Western Railway Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Western Railway - WR Tender

Works
Civil And Construction
Telecommunication Services
Consultancy Services
Civil And Architectural Services
Ireps
Opening Date9 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 18,42,37,121.05 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Failure Analysis System or Central Monitoring Unit with Printer. As per technical 5 specification IRS: S-992006 (Amdt-3) or latest. The specification of Failure Analysis System should be got approved from the Engineer in charge before supply. The Specification of Failure Analysis System shall be as per technical specification given in contract Agreement or higher version as approved by Engineer In-Charge. (Technical specification shall be provided in tender documents.)

2

260015

520030

... More
Failure Analysis & Fault Diagnostic software for data logger of 1024 digital inputs /4096 digital inputs

48244

2

96488

... More
750 VA Off line UPS with battery backup 3 Hours for Failure Analysis System of reputed make as per Engineer in-charge

2

25117

50234

... More
Provision of T-Networking/Dual card E1 to Serial Port (RS-232) convertor suitable to insert in the data logger / FEP euro rack for Networking to the Data Logger equipments. This includes supply of all equipment/ accessories required for the purpose.

4

31203

124812

... More
Pyrotech Workspace make New Modular Control Desk size 4102x2576 mm for provision 9 of 02 Nos. Monitors made in "XLAT" system. 1. Table Top: The material of the working surface shall be made of thermally treated Aluminum -Trihydrate and acrylic resin material supported on minimum 25 mm thick MDF base. 2. Structure: Powder Coated Aluminum Sturdy Structure and extreme side Aesthetic Legs. The structure shall be rigid enough to withstand BIFMA X5.5: 2014 (Latest Edition). 3. Monitor Arm:- UL certified monitor arm assembly shall have auto lock, push & remove feature for quick release of VESA mounts and modular arm extensions for ease in maintenance and fixing of monitor by one technician within 30 seconds without using any tools. 4. Shutters & Side Legs: - Front and back shutters shall be of18 mm Laminated MDF Board with premium finish Side leg.

1

966052

966052.64

... More
Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, 1 capacitors, insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.)

14

27067

378938

... More
Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with 2 fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated.

10

25044

250440

... More
PVC insulated Railway Signalling multi-core Indoor Cable 60core x 0.6mm Dia conforming to IRS:76/89 (Amd3) or latest

1

152409

152409

... More
PVC insulated Railway Signaling multi-core Indoor Cable 1 mm x 40 mm x 0.6mm Dia conforming toIRS:76/89(Amd3) or latest.

1

100669

100669

... More
PVC insulated Railway Signaling multi-core Indoor Cable 1mm x 24 mm x 1 mm Dia conforming to IRS:76/89(Amd3) or latest.

1

167295

167295

... More
Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3) or latest.

4

5569

22276

... More
Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm.( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89 or latest.

4

40222

160888

... More
Flexible cable (Power wire), multi-strand copper conductors cross section 8 (1x16Sq.mm).101 Conductors each diameter 0.45 +/- 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89 or latest.

2

118721

237442

... More
Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments.

-

-

485290

... More
Earth Leakage Detector as per RDSO/SPN/256/2002 or latest with latest amendments. 10 The basic detector unit shall comprise of 12 channels, for use on signaling circuits of 110V AC/DC and/or 60V/24V/12V DC as ordered by purchaser. If the detector is required for less number of channels, dummy plates shall be provided. For additional requirement add on /expendable cabinet may be used. The voltage specified shall be provided with + 25% and - 10% tolerance.

6

155843

935058

... More
Fuse auto changeover system for use in Railway Signaling System as per 11 RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signaling circuits. The system shall have 8 cards with a monitoring arrangement of 4 fuses in one card.

18

537210

537210

... More
Fuse auto changeover system for use in Railway Signaling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprises 24 nos. of external Non-Deteriorating Type or 'G' type fuses from 4 Amp to 10 Amp capacities which are in signaling circuits. The system shall have 6 cards with a monitoring arrangement of 4 fuses in one card

4

203584

203584

... More
Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 13 75/2006 with the latest amendment. The fuse block shall be suitable for round-head type voltage fuses. This also includes the supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92.

150

143

21450

... More
Round head type non detoriating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with2A/4A/6A capacity.

50

58

2900

... More
ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.

3500

89

311500

... More
"Colour Light Signal Complete. This includes: - (1). Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). (2). CI Base (As per IRS S-10 & RDSO Drg. 16 No. 2011/M with latest assembly). (3). Pinnacle. (4). Ladder Assembly, as per RDSO Drg. No. SA- 23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder. (5). Signal Front Staging Complete Assembly for CLS Unit. (6). Signal back staging as per extent WR Practice Note: Height of the Post shall be 4.6 m Long. "

54

10863

586602

... More
Non Metallic (FRP) color light signal housing multi-unit type for railway signaling 17 suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

18

26540

477720

... More
Non Metallic (FRP) color light signal housing multi-unit type for railway signaling 18 suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

36

30287

1090332

... More
Non Metallic (FRP) color light signal housing multi-unit type for railway signalling 19 suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO Drg.No. SA 23001/A/M Adv. Alt- Sand as per SPEC. No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.

2

29817

59634

... More
Junction route indicator unit 1way as per Drg. No. RDSO SA 23401 suitable for LED Signal Lighting Unit & as IRS: S-66/84 amndt-1or latest. (Supply of LED Unit is not covered in this item).

2

19449

38898

... More
Junction route indicator unit 2 way as per Drg. No. RDSO SA 23402 is suitable for LED Signal Lighting Units & as IRS: S-66/84 amndt-1 or latest.

4

19535

78140

... More
Junction route indicator unit 3 ways as per Drg. No. RDSO SA 23403 is suitable for LED Signal Lighting Units & as IRS: S-66/84 amndt-1 or latest. (Supply of LED Units is not covered in this item).

2

23181

46362

... More
Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm 23 Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item).

12

4541

54492

... More
Position Light Shunt Signal Unit Complete, with offset bracket, hood, Cover etc. as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item).

4

3273

13092

... More
Calling ON Signal Unit with Brackets & Fixing accessories. Calling On Signal Unit shall conform to RDSO Drg no 24351(Adv.) Alt1 suitable to LED Signal Lighting Unit.

8

2670

21360

... More
Offset brackets for Main Signal, made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R

-

-

26

... More
Miniature, Plug in Type, M to C,DC Neutral ,Track relay, ACI, Style QTA2, 9 Ohm, 2F-1B contact, Code - FGHKX Spec : BRS :939-A & 966 (Appx-F2) & IRS : S-23, S-23,S-34 & 60.

32

4770

152640

... More
Miniature, Plug in type, M to C, AC immunized, DC biased Track Relay, 2F-2B contacts, style QBAT-9 ohms. Code ABEJX Spec:- RDSO/SPN/84 Ver. 2 : IRS -S@ 45"44@IRS-S-23, IRS-S@ 45<45@ 78.

12

6318

75816

... More
Track feed battery chargers, 110V AC input, 2 to 6/10 V DC Output; as per Specn. No. IRS.S 89/ 2013 with latest amendments. Charger shall be suitable for charging 80 AH battery.

75

3985

298875

... More
Adjustable Track Feed Resistance disc type 30 ohms as per RDSO Drg. No. SA 20166/M (Adv.) with latest amendments (with Phenolic molded base).

75

1392

104400

... More
Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass/SMC/FRP along with terminal blocks.

450

1699

764550

... More
Low maintenance Lead acid secondary cell 2V/80 AH (Track feed Battery), shelf mounting type conforming to IRS:S- 88/2004 or latest (uncharged). 33

150

2255

338250

... More
GI wire 8 SWG (4mm Dia) suitable for track circuit rail bonding.

4

67

268

... More
Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M.

200

6

1200

... More
Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments.

150

3813

571950

... More
Hydrometer, Exide make or similar for measuring the specific gravity of Battery Graded acid with mounting stand in location Boxes.

4

271

1084

... More
"Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the 37 following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer."

180

1889

340020

... More
Medium Class G.I. Pipes to IS: 1239 (Pt.)-2004 or latest; 100mm dia. (int. Dia) 3.65 mm thick or above with coupling. G.I. pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. pipes.

200

759

151800

... More
Desk type Electronic Magneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments.

6

6191

37146

... More
Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008. 41

80

15225

1218000

... More
Earth Electrode as per Drg. No. CSTE / 6091.

50

3452

172600

... More
SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/948 dt. 26.04.2011 (Single app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply

30

74764

2242920

... More
SS Location box made of Spl Grade SS 304 of size as per Drg. No. DRM/SG/945 dtd 03.03.2011 (Half app. Case) or latest. Manufacturer's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply

-

-

43

... More
Pad locks Godrej make, Hardened NavTal 7 lever, 65mm Dia with common key or similar product having same feature & technical data. 45

40

145

5800

... More
Supply of Standard Tools set as per Annexure.

1

37074

37074

... More
Office Revolving Chair Godrej Make Model No.9u02r Bravo Or Similar of reputed brand will be specified by Engineer in-charge

1

8361

8361

... More
Office Chair makes Godrej CH-7B or similar of reputed brand will be specified by Engineer in-charge.

2

2784

5568

... More
Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 or Similar of reputed brand will be specified by Engineer in-charge.

1

15550

15550

... More
Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand will be specified by Engineer in-charge.

1

17010

17010

... More
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split-Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement). 51

22

1376

30272

... More
PPTC fuse 12V GP 16-400 (2A) for TF/TR circuit, make Raychem, Epcos, Siemens. 52

150

11

1650

... More
PPTC fuse 24V GP 30-110 (1.4A) for Q series Relay (TPR). 53

60

11

660

... More
PPTC fuse 110V AC for Track Charger GP 250-185 (1.4A)

60

11

660

... More
Supply Polyolefin cab le channel o f s i z e w idth 240/340 mm, he ight 155/230 54 internal/external, length 1meter produced o f polyolefin with fire protection class K-1 in accordance with DIN 53438 Part-II for laying signaling/telecom cables, channel attachable to each other with male female swallow tail connectors and having a suitable detachable cover, as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications.

4500

1936

8712000

... More
Miniature, Plug-in type, Tractive Armature, Universal AC lamp proving relay, Style QECX, 4F-4B Contact, for 110 V AC LED 56

80

5674

453920

... More
Time Element Relay (Clock work type) AG timer Siemens Make (No RSSK 30/0052).

8

6395

51160

... More
Miniature, Plug-in type, DC Neutral Line Relay, 24V DC 1000 Ohm , ACI Style- QNA1K, 6F-6B/4F-4B Contact

110

6444

708840

... More
"Miniature, Plug-in Type, DC Neutral Line, Non AC Immunized Relay, Style QN1, 24 V DC, 8F-8B/12F- 4BContact, Code ABCDF/ABCDE Spec: BRS: 930; IRS S@10"59@ IRS S 23."

10

4159

41590

... More
Key Lock Relay working on 24V DC, AC immunize with different ward combinations (Three ward plates to be supplied with each relay). Key ward shall be specified by engineer incharge as per requirement.

