Western Railway Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Western Railway - WR Tender

Works
Electrical Cables And Wires
Electrical and Electronics
Ireps
Opening Date30 Dec 2024
Closing Date27 Jan 2025
Tender Amount₹ 1,76,05,276.78 
Notes
Download

Costs

Summary

Alteration/modification In Electronic Interlocking System In Connection With Provision Of Full Length Shunting Neck In Halvad By Extending The Dead End Of Line No. 4 By 950m Towards Gadhidham Yard And Chandlodiya -khodiyar Section - Construction Of 4 Lane Road Under Bridge In Lieu Of Lc No. 3 At Km. 508/8-9 Of Ahmedabad Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of Special type Point contactor relay QBCA1, AC immune, 24 DC biased, 2HF,4B complete with plug board, retaining clip & connectors. conforming to BRS 943.

6

6437

38622

... More
Relay QNA1, AC immunized 8F/8B, 12F/4B, 24VDC along with plug board, retaining clip and connectors. Conforming to BRS 931A, IRS:S60, IRS:S34 & IRS:S24.(No. of each configuration will be decided by Engineer In-charge)

50

5320

266039

... More
Relay QSPA1, 24VDC, Slow to pick up, 8F.4B along with plug board, retaining clip and connectors. Conforming to BRS: 933A, IRS:S60, IRS:S34 & IRS:S23.

2

4919

9838

... More
Track relay QTA2, AC immunized, 9 Ohm, 2F/1B, along with plug board, retaining clip and connectors conforming to BRS:939A, BRS:966, IRS:S34 & IRS:S23.

2

5823

11646.92

... More
Key Lock checking Relay (KLCR) work on 24V DC, AC immune with 1 K-50 neutral relay contact configuration 4F/4B with one key and one ward, RDSO Specification No. RDSO/SPN/219/2016(Ver. 1.0) or latest IRS:S:23, IRS:S@58"44@ IRS:S:46 Make INTEGRA.

-

-

8

... More
Supply of Screw less mounted 2.5sq.mm.4-wire front entry, Two in put Two out put, 9 Disconnected Cage Clamp Terminal block for test and measurement as per site requirement. as per RDSO Spec. No. RDSO/SPN/189/2004. The procurement should be done from RDSO recommended sources. The colour will be decided by Engineer - in - Charge.( Prefrebly In BLUE, Red & Grey Colors in the ratio of 1:2:3) 10

1000

62

62250

... More
Supply of End Plate for above item 9, 10mm/0.0394 in width as per site requirement. 11

160

11

1875.2

... More
Supply of End Stopper for above item 9, 2.5mm/0.091 in thick as per site requirement.

160

11

1840

... More
Supply of Carrier Rails for above item 9, 35mmx7.5mm,1mm/0.039 in thickness un- slotted type as per site requirement

40

119

4790.4

... More
Fuse auto changeover system for use in Railway Signaling System as per 13 RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover unit comprises 32 nos. of external Non -Deteriorating Type or 'G' type fuses from 0.6Amp to 4Amp capacities which are used in signaling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card.

1

32562

32562.2

... More
Fuse auto changeover system for use in Railway Signaling System as per 14 RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover unit comprise 24 nos. of external Non -Deteriorating Type or 'G' type fuses from 4Amp to 10Amp capacities which are used in signaling circuits. System shall have 6 cards with monitoring arrangement of 4 fuses in one card.

1

54218

54218.46

... More
Position Light Shunt Signal Unit Complete, with offset bracket, hood, Cover etc. as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item).

2

4180

8360

... More
Position Light Shunt Signal Unit Complete with Post(made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS 1239 Pt. 1/1990, Base Hood, Cover etc as per Drg. No. SA- 23840 suitable for LED Signal Lighting Unit.

2

5006

10013.44

... More
Desk type Electronic Mageneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments.

2

3623

7246.2

... More
Pad locks Godrej make, Hardened Nav -Tal 7 lever, 65mm dia with common key or similar product having same feature & technical data.

10

197

1979.9

... More
SS Location box made of Spl. Grade SS 304 of size as per drg. No. DRM/SG/948 dt. 26.04.2011 (Signale app. Case). Manufactur's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.

10

88348

883481.2

... More
SS Location box made of Spl. Grade SS 304 of size as per drg. No. DRM/SG/945 dt. 03.03.2011 (Half app. Case). Manufactur's certificate in regard to grade of stainless steel and its protection level shall be submitted at the time of supply.

