Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Building Construction
Eprocure
Opening Date4 Oct 2022
Closing Date1 Nov 2022
Tender Amount₹ 33,58,494 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for 75mm thick Cement concrete type B2 1:2:4 ushing 40 mm graded stone aggregate) laid in alternate panel for floor, path and harstanding all as specified and directed by Engr-in-Charge.

600

-

-

... More
M&L for 25mm thick Wearproof topping using metallic floor hardener as per manfacutre's instruction, as specified (incorporating an approved metallic floor hardner), laid on concrete floors and pavings and path, and finished even and smooth complete all as specified and directed by Engr-in-Charge. (Note: metallic hardender and glass dividing strips shall be measured and paid separately under respective items of Schedule).

600

-

-

... More
Supply only metallic floor hardener complete all as per manufacturer instruction and all as directed by Engr-in-Charge.

720

-

-

... More
Supply only 22 mm wide and 3 mm thick glass dividing strips as laid in floor complete all as specified and directed by Engr-in-Charge.

810

-

-

... More
M&L for Brick work with sub class B bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engr-in-Charge.

35

-

-

... More
S&F polyester powder coated aluminium fixed partition medium weight aluminium section as Horizontal members size 63.5x38.10mm at 0.75 Kg/M C/C spacing shall not exceed 900mm Vertical member size 63.5x38.10 mm at 0.75 K/M C/C spacing shall not be more than 900 MM. Bottom portion -3' height portion, pre laminated board 12mm thick including necesary clips, rubbers beading aluminium beading and fixing to the adjoining/ existing wall/partition etc with all necessary fitting/ fixtures etc complete all as specified by Engr-in-Charge. Make JINDAL/ HINDAL/ INDALCO Note:- Glass, prelaminated board to be paid and measured separately under appropriate item of sch A)

35

-

-

... More
M&L, for 12 mm thick pre-laminated particle board, exterior grade, pre-laminated on both side with decorative choice laminations fixed between aluminium section with and including snap fitting aluminium clips of polyester powder coated along with the glass with rubber gasket, complete all as specified and directed by Engr-in-Charge. Make. Anchor/Kitply/Novapan or equivalent out of make specified in 'List of Make'.

14

-

-

... More
S&F in repair 4 mm thick tinted glass of selected quality fixed to aluminium frame of any section as in item here-in-before incl snal fit aluminium clips of polyester powder coated along the glass with rubber gasket complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
Excavating in post holes soft/ loose soil (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.

66

-

-

... More
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed by Engr-in-Charge.

3050

-

-

... More
M&L for MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engr-in-Charge.

320

-

-

... More
S&F 1mm mild steel, plain black sheet hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; waters tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed.

6

-

-

... More
M&L for Pressed steel frames 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed all as specified and directed by Engr-in-Charge.

10

-

-

... More
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and complete all as specified and directed by Engr-in-Charge.

155

-

-

... More
M&L for plain cement concrete in foundation filling and mass concrete Type E2 1:5:10 (40mm graded aggregate) all as specified and direected by Engr-in-Charge

2.8

-

-

... More
M&L preparation new steel surface exc 10 cm width/girth one coat red oxide primer and two coat synthetic enamal paint all as specified and directed.

74

-

-

... More
M&L for 75mm thick Cement concrete type D2 1:4 :8 (40mm graded stone aggregate) as in sub base finished even smooth with broom finished w/o using extra cement, laid in alternate bay all as directed by Engr-in-charge.

678

-

-

... More
M&L 60 mm Machine pressed pre casted pressed cement concrete inter locking paver blocks glazed coloured up to 6mm on the top in any shape and size, strenth not less than M-35 including 25mm thick sand cushioning complete all as specified and directed.

678

-

-

... More
S&F 2mm thick Linoleum covering, plain coloured, laid dry in floors including stretching, cutting and fitting complete all as specified and directed.

749

-

-

... More
Surface dressing not exc 15 cm deep in soft/loose soil complete all as specified and directed.

220

-

-

... More
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.

72

-

-

... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.

124

-

-

... More
M&L for PCC 1:4:8, type D-2, using 40mm graded stone aggregate, as in fdn filling and mass concrete complete all as specified and directed.

4

-

-

... More
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces complete all as specified and directed.

52

-

-

... More
M&L for RCC A-1 (nominal mix) 1:1.5:3, using 20mm graded stone aggregate, as in footing, plinth beams and col base complete all as specified and directed.