10

9733

97330

... More
Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar).

50

56

2800

... More
Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A. (System, Rapid, Malnad or RBCO make or similar).

50

19

950

... More
Electrically Operated Lifting Barrier complete set suitable for 110VDC/24V DC supply with hand generator back up & motorized b o o m locking arrangements a s p e r RDSO Spec. SPN/208/2012 with the latest amendment. One set consisting of 02 No.s of Barriers of length 09.76 Mtr. along with Spares & tool kit mentioned in RDSO Spec. SPN/208/2012 clause 10.1 & 10.2. 63

4

488187

1952748

... More
Road warning Flasher kit for LC gate as per circuit design

4

1759

7036

... More
Dual tone bell/buzzer with flasher arrangement 25W horn, (Make of any ISI approved firm) working voltage as per circuit design

8

7206

57648

... More
Supply and Installation of Domino based Gate Panel size 12x 8 dominos as per drawing supplied by Engg .In charge

2

12222

24444

... More
Supply of Battery Charger self-regulating floor mounting type with 230V AC single phase input and output 24 V DC, 20A to specn. IRS-S- 86/2000 with latest amendment for Axle counter application. (Amdt. 4).

8

33312

266496

... More
Supply of Remote Terminal Unit (RTU) with 128 digital input &16 analog input as per 67 technical specification IRS: S-99 2006(Amdt-3) or latest. In addition RTU should have dual leased line modem. It should possible to connect RTU up to 12 Kms from main data logger. This includes rack for installation &Battery backup for 06 hrs.(Inspection by RDSO)

4

129348

517392

... More
Program switches, snap action, base mounting type along with acrylic cover and mounting bracket, 25A, 9 poles, and 3 positions make Siemens / Thakur or Similar.

13

12996

168948

... More
MS Sliding type mechanical Boom barrier assembly 11 to 12 Meter Long, movement drive mechanism, resetting & supporting stand suitable for Mechanical/ Electrical level crossing gate as an emergency arrangement as per Drg.

4

164636

658544

... More
Standard Tool kits, Test and Measuring instruments required for Installation, testing, commissioning & maintenance of HASSDAC. Kit will includes all tools & measuring instruments as per ANNEXURE (Annexure shall be attached with CA).

2

115640

231280

... More
"Supply o f Tools Kit for Digital Axle Counter (Multi section/Single section). (MSDAC comply to the RDSO spec. No. RDSO/SPN/176/2013/Ver.3 or latest and manufacturer's specification and SSDAC comply to the RDSO/SPN/177/2012,Ver.3 or latest respectively). The tool kit shall be minimum 71 equipped with the following equipments: (i) All mechanical tools shall be of reputed make like Taparia/Bosch etc. (ii) Digital multimeter true RMS type of make Fluke 189 or similar reputed make with probe set - 1 No. (iii) Adjustable torque wrenches 25-135 N/mtr with 13 mm and 19 mm inserts- 1 set (iv) Set of spanners screw drivers and soldering iron - 1 set (v) Dummy wheel - 1 No. (vi) Marking Jig - 1 No. (vii) Adapter card - 1 No. (viii) Extended wired socket to interface with diag No. stic plug - 1 No. (viii) Selector switch on panel base - 1 No. (ix) DAC EC card puller etc."

2

144043

288086.8

... More
Supply o f self supported aluminum flat step ladder (conforming t o ISI) 5 ft . height. Ladder should be self- supported and it should be made up of rust proof Aluminum of Min 16 SWG. No plastic hinges/Step support should be used.

10

3089

30899

... More
Supply of Smart Cabinet/Rack for Housing of Various S&T equipments like KLCR, Reset 73 Box, IPS Indication Panel, CA VA Unit for FACS, SP AU for Point Reversal, Crank Handle, Quad Cable Earth Sensing Unit along with Fixing of KLCR (KLCR will be provided by Railway) as per instruction of Site Engineer, Make RITTAL, SANTEL, VERO , PRESIDENT, APC Schneider or similar reputed make.

2

58030

116061.54

... More
Miniature 'E' type lock complete with keys as per RDSO Drg. No. SA 3473, 3373 & spec. IRS(S) 30/64. Ward to be specified by Engineer - in - charge. 75

10

2081

20815.2

... More
Supply of Fiber/ SMC/FRP/RCC Earth Chamber.

12

649

7788

... More
IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8 77

8

5388

43109.36

... More
Rubber Mat for Power Equipment room. (5mm thick).

50

121

6081.5

... More
Supply o f in-built GNSS based cable route tracer with 10W, 500mA, 85V transmitter suitable for detecting & mapping underground cables with accuracy which can up to 3-5 cm or better, 78 with current direction up/down arrows, Remote calibration check feature. Supply shall include inbuilt RTK enabled receiver, transmitter, compatible dual Bluetooth android phone with RTK mobile application pre- installed in android device along with minimum 5 years subscription, compatible with NTRIP andRTCMv3.X messaging standards and holder & standard accessories. Make/Model: Radio detection RD8200GS or similar.

1

1387100

1387100

... More
Supply of CAT-6 cable. 1 Box= 305 mtr DAX, Nortal,Amp,Molexor Lucent make with identification mark /ferrules ect..

305

19

5795

... More
Maintance stool for relay room & battery room as per drg no. DY/CSTE/C/ADI/SUNR/ PIPAVAV GC /1. 3

2

2386

4772

... More
Panel Cum Block Instrument Table as per site Engineer-in charge.

2

36143

72286

... More
25 mm PVC conduit pipe with minimum 2 mm Thickness AS PER IS:9537(PART-3) OR LATESTWITH ISI making, each of length 3 meters. The material should be supplied from OEM/ Authorized dealer only

150

25

3750

... More
Low Maintenance Lead acid Stationary Secondary Cells for S&T installations 2 Volt 200 AH as per spec. IRS:S- 88/2004 with latest amendments.

4

36649

146596

... More
"Electronic LC gate Telephone system with voice logger facility as per RDSO Spec No 6 RDSO/SPN/TC/51/2021 (Rev 1.0) or latest consist of one master Telephone, 06 slave Telephones with modified surge protection & Line connecting unit and 24 Volt DC power supply unit with MF battery compatible with existing electronic LC Gate Telephone system. FIRM's OFFER: MAKE/BRAND- Bentron Power Systems"

2

76136

152272

... More
Automatic Media changeover of Modems working on redundant channels for data transmission on OFC / Quad / Microwave Radio. 8

2

32202

64404

... More
Modem for UFSBI (for use with secondary media OFC/Quad) 9

2

57610

115220

... More
Supply of Axle counter cable conductor's Earth resistance Sensing unit.

2

34856

69712

... More
Supply of Modem (E1-RS232) compatible with existing UFSBI system to work on backup 10 media OFC (via unframed E1-2 mbps from STM interface).working voltage: 24 VDC(+/-20%),& operating temperature:-10 deg. C to +70 deg. C. the modem shall be compatible withUFSBI/existing block system as per RDSO Spec IRS S:105/2012 or latest.

8

23538

188304

... More
Silane siloxine Alithatic Urethane resin Blend solvent Based high technology Membrane 11 Radiant Heat reflecting insulating thermal barrier coating with a Genuine product sticker when removed display "VOID" on each container as per attached technical Specifications. Firms Offer : Same as above. make / Brand : CYPRUSS

10

5144

51440

... More
Supply of one Quad VF 2T Transformer joint assembly of VF transformers 1120:470. IRS:TC 22/2021 ver1.1 13

8

1171

9368

... More
Half Round RCC pipes & collars of 300 mm internal dia (1+1 meter long)

250

608

152000

... More
Half Round RCC pipes & collars of 150 mm internal dia (1+1 meter long) along with collars as per IS No. 458/2003 of NP type

1800

319

574200

... More
Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied.

50

5056

252800

... More
Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 20 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied.

-

-

16

... More
Supply of BIS listed semi automatic stainless steel fire extinguisher with UL approved 17 clean gas with auto manual reverse stainless steel valve 'NASA 200 MAR' having capacity of 02 Kgs and made of stainless steel 304 grade with Indian railways logo on each unit for camping coaches. Detailed specification attached in the annexure.ACCEPTED MAKE BRAND :NASA 200 MAR 18

5

27815

139075

... More
Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) 19

10

2054

20540

... More
Supply of Remote Sensor unit for Audio Alram and Acknolwdegmnet

4

8295

33180

... More
Supply, Installation, testing and commissioning of Track Battery charger Monitoring System for 2V/4V/6V/8V batteris with accessories at nominated stations. General Scheme to be approved by Engineer unchage.

4

3951

15804

... More
SMPS based Integrated Power Supply System for Electronic Interlocking a s per RDSO/SPN/165/2012 version -3 or latest and Drg No. CSTE/6155/ 8 of 8. This includes transportation, installation and Commissioning of Integrated Power Supply System.

4

1109950

4439800

... More
SMPS based Integrated Power Supply System for IBS & LC Gate in RE-Section as per RDSO Spec. No RDSO/SPN/165/2012 version -3 or latest and Drg. No. CSTE/6155/ 2 of 7.This includes transportation, installation and Commissioning of Integrated Power Supply System.

4

902951

3611804

... More
Electric Point Machine ,Non Trailable, Internal Locking, 220Mm Throw With IP 67 Motor, 1 Minimum AC Immunity 400Vac With Tools And Complete Accessories Including Complete Ground Connection And Al l Insulation, Crank Handle And Along With Clamp Point Lock 60Kg, TWS As Per Drg.No. RDSO/S/11000 As Per Rdso Spn. Irs:S- 24/2002 With Amd.01 Or Latest. IRS Type.

36

132689

4776804

... More
Main LED Signal lighting unit working on 110v ac as per RDSO specn. No. RDSO/SPN /199/2010rev.1.1 retrofit table in existing CLS housing (sa23002, s23024/m) Red Aspect.

30

7345

220350

... More
Main LED Signal lighting unit working on 110v ac as per RDSO Specn. No. RDSO/SPN/199/2010 rev.1.1 retrofit table in existing CLS housing (sa23002, s23024/m) GREEN Aspect.

28

7454

208712

... More
Main LED signal lighting unit working on 110v ac as per RDSO Specn. No. RDSO/SPN/199/2010rev.1.1 retrofit table in existing CLS housing (sa23002, s23024/m) Yellow Aspect.

58

8040

466320

... More
Main LED Signal lighting unit110v ac for calling on signal in Railway signaling as per RDSO/SPN/153/2011 (rev. 4.1)or latest

2

5663

11326

... More
ROUTE aspect LED signal lighting Unit, 110V Ac, retrofitable in existing CLS housing and compatible with AC LED ECR as per Specification No. RDSO/SPN/153/2011, Revision 4.1. Make /Brand: PTC

60

4719

283140

... More
Main LED Signal lighting unit110v ac for Shunt Signal in railway signaling as per 6 RDSO/SPN/153/2011 (Rev. 4.1) or latest.

