Haryana Vidyut Prasaran Nigam Limited Tender
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.
Costs
EMD
₹ 10,13,000Document Cost
₹ 11,800Tender Fee
₹ 1,180
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_HBC_193636_1Bid Award Id
ViewTender No
NIT No 31 PD and CTender Authority
Haryana Vidyut Prasaran Nigam Limited ViewPurchaser Address
-Website
http://http://www.hvpn.org.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
+ 6 mtr. extn. Only
2
-
-
132 KV D/C “DB” Tower KRR Design
8
-
-
+ 3 mtr. extn. Only
3
-
-
+ 6 mtr extn. only
3
-
-
132 KV D/C “DC” Tower KRR Design
5
-
-
+ 3 mtr extn. only
1
-
-
+ 6 mtr extn. only
2
-
-
132 KV D/C “DD” Tower KRR Design
12
-
-
+ 3 mtr extn. only
4
-
-
+15 mtr. Extn. Only
2
-
-
Extra cross arm only (set of 3)
3
-
-
132KV D/C Gantry
4
-
-
Supply of earthing of towers
(i) Pipe type
34
-
-
Supply of following tower accessories
Danger plate
34
-
-
Number plate
34
-
-
Phase plate (set of 3)
29
-
-
Circuit plate
34
-
-
Bird guard (set of 3)
5
-
-
Anti climbing device
34
-
-
Line Material
Conductor (ACSR panther 0.2 conductor (approx.)
19.5
-
-
132 KV Silicon Rubber Polymer Insulator String
70 KN
39
-
-
90 KN
186
-
-
132KV Post Insulators
12
-
-
Hardware fittings single ‘I’ suspension string
15
-
-
Single suspension pilot String
24
-
-
Single tension string
174
-
-
Double tension string
6
-
-
Conductor accessories Mid span compressive joint for panther conductor
13
-
-
Repair sleeves for panther conductor
4
-
-
Vibration damper for panther conductor
390
-
-
OPGW (24 Fiber) (DWSM, G.652D)
22
-
-
Hardware Set for above 24 OPGW Fiber Optic including all cable fitting & accessories except joint box
22
-
-
Joint Box 24 Fiber OPGW to OPGW (as applicable)
8
-
-
Joint Box 24 Fiber OPGW to FOAC (as applicable)
2
-
-
FODP 48F: Indoor type, rack mounted with FCPC Coupling and pig tails (5mtrs, each) as applicable for (132KV S/Stn. Naultha end, Panipat Co-op Sugar mill end)
3
-
-
Fiber Optic Approach Cable, 24 fiber (DWSM) along with PLB HPE Ducts of suitable size & strength and all accessories (132KV S/Stn. Naultha end, Panipat Co-op Sugar mill end)
1
-
-
Telecom Equipment for Panipat Co-op Sugar mill end, 220KV S/Stn. Samalkha end SDH Equipment (STM - 16 MADM upto 5 MSP protected directions)
Base Equipment (Common cards, Cross connect/control cards, optical base cards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc. fully equipped excluding
2
-
-
Optical Interface Cards/SFP :
L16.2 SFP (The quantities will be decided at the time of detailed engineering)
4
-
-
S4.1 SFP (The quantities will be decided at the time of detailed engineering)
4
-
-
Tributary cards:
E1 Interface card (Min. 32 interfaces per card)
4
-
-
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
4
-
-
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
2
-
-
Equipment Cabinet with DDF and all installation accessories
2
-
-
Network Manager System - Craft Terminal:
Hardware
1
-
-
Software
1
-
-
VOIP telephone instrument with one common switch (min. 8 port) compatible with SLDC
1
-
-
Integration of the Equipment with existing network (Note:- Above Quantities (from sr. no.19 to 25) covers the requirement of remote station as well. If the equipment for remote end is already available then the same for remote end is not required. )
1
-
-
Mandatory Spares Telecom Equipment Optical Interface Cards/SFP:
L16.2 SFP
2
-
-
S4.1 SFP
2
-
-
Tributary cards
E1 Interface card ( Min. 32 interfaces per card)
1
-
-
Ethernet Interface 10/100 Base T with Layer-2 switching (Min. 8 interfaces per card)
1
-
-
Gigabit Ethernet (Layer 2) Interface (min. 2 nos.)
1
-
-
Pre Connectorized Optical Patch Cards (10Mtrs.) – Pack of six Patch Cards
1
-
-
Detailed Survey
6.38
-
-
Furnishing bore log data
7
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
132kV D/C 'DA' type Tower (KRR Design) classified as - Wet (w/out de-watering)
5
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. 132kV D/C 'DB' type Tower (KRR Design) classified as - Wet (w/out de-watering)
8
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
132kV D/C 'DC' type Tower (KRR Design) classified as - Wet (w/out de-watering)
5
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 0 to 6Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
132kV D/C 'DD' type Tower (KRR Design) classified as - Dry
1
-
-
- Wet (w/out de-watering)
9
-
-
Construction of tower foundations as per HVPNL Drgs& Specs for 9 to 25Mtr. extn. including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect. i) 132kV D/C 'DD+15m extn.' type Tower (KRR Design) classified as - Wet (w/out de-watering)
2
-
-
Construction of 132kV D/C gantry foundation as per KRR Design one set consist of T-1 & T-2 (3 no. footings in one set ) including excavation, concreting, supply and placement of steel reinforcement and backfilling complete in all respect.
4
-
-
Dewatering of subsoil water for lowering of water table to enable excavation of earth, concreting for foundations/stub and backfilling, by boring of tube wells or deploying well point system so that continuous lowering of water table is made till completion of work, without disturbing the soil characteristics. The rate shall include all type of expenditure for required dewatering arrangements and irrespective of type of tower including extensions if any i.e. KRR design or TATA design.
1
-
-
Protection Measure Brick masonry in 1:4 cement sand mortar including excavation
2
-
-
Earth filling, compaction, leveling etc inside revetments
2
-
-
M-20 (1:1½ :3 mix) concrete for top seal cover, for revetment etc.
1
-
-
Lean concrete (1:4:8)
1
-
-
RCC 1:1.5:3 (M20) including all material, labour, excavation, cutting and placing of steel, centering & shuttering, concreting etc. complete in all respect.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements