Western Railway Tender

... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Western Railway - WR Tender

Works
Electrical Works
Ireps
Opening Date8 Feb 2025
Closing Soon5 Mar 2025
Tender Amount₹ 13,14,82,746.12 
Notes
Download

Costs

Summary

Supply And Installation ,testing Of Material, Trenching, Laying Of 48x2 Ofc Each Side , Quad Cable And Blowing, Splicing, Jointing, Termination, Testing Of Ofc & Quad Cable

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    SnT_C_BRC_134_2024_25Tele-DYCSTE-C-BRC-S AND T/WESTERN RLY
  • Tender No

    SnT_C_BRC_134_2024_25Tele
  • Tender Authority

    Western Railway View
  • Purchaser Address

    -
Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of G.I. Pipes 100 mm dia medium grade engraved on pipe as per spec. no. IS 1239 part I of 2004 wirh latest amnd. with sockets and fittings. (other dia. Pipes shall be supplied by Railway) (Surya, Jindal, Tata,Apollo or Asian make ) -

800

1170

936224

... More
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating 5 type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.

200

1757

351516

... More
Supply of SPLIT DWC pipe conferming to RDSO/SPN/204/2011 Ver-1.1 or latest RDSO Specification , Non metallic, corrugated, multiwalled, normal duty, pliable, without protection agaist chemical attack and Non Flame propagating in 2 meter length of size 200mm outer dia & 175 mm inner dia( Permitted tolerance in dia=+/- 2mm) (TWO Half round pipe constituting on split pipe)

1500

292

438975

... More
Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/ 2004. With latest amendments. WAGO make

-

-

75567.4

... More
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. 9

1000

16

16490

... More
Road Measuring Cycle,made of Aluminium with 05 digit counter,foldable with bag. 10

2

4498

8997.32

... More
Office Chair makes Godrej CH-7B or similar of reputed brand. 11

16

2649

42384.32

... More
Office Revolving Chair Godrej Make Model No.9u02r Bravo Or Similar of reputed brand.

12

8107

97293.96

... More
"Office table with laminated top with three drawers on left hand side and one locker on the right hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 or Similar of reputed brand. "

8

15562

124498.16

... More
"Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand. "

8

17004

136038.08

... More
Supply of Thermo shrinkable joint kit as per RDSO spec no. IRS TC 77/2010 Rev-2 or latest suitable for 2T joint RTSF3 suitable to 6-quad cable of spec no. IRS TC-30/2005, Ver-1, Amd-4 with latest AMD..

180

3234

582125.4

... More
Supply of Thermo shrinkable joint kit as per RDSO spec no. IRS TC 57/2006 Rev-0 Amd- 1 suitable to 10/20/50 pair PIJF U/G telecom cable of spec no. IRS TC-41/97, Amd-2 with latest Amd. Size of the cable will be advised by consignee in charge. 16

40

2504

100181.6

... More
VF Transformer 470/1120 as RDSO/SPEC/TC/22/76 with latest Amd.

120

573

68804.4

... More
Supply of 4/2 wire portable emergency control telephone as per IRS -TC- 75/99 (Amd-2) with latest amendments along with std. length cord and 6 pin plug as per spec no. IRS TC 42/87 (Amd- 1) or latest

10

2796

27968.4

... More
Supply of 20 pairs CT box with wago terminal for termination cables.. The Box is rugged, weatherproof, and highly reliable and uses Universal Test Disconnect Terminal Blocks of PHOENIX OR WAGO Make. Epsilon or similar make as approved by Railway.

20

2054

41087.8

... More
Supply of 12pairs CT box with wago terminal for termination cables.. The Box is rugged, weatherproof, and highly reliable and uses Universal Test Disconnect Terminal Blocks of PHOENIX OR WAGO Make. Epsilon or similar make as approved by railway.

24

1274

30596.88

... More
Supply of G.I. Pipes 80 mm dia medium grade engraved on pipe as per spec. no. IS 1239 of 204 with latest amnd.with sockets and fittings. (other dia. Pipes shall be supplied by Railway) (Surya, Jindal, Tata, Apollo or Asian make).

300

550

165150

... More
" EMERGENCY 6 PIN SOCKET AND BOX IRS:TC:42/87 (Amendment Slip No.1) BOX - Conforming to RDSO DRG. NO. TCA-20060 (ADV) make-Epsilon or similar Make as approved by Railway."

60

2598

155880.6

... More
Supply of 6 Pin EC Socket Plug & Socket flat type as per IRS TC-42-87 ver-2, Amd-1 or latest.Make -Epsilon or similar make as approved by Railway.

20

538

10772.4

... More
Supply of Fiber Distribution management System rack mountable LIU along with all accessories suitable for mono mode 48 fiber armoured cable size 1 U -2 U size for termination of 2x24 Fibers.supplied shuld be slider type .48 fiber complete loaded Euro adoptor,pigtaial, etc,as per instruction of site engineer.3M/RAYCHEM/ or Make/model to be approved before supply by railway.