8

5418

43344

... More
Installation, wiring, programming, testing and commissioning of EI equipment supplied as per supply item in schedule 'A' including transportation from Consignee's depot to site. The works and materials for installation, wiring, testing and commissioning, grouting, cutting of floors, walls, refilling of the same, re-plastering, required CC/ masonry works, fixing/ placing/ laying of insulated ladders/ casing-capping/ cable trays/ RCC/GI pipes / Cables, termination of cables with lugs/ connectors, painting, / lettering are to be provided/ done by the contractor for the equipments supplied vide Item of Schedule "A" of this contract. This also covers the networking of built in EI Data loggers of all the stations to monitor the system to any other places where desired by Engineer-in- charge. Note: Installation shall be comply with RDSO Technical Advisory Note No STE/E/TAN/3012 dtd. 28.08.2014 or latest. Installation, wiring, programming, testing and commissioning of Operator VDU in Hot stand-by with Redundancy. Any Equipments/cards/Modules required for Hot stand-by with Redundancy shall be supplied & Installed by the Contractor. This also include supply of one no Godrej 1 make operator chair model PCH7001 or better , one no. of composite computer & printer table (Godrej work station table or better) for keeping MT , one no Godrej make operator chair model PCH7001 or better. Termination of indoor/ PIJF cables in relay room on relays, tag blocks, CT racks as per approved wiring diagram including alterations/ modifications as required at site. Soldering to be done at all required termination. Dressing/ lacing of wiring shall be done neatly with help of dressing thread / plastic self-lock strip of suitable size. The tools/ equipments/ materials/ simulation boards required for testing shall be supplied / fabricated by contactor. This included replacement of modules/ cards/ LEDs/ equipments going defective during testing. Necessary power supply boards with required capacity plugs, sockets, surge & lightning protection boxes shall be supplied and installed by the contractor. 230V supply shall be arranged by Railways. In case supplies are required to be extended, from Power room / relay room then same shall be extended by the contractor with his own materials such as 1X16 sq. mm wires, cables, lugs, RCC/GI pipes, insulated ladders etc. After ST/LT testing, Factory Acceptance Tests (FAT) & Square Sheet testing system should be fault free while submitting to Railways, otherwise suitable necessary action can be taken by Engineer-in-charge. (i) With Object Controller

1

1252392

1252392

... More
Earthing of EI equipment, relay racks and Power equipment etc. to be done along with the supply of all requisite materials. Earthing shall be in the form of Ring Earth conforming to RDSO specification No. RDSO/SPN/197/2008 (with a min. of 6 maintenance free earth electrodes) & RDSO Drawing issued under Railway Board letter No. 2010/Sig./SGF/EI (Ansaldo) Dated 22.06.11, made using copper rings with earth resistance less than 1 ohm. The earthing shall be maintenance free & earth 2 enhancement compound should be used. The ring earth shall be connected to copper flat of size 25x3 mm in the relay room and IPS room. This copper flat shall be fixed on the wall to the entire breadth of the Relay room and IPS room as an earth bus bar and all earth connections shall be taken from it. A, B, C, & D class protection shall be provided for all EI equipment. Note: - This will also cover the earthing& necessary protection of EI equipment as per details given in the scope of work of Special Condition of Contract and other requirement given in Chapter of tender document & Pre- commissioning check list of EI system

2

130891

261782

... More
Training of Technician/ Jr. Engineer for installation, Commissioning, Testing, Repairs & Troubleshooting alteration, design of EI system, as per details given in Special Condition of Contract. (Hard copies of training manuals/ course module to be given to each participant).

-

-

3

... More
Training of Officers for installation, Commissioning, Testing, and Repairs &Trouble shooting of the EI system. (Hard copies of training material/ course modules to be given to each participant).

1

29070

29070

... More
"Installation, wiring, testing, and commissioning of Data logger complete along with accessories using Contractors' own wiring & fixing materials as per the following configuration. (It includes loading of NETWORKING software, networking of data logger, installation of FEP & Fault 5 diagnosis system). The requisite communication cable/channel for networking will be arranged by Railway. 1024 digital & 32 analog inputs/ 4096 digital & 32 analog inputs. (All the Indoor & outdoor gears wiring in cataloged included in this along with laying 230V supply cable from IPS room,12 core cable from auto change over for monitoring supplied.) Note :- It included logging of all gears as per site incharge."

4

18811

75244

... More
"Supply, Installation and Commissioning of EI VDU (Visual Display Unit, 4K with all suitable accessories Compatible to El Interlocking in Safe Mode 24x7 at controlling station). The item must comply minimum following specification:- a) Screen Size (Diagonal):- As below b) Resolution :- 4K 6 c) Viewing angle degree: - 178x178 degree d) Brightness :- 500 Nits e) contrast ratio 4000:1 f) Backlit :- Direct LED g) Jack Interface: - HDMI -3 no. 1.2 DP, DVI USB 2.0 -2 no. CI Slot RF In AV In Component In (RCA5 Type) Digital Audio Out RGB In (D-sub 15pin)-PC PC Audio Input RS232C (D-Sub 9pin) RJ45 Stereo mini jack. h) Optical Out :- Available Note: - Screen size will be decided as per instruction of engineer incharge."

-

-

335137

... More
"Supply and Installation of Modular power supply arrangement for VDU and industrial PC (Embedded PC) with input and output redundancy arrangement and Hot pluggable Modules as per RDSO specification. Make Gallant or similar. One set consists of 1. Input O- ring diode module with 7 potential free -1 No contacts (PFC) for two 110 V DC sources from IPS and single 110 VDC bus Qty 1 No. 2. Isolated Inverters (Master / slave) - Input-110 V DC Output: 120 V AC/220V A500VA - 02 Nos. 3. Isolated DC-DC convertors- Input : 110 v DC Output : 24 V DC/ 10A,Qty -10No.s 4. 3 U SS rack with back panel mother board /front panel power connectors inverter auto change over switch and all required over switch and all required protection circuits (3U height for main rack 132.5mm +/-10% & 1U height for mounting 44.5mm +/- 10%) Qty - 1 No. Make Gallant or similar."

2

272862

545724

... More
Supply & installation of Industrial Grade Embedded PC as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 or latest.

2

179360

358720

... More
Design of ST/LT/TOC/Square sheet/RCC (Three copy) for approval. (i) More than four- line station.

1

36186

36186

... More
Design o f Circuit Diagrams consisting Wiring/ Logic diagram, contact analysis, fuse detail, Input/output bit chart, VDU diagram, Interface etc. submission o f Three paper copies for approval. (i) 50 to 100 Routes

1

208545

208545

... More
Design of Miscellaneous diagram consist of Floor Plan of Relay Room , Battery Room, 11 Power Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram , Auto change over diagram, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings (Three copy) for approval. (i) More than four-line station

1

7697

7697

... More
Supply of completions ST/LT/TOC in original tracing along with AutoCAD copies in Pen Drive and six set copies after approval. (i)More than four line station

1

1044

1044

... More
Supply o f Circuit Diagrams consisting wiring/Logic diagram, contact analysis, fuse detail, Input/output bit chart, VDU diagram, Interface in AutoCAD in Pen Drive and Six set of Copies after approval. (i) More than four line station

1

35003

35003

... More
Supply of diagrams consist of Floor Plan of Relay Room, Battery Room, Power 14 Equipment Room, Data logger room, Power Supply Diagrams along with power supply calculation, Earthing Diagram, Power panel diagram, IPS wiring diagram, Auto change over diagram, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawing in original tracing along with AutoCAD in Pen Drive and six set copies after approval. (i) More than four-line station.

1

3721

3721

... More
Factory Acceptance Test / site acceptance test(FAT/SAT).

-

-

15

... More
Re-Design of EI Systems after FAT/SAT with related to application logic & Interface Circuit. Note:-After FAT/SAT either Minimum 2 functional gear (Addition/Deletion of point/signal/Track) or modification in TOC minimum 5 routes in accordance of 3.47, 5.16 and other issues.

1

570471

570471

... More
Commissioning of T-Networking suitable for Networking to the existing Data Logger equipments. This includes supply of all equipment / accessories required for the purpose.

4

7521

30084

... More
Design and supply SWR Diagram on standard tracing paper of 95 grams for each station. Corrected version of SWR plans after checked & approved by Rly's 25 Ferro copies will be supply for each of the plans.

-

-

53506

... More
Preparation of SWR including supply of SWR booklets (25 Nos. per station). (i) For stations having more than 4 lines

1

82691

82691

... More
Supply,Installation,testing & Commissioning of Current referencing device, Half effect based isolated series DC current measuremnt with hardware RS-485 with 5V Power supply and 1ft USB-B type cable at distrubuted EI .

4

37212

148848

... More
Supply,installation,testing & commissioning of Remote data Acquisition device with 3 digit 7-segment LCD display with 5V power supply and 1ft USB-B type cable at distributed EI .

4

35067

140268

... More
Modification/Alteration i n existing E I (Electronic Interlocking) a s p e r latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The 22 complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards / relays / wiring material / connectors / fuses / communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/ LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying o u t o f FAT , S A T ( a s applicable) jointly with Railways a n d satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTO CAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied.

-

-

5159439

... More
Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 1 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards.

1

69363

69363

... More
Installation of Relay Rack Assembly including IDF pillars if any complete with wall 2 supports, scaffolding, ladders, runway for cables, fixing of Relay / Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on WR & the instructions of Rly engineer at site.

14

10011

140154

... More
Installation of Cable Termination Racks Assembly complete including wall supports, 3 scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly engineer at site.

10

9184

91840

... More
Installation wiring testing and commissioning of Fuse changeover system (FACS). Thisincludes the provision of a common Buzzer & indication at the ASM Room & ESM Duty Room and the painting of fuse details. This also includes the fabrication of a frame for the installation of FACS at the Station/ LC gate where the installation of relay racks is not feasible.

22

19822

19822

... More
Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes 5 etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m

190

276

52440

... More
Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide 6 and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.

4500

292

1314000

... More
"Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the 7 ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring)."

800

1217

973600

... More
Cutting of Hard rock in trenches /Preparation of cable way/Chase 150mm wide at the bottom and 300 mm deep in hard rock (Drg prepared by contactor & approved by Engineer In charge) 8 for laying of S&T cables where minimum required depth not possible & which is verified and agreed by Engineer In charge of the work or his representative shall be made as per Drg. No RE/S&T/ALD/SK/301/85. Refilling of the same with concrete mixture of 1:3:6 from top of the cable way/ chase. Payment of concrete will be made separately through a separate item in the schedule of work

200

463

92600

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trucking. This also includes laying of cables in track crossings & road crossings. Item 9 includes provision of labels of colored plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each G.P.(Cables will be daggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes

223

9407

2097761

... More
Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.)

1080

30

32400

... More
Laying and fixing of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm Dia hole, or at any other locations as decided by Site Engineer. The GI pipe is to be 11 filled with chattered compound. It includes supply of all material required for fi Xing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The e laying and fi Xing to be done as per RDSO drawings No. SDO/cable laying/011 and SDO/cable laying/012, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest.

