacuum interrupter suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Suppy only of trip push button suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Suppy only of spring charged indicator suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply only of digital type AC Ammeter 3 phase, CT ratio 150/5, HT meter flush mounted type with suitable selector switch of size 96 mm x 96 mm, accuracy class 1.0, CT type complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply only of digital type AC Voltmeter, flush mounted type 3 phase, HT meter, 50Hz, Voltage range 0- 12 KV Volt of size 96mm x 96mm accuracy class 1.0 with suitable selector switch complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply only of push button with NO/ NC contact suitable for capacitor panel complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply only of 11 KV resin cast epoxy type current transformers (CTs) of ratio 100-50/5-5 Amps and class accuracy 0.5/5P10 or as per existing capacity including testing complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply only of electronic relay for HT breaker operating voltage 240 V AC/ DC, 50/60 Hz with adjustable settings Model No. L / MiCOM P-111 of Schneider or equivalent including cutting drilling to fix relay in existing panel door as per site requirement complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Suppy only of shunt trip coil 24 to 30 volts DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Suppy only of motor and gear assembly 110 volts AC/24V DC suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Suppy only of TNC switch of capacity 25 Amp, 2NO + 2NC with barrel lock suitable for VCB 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

7

-

-

... More
Suppy only of isolating contact assembly suitable for Vacuum Circuit Breaker 11 KV of capacity 400/630/800 Amps complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Suppy only of Sealed Maintenance free/ valve - regulated Lead-Acid Battery 2 Volt 100 AH, rechargeable type, complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Supply only of Battery Charger copper wound of with input voltage 180 to 270 Volt, of 50 AH Battery charger 24 volt DC, float voltage 27 volt DC, Boost voltage 28 to 30 Volt DC rated currect 20 Amp, suitable for battery bank 24 volts 20 Amp with auto cut of, complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply only of Power pack with battery backup 24 Volt DC & connected to HT PT secondary circuit including testing for triping complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Suppy only of under voltage trip device (UVT) for VCB 11KV of capacity 400/630/800Amps complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Supply only of Multi Function Meter LCD Display with Parameters - Amp, Volt, Freq, PF, RPM, %Load, %Unbal, Amp phase angle, Maximum Demand with RS-485 including necessary wiring required at site, complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Material and labour for servicing of battery bank installed at 11 KV sub stations by opening top cover, checking of batteries, cleaning of terminals and top up distilled water complete and checking meters making serviceable 110V/ 100AH battery charger installed in 11KV sub station complete all as specified and directed by Engr-in-Charge. Note :- Cost of distilled water, grease, terminals, wire etc. shall deemed to be inclusive in the quoted rates.

1

-

-

... More
Material and labour for repairing/ servicing, calibrating / testing /setting of fault tripping and recommissioning complete as mentioned in maintance and operation manual of 11 KV HT RMU SF6 breaker of 400/630 Amps opening front cabinets and de-carbonizing moving and fixed contacts, lubricating, inspecting the wiring of Micro processor Earth Fault and Over Current relays, tripping coil electrical, indication systems, metering systems and checking for manual/auto tripping system, meggaring all the contacts with replacement of complete wiring with existing size copper cable conductor and colour coding and all as per directed by Engr-in-Charge. Note : (i) SF6 Gas charging will be measured and paid seperately. (ii) Repairing, servicing, testing & calibration shall be carried out through OEM certified or other expert agency and test report/ certificate shall be submitted by contractor to Engr-in-Charge before claiming payment for the item. (iii) Cost of small spares like gasket, battery, O ring nuts, bolts and lubricants / dust cleaning required for servicing of RMU is deemed to be included in the quoted rate. However, major spares, if replaced shall be measured and paid separately under respective items as "Supply Only". Labour cost for replacement of such parts shall deemed to be included in the quoted rate. (iv) Job of repairing/ servicing/calibrating / testing /setting of fault tripping and recommissioning has been considered for complete set of RMU"s i.e 1 way/2way/3 way/ 4 way/6 way and of various makes as per respective location. Contractor is advised to take cognizance of the fact and may visit the respective sites with prior approval of concerned Engr-in-Charge. No claim whatsoever shall be entertained during currency of work.

18

-

-

... More
Supply only of Actuator motor for operating mechanism charging motor ON/OFF for all type of Ring main unit SF-6 of capacity 11 kV, 400/630 Amps complete all as specified and directed by Engr-in-Charge.

8

-

-

... More
Supply only of plug in voltage presence indicator system 3 Phase (VPIS) type WIM for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Supply only of fuse assembly by opening fuse canisters of RMU positioned behind interlocking cover for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps complete all as specified and directed by Engr-in-Charge.

4

-

-

... More
Supply only of Bushing assembly for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of complete all as specified and directed by Engr-in-Charge.

14

-

-

... More
Supply only of terminal contact piece with silicone coupling by opening the terminal cover for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply only of gear assembly grooved inside and outside for operating of Ring Main Unit SF-6 of capacity 11 KV, 630 Amps complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Supply only of Operating Handle for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps complete all as specified and directed by Engr-in-Charge.