9

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.

54

-

-

... More
Filling under floor, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.

52

-

-

... More
M&L for 100mm thick PCC 1:4:8 type D-2 using 20mm graded stone aggregate as in sub base to floor or ramp complete all as specified and directed.

42

-

-

... More
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc with rough finished surfaces complete all as specified and directed.

42

-

-

... More
M&L for Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed.

14

-

-

... More
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick rough finished complete all as specified and directed.

68

-

-

... More
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide with rough finish surfaces complete all as specified.

80

-

-

... More
M&L for RCC type A-1 (nominal mix) 1:1.5:3, using 20mm graded stone aggregate, as in columns complete all as specified and directed.

6

-

-

... More
M&L for RCC type A-1 (nominal mix) 1:1.5:3, using 20mm graded stone aggregate, as in beams and lintels upto 1.50 mtr span complete all as specified and directed

6

-

-

... More
M&L for RCC type A-1 (nominal mix) 1:1.5:3, using 20mm graded stone aggregate, as chajjas and similar works complete all as specified.

1.5

-

-

... More
M&L for RCC type A-1 (nominal mix) 1:1.5:3, using 20mm graded stone aggregate, as roof slab and similar works complete all as specified and directed.

5.5

-

-

... More
M&L for Rendering 15 mm thick, on fair faces of brick work or concrete surfaces, in cement mortar 1:6 and finished even and smooth without using extra cement, complete all as specified and directed.

145

-

-

... More
M&L for Rendering 15 mm thick in cement mortar 1:4 by mixing integral waer proofing compound & finished even & smooth without using extra cement complete all as specified and directed. WPC measured and paid seprately.

230

-

-

... More
M&L for Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling finished even & smooth without using extra cement complete all as specified and directed. (Note:- WPC measured and paid seprately under respective item of Schedule).

50

-

-

... More
M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing ,complete all as specified and directed

65

-

-

... More
M&L for Machine cut kota stone skirting 20-25mm thick over and including 10mm thick rendering in CM 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing , complete all as specified and directed

7

-

-

... More
M&L for 75mm thick PCC 1:2:4 type B-1 using 20mm graded aggregate flooring on ramp finished even and smooth without using extra cement with XPM empression, complete all as specified and directed.

5.76

-

-

... More
M&L for Rendering 10 mm thick, screed layer on concrete surfaces of roof, in cement mortar 1:4 and finished even and smooth without using extra cement, complete all as specified and directed.

35

-

-

... More
M&L water proofing treatment of roof consisting as under:- (a) Applying evenly a coat of bituminous primer conforming to IS-3384:1986 @ 0.30 litre/sqm including preparation of roof surfaces (b) Applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg/Sqm on plaster surface all as specified. (c) A layer of 3mm thick APP polymeric membrane of weight not less than 3.60 kg/sqm, reinforced with polyester non-woven fabric (weight not less than 160gm/sqm), duly sealed at over laps & joints with end laps of the 10cm and side over laps of 7.5cm by flame (by torch application) all as per manufacturer’s instructions, complete all as specified and directed.

35

-

-

... More
M&L Appling one coat Bitumen water proofing aluminium heat resistance paint on the roof as per manufacture instructions complete all as specified and directed by Engr-in-Charge. Make : PLASCON or equivalent as approved .

35

-

-

... More
M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement over and including 15mm thick cement screed in CM 1:6 complete all as specified and directed.

65

-

-

... More
M&L for PCC 1:2:4 type B-0 using 12.50mm graded aggregate as in mud stop or golla to chajjas, hold fast etc complete all as specified and directed.

0.5

-

-

... More
M&L for Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.

9

-

-

... More
M&L for 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.

13

-

-

... More
M&L for 50mm thick plain cement concrete 1:2:4, Type B-1, using 20 mm graded stone aggregate, laid in 1:20 slope as in plinth protection including making joints at 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot down bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement, complete all as specified and directed.

55

-

-

... More
Preparing New Plastered Surfaces of WALLS and applying TWO COATS of DISTEMPER OIL EMULSION (OIL BOUND WASHABLE DISTEMPER) over a Coat of 1mm thick wall care putty, complete all as specified and as directed. by Engineer-in-Charge. (Note:- work will be strictly executed by mechinised means/ tools as required for smart periodical services)

145

-

-

... More
M&L for preparation of new plastered ceiling surfaces and applying 3 coats of white wash, complete all as specified and directed.