200

195

39000

... More
Digging of cable pit (min2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter.

1

11495

11495

... More
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mm and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.

180

426

76680

... More
Termination of outdoor cables, main cables laid in location boxes, Cable termination 14 rack etc at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.

10000

6

60000

... More
Excavation and Casting of foundation for main signal post as per CSTE/3122 (WR) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.

-

-

15

... More
Excavation and Casting of foundation for Shunt Signal as per Drg. No. CSTE/6090 with 16 Contractor's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc. for Casting of foundation will have to be brought by the Contractor at his own cost.

2

6412

12824

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost.

-

-

447884

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway.

-

-

60168

... More
"Fabrication and fixing of SMC sheet in location box by providing all fixtures as per 19 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Note: SMC sheet will be taken in place of phenolic laminated sheet."

-

-

101764

... More
Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

10

4251

42510

... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 21 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.

5

2139

10695

... More
Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done 22 as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post.

8

3108

24864

... More
Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates / boards if any with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt 23 signal if any. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted on offset bracket with junction type route indicator 1/2/3 or multilamp lamp route indicators mounted on signal post.

26

2140

55640

... More
"Fixing of Calling-on Signal/A-Sign/AG-Sign unit on signal post. The item includes fixing 24 of Co- On signal /'A' sign/ 'AG' sign unit on signal post with bracket, hood etc. Item includes supply bracket & fixing materials etc. by the contactor. The item also includes termination of cables & wiring inside Co- On signal /'A' sign/'AG' sign unit as per standard practice. Note: This Item must be operated individually, Not to be operated in Installation/Erection of CLS."

8

2145

17160

... More
Erection of Position Light Shunt signal with Base, Post, and Signal unit. Wiring & Fixing of Number Plate .The work shall be done as per instructions of Rly engineer at site. 26

12

1877

22524

... More
Erection of Position Light shunt signal on Offset bracket on main signal.

4

1882

7528

... More
Installation of DC track circuits covering points zones also. The item includes provision of continuity bonds of seven strand PVC jacketed wire/ GI wire 8 SWG on rail joints after drilling bond- hole of 7.0/7.1/7.2mm Dia (double bond with sleeves and rail clips are to be provided at each rail joint), insertion of insulated block joint, fixing of Track lead Junction box on MS angle two numbers of 27 size 40X40X5 mm 1200 mm length for track feed/ jumper / track relay ends of track CCTs (as per double TLJB arrangements) and also for fixing jumper cables as per insulation diagram WR Drg No. CSTE/6055 and standard practice, making rail connections through suitable insulated sleeves from Track lead Junction box at TF, jumper & TR end with seven strand PVC jacketed wire /GI wire 8 SWG, rail clips for fixing bond wire on the TLJB as per standard practice, termination of tail cables on bootleg terminals etc. TF/TR wiring shall be fixed on the suitable arrangement on PRC sleepers with the help of hooks. Hooks shall be provided on PRC sleepers with the help of suitable steel bracket. This item also includes fixing & supply of channel pins etc. The item also includes supply of MS angles/ trestles, GI wire 8 SWG / seven strand PVC jacketed wire, hooks, rail clips etc.

75

7684

576300

... More
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports 29 (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection including angles of size 40 x 40 x 5 mm 1200 mm length This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No. S&T/Const./JHS/T 115 &instructions of Rly engineer at site.

10

1351

13510

... More
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.

3500

13

45500

... More
Installation of Maintenance Free Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008.

50

5868

293400

... More
"Installation of Earth Electrode including MS flat for clamp etc. and connection to signalling equipments, lever frames, apparatus cases, signal, relay rack, block instrument, etc. as per technical specification given. This item includes digging of pit in earth 3 M deep & fixing earth 32 electrode p i p e , c a s t i n g o f c e m e n t concrete enclosure & cover a s p e r RDSO/SPN/ 197/2016.Soiltreatment to be done as per std. practice. This item includes provision of MS Flat, Earth lead wires and Soldering of lead wires. The other end o f the wire i s t o b e connected t o block equipment, power equipment, cable sheath, and signals etc. as per site requirements. 7strand GI wire shall be used as earth lead wire. Supply of earth electrode is covered in other Item')."

100

1475

147500

... More
Fabrication and fixing of 'A' Marker (Drg No. CSTE/6180), 'AG' Marker (Drg No. 33 CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). Marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor.

34

1214

41276

... More
Supply & Fixing of Stop Board, Block section limit Board, goods warning board and all other boards with contractors own material. The work shall be done as per instruction of Rly. Engineer incharge as per IRSEM.

10

5245

52450

... More
Fixing & wiring of QNA1 / QNA1K relays for GPR Circuit in apparatus case as per Standard practice. Fixing and wiring material shall be supplied by the contactor.

50

358

17900

... More
Wiring, installing of Magneto / DTMF telephone in ASM office, at locations, Relay Room, Point locations on both directions and siding Point Control locations as per instructions of Engineer ln- Charge for traffic purpose.

6

528

528

... More
Charging of Lead Acid Batteries with contractors' own battery grade sulphuric acid and distilled water with a minimum of two charge-discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per the extant practice of W.Rly & instruction of the Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by the contractor & Rly's site-in-charge. (a) 2V 80AH

-

-

37

... More
Earthwork in filling in embankment, guide bunds, around buried type abutments, bridge gaps, trolley refuges, rain bunds if provided, platforms etc. with earth excavated from outside railway boundary entirely arranged by the contractor at his own cost as per RDSO's latest guidelines 38 and specifications and special condition of contract including all leads, royalty, lifts, ascents, descents, crossing of nallahs or any other obstructions. The rates shall include all dressing of bank to final profile, demarcation and setting out of profile, site clearance, removing of shrubs, roots of vegetation growth, heavy grass, benching of existing slope of old bank, all handling/re-handling. Taxes, Octroi and royalty etc. as a complete job. Cut trees shall be property of railways and to be deposited in the railway godown unless specified otherwise in the Special conditions of contract.

50

146

7300

... More
Hiring of JCB Machine (in good working condition) for leveling and dressing 39 ground/dismantling structures including disposal of debris through dumpers etc. with contractor's labour, JCB machine, machine operator, fuel, etc. The contractor shall arrange road permit for vehicle for all the states of operation, as per instructions of engineer incharge and vehicle shall not be more than three years old.

30

1109

33270

... More
Providing assistance to ESMs/TCM during monitoring Inspection & supervision of signal gears throughout the period as per of instructions of SSE (Sig) In-charge during day/night upto eight hours per day.

360

489

176040

... More
Dismantling of Concrete foundation/ Demolishing RCC/CC/Stone work /Cutting Tar/ 42 carpentering/ CC Flooring / Precast concrete slab/ Brick work including leading the debris inside Railway limit or outside Railway limit as directed by site in charge. This work to be done by contactors with his own vehicle and labour.

50

594

29700

... More
Releasing of Existing Panel, Power Equipments,relays and relay racks,CT racks, 43 Batteries, Block Instruments, Ground frames, Location Boxes, TLJBs, Signal Posts, Signal Units, Equipment inside the location boxes, Lifting Barrier, rodding runs etc as applicable including the breaking of foundation etc. as per the instructions of Rly Engineer at site & their transportation to nominated depot. This work to be done by contactors with his own vehicle and labour.

4

14035

56140

... More
Shifting of existing full location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making 44 of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

4

3218

12872

... More
Shifting of existing half location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making 45 of pit for shifting of location box horizontally opposite to railway This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

4

2357

9428

... More
Preparation and fixing of location box board on 03 mm ACP sheet with size 12 x 18 size A3 for location box including pasting of printed/ painted vinyl sheet and lamination (printing/painting of location detail on vinyl sheet covered in schedule item separately).

140

227

31780

... More
Lettering & Numbering of detail and description writing of on relay rack, relays, cable termination rack, battery &power equipments, IPS, operating panel, axle counter etc. constituting entire system with contractor's own paint and writing material. The work shall be done as per extant practice on W.R Rly & instruction of Rly engineer at site.

1

3554

3554

... More
As and when required by the Engineer in charge arranging /providing of labors for 48 various safety related works such as protection of track etc. with contractor's T&P, equipment, hand signal flags, spanners, hammers, etc. as per specification special conditions and detailed scope of work as furnished in the tender and directed by the engineer incharge.

360

613

220680

... More
"Fixing o f Electrical Point Machine o n the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 91 51-52 or 9710 or 9161 as per section of rails used. Item includes fixing switch extension bracket, providing insulation fo r switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes : (i) Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts 49 including castle nuts, spring washers (ii) All smithy & fitting works required a t site fo r complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on WR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M- 6 / Screw less terminals will be supplied by Railways / covered in Schedule separately."

36

24970

898920

... More
Refixing of electrical point machine, ground connection during phase working (No 50 interlocked working) after removing the existing fitting if any, adjustment if necessary, cable termination, wiring ,testing and commissioning of electrically operated point, fixing and connecting point indicator on derail switch if necessary. The work shall be done as per extant practice on WR & the instruction of Railway Engineer at site

2

2037

4074

... More
Supply & Fixing of Protective screen of expanded metal 12 SWG of Size 1200 X 1500 mm on Signaling as per standard practice for protecting against voltage in AC Traction area as per instruction of Engineer In Charge.

2

4556

9112

... More
UL/EN/FM/VDS/LPCB approved Microprocessor based Networkable Analog addressable and modular type of Fire Alarm Control panel with display, in built changing facility and provision of GSM module suitable to send SMS to configured mobile numbers.

2

67358

134716

... More
"Supply, Installation, Testing & Commissioning of Analogue Addressable Multisensor 53 Detector with multiple sensitivity (adjustable at site) levels e.g. smoke, heat, rate of rise heat etc, programmable for timed automatic sensitivity selection with base, and other accessories as required.as per RDSO specification no. RDSO/SPN/217/2021 ver 3.0 or latest."

50

3073

153650

... More
Analogue Addressable, resettable Manual Call point with inbuilt integral short circuit isolator having status LED for alarming & standby mode, Electronically addressed.

2

3787

7574

... More
Supply, Installation, Testing and Commissioning of Analogue Type Linear Heat Sensing cable (LHS) / Linear Heat Detection (LHD) tube compying to RDSO/SPN/217/2021 (Ver. 3.0 or latest) As it is the latest UL or FM or VDS or LPCB approved / listed. 56

600

680

408000

... More
Liner heat sensing (LHS) interface module.

2

54194

108388

... More
Supply, Installation, Testing and Commissioning of aspirating (Air Sampling) Type smoke detector with four zone interface module and isolator with power supply unit, back box and all other accessories as per the RDSO Specification RDSO/SPN/217/2021 ver 3.0 or latest) 58

2

149203

298406

... More
UV/IR Flame detector with required modules. 59

2

72222

144444

... More
Hooter cum Strobe.

2

5845

11690

... More
Fire survival circuit integrity cable i.e. armored cable & power cable with all accessories for connection of all fire alarm devices 2 core 1.5 Sq.mm.