9

-

-

... More
Supply only of SF-6 gas in safe ring/ safe plus by SF-6 gas bottle by removing front cover and on screw manometer and reduction valve and maintained the pressure 14 bar obslute for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps of complete all as specified and directed by Engr-in-Charge.

30

-

-

... More
Supply only of Trifurcation boot 11 KV capacity for cable termination joint of RMU incoming and outgoing terminals including taking out old defective trifurcation boot for Ring Main Unit SF-6 of capacity 11 KV, 630 Amps complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Supply and fixing of HT/LT cable route indicator made out of round CI embossed plate 100 mm dia 6 mm thick duly riveted with angle of size 40 x 40 x 6 mm and 60 cm long with and including PCC for embedding 1:4:8 type D-2 of size 30cmx30cmx30cm including dismantling of old route indicator complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Material and labour for fault detection by bringing fault detector machine with skilled tradesmen to detect the fault at site in the high potential HT cable of any sizes, marking the place of fault detection and digging up in soft/ loose soil for showing the fault and re-filling earth after repairs and requisite cable protection complete all specified and as directed by Engr-in-Charge. Note :- Fault dector machine and operator shall be arranged by the contractor. Quoted rate shall deemed to be inclusive of all necessary earth work, relaying of bricks/ PCC cable cover, procuring & laying coarse sand for cushioning of HT cables. However, cable joint shall be measured and paid separately.

20

-

-

... More
Material and labour for preparation of old painted surface of steel by brushing and painting with spray painting one coat with metallic paint to HT VCB Panel and marking / lettering of SM/ MES Number complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Material and labour for replacement and pasting of Electrical Insulating Mat ( 2m x 1m x 25mm) thick made out of Dielectric 'Elastomer' which possess elastic properties and may be natural or synthetic in nature. Should have working voltage - 11 KV, No tear or breakage due to trolley movement & foot traffic, resistant to acids, alkalis, solvent and transformer oil, pasteable type can be easily pasted/Installed on floor, water and moisture proof, complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply and fixing in replacement of electronic siren horizontal single stage continuous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of +5 DB 500 mtrs range complete all as specified and directed by Engr-in-Charge.

1

-

-

... More
Supply and fixing in repairs of Copper lugs for heavy duty cable of size of 50 sqmm 3 core cable complete all as specified and directed by Engr-in-Charge.

18

-

-

... More
Supply and fixing in repairs of Copper lugs for heavy duty cable of size of 95 sqmm 3 core cable complete all as specified and directed by Engr-in-Charge.

20

-

-

... More
Supply and fixing in repairs of Copper lugs for heavy duty cable of size of 120 sqmm 3 core cable complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Supply and fixing in repairs of Copper lugs for heavy duty cable of size of 185 sqmm 3 core cable complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
Taking out carefully HT electric cables of any size alongwith PCC cable covers, GI pipes etc. from tenches, ducts, poles etc. after taking shut down of HT electric supply and disconnecting all electric connections from the main HT Panel, transformer etc., keeping aside for repairs/ removal from site complete all as specified and directed by Engr-in-Charge. Note :- Earth work, sand cushioning and cable protection shall be measured and paid separately.

450

-

-

... More
Material and labour in replacement of Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 25 x4mm as earth lead up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1 using 20mm gradede stone aggregates,40mm thick precast RCC cover in 1:2:4 reinforced with expanded metal (weight not less than 4 kg/sqm), and frame of angle iron 25x25x6mm with lugs 02 nos with 6mm dia MS bar handle made to shape, excavation and earth work in any type of soil and including medium grade GI watering pipe 20mm bore with funnel and wire mesh and medium grade GI earth wire protection pipe 40mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I, connected to earthing testing point and testing on completion complete all as specified and directed by Engr-in-Charge.

16

-

-

... More
Material and labour for disconnecting of all HT/ Earthing/ AC/ DC connections of existing VCB 11 KV carefully and shifting the VCB for making good of ducts with all accessories to the another location at Air Force Station Sirsa including Jhopra and making all HT/ Earthing/ AC/ DC connections and testing complete all as specified and directed by Engr-in-Charge. Note:- (i) If any damage occurred of VCB during shifting of VCB 11 KV then contractor will be responsible for repair of VCB without any extra cost with original materials of OEM. (ii) Vehicle, T & P and labour for lifting and transportation of VCBs shall be provided by contractor under his own arrangement.

10

-

-

... More
Material and labour in repairs for 1.2 m x 1.8 m flex board and drawing of substation schematic diagram using standard drafting tool Auto CAD. One set of drawing shall be submitted to the Deptt for scrutiny of drawing and final prints of drawing shall be submitted thereafter complete all as specified and directed by Engr-in-Charge. This item includes the under mentioned scope of work:- (i) Preparation of drawing of Substation schematic diagram using standard drafting tools Auto CAD. (ii) Duly printed Flex board with MS frame of size 1.2 m x 1.8 m and other fixing accessories. (iii) Submission of soft copy.