50

-

-

... More
M&L new plastered surface applying two coat of weather proof exterior grade over one coat of primer and two coat of JK/Birla Cement putty cement base putty all as specified and directed by Engineer-in-Charge

175

-

-

... More
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.

3.4

-

-

... More
M&L fo Mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending etc and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.

1200

-

-

... More
M&L fo Mild steel TMT bars 8 to 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending etc and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.

430

-

-

... More
M&L fo Mild steel TMT bars 8 cut to length, bent to shape required, including cranking, bending etc and binding with and including mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.

370

-

-

... More
S & F in repair Asbestos cement sheet corrugated or semi corrugated 6mm thick fixed with L or J type GI hook bolts complete all as specified and directed by Engr -in -charge

55

-

-

... More
M&L plain cement concrete (1:3:6), type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.

6.7

-

-

... More
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level complete all as specified and as directed.

5

-

-

... More
M&L for 75mm thick PCC 1:2:4 type C 2 using 40graded stone aggregate as in sub base complete all as specified and as directed.

50

-

-

... More
M&L for 40mm thick PCC 1:2:4 type C2 using 20graded stone aggregate as in floor complete all as specified and directed.

50

-

-

... More
S&F Welded steel wire fabric exc 4 Kg/ Sqm welded to steel section at any position complete all as specified and directed.

60

-

-

... More
S & F structural steel work Fe-410-W(Gde-E-250) quality-B as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.

90

-

-

... More
Supply & Fix Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end tobe fillted with washers and one hexagonal or square nut , exc 22.5cm and n exc 30cm long dia of shank 16 to 20mm complete all as specified and as directed.

10

-

-

... More
Removing excavated material to a distance exc. 50 metre but n.exc. 250 metre and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed.

51.7

-

-

... More
S &F Mild steel sliding door bolts 200mm,plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.

1

-

-

... More
S &F Butt hinges 100mm (ISI marked) length heavy weight, cold rolled mild steel, and fixed complete all as specified and as directed.

4

-

-

... More
Supplying and installation double side writing informatory stainless steel reflective sign board following size having with aluminum composit panel sheet base of 3mm thickness fixed with self tapping & Coach screw having retro reflective tape base and font. Colour and matter of sign board will be furnished by Engr-in-Charge. The frame of sign board should be 50mm outer dia round/square of Stainless steel pipe 16 gauge and having 2 legs of stain less steel round pipe 2.75mtr to 3.00 mtr various height each of 75mm outer dia round pipe, sutable doom on both side including taking down of existing sign board complete all as specofied and as directed. (Note:- Rate for writing letter both side shall deemed to be included in this item and nothing extra shall paid to contractor for writing letter.)

-

-

-

... More
SS Sign board of size 5'x5',

8

-

-

... More
SS Sign board of size 5'x4',

8

-

-

... More
SS Sign board of size 4'x3',

8

-

-

... More
SS Sign board of size 2'x2'

8

-

-

... More
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:4 complete all as specified and directed by Engr-in-Charge.

15

-

-

... More
Extra for forming fair finished drain or channel30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.

70

-

-

... More
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in copings complete all as specified and directed.

0.8

-

-

... More
E/M PORTION

-

-

-

... More
M&L for point wiring complete with 1.5 Sqmm (nominal area) PVC insulated, multi stranded, FRLS copper conductor cable unsheathed in and including PVC conduit with all fittings medium grade ISI Marked and PVC insulated FRLS copper conductor cable of size 1.5 sq mm as earth wire, connected to common earth dolly suitable for mounting modular switches including modular metal flush boxes and modular face plate complete all as specified and as directed by Engr-in-charge, (The works includes cutting of chasis and making good disturbed surfaces and rate deemed to included in quated rate):-

-

-

-

... More
One light point/ fan point controlled by one way modular switch

4

-

-

... More
One exhaust fan point controlled by one way modular switch

1

-

-

... More
M&L sub main wiring along with earth wire of size 2x 4Sqmm and 1x 4Sqmm earth continuity conductor and connected to earth dolly, PVC insulated single core multi stranded copper conductor cable in PVC conduit of adequate width and length with all accessories and fiiting like bends, elbow etc all as specified and directed by Engr-in-Charge. Note:- Cutting and refixing the surface alongwith matching the surface with existing paint.