600

77

46200

... More
Supply, Installation, Testing & Commissioning of relay module with back box and all other accessories as per the RDSO specification No. RDSO/SPN/217/2021 ver 3.0 or latest.

2

3912

7824

... More
Supply and fixing of PVC pipe of 25 mm size of IS standards on wall/floor etc All necessary items like screws/nails required to be supplied by contractor. Inspection by representative.

600

35

21000

... More
Laying / drawing of various type of cables on PVC pipe /capping casing, or cable trays, ladder,shelter etc as instructed by Railway engineer at site. (Indoor cables to be drawn through pipe,outddor cables if required o be clamped onwall/Fl 64

600

5

3000

... More
Addressable loop powdered sounder cum Strobe with inbuilt fault isolator.

2

7641

15282

... More
Auto telephone dialer (GSM) to send the pre-recorded message to multiple mobile Nos. programmed. 66

2

6376

12752

... More
Power supply Unit 24VDC, 5 Amps, with two batteries.

2

27946

55893.6

... More
Hiring of one non-AC pick up vehicle for Supervisors(up to 2000 Kms per month)Tata/Mahindra or similar type of vehicle including maintenance, major minor repairs, cost of lubrication, fuel, drivers and all other ancillary cost etc. complete Per

12

47043

564516

... More
Installation of Central Evaluator of axle Counter, wiring from CT rack to Central Evaluator, installation and wiring of the reset box, LV box (if required) and associated power supply wiring. This includes supply of shielded cable of required conductor size for wiring between CT rack to 69 evaluator rack, all other wires, power supply cable and wiring materials. The power supply cable from power room to Central Evaluator should not be less than 10 sq.mm PVC wire. Earthing as per OEM's guidelines & specification with their own material. This also includes painting and writing work on evaluator as per site requirement. NOTE: Installation /programming / configuration / commissioning of Axle counter equipment to be carried out in accordance with latest guidelines issued by Railways/ RDSO preferably by Authorised representative of OEM.

1

13116

13116

... More
Transportation of S&T material leading up to 1 Km including Loading from Starting point, unloading & Stacking at destination. 71

10

505

5050

... More
Extra for each additional 1 Km or part thereof.

20

5

100

... More
"Design & Supply of circuits and plans to suit layout given in the signalling plan of IBS/ABS/LCGATE. All plans and wiring diagram shall be prepared on Auto cad Drawing and supplied with CD/ USB Pen Drive.This will include supply of: 1. Control cum Indication panel diagram, 2.Route section plan, 3.squaresheet, 4.wiring diagrams 5. Relay rack/ Relay arrangements 6.Bus bar details, 7.Fuse analysis 8.contact analysis 9.Relay room tag block analysis 10. Panel tag block analysis, 11.Power panel diagram 12. IPS wiring diagram 13.Auto change over diagram 14.Power equipment arrangement with program switch 15. Block circuit wiring diagram 1 6 Digital Axle counter wiring 72 diagram and all other relevant drawings NOTE: The contactor shall initially supply 2 sets of documents(Paper Prints) for approval of Railways. Railway will return one set to the contactor duly approved with alterations/corrections, i f any. T h e contactor shall incorporate Railways' alterations/corrections/ comments, if any, in the tracing & CD/USB Pen Drive without any deviation and submit all the tracings and Final CD/ USB Pen Drive complete with all respect for Approval of Railways. After Approval of Railways on the tracings, the contractor shall submit 3 sets of final approved diagrams tithe Railways within 15 days. He shall ensure the each sheaths a block for signature of railway official as well as a block for signature of firm, duly signed by the authorized signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each IBS/ABS/LC gate."

4

12900

51600

... More
"Installation, Wiring and testing of Integrated Power Supply System. This includes power distribution connection to bus bars and relay racks in the room with contractor's own wiring materials and fabrication and fixing of AC/DC power distribution board made on 8mm thick SMC sheets or any standard make with connections suitable for 32 A. Wiring to be done considering site 75 requirement, depending upon the load with suitable wires, lugs & glands a s per instructions of Engineer-in-charge. T h e w o r k includes installation o f ELD's, fix ing & wir ing o f change over switch(program switch) for selection of DG set supply (DG1 & DG2) and wiring of change over switch (program switch) for selection of mains or DG supply. This item also includes supply & fixing of ladder along the wall for carrying power supply wires/cables from IPS room to Relay room/power room etc. Any masonry work required will be carried out by contactors own material."

-

-

538536

... More
Installations, wiring, testing and commissioning of Remote Terminal Unit complete 76 along with accessories using Contractor's o w n wiring &fixing materials. (It includes loading of NETWORKING software and networking with data logger. The requisite communication cable/channel for networking will be arranged by Railway.

4

6720

26880

... More
Installation & commissioning of Sliding booms with E type lock and KLCR. This includes wiring of KLCR, running of cables, necessary, painting & transportation of materials from store to site. All material required to commissioning of slide booms on gate will be supplied by the contactor.

4

15612

62448

... More
Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD in A3/A4 size. The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards.

1

9873

9873

... More
Supply of final Cable Route Plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables in original tracing along with Auto CAD in Pen Drive and Six set copies after approval.

1

1580

1580

... More
Preparation of Cable Route Plan of buried S & T Cables using Radio Detector 8200 GS or 82 Similar model GPS Model,DGSP and Drone for Per Trench per Km. For existing cables a s per the instruction of Engineer in- charge. Submission of Drone Report in Hard Copy 1 set and DGPS output in KMZ File format.

20

53987

1079740

... More
Fixing of Junction type Route Indication 1-Way/2-Way/3-Wayon the top of the signal post.

4

738

2954

... More
Tripod Earthing of HADAC to be done along with the supply of all requisite materials. 84 Earthing shall be in the form of Tripod Earth conforming to RDSO specification No. RDSO/SPN/197/2008 (with 3 no.s maintenance free earth electrodes), with earth resistance less than 1 ohm. The earthing shall b e maintenance free & earth enhancement compound should b e used. The earths shall be interconnected by copper strip of size 25x3 mm.

1

37526

37526.61

... More
Supply and fixing of CH/KLCR boxes appropriate size in field / in location boxes / in SM 85 office / at LC gate as per site condition. It should be made of Hylam /wooden (teak wood) of high quality as per requirement. Item includes supply of any minor bracket nuts, bolts and hole drilling MS angle, MS plate etc. It also includes fixing of KLCR relays in the boxes. Prior approval to be taken from Engg. In charge before supply of box.

15

1536

23047.35

... More
Supplying & fixing of key box made of MS sheet/ wood with a glass front and padlocking 86 and sealing arrangements per std practice. Pad lock to be supplied by the contractor. All material i.e. wood, handle, hinges, glass sheet of 3 mm thick to be supplied by the contractor. Box to be powder coated/polished and description/size to be as per instructions of Engineer in - charge.

2

1392

2785.66

... More
Supply, installation, fixing, wiring, testing and commissioning of Common Audio-Visual Alarm Unit (CAVA)-for Fuse Auto Changeover system as per RDSO specification RDSO/SPN/209/2012 Rev. 2.0 or latest.

2

2565

5131.22

... More
Fixing of KLCR and its with this includes supply of MS sheet box for fixing of KLCR relay along with push button etc. (KLCR in other shedule)

8

5388

43104

... More
"Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Full Case."

30

128

3840

... More
"Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Half Case."

20

86

1720

... More
Design,supply, testing and commissioning of Remote Diagnostic and Predictive 1 Maintenance System (RDPMs) as per Draft RDSO document No. RDSO/RDPM/FRS/2021; as per Signalling Plan Enclosed. (The Detailed break up of various modules/components are enclosed separtly for annexure.The detailed of Design/schematic drawing, make and model of various product being proposed to be provided for RDPMS system.)

1

3319284

3319284

... More
Manual Horizontal Auger boring for crossing of Road at depth of 1.0m/1.02m from 2 ground level including insertion of 100mm dia (with thickness 3.65mmm) GI pipes/couping etc. all complete as per direction of engineer in charge. supply of GI pipes is covered separately in schedule 'A'

500

1007

503500

... More
Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately)

5700

22

125400

... More
Charging of Lead Acid Batteries with contractors own battery grade sulphuric acid and 4 distilled water with minimum two charge - discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of W.Rly & instruction of Engineer-in-charge. Detailed measurements of initial charging shall be recorded jointly by contractor & Rly's site-in-charge. (a) Charging of 2V 200AH

48

1030

49440

... More
Complete painting and varnishing work of all S&T Gears at a station not covered else where in the schedule. This includes painting of signal posts and fittings, apparatus cases, point machines, junction boxes, signal machine, rail post etc. complete. This also includes varnishing, 5 description writing on terminals, apparatus cases, point machine, Signal Nos. and other details as per S.E.M. and instructions of Engineer at site. Item includes painting of distance of main signal run from GP on each GP nearest to cable run and painting of distance of signal base from nearest line on the signal base. At least two coats of paint is to be applied besides primary coating of red oxide. This includes supply of paints, varnishes and all material required for complete painting work at a station. This includes painting of all existing S&T gears also.

-

-

72565

... More
Fabrication and supply of equipment rack of 18' gauge of M.S. sheet for housing of signaling and telecommunication equipments installed in station master office.

-

-

53921

... More
"Supply, Installation, testing and commissioning of LED indication system with 7 indication, buzzer & acknowledgement button up to 6- line station with interface facility to existing data logger and modification of data logger embedded software when a station master fails to set the point against the occupied line, within stipulated time after arrival of the train. "

1

47729

47729

... More
Laying of UTP CAT-6 cable through steel pipes/casing caping etc. as per technical specification

305

8

2440

... More
Shifting of existing Signal along with foundation as per site requirement. This inclusive of required labour, machinery like hydra, JCB etc.

8

7730

61840

... More
Preparing of SIP of each station prepared of yard diagrams in CAD and submit check 10 print. After making correction/modification or alteration return us corrected copy of each diagram in turn and correct all this correction in soft copy & PDF copy of diagram and make diagram completely. All diagram take out color print venyle print with lamination and frame with hanging arrangement. 11

-

-

32472

... More
Supply and fixing of cable truff of 4 inch x 4 inch

100

328

32800

... More
Installation of Axle counter cable conductor's Earth resistance Sensing unit. Microcontraoller based for 12 nos counductors without cable

2

3815

7630

... More
Supply of ferrules of different colour, printing termination details/ functions in different colours as per Railway specification and installation in location box CTR and power board etc. All the materials required for the work shall be supplied by the contractor. (unit read as per ferrule)

16000

11

176000

... More
Supply,Instllation,Testing and Commissining of CPVC Pipe for Aspiration Detecton system as per RDSO/SPN/217/2019 Ver.3 or later shall be as listed / approved by UL or VDs or LPCB with appropriate equivalent standard.

-

-

14

... More
Translation of Station Working Rulesfrom english to hindi and framing outin DIGLOT form (or similar software)as per extant Rly practice. Therequired SWR in english will beprovided by the contractor and hasbeen covered separately in item.