3

66055

198165

... More
ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.

1300

73

96148

... More
Supply of Phenolic Laminated sheet P3 Grade of size 1220mm x 1220mm x 12mm. as per Spec. No. IS2036 of 1995 or latest.).

13

4863

63221.99

... More
Supply of Double Walled Corrugated (DWC) pipe with associated collars etc.as per 23 RDSO specification No. RDSO/SPN/204/2011 Ver. 1.0 and IS 14930 Part I & II or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size120mm outer dia,& 103.5mm inner dia. The required coupling arrangement should also be supplied.

10

2018

20181.4

... More
Supply of Medium class G.I. Pipes as per specification IS: 1239 (Pt.I)-1990 or latest 100mm dia. ( int. dia) 3.65 mm+/- 10% thick with coupling G.I. Pipes shall have ISI mark on it and contractor should submit manufacturer's test certificate of G.I. Pipes. Make- Tata, Jindal, Surya or Asian. 25

100

634

63402

... More
Earth Electrode as per Drg. No. CSTE / 6091

30

3594

107841.6

... More
Track feed battery chargers, 110V AC input, 2 to 6V DC output; as per Specn.No. IRS.S 89/2013 with latest amendments. Charger shall be suitable for charging 80AH battery.

2

3577

7154.72

... More
Adjustable Track Feed Resistance disc type 30ohms as per RDSO Drg. No. SA20166/M (Adv) with latest amendments (with Phenolic moulded base).

2

957

1915.94

... More
Track Lead Junction Boxes as per C.Rly Drg. No.RST 11509 made from fiber glass along with terminal blocks.

8

1060

8486.08

... More
Choke Coil for Single Rail Track Circuit on 25 KV 50 Hz AC Electrified Section as per Spec No IRS S 65/1983 with latest amendments.

4

1846

7387.44

... More
Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. This also includes supply of equivalent no of ND type Fuses of 2A capacity as per specification IRS S-78/92

8

140

1120.08

... More
D type fuse link non indicating type low voltage non detonating, capacity 2A/6A/10A as per specification IRS:S-80/92 or latest.

70

32

2284.1

... More
Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar).

90

61

5560.2

... More
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch bracket, Split-Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement)

2

1521

3042.4

... More
Wire Single core multistrand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm) as per IRS:S-76/89 (Amd.3) or latest. Wires colours and quantities shall be specified by Engineer-in-charge.

2

5596

11192

... More
Flexible cable (Power wire), multi-strand copper conductors cross section (1x6Sq.mm). (85 conductor each diameter 0.30+/-0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/Km and test parameters are as per IRS(S) 76/89.

1

43656

43656

... More
PVC insulated Railway Signaling multicore Indoor Cable 1 x 40 x 0.6 mm conforming to IRS 76/89 (Amd 3 ) or latest.

1

109464

109464

... More
PVC insulated jumper wire of all colours to Spec No IRS(S):76/89 (Amt 3) or latest: 1x0.6 mm (Colour code will be decided by Engg incharge)

1

2720

2720

... More
PVC insulated jumper wire of all colours to Spec No IRS(S):76/89 (Amt 3) or latest: 1x1 mm (Colour code will be decided by Engg incharge)

1

6380

6380

... More
Supply of Half round RCC pipes of 150mm internal dia (1Mtrx2 Nos) along with collars as per IS No. 458/2003 of NP type. 40

1500

346

519615

... More
WARNING TAPE. 1MM x 150MM x 1 MTR "WARNING: S&T cable below" orange Colour.

3000

24

72630

... More
Cable Route Location/Trace Set suitable for detecting under ground armoured optic 41 fiber cable (OFC) and signaling cable with LCD graphic. Display active/passive modes and depth range 4M-10N the set shall consist of the following (1) Receiver seek tech line locator/cable avoidance tool- 1No. (2) Transmeter/Signal generator complete with earth stake and connection leads. 01No. (3) Inuctive signal clamp. 01 No. (As per Technical Specification Chapter.

1

602975

602975

... More
Supply of Quad Cable conductor %u2019s Earth Resistance Sensing Unit, Microcontroller based for 24 nos. conductors with metering facility for one conductor at a time as per attached technical specification.

-

-

42

... More
Modification/Alteration/augmentation of existing electronic interlocking (EI) system (ANSALDO make) of provision of full length shunting neck in Halvad by extending the dead end of line no. 4 by 950m towards Gadhidham yard as per RDSO specn No. RDSO/SPN/192/2019 /ver.2.0 as per approved Signaling Plans and Selection Table/Locking Table of stations (for phased doubling. LC removal etc.), technical specifications & special conditions of contract.This includes supplies necessary for alteration/modification in VDU's software. This also includes supplies necessary for earthing the modified/altered/augmented EI those needed for rewiring external data-logger and fuse alarm system.Item includes preparation of Selection Table, Locking Table Control Panel and Route 1 Section Plan, Wiring Diagram and other diagrams (other Technical documents if any) based on Signalling Plan supplied by Railways.This also includes supply, installation of interfacing relay and accessories. All internal wiring i.e. wiring from Relay to Relay, Relay to EI, Relay to CT Rack will be done by contractor as per railway practice. Completion Documents as per Technical Specication Section IV of the contract. Note-1:- Material required (other than scheduled items) to be supplied by contractor rm for installation and commissioning of In built block working. Note-2:- This also includes corressponding changes/alteratins in datalogger software. Note-3:-This schedule item also includes removal of LC -64 work in Halvad Sukhpur section . Note-4:- After issue of LOA and before signing of Contract Agreement, successful bidder shall submit an undertaking/MoU from RDSO approved EI OEM to confirm compliance with extant RDSO guidelines and to meet contract specific requirements.

1

7274236

7274236.03

... More
Modification/Alteration/augmentation of existing electronic interlocking (EI) system (ANSALDO make) of Chandlodiya Khodiyar Section- Construction of 4 lane Road under Bridge in lieu of LC No. 3 at Km 508/8-9 as per RDSO specn No. RDSO/SPN/192/2019 /ver.2.0 as per approved Signaling Plans and Selection Table/Locking Table of stations (for phased doubling. LC removal etc.), technical specifications & special conditions of contract.This includes supplies necessary for alteration/modification in VDU's software. This also includes supplies necessary for earthing the modified/altered/augmented EI those needed for rewiring external data-logger and fuse alarm 2 system.Item includes preparation of Selection Table, Locking Table Control Panel and Route Section Plan, Wiring Diagram and other diagrams (other Technical documents if any) based on Signalling Plan supplied by Railways.This also includes supply, installation of interfacing relay and accessories. All internal wiring i.e. wiring from Relay to Relay, Relay to EI, Relay to CT Rack will be done by contractor as per railway practice. Completion Documents as per Technical Specication Section IV of the contract. Note-1:- Material required (other than scheduled items) to be supplied by contractor rm for installation and commissioning of In built block working. Note-2:- This also includes corressponding changes/alteratins in datalogger software. Note-3:- After issue of LOA and before signing of Contract Agreement, successful bidder shall submit an undertaking/MoU from RDSO approved EI OEM to confirm compliance with extant RDSO guidelines and to meet contract specific requirements.

1

3208322

3208322

... More
Erection of relay racks, IDF with scaffolding arrangement, Cable termination rack with suitabale grounding arrangement at station. Insulators, grouting bolts, tripods to be supplied by Contractor. The item includes fixing of tag blocks on relay racks, CT rack Fixing of WAGO/phoenix 3 terminals on CT racks on 3mm laminated hylum sheet or as per approved arrangement prescribed by site engineer and drilling holes in the hylum strips as required. This also includes supply & erection of cable supporting laddrs on the back side. This includes supply and fixing of 3mm laminated hylum strips, square bars for fixing of WAGO/PHOENIX terminals & for supporting outdoor cable coming from cable pit. PVC Coated Sting Roads should be used to support the cables on CT Rack. This includes laying of cables coming from cable pit to CTR through ladders as per instructions of site in charge.

1

9337

9337.43

... More
Fixing of KLCR relays in field in half location boxes/Almirah. Item includes supply and fixing of MS sheet and wiring of push buttons and LEDs for KLCR circuit. The KLCR relays, push 4 buttons, LEDs to be fixed on a MS sheet of min. 3mm in the half location box. The MS sheet should cover the full length and breadth of the half location box/Almirah and can be in two pieces of approx 48cm x 46cm and 80cm x 46cm. The first piece to be fitted on top and will contain the KLCR relays, LEDs and push buttons. The second piece to be fitted below the first piece to divide the two halves of the location box. (Supply of KLCR relays covered in Schedule A).

1

1624

1624.42

... More
Installation,Wiring testing and commissioning of Fuse Auto change over system 5 (FACS). This includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/LC gate where installation of relay racks not feasible.

2

969

1939.3

... More
Excavation & Casting of CC foundation in the ratio of 1:3:6 for Shunt signal post as per 6 drg. no.CSTE/6090 using std. size holding down bolts nuts for erection of colour light signal post. Items include excavation, ramming, curing and plastering with 1:4 cement and sand mixtures. (Aggregate not exceeding 3.8 cm). Aggregate cement, sand and holding down blots, nuts to be supplied by the Contractor.

2

5830

11660.24

... More
Erection of Position Light Shunt signal with Base, Post, Signal unit and fixing of Number Plates. The work shall be done as per instructions of Rly engineer at site. 8

2

1951

3902.36

... More
Erection of Position Light shunt signal on Offset bracket on main signal.

2

2224

4448.18

... More
Installation of NE type Full apparatus case and casting of CC foundation in the ratio of 1:3:6 for NE type apparatus case as per drg. No.CSTE/5074 using std. size holding down bolts. Item include excavation, ramming, curing and plastering with 1:4 cement and sand mixtures. This includes filling up of hollow space in the foundation both sand and top surface, plastering. (Aggregate not 9 exceeding 3.8 cm) Plastering should be done to level the surface on all sides upto 75 mm below the ground level after the cable is taken inside the apparatus case. Aggregate, sand, holding down bolts and cement to be supplied by the contractors. (NOTE: Due to local conditions in very special circumstances if the size of the above items required to be increased/decreased, the extra payment/deduction for variation of the CC work shall be calculated and paid on volumetric basis as per rate below.) This includes supply and fixing of telephone sockets, location lamp holder and making arrangement for pad locking of location boxes.

10

8868

88681.4

... More
Installation of NE type Half apparatus case and casting of CC foundation in the ratio of 1:3:6 for NE type apparatus case as per drg. No.CSTE/5074 using std. size holding down bolts. Item include excavation, ramming, curing and plastering with 1:4 cement and sand mixtures. This includes filling up of hollow space in the foundation both sand and top surface, plastering. (Aggregate not 10 exceeding 3.8 cm) Plastering should be done to level the surface on all sides upto 75 mm below the ground level after the cable is taken inside the apparatus case. Aggregate, sand, holding down bolts and cement to be supplied by the contractors. (NOTE: Due to local conditions in very special circumstances if the size of the above items required to be increased/decreased, the extra payment/deduction for variation of the CC work shall be calculated and paid on volumetric basis as per rate below.) This includes supply and fixing of telephone sockets, location lamp holder and making arrangement for pad locking of location boxes.

3

6689

20067

... More
Preparation of SWR Diagram on standard tracing paper of 95 grams for each station. Corrected version of SWR plans after checked & approved by Rly's 25 Ferro copies will be supply for each of the plans. (a Supply and preparation Station SWR diagram(Tracing).

1

8017

8017.19

... More
Cement concrete work for miscellaneous items in the ratio1:3:6. Item includes excavation, ramming, curing and plastering with cement sand mixture (aggregate not exceeding 3.8 cm). Aggregate, cement and sand to be supplied by contractor.

5

4110

20552.7

... More
Providing brick masonary in the ratio 1:6 cement & mortar including plastering with 1:4 13 cement and sand mixture both sides, 20 mm thick each with contractors own 2nd class brick, including exavation, curing, grouting, bolting etc wherever required. Brick, sand & cement to be supplied by the contractor.

1

2224

2224.35

... More
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.

1300

13

17095

... More
Fabrication and fixing of Phenolic Laminated sheet P3 Grade in Full apparatus case NE 15 type of size 10/12/20mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site.

10

2568

25683.6

... More
Fabrication and fixing of phenolic laminated sheet P3 Grade in half apparatus case NE 16 type of size 10/12mm thick in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site.

3

1027

3081

... More
Digging of 1.0 M deep and 0.3 M wide trenches in all type of soils including soft rock as 17 per cable route plan, back filling after laying of cables. This includes clearing of roots of trees, bushesand temporary obstruction. Ramming of soils and planting of cables markers at every 30 to 50mtrs as well as where direction of trench changes. Where Digging of 1.0M depth is not possible or the same is reduced and accepted by engg. incharge of the work, payment shall be decreased proportionate to the depth excavated compared to 1.0M. Any dry stone pitching disturbed during the work shall be restored back to the original conditions by the contractor with own materials and labour.