45

-

-

... More
Supply & fix modular switch 1way 6A,1 module complete all as specified and directed.

3

-

-

... More
Supply & fix LED tube light along with fixture, 20 W complete all as specified and directed.

2

-

-

... More
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed. Note:- Rate quoted for items includes cost of all civil work like cutting to wall ceiling, floor, filling with PCC, finishing the surfaces with existing to match etc.

1

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core complete all as specified and directed.

20

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size10 sq mm 2 core complete all as specified and directed.

250

-

-

... More
S&F wiring for circuit/submain wiring alongwith earth wire with 2x 4Sqmm Phase wire +1x 4Sqmm for earth wire of FRLSH in steel enamelled conduit PVC insulated copper conductor, single core cable in surface/ recessed as required complete all as specified and directed.

30

-

-

... More
Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable siz complete all as specified and directed. Make: Sudhir/Shyam / Bajaj / Crompton / Flexipro or equivalent as approved in MES in any command.

2

-

-

... More
S&F flame proof exhaust fan 350mm as specified and directed by engr- in -charge, Make: Sudhir/Shyam / Bajaj / Crompton / Flexipro or equivalent as approved in MES in any command.

1

-

-

... More
M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecified and directed by Engr-in-Charge.

20

-

-

... More
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete as sepecified and directed by Engr-in-Charge.

1.8

-

-

... More
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.

3

-

-

... More
M&L for Earthing complete with galvanised GI earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 2009 or directed by Engineer-in-charge.

5

-

-

... More
Supply and fix sheet metal enclosures single door for DB's when MCBs to be used single pole & neutral 4way with 200 Amps rated bus bar complete all specified and directed.

2

-

-

... More
S&F MCB SPN 240V 40 amps complete all as specified and directed.

2

-

-

... More
S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10KA 6-32 Amps as specified

4

-

-

... More
Supply, install,commissioning and testing Invertor type 5 star rated air cooled split unit air conditioner electric driven single phase of capacity 2 TR,Eco friendly refrigerant, hi wall split units indoor and outdoor unit complete with cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with 5 star rated, auto restart facility, 100 % copper tube and condenser , including excess copper tubing if required beyond the length supplied with AC unit and PVC conduit of 15mm dia not exceeding 2.5 mtr long for water drain and making good to disturbed surface with cement mortar ratio of 1:3 and testing complete all as specified and directed by Engineer-in-charge. Make :Voltas Model No 4502863 -245V ADZ or equivalent in Blue star, Hitachi, Daikin. Note:- (i) Rate quoted for items includes cost of all civil work like cutting to wall ceiling, floor, filling with PCC, finishing the surfaces with existing to match etc, if required for installation of AC unit as directed. (ii) Required copper pipes for installtion shall be deemed to be included in the quoted rates

1

-

-

... More
S&F 2AC Controller timer with temperature ECO-2020 model , LCD Display for Air conditioner system wth following technical specification:- 1. Supply Voltage: 230 V AC, 50 Hz ± 15% . 2. Contact Rating: 30 A at 230 V AC for Compressor or AC Outputs. 3. 5 A at 250 V AC for Alarm Potential Free Outputs (C,N/O). 4. Temperature Sensor: Thermistor Sensor NTC 10K@25°C. 5. Size: 235 mm (H) X 190 mm (W) X 63 mm (D). 6. Metal Body with Wall Mounting. 7. Sensor Cable Length: 1.5 meters. 8. Temperature Sensing Range: 0.0°C to 55.0 °C.

1

-

-

... More
M&L complete for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of pipe for protection of cable etc by means of bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.

6

-

-

... More
Supply, fixing and laying GI tube medium grade 50 mm bore including all necessary fitting laid in trenches or on wall complete all as specified and directed.

10

-

-

... More
Supply and fixing LED light fitting 1x120 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed by Engr-In-Charge. Make: Sudhir/Shyam / Bajaj / Crompton / Flexipro or equivalent as approved in MES in any command.

6

-

-

... More
M&L Earth continuity conductor or main earthing lead 25x3 mm Aluminium Strip size, fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.

20

-

-

... More
Supply & fix Air Circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting all as specified and directed by Engr-in-charge

3

-

-

... More
Note:- The amount of Rs NIL against Schedule of Credit on Page No NIL shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.