1

5239

5239

... More
"Supply, Installation, Testing and Commissioning of Block proving with digital Axle counter using UFSBI complete set for Double line operation.as per IRS: S-105/2012Ver.0with latest amendment &Manufacturing specification. NOTE: One set will include equipments required for one complete double line Block Section except DAC. Each Set consisting of following: 1-Universal fail safe block interface for double line as per RDSO Spec.no. IRS: S.105/2012 with latest version and amdt. It shall have auto changeover facility for quad and E1 Channel, necessary interface for quad and E1channel to be supplied along with auto changeover arrangement. Quantity of this item -02 no in one set. 2-Block panel complete with all accessories as per RDSO/S/3/2017 with latest amdt QTY-02 no. 3- 1 Relay rack with double locking and sealing arrangement as per RDSO Drg.No. RDSO/S/3/2018 including relays for each Relay rack (QN1-19 no., QNA1-07no, QL1-02 and Timers- 1 no).Quantity of this item -02no intone set . 4-Block telephone with accessories a s p e r RDSOspec.no. RDSO/SPN /191/2000(the block phone should work without any interruption after auto changeover). Quantity- 2no. 5- Supply of reliability improvement kit suitable to work with UFSBI as per RDSO/SPN/147/2005 or latest. It comprises (a) automatic media changeover of modem working on redundant channel for data transmission on OFC/quad/ micro wave radio (any two media)-1pair (b) secondary modem for UFSBI for use with secondary media OFC/quad/voice channel=1pair(c) power & data SPD: type c &d: power line VF 24 AC/DC-2no, V20C/3PH 150v-2no) & dataline SPD (MDP 4D/5T- 2no). (d)Power monitor and soft startunit PMSS - 1 Pair. Make/Brand: Self."

2

1223660

2447320

... More
"Supply, Installation, Testing and Commissioning of High Availability Single section digital axle counters with Dual sensor system as per RDSO/SPN/177/2012 version 3or latest. This includes The supply of High frequency web mounting type Tx coil/Rx coil, VR/PR Box duly wired, Vital 1 relays, PR Relays, Clamp with deflector plates & hardware, Dual display reset box with auto resetting facility, Surge voltage protection devices and filter card to be mounted on din rail etc. as per OEM for complete installation & testing& commissioning of(HASSDAC) system NOTE: One set of HASSDAC system will include equipment required to monitor One Up line or One Den line of a full Block Section between two stations. Note: - "Supply of HASSDAC as per RDSO specification along with outdoor industrial grade enclosure (Approved by Railways) similar to Rattle/Pyrotech make."

2

758153

1516306

... More
Supply of HDPE duct 40/33 mm as per RDSO/SPN/TC/45/2013 Rev 2.0 and Amd.2 or latest with latest amendments. For each Km of HDPE duct following items are to be supplied: - (a) End Plugs- 2 Nos. (b) Cable sealing plugs -2 Nos. (c) Plastic couplers slip fit/push fit type - 2 Nos. (d) End 1 plugs to be provided along with drum -2 Nos. The color and nomenclature for short haul up side- Duct color-Green, Code printed -WRSU(at every meter), for Medium Haul- Dn Side-Duct color-Blue, code printed- WRMD(at every meter), for Long Haul - Up Side- Duct color-Orange, code printed-WRLU(at every meter), Long Haul - Dn Side- Duct color-Grey, Code printed-WRLD(at every meter),Local Tail OFC Cable-Duct color-Yellow, Code printed-WRT(at every meter).

45

51130

2300850

... More
Supply of Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/ SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia, & 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified.

50

1779

88950

... More
Supply of 2 x 48 Fiber 2x 48 SC Type Rack Mountable FDMS loaded with SC '0' DB & Adaptor SC SM pigtail 1.5 meters with all the accessories required for installation.

36

43997

1583892

... More
Supply of Straight Joint Enclosures (SJC) complete with all accessories as per GR/ OJC 4 /02/02 Sept 2003 for 48 fiber, Raychem make model FOSC 400 B4 48F or RSICS make model 1500-L 183-XX or Birla VXL make model VT-200 or 3 M make model 2179 CS or TYCO make or better as per instruction and approval of Engineer In charge.

20

4088

81760

... More
Supply of Thermo shrinkable joint kit as per RDSO spec no. IRS TC 77/2012 Rev-3 or latest suitable for 2T joint RTSF3 suitable to 6-quad cable of spec no. IRS TC-30/2005, Ver-1, Amd-4 or latest.

20

3058

61160

... More
Supply of one Quad VF 2T Transformer joint assemble of VF transformer 1120:470. As per IRS:TC 76/2021 ver 1.0 or latest.

20

1297

25940

... More
Supply of G.I. Pipes 100 mm dia medium grade engraved on pipe as per spec. no. IS 1239 of 1990 or 1992 or latest with sockets and fittings. (Surya, Jindal, Tata, or Asian make.)

500

635

317500

... More
Supply of Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO/RDSO/E&B /001 and RDSO Spec No. RDSO/SPN/197/2008 or latest.

3

12352

37056

... More
Supply of Emergency Socket Box in FRP material as per RDSO Spec RDSO/SPN/TC/44/2002 Amd 3.0 or latest.

15

1808

27120

... More
Supply of 6-pin emergency plug & socket flat type as per RDSO spec no. IRS: TC-42-87 Amd. 3 or latest.

15

557

8355

... More
Supply of 20 Pair CT Box Wago Type made up of atleast 18 SWG galvanised MS sheet, 11 spray painted Gray Colour, locking arrangenment, Termination of 0.9mm U/G Quad cable, it includes supply of Hylum Sheet 12mm 52 thick, Nuts, Bolts, suitable size of GI Pipe for Fixing on the wall for U/G Quad Cable, with disconnection facility.

6

2596

15576

... More
Supply of Optical Time Domain Reflectometer (Type-I) (1310 nm & 1550 nm wavelength) for Long Haul Applications with FDD adoptor FC-PC and SC-PC as per TEC/GR/ TX/ OTD- 01/04/APR-2010 or latest. With report generation tool and software

1

314468

314468

... More
Supply of Single Fiber Fusion Splicer Similar to Fujikura 80C with Standard Accessories : AC ADAPTER /BATTERY Charger ADC-18 1PC, AC Power Cord ACC-XX: 1PC spare electrode Elect2-20:1 13 pair carrying case CC-30:1PC USB cable USB-01: 1PC Sleeve loader SL01:1 PC dispenser AP- 01: 1 PC screwdriver SC-01 1PC, Instruction manual: 1 PC Quick reference Guide 1PC warning& cautions: 1 PC ; BATTERY RACK BRT-09, Battery charger cord DCC-18: 1 PC High precision Fiber cleaner CT-06: 1 PC, 3 in- 1 Stripper : 1PC & Protection sleeves: 25 nos. (A demo shall be arranged along with supply.)

1

437578

437578

... More
Supply of Tool & Testing for OFC Cable (OFC power meter 1310/1550 nm & OFC power source/generator 650/1310/ 1550 nm) with tool box as per technical specification.

1

11667

11667

... More
Supply of 4/2 wire Emergency portable control telephone IRS TC: 03 TC-75/99 with amendment 1&2 or latest along with standard lengthh line cord and 6 pin plug as per RDSO Spec no. IRS TC 42/87 or latest

1

2649

2649

... More
Supply of 19" covered racks, Vero President /Rittel make or similar having size of approximately 2.2 mtr. (42U) height x 600mm width x 600mm depth and duly approved by the engineer in charge of the work. The rack shall be complete with all fittings for housing SDH equipment, primary Muxes, DDF, MDF using krone module and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack.

5

37712

188560

... More
Supply of Standard 19" Rackmountable, (-) 48V DC Working, AddDrop STM-4 SDH Equipment conforming to TEC GR No.GR/SDH/-010/03 JA 2011 (with the latest amendment) complete with redundant power supply, 2 Nos. STM 4 of Aggregate L 4.2 Optical interface Modules/ Cards, one each for East and West side TX/RX and 2 nos. of STM-1 S1.1 or L1.1 Optical interface modules complete with 5 mts. long Optical Patch Cords, 63 E1s cards with DDFs and Cable assembly for 17 termination to DDF, and minimum 8 nos. of 10/100 Base-T Ethernet Ports/Fast Ethernet on SDH (EoS) 10/100 Base-T interface Module/ Card supporting with LCAS and GFP, Order wire sub-rack, DDF installation Material, Manuals, and other accessories along with Complete Engineering Order Wire (EOW) arrangement. Note: (i) It should have the necessary software/Firmware for Local/remote Monitoring/ Configuration of the equipment through NMS. (ii) Two no MCBs of appropriate rating along with necessary connecting cords and cables for the Power Supply Module/Card should be supplied and installed as per instruction on the site in charge.

1

315274

315274

... More
Supply of 2 MB programmable primary digital drop insert multiplex as per RDSO Specs. IRS-TC 68/2012 Amdt. 1 or latest with conference facility and other stipulations of tender documents fully wired for 30 channels complete with power supply card remote control supervision facility and all other accessories, installation materials, manuals etc. it should have facilities to accommodate data 18 interface card in multiple drop mode and should be able to support card needed for video conferencing and ISDN. It shall also support NMS operations from local/remote locations to be provided in the section and should be compatible as well as inter operable at card level of the equipment provided in the adjoining section. The above MUX should be equipped with following circuits with maximum E & M cards got approved before supply. i) 2 wire/4 wire E & M VF Circuits (Minimum 4 circuits/card) ii Subscribers loop circuits (Minimum 4 circuits/card) iii) Exchange loop circuits (Minimum 4 nos.).

1

164393

164393

... More
Supply of way station equipment with necessary mounting arrangement on composite 19 rack or on wall. It shall be (-) 48 Volt operated and shall have a provision to connect at least four station telephones and have a facility to give more connection. As per RDSO Spec. no. RDSO/SPN/TC/66/2007 or latest amd. 1 & 2.

1

63394

63394

... More
Supply of Fixed cellular telephone- GSM 2G/3G/4G LTE, Vo LTE support, WiFi function 20 with minimum battery capacity 1000mAh, suitable adaptor and surge protection. The FCT should be suitable for 4G VoLTE SIMs of JIO and 3G/4G of BSNL and other service providers. Make Beetel FWP F3-4G or Similar from Beetel or Motorola or Matrix only. Warranty minimum 1 year.

1

5114

5114

... More
Supply of Trans receiver VHF digital radio set 25 Watt as per RDSO specification No RDSO/SPN/TC /107/2018 rev. 0.0 amendment 1.0 or late synthesized configuration VM4 Band 146- 174 MHz channel spacing 125 with power supply unit SMPS 12 volt power equipment : trance Reciver 21 VHF , mobile / static , output current 15 Amps. Charging float and boost accessories and add- ons for base/mobile. Trans receiver description (1) 30 Mtrs., RG, 213 Co- Axial cable with both end connector. (2) 6 dB Gain GP Antenna VHF. scanning features to be programmed as per requirement of Division. Along with DTMF MIC, mic hanger, DC cable, mounting bracket user manual, power supply unit ( 12Volt /15 Amp) cum charger ( float cum boost) diamond 6.5 db gain VHF GP antenna model CP -22E. Accepted make: Motorola XIRM-6660i or similar.