1500

310

466410

... More
Manual Horizontal Auger boring for crossing of Road/track at depth of 1.0m from ground level/ bottom of rail flange including insertion of 100mm dia (with thickness 3.65mmm) DWC pipes/coupling etc all complete as per direction of engineer incharge.

550

1274

700920

... More
Laying of S&T Cables of various cores and types/pairs/quads in trenches/GI/RCC/trunking etc. This also includes laying of cables in track crossing and road crossing. Item includes provision of labels of colored plastic adhesive tapes on each cable or any other 19 identifiable material to give the cable number. Cables will be supplied by railways. However transportation of same from the divisional stores/consignee stores to the work site shall be done by the contractor by his own means. (Cables will be meggered before and after its laying by contractor under the supervision of railway representative and he will submit the meggering report of each testing.) Length of cable includes the length of the cable coiled for termination purposes.

39000

9

380250

... More
Supply and placing of trunking and capping (RCC duct) of 300mm width & 700mm length as per DRG No. SDO/Cable laying/007(annexure-10 or latest) as detailed in document no. RDSO/SI/G/2010 Ver.1.1 or latest on guidelines on signalling cable laying.

300

1190

357276

... More
Transportation and Placing of DWC/GI/ RCC pipe in trench/Auger bore for track / road crossing protruding equally outside the rail/road edge on either side. As per instruction by Engineer in charge.

60

34

2065.2

... More
Fixing of B class GI pipes (ISI mark) 100mm dia or other dia, troughing on culverts 22 bridges & any other loc. etc. including material for fixing arrangements as directed by Engineer in charge.(Supply of GI pipes, troughing is covered in Sch A.) Other dia pipes will be supplied by Railways where felt necessary by the Engineer-in-charge.

100

205

20530

... More
Supply and installation of RCC cable route markers engraved in one side and painted on both sides along the route every 50m and route diversion as per DRg.No.4014/00/CC4 or latest.

35

447

15679.3

... More
Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc at both ends. Both ends of a cable core terminated shall be counted as one terminal. The item includes dressing of cables, making wiring tree etc.

2500

5650

5650

... More
Installation of earth electrode as per std. practice and connecting it to equipments to be earthed. This item includes digging of pit in earth 3 m deep & fixing earth electrode pipe, casting 25 of cement concrete enclosure & cover as per Drg No. S&T/Tender/27.Soil treatment to be done as per std. practice. This item includes provision of earth lead wires and soldering of lead wires. The other end of the wire is to be connected to block equipment, power equipment, cable sheath, signals etc. as per site requirements. 7strand GI wire shall be used as earth lead wire. (Supply of earth electrode is covered in Sch. 'A').

30

1734

52030.8

... More
Fixing of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg No. SA 91 51-52 or 9710 or 9161 as per section of rails used. Item includes fixing switch extension bracket, providing insulation for switch extension bracket, fixing ground connection, adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes : (i)Complete material for installation like ground-connections, switch extension brackets, point insulation material, I pipes, wiring materials, various fixing nuts & bolts 26 including castle nuts, spring washers (ii) All smithy & fitting works required at site for complete installation. (iii) Installation of gauge tie plate & providing insulation for gauge tie plate (Insulation in William Stretcher Bar will be Provide by Railways). (iv) Wiring inside the point machine, insertion and termination of tail cable in point machine and junction boxes / location box /cable hut as per extent practice on WR and the instruction of Railway Engineer at site. (v) Supply and fixing of suitable size GI pipes with flange for taking cable into point machine. Note ; The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point layout i.e. 60 Kg. / 52 Kg / 90R as per yard layout. Electrical Point Machine and M-6 / Screw less terminals will be supplied by Railways / covered in Schedule separately

2

22982

45965.18

... More
Erection, Fitting and Rail connection of Track Lead Junction Box on two supports 27 (M.S.angle) with contractor's fixing material and PVC jacketed wire for track lead connection includingangles of size 40 x 40 x 5 mm 1200 mm length. This will include drilling of holes for track lead/side connections on rail. The work shall be done as per Drg. No. S&T/Const./JHS/T 115 & instructions of Rly engineer at site. This includes provision of double bonding/PVC jacketed wire for each supply i.e two for positive and two for negative supply.

8

1327

10620.96

... More
Charging of 2V/80AH Lead Acid Batteries with contractors own battery grade sulphuric 28 acid and distilled water with minimum two charge -discharge cycles, installation of charged batteries in groups & their connection & wiring. The work shall be done as per extant practice of W.Rly & measurements of intial charging shall be recorded jointly by contractor & Rly's site-in-charge.