14

-

-

... More
Supply and fixing in repairs for LED Board for 33 KV substation of size 5.5 x 2.2 x .8 m with suitable embedded letters, written as per decided by Engr-in-Charge including all kind of fitting/ Angle iron/ Struture/ PCC Work and electrical connections required on ground complete all as specified and directed.

2

-

-

... More
Material and labour in replacement of Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
Material and labour in replacement of Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-in-Charge.

24

-

-

... More
Supply and fixing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured (Earthed), electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 Sqmm 3 core complete all as specified and directed by Engr-in-Charge.

400

-

-

... More
Relaying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables, 11 KV grade with stranded aluminium conductor cable of any size laid in trench or fixed to wall/ passing through pipe/ pole after fault rectification including necessary aluminium thimbles, jointing and testing complete all as specified and as directed by Engineer-in-Charge. Note :- Necessary earth work, cushioning and cable protection shall be measured and paid separately under respective items.

50

-

-

... More
Excavation in trenches not exc 1.5 m wide and not exceeding 1.5 m depth for foundation, laying of cables etc and getting out in soft loose soil complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Returning filling including spreading leveling watering and well ramming in layers not exc 25 cm in soil completed all as specified and directed by Engineer-in-Charge.

76

-

-

... More
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point as in soil complete all as specified and directed by Engineer-in-Charge.

24

-

-

... More
Material and labour for sand cushioning (dry) in trenches/ducts for protection of UG cables( below, above and around the UG cable laid) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable ) and cosolidated ( punned) up to 180mm thickness complete all as specified and as directed by Engineer-in-Charge. Note :- Punned thickness of sand cushioning will be measured, for the payment purpose.

24

-

-

... More
Material and labour for replacement of supply and laying un-reinforced precast concrete cable cover, class HV, type 1, flat, size 300mm x 180mm x 40mm complete all as specified and directed by Engineer-in-Charge.

460

-

-

... More
Re-laying of serviceable PCC cable covers obtained from taking out of HT cables, laid perpendicular to the cable for cable protection complete all as specified and directed by Engineer-in-Charge.

1200

-

-

... More
Supply, fabricating, installation, testing, commissioning and electrically connecting HT bus bar Feeder Pillar of size 100cm x 110cm x 65 cm, 11KV, fabricated in a CPRI approved factory, machine pressed, dust and vermin proof, out door type made with CRCA sheet 3.15 mm thick, HT Feeder Pillar internally and externally shall be painted with expoxy powder coating RED paint with 7 tank process for treatment of degreasing, pickling & two coats primer, before being given the stove epoxy finish, both side opening in two halfes with rubber beading, including Copper bus bar of 630 Amp (Each Strip Size 50 x 8mm x Length 800 ) capacity, 4 strip mounted on HT porcelain insulators, HT Danger Plate provided on Both Side, bus bar chamber and shall be provided with inspection covers, Cubical switch shall have the independent opening panel and shall be mounted on angle iron frame and legs made from angle iron of size 50mm x 50mm x 6mm frame including lifting arrangement and legs duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer, embeding and grouting in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate in foundation including necessay earth work , including all connections / control wiring incoming / outgoing with suitable size of PVC insulated copper conductor cable of 1100 / 650 volt grade comprising, Cable enter with Cable Glands and following accessories including dismantling of existing old feeder pillar/ bus bar chamber and removal from site complete all as specified and as directed by Engr-in-Charge.

6

-

-

... More
Supply and fixing in repairs of Maximum demand controller includes Input voltage measurement range 50-520 VAC (P-P) CT/PT site programmable Accuracy Class 1.0, 0.5 SAux supply 80-300 VAC/DC Time of Day (TOD) 6 slots available CT secondary site selectable 1A / 5ABlock/sliding window site selectable Flush mounting 96 x 96 mm• 4 relay outputs for Max demand controller Running demand, max demand, prediction demand in single page window Datalog (8MB) Parameters:- V, A, F, kW, KVA, kVAr, kWh, kVAh,kVArh, PF, Runhr, Onhr, Intr, Phaseangle, THD, Events, Neutral current, Max Demand (with RTC) complete all as specified and as directed by Engr-in-Charge. Make : L&T Model No WC6000 or equivalent model in Schneider/ Siemens/ CG.

19

-

-

... More
Supply and fixing in repairs including caliberation of VCB ‘CGI 14N’ Numerical Protection Relay is a fully digital relay based on microprocessor technology with analogue to digital conversion of the measured values and subsequent numerical processing. It uses a specialized digital signal processor (DSP) as the computational hardware, alongwith associated software. The relay has feature of IDMT as well as instantaneous protection for both over current & earth elements with breaker failure protection (50BF). The relay can be field programmed as 3O/C + 1E/F or 2 O/C + 1E/F + 1SE/F or 1RE/F (optional) or SE/F (Definite Time Function only). The front panel features a 6-button keypad & a 16×2 LCD display that provides an easy user interface complete all as specified and as directed by Engr-in-Charge.

19

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.