1

34184

34184

... More
Supply of CLI push button telephones suitable for connection with way side equipment and the system mentioned above. as per DOT/TEC specifications TEC /GR/CP/Tele/-002/05 Jan-2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms.

3

650

1950

... More
Supply of maintenance free VRLA secondary cells duly charged of 48V 200AH and each 23 2.0V when fully charged 200AH capacity along with accessories i.e. inter sell connectivity links/float, 4 Nos. Insulators for each cell 24 Nos. of cell per set as per RDSO Spcn. IRS/S /93/96A with latest amendments with cuticle steel/hylam tray battery rack to install /house batteries.

1

61198

61198

... More
Supply of 48 V, 50 amps battery charger for telecom use as per No. RDSO/SPN./TL/23 24 /1999 (ver. 4) or latest in N+1 configuration i.e. using (2+1) modules of 25 amps with automatic switching between the modules for two sets of 200 AH battery for charging with SMF VRLA. It shall be equipped with surge and lightening protection of class 'B' and' C' the configuration shall be decided as per site requirement.

1

67647

67647

... More
Supply of UTP CAT 6 Cable for Indoor networking use, make: Molex or D-Link or Systemax.

610

24

14640

... More
Supply of STP CAT-6 cable compliant with latest EIA/TIA-568-B. 2-1 standard of make D- Link/ DAX/Lucent/Crone/Amp or similar

1220

25

30500

... More
Supply of Patch Cord cable (10 m long with SC-APC/FC-PC/LC-FC/SCSC/LC-SC/LC-LC/ST- SC as per site requirement) as per RDSO/SPN /TC/69 /2007 rev 0 or at the latest.

30

606

18180

... More
Supply of Pigtail cable (10 m long with FC-PC connector and ST-SC connector Patch cord). As per engineer incharge.

30

472

14160

... More
Supply of Microphone with chord and other accessories with Microphone stand confirming to RDSO/SPN/TC/63/2006 Rev 0.0 or latest.

1

2836

2836

... More
Supply of Waterproof PA Horn speaker 30 watts as per clause No 4.5 of RDSO Spec No. RDSO/SPN/TC/63/2006 Rev 0.0 or latest.

20

1312

26240

... More
Supply of 15 Watts Column speaker with 100V Line Matching transformer as per clause No 4.6 of RDSO specification No. RDSO/SPN/TC/63/2006 Rev 0.0 or latest.

6

1213

7278

... More
Supply of Twin Core shielded cable of size 24/36 SWG with a standard color (Red and Black) having screening coverage of 95 % area of the sheath of the cable using a braided copper conductor.

1500

39

58500

... More
Supply of 19''- 24U Dustproof Cabinet along with Front Glass Door, Key locking at Front 33 and Rear Door, Horizontal/Vertical Shelf arrangement, Termination Panel & Fan Cooling arrangements as per instruction of Site Engineer for Housing of Various S&T equipment like PA System, Router, Switches, Modem, E1/LAN Extender, etc

1

36488

36488

... More
Supply of Universal Fare Display System with Power, Data Cable &Connectors for PRS/UTS/Thin Client as per given Technical Specifications.

1

4768

4768

... More
Supply of Central Data Controller Unit conforming to system requirement as per RDSO Specification No.RDSO/ SPN/ TC/ 108/2019 Rev.0.0 with Amdt -1 or latest. The control console shall have main and standby CPU to work in standby mode, one Nos. of 1 KVA UPS with two independent batteries, two LCD monitor [19 inch], CCU Rack, KVM Switch, CDS [Layer 3 12 Port Switch of make CISCO, HP, Juniper,Brocade, Avaya, Extreme, Netgear,D-link] and other accessories, housed in a 35 standard size cabinet along with driving Software for integrated passenger information system as per RDSO Specification No.RDSO/ SPN/ TC/ 108 /2019 Ver 1.0 with Amdt -1 or latest. this includes supply and installation of SW for Announcement system with necessary interface and announcement recording [Hindi/English/ Region language fresh studio copy of voice files.] as per RDSO Specification No. RDSO/ SPN/ TC/108/ 2019 Rev.0.0 with Amdt -1 or latest. [the same to be interfaced with existing audio and video system installed at the station. The software should support all types of display /announcement by merely adding necessary hardware in future [single/ multiline arrival/ departure train information display boards, single sided/double sided,CGDB, AGDB,LCD/LED/Plasma TVs etc.]

1

457063

457063

... More
Supply of Platform Data Controller as per RDSO specification no. RDSO/SPN/ TC/ 108/ 2019, Ver. 1.0, Amdt.- 1 or latest and as per instruction of Engineer incharge.

3

49487

148461

... More
Supply of Double Face Coach Guidance Display Board with all necessary accessories confirming to system requirement as per RDSO Specification No. RDSO/ SPN/ TC/ 108/2019 Ver.1.0 with Amdt -1 or latest

72

28614

2060208

... More
Supply of 5-line single-face indoor display boards with their mechanical structure and necessary software i.e conforming to system requirements along with all accessories as per RDSO Specification No. RDSO/SPN /TC/ 108/ 2019 Ver.1.0 or the latest.

1

456364

456364

... More
Supply of Single Line Double face Platform Display Boards with all accessories as per RDSO specification no RDSO Specification No. RDSO/SPN /TC/108/2019 Ver.1.0 or the latest.

6

222322

1333932

... More
Supply of power cable 3 core, 2.5 sq mm,multi strand [36/0.3mm dia.] cable as per IS 694:1990 reaffirmed 1995 or latest suitable for Railway electrification area, shall be of reputed make like Havells, Delton, LAPP, Finolex, or superior.

-

-

40

... More
Supply of 6 CORE FIBER Optic Fibre cable as per RDSO spec. No. IRS:TC:55/2006 (Rev- 1) with Amend. No. 2 or latest.

3000

28

84000

... More
Supply of Train information At A Glance display board with all accessories as per RDSO specification no. RDSO/ SPN/ TC/ 108/2019 Ver.1.0 with Amdt -1 or latest.

1

226096

226096

... More
Cable route survey & Preparation of as built proposed and later final cable route and other plans (for OFC as well as other telecom cables whose laying is covered in this schedule) taking into account the points mentioned in chapter II & other chapters of technical require ment on Auto CAD for entire sections. The cable route & other plans shall be prepared by contractor after joint 1 survey, got approved from engineer in charge, changes during course of execution shall be incorporated in the same. After completion of the work all comple tion documents of tracing papers along with six prints of cable route plan, jointing & splicing schedule, cable hut wiring diagram etc. in six sets for each station and section in folders shall be supplied by the contractor. Contractor shall also supply the Auto CAD documents on CD. All the required materials, accessories including tracings, papers etc, shall be contractor's own.

20

1451

29020

... More
Installation of fiber distribution management system rack mountable LIU (Supply 2 covered Above) with all installation materials, restoration wall etc. to original condition , splicing and termination of 2 x 48 fiber cable (With all contractor's materials), routing /dressing fibers as per directions of Engineer in-charge.

36

3914

140904

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 3 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the end of duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

45

6391

287595

... More
Blowing of OFC through HDPE duct & protective work (elicited in above item) already 4 provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn /laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost.

45

12032

541440

... More
Transportation and laying of 6 Quad/PIJF cables in Trenches/ GI pipe /RCC pipe/DWC 5 pipe, Trunking etc as per approved cable route Plan and instruction of Site Engineer. Empty cable drums to be retained by the contractor the cable drums with unused cable at site to be returned by the contractor from site to Stores of SSE/T/C/SBI.

15

5804

87060

... More
Excavation of trench 300mm wide at the bottom and 1.2 mtr deep, in all type of soils including clearing of trees, bushes, etc. and refilling of cable trench by excavated soil and ramming after laying of HDPE DUCT (laying of HDPE/DWC & 6 Quad. cables , PDF cables etc., will be paid under 6 different items of the schedule). Where desired dimensions of trenches could not be achieved proportionate payment will be made as decided by Engineer-in-charge of the Railway at site.The trenching outside the station limits I.e.) between the home signal of station 'A' to home signal of station 'B' may be done manually or by machine, as per the directions of site in charge. In no case the payment will be made for the trench of higher dimensions, than the dimensions as mentioned above.

360

280

100800

... More
Excavation of cable trench in rocky area, 450 mm wide at the top, 300 mm at thebottom and minimum 0.5 meter deep in rocky area (hard rocky soil mixed with boulders/hard murrum) including cleaning of trees, bushes. The trenching will be done manually only and limited to the stretch between the home signal to home signal of each station and other locations as per the directives of the site in charge. Where desired dimensions of trenches could not be not achieved proportionate payment will be made as decided by Engineer-in-charge of the Railway at site. In no case the payment will be made for trench of higher dimensions than the dimensions as mentioned above. 1. If, in case, depth of 1.2 M could not be achieved and Engineer-in-charge approves the same and then only after his instructions, the following protection work will be done - a) Depth of trench more than 1 Mtr. does not require any protection work and the payment will be made on pro-rate bases (Volumetric) under this item, after laying of HDPE /DWC Pipes, 6 quad. cable, PDF cables in the trenches (Laying of HPDE/DWC, 6 Quad cable & PDF cable, will be paid under different items of the schedule) and refilling of cable trench by excavated soft, soil, murmur, boulders etc. and ramming over the refilled trench. Care should be taken while refilling the cable trench such that the murrum/boulders etc do not damage the cable.

500

436

218000

... More
Splicing of laid under above items OFC cable and making the splice joint in dust free environment with contractor's own equipments and labour. Straight joint enclosure (SJC) is covered under schedule 'C1' remaining all required materials, tools , plants shall be arranged by the 8 contractor. splicing shall be started from one end and each splicing shall be monitored after splicing and after closing the enclosure for all the fibers from one central location by contractor's engineer with his own OTDR and optic Talk set with railway engineer , trace for the fibers shall be taken and signed jointly, if any fibred splice shows high loss/lossy event, the same shall be redone before completion of splicing work. The splice loss shall be as per the policy/technical circulars issued by the railways from time to time.

20

7482

149640

... More
Supply & Installation of Plastocrate pre-fabricated (RCC) OFC jointing pits size 1000 mm x 1000 mm x 800 mm (depth) . The material shall be supplied as per engineer in charge instructions.

20

5299

105980

... More
Construction of brick chamber behind of OFC room 2x2x1m. Item includes arranging of all material required for the same such as bricks, sand, cement etc. Cement and sand should be in ratio of 1:5.

3

5368

16104

... More
Execution of Straight/Derivation/EC Joint on Quad/PIJF Cables as per instruction by site engineer.

20

1223

24460

... More
End to end testing of all fiber of the optical fibred cable laid under above items 12 between station/cable huts. All required equipments, tools and plants shall be arranged by the contractor. Five nos. of print out of traces in folders of OFC parameters/ results, The per kilometer link loss shall be as per the policy /technical circulars issued by the railways from time to time.