6

406

2438.28

... More
Design of circuits and plans to suit layout given in the signaling plan of the Route setting type panel interlocking. All plans and wiring diagram shall be prepared on Auto cad Drawing and supplied with CD. This will include supply of Control cum indication panel diagram, Route section plan, square sheet, wiring diagrams, Relay rack/Relay arrangements, Bus bar details, Fuse analysis, contact analysis, Power panel diagram, IPS wiring diagram, Auto change over diagram, Power equipment arrangement with program switch, Block circuit wiring diagram, Digital Axle counter wiring diagram and all other relevant drawings. Note: The contractor shall initially supply 2 sets of documents (Paper Prints) for approval of Railways. Railway will return one set to the contactor duly approved with alterations/corrections, if any. The contactor shall incorporate Railways' 31 alterations/corrections/comments, if any in the tracing & CD without any deviation and submit all the tracing & CD without any deviation and submit all the tracings and Final CD complete with all respect for Approval of Railways. After Approval of Railways on the tracings, the contractor shall submit 3 sets of final approved diagrams to the Railways within 15 days. He shall ensure the each sheet has a block for signature of railway official as well as a block for signature of the firm. The name of the work as given by Railways shall be written on every sheet under the work column. All the drawing shall be supplied in a good quality folder for each station. Fault diagnostic chart: Important aspect of trouble shooting & adjustments along with parameters & its range shall be prepared in colored A1 size in glossy paper & frame to be displayed in Relay Room. Above chart shall be provided in the Relay Room & The JE/SSE/ESM duty Room at least one day in advance of commissioning. Contractor shall obtain the approval of railway before supplying the same. 5 copies of the same shall be submitted tof each station.

1

123206

123206.83

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- charge. Epoxy paint will be supplied by Railways.NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974). TLJB

-

-

33

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in- 34 charge. Epoxy paint will be supplied by Railways.NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974). Point Machine with ground connections complete (Point Machine with Black enamel only outside and ground connections with Red Oxide)

2

119

239.48

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. Full Case 36

10

133

1337.5

... More
Supply, fabrication & fixing of signal number plates as per site incharge.

5

372

1862.15

... More
Hiring of JCB machine(in good working condition for leveling and dressing ground/dismantling structures including disposal of debris through dumpers etc.with contractors 37 labour,JCB machine,machine operator,fuel etc.The contractor shall arrange road permit for vehicle for all the state of operation,as per instructions of engineer in-charge and vehicle shall not be more than three years old.Payment shall made for actual working hours at site. (i) 01 JCB machine for approx 4 to 5 Hrs.per day for 30 days.01x5Hrs x 50 days=250 Hrs. (ii) The time period and workingdays may be decress/increase as per site condition.The payment shall be made as per actual working hrs.

150

449

67417.5

... More
Supply and installation of Failure analysis system with accessories. (Specification attached in Technical specification Section IV).

1

62570

62570

... More
Wiring, installing of Magneto/DTMF telephone in ASM office, at locations, Relay Room, Point locations on both directions and siding Point Control locations as per instructions of Engineer-in- Charge for traffic purpose.

2

102

205.7

... More
As and when required by the Engineer in charge arranging/providing of labours for various safety related works such as protection of track etc. with contractors T&P,equipment etc.Scope of work as furnished in the tender and directed by the Engineer in charge

900

568

511425

... More
Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing 41 Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit . After jointing the cable through test such as insulation test, continuity, cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost.

4

1284

5136

... More
Supply & installation of RFID based Electronic cable/pipe marker 22.5 Cms. Dia. 1.5n depth range, 10 digits Hexadecimal 1D code, 101.4Khz frequecny. (Specification attached in Techanical specification Chapter).

50

2024

101240

... More
Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately)

3000

21

63870

... More
Earth work in bank or filling with contractor own earth of approved quality including procurement, leading with contractors own transportation with all lead and lift, unloading, breaking 44 clods, spreading same in layers of not more than 300 mm thikness, watering, rolling and compaction with contractors own mechanical roller & making bank to the compacted profile with dressing of all slopes & surface. (Inclusive of all royalty, taxes, octroi etc complete) as per specification & special condition of contract & as directed by Engineer incharge.

100

157

15700

... More
Shifting of Exposed cables. The item includes Removal of exposed cable from existing trench & laying the same in new trenches. Digging, Placing of capping/Half round RCC pipe covered separately.

5

5458

27291.75



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.