8

14387

115096

... More
Installation of maintenance free earth electrode for maintenance free earth spec of RDSO/SPN/197/2008 or latest.

3

5540

16620

... More
Fixing of 10/12/20 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

6

381

2286

... More
Manual horizontal auger boring/drilling of 100mm dia Horizontal Bore across the Railway Track/ Across Road at LC gates by Boring method at a depth of 1.65mm from the ground level/ ground level to be considered ignoring the bank height of the bank/road and insertion of HDPE/DWC/GI pipes etc., as per the instructions of Engineer in charge at site.

500

782

391000

... More
Horizontal direction drilling/boring without damage of surface road using Auger 16 Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1500 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. The HDD with or without HDPE pipe as per direction of Engineer In Charge.

18000

603

10854000

... More
Fixing & laying of 100 mm dia GI pipes and parapet wall/roof of culverts, including masonry work at both ends with contractors own material and bending of the pipe at the both ends etc. as per directive of Engineer in-charge, Perforation should be done before laying of GI pipes.

500

190

95000

... More
Fabrication of EC socket box, assembly and erection of fabricated assembly at the location indicated in the route chart and as per direction of Engineer in charge. This includes cutting of rails to required size, supply and welding of GI Pipe and base plate, fixing of EC Socket box, transportation of material to site, digging of pit and erection of whole assembly at site. The work also 18 includes the termination of 6 Quad/PIJF derivation cable on the strips of 6 pin EC socket inside emergency socket box. The fabrication of EC Socket box shall be done as per Drg. No. SK/CSTE/C/97/16 & SK/CSTE /C/97/20. Rail post will be supplied free of cost at the SSE (Tele) C/SBI depot in full lengths. Note - In addition to above, the centre pins of EC sockets shall be terminated with a dedicated pair of 6 Quad cable (Derivate through the tail PIJF cable) in the entire block section so as to provide magneto/auto telephone communication from each EC socket. (All materials supply by contractor except rails).

15

3526

52890

... More
Painting of emergency socket assembly and rail post by applying one coat of red oxide as base color, and then painting the assembly as per zebra painting in white and black colors. The width of each of the black and white colors shall be 100mm. All paints used shall be with ISI mark.

15

557

8355

... More
Supply of paint & painting of telephone mark with indicating arrow, indicating the 20 direction of the nearest emergency socket on the RCC route/joint markers & EC socket box with kmtrs. All paints used shall be of Asian/Shalimar/Acolyte make with ISI mark. The indicating Arrow and all other writing work shall be done using black enameled paint with background painted Yellow. The work shall be carried out as per direction of site engineer.

250

104

26000

... More
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

20

3462

69240

... More
Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossing platform cutting etc.

300

32

9600

... More
Supply, Transportation & Installation of RCC cable route marker engraved and painted on both sides along the route every 50 mt. & route diversions as per site incharge instruction.

400

386

154400

... More
Preparation of cable Route Plan of buried S & T Cables using Radio Detector 8200 GS or 24 Similar model GPS Model and DGPS for per Trench per Km. For existing cables as per the instruction of Engineer in-charge. Submission of Report in KMZ File format. Soft Copy Only. In Open Line Section. (unit read as per trench km)

20

40752

815040

... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 25 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.

20

2507

50140

... More
Installation and wiring of SDH STM-4/ADMs primary drop insert multiplexers with all accessories, 19" rack with suitable stand/ platform made of MS angle/CC , power supply board FDF racks (Already installed) , DDF with miniature 'U' link type for 63E1s , runway ladder , etc. This includes connecting all pig tails, optical patch cords etc. to the SDH equipments. This also includes connecting the SDH and primary MUX equipment with all interface cards to the 48V Bus including supply of wires and connectors , termination of all E1 on DDF , taking PVC cable over runway or a wall and termination of VF interface circuits to the krone type. MDF at both the ends (Two Nos. 100 pair's 26 krones) Krone type DP (One No krone 100 pairs) for 30 circuits derived from Primary MUX to be supplied and provided. All other miscellaneous materials including switch board cable & PVC conduits from 19" rack up to way station equipments, stand for 19" rack , power supply board with 15/5 Amp. Plug & socket (2 Nos.) etc. should also be provided on this rack for testing and isolation of faults. Any other materials required to comply this item shall also be supplied by the contractor. This item also includes fixing krone MDF and termination of VF/DATA interface circuits inside the VF termination cabinet, wiring of U link panel inside the transformer bay. This also includes taking PVC cable on channels/ladders and terminating at both the ends. Required 50/100 pr. krone MDF shall be supplied by the contractor along with current and voltage protection arrangements for all the circuits.

1

21149

21149

... More
Installation, wiring, testing , commissioning of Drop / Insert Mux with E1 interface cards connection to 48V bus bar & termination of VF/Data interface circuit to the crone MDF in already installed 42U EURO Rack. This includes termination of PVC cable at both ends, taking PVC Cable over runway or on the wall. This also includes supply of PVC cable of conductor size 0.63 mm. (ii) Testing and commissioning of STM-4/D/I Mux Equipment installed vide item no. 1 & 2 above using NMS as per as per approved test protocol. The work includes submission of all technical documents, manuals. All miscellaneous items required for the final testing and commissioning for the system will be supplied by the contractor.

-

-

27

... More
Installation, wiring, testing and commissioning of way side equipment and telephone on the rack as per consignee in charge.

1

2732

2732

... More
Supply and installation of rack mountable LIU along with all accessories suitable for 24 F mono mode fibre. LIU supplied should be of slider type and as per instruction of Site engineer.

5

4467

22335

... More
Installation wiring commissioning of 48 volt / 50 Amp SMPS based charger along with the power supply wiring from Power room to equipment room in ladder, wire, SPD, MCB, ladder and any other material required for installation will be arranged by the contractor.

1

4264

4264

... More
Installation and wiring and commissioning of maintenance free VRLA cells at each 31 station. Note:- The rate quoted shall be including the cost of DC bus bar of 48V DC /Power wire suitable stand etc., connection of power supply to the equipments. All the wiring shall be done with the suitable gauge of power wires through suitable casing / capping as per the instructions of railway engineer's. All the materials required for this item shall be supplied by the contractor.

1

2120

2120

... More
Supply & Installation of Power Supply Distribution Box along with MCB /Fuse as per specification and requirement given by Site Engineer, Make-3M, SNATEL, ABB, or .similar

1

21625

21625

... More
Supply, Installation, testing, and commissioning of surge protection cum safety device (Class B + Class C) suitable for single phase for Telecom Equipment as per RDSO specification No. RDSO/SPN /TC/98 /2011, Rev. 0 with Amendment No.1 or latest.

1

18685

18685

... More
Installation and commissioning of 25W radio at station building. This includes erection of mast, antenna, charging of the battery with all contractor's materials. power supply unit and antenna with support pipe.

1

8054

8054

... More
Installation Testing and commissioning of different types of speakers with hanging arrangements and clamps on cover shed/ poles as per directions of Field Engineer.

26

770

20020

... More
Supply, Installation, Testing, and commissioning of Two zone Power Amplifier set of 240 Watt, 230V AC /24V DC confirming to RDSO/SPN /TC/63/2006 Rev 0.0 or latest amd. Ahuja or similar make complete with one set of Microphone, Cord, and Stand.

1

19217

19217

... More
Installation, testing, fixing wiring and commissioning of PA system complete in all respect including material required for installation, testing, fixing and commissioning.

1

5126

5126

... More
Supply, Installation, Testing, and Commissioning of GPS-based double-faced platform Clock as per RDSO/ SPN/ TC / 62 / 2008 Revision 4.1 or latest along with required SMPS charger and battery Backup of at least 180 Mins, along with other accessories.

3

47480

142440

... More
Installation testing and commissioning of Universal Fare Display System for PRS/UTS/Thin Client with all required accessories and configurations.

1

306

306

... More
Supply & Installation of 4 port -48 DC Router 2 LAN port & 4 x Mbps G-703 port as RDSO specification No. RDSO/SPN/TC/54/2008 or as per latest specification.

1

280087

280087

... More
Installation, testing and commissioning of CDC set as per RDSO Specification No. RDSO/ SPN/ TC/ 108/2019 Ver 1.0 with Amdt -1 or latest

1

11985

11985

... More
Installation, testing and commissioning of Platform Data Controller as per RDSO specification no. RDSO/SPN/ TC/ 108/ 2019, Ver. 1.0, Amdt.- 1 or latest and as per instruction of Engineer in charge. All required material [except CDS/PDC] for fixing the CDS/ PDC are to be arranged by the contractor. Installation and commissioning of Platform Data Controller (PDC)as per instruction of site engineer.

-

-

42

... More
Installation, Testing, and Commissioning of Double Faced Coach Guidance Display Boards in the Covered area with complete accessories as per RDSO/SPN/ TC/108/2019 Ver.1.0 or the latest

24

3015

72360

... More
Installation & Commissioning of double face coach guidance display boards/Speaker as supplied under schedule C1, in open area. It includes Supply, hanging arrangement of coach indication board/speaker along with hood [Cover shed] in open space, [without shed feet's long [1:3:6] I area] 44 100 mm mm dia [OD] & 15 G.I. to be erected with concrete foundation of 3 Feet deep from platform level and on the pipe, an angle to be fixed on G.I. pipe as per site condition. Contractor to supply all required materials with G.I. pipe & G.I. sheet of 2 ft x3 ft which should be placed on the top of the board in open space as per approval of site engineer with angle fastening and crow guard. Supply of G.I. pipe included in this.

48

5821

279408

... More
Installation, testing, and commissioning of 5-line single-face indoor display boards as per RDSO/SPN/TC /108/ 2019 Ver.1 0 or the latest.

1

21070

21070

... More
Installation & commissioning of Single line double faced Train Arrival/Departure Display board. This includes all required accessories required including hanging structure for fixing arrangements to commissioning the item.

6

11499

68994

... More
Installation, testing and commissioning of Train information At A Glance display board with all accessories as per RDSO specification no. RDSO/ SPN/ TC/ 108/2019 Ver.1.0 with Amdt -1 or latest.

1

56524

56524

... More
Laying and drawing of CAT-6, Power Cable, OFC in casing & capping /Rigid PVC conduit through wall/structure of platform shed/ underground through GI/DWC/HDPE PIPE.

4220

9

37980

... More
Cutting of the platform surface (Tile/Slab) for a depth of 25cm and a width of 10cms 49 and refilling/ Reconditioning/ Concerting /Repairing the platform after laying HDPE pipe and cable. Cutting should be done with marble cutting machine in proper manner and restore the same as before in such a manner that aesthetic of the platform is not disturbed.

600

235

141000

... More
Supply , Installation & Testing of 1 KVA online UPS , Backup of 120 minutes, warranty 2 years, Battery Type-SSMF-VRLA Make Mictrotek or Similar.

1

38360

38360



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.