-

-

23

... More
Supply of HDPE duct 40/33 mm as per RDSO Spec No RDSO/SPN/TC/45/2013 Rev 2 with lateast amendments or TEC GR No. G/CDS 08/02 NOV-2004 OR with latest amendments as 24 available. (suplly as per railway). For each Km of HDPE duct following items are to be supplied a) End Plugs- 2no b) Cable sealing plugs -2 no. (c ) Plastic couplers slip fit/push fit type - 2no d) End plugs to be provided along with drum -2 nos NOTE-Supply of duct in deferent color as per lateast laying polcy by HQ.and requirment.

230

60330

13876028.8

... More
Supply of 2x24 (48 fiber) fiber optic fiber splice (SJC) complete with all accessories as per TEC Spec no. GR/OJC/02/02.MARCH 99 TEC specs for 24 fiber OFC cable with latest amendment.R&M, 3M, Raychem or Similar make. 26

20

4393

87874.8

... More
End plug HDPE duct of size 40/33 mm dia.compatable to supplied duct.Inspection 27

1000

29

29610

... More
HDPE duct coupler of size 40/33 mm dia.compatable to supplied duct.Inspection

500

47

23695

... More
Supply and installation of Connectors/Pig Tail/Patch cords/ MC/ LIU/ Patch Panels, necessary accessories 24 fi b e r with termination/ splicing of OFC cable make R&M, 3M or Raychem,Systemax ,.Model make approved before supply.

30

13304

399141.6

... More
Supply of 19" covered racks, Vero President /Rittel or similar make having size of approximately 2.2 mtr.(42U) height X 600mm width x 800mm depth and duly approved by the engineer in charge of the work. The rack shall be suitable for all fittings for housing SDH equipment, 29 primary Muxes, DDF, MDF using krone module and other equipment like runway ladders etc. completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipment with only order wire telephone remaining outside the rack. as per railway requirment errection of rach including transportation should be done by contractor. with ladder up to 10 mtr.as specification .Before supply approved by railway. 30

12

37549

450599.4

... More
VHF Communication at Stn and power supply 31

-

-

554365.44

... More
Supply of U link panel 32 ways 32

24

1744

41874

... More
Supply of U link

400

137

54924

... More
Supply of PVC switch board cable, 10 pair twisted, conductor of size 0.63mm dia annealed copper conforming to TEC spe. No. GR-WIR-06/03 Mar'02 or latest.make-Delton/Birla similar.

3

41127

123382.56

... More
Supply of PVC insulated flexible 3 core x 2.5 sq.mm multi strand power cable as per specification no. IS: 694:1990 reaffirmed 1995 or latest.make-Polycab/finolex,/Anchor/Delton

2000

51

102120

... More
Supply of 100 pair Cable termination krone type box .Krone module suitable for 0.5 and 0.63 mm conductor for cable termination with locking facility.. as per Sepc. 36

12

4102

49224

... More
Supply of PVC insulated power wire 25 sq mm 37

1

136063

136063.55

... More
Supply of PVC insulated power wire 6 sq mm.

1

33366

33366.21

... More
Supply of 50 Pair Krone box with krone terminal .Krone module suitable for 0.5 and 0 .63 mm conductor for cable termination with locking facility.As per Spec.

6

1104

6628.62

... More
Supply of Digital transmission measurement setas per SPN - IRS TC: 43/87.with latest Amnd. APLAB make - Model 2031 / 2031A/or similar.

2

31951

63903.52

... More
Supply of Cross talk measuring set as per IRS. TC 45-88 with latest Amendment .Make Anu vidyut/Aplab or similar (Approved by site Eng. In charge).

2

30310

60620.3

... More
Supply of 4w emergency Control Room Equipment as per IRS:TC:61/93.Make -Epsilon /Anu vidyut or similar 42

1

35285

35285.34

... More
Supply of Tools kit for cable jointing in Bag as per spec.List

2

12456

24912.74

... More
"PCM TDM Integrated access device 1U heigt /19"" rack mountable; Optical module 43 integrated in the unit supporting dual core OFC and 2E1 one 100Mbps Ethernet Port; optical distance support to be 20 KM; unit consist one E&M module supporting eight 2W/4W (each port configurable); another one slot populated with FSX or FXO for hot line connection .Model : Make : MAPLE-4CS or similar."

10

166001

1660017.1

... More
Optical Module Card having SFP port for connectivity with suitable SFP module or EKT or optical to 4xE1 cinvertor suitable for 4E1.as per requirment of multipluxer MAPPLE -4 C or similar equipmet .which supply item above.

12

31089

373077.12

... More
Supply of Audio Interface Card for providing 10 FXO link per card suitable to be accommodated in PCM multiservice intigrated access TDM multiplexer supplied above.

3

34791

104374.26

... More
Supply of Audio Interface card for providing 10 FXS links per card suitable to be accomodated in PCM multiservice integrated access TDM multiplexer supplied above.

3

40745

122235.6

... More
Professional AC/DC clamp meter 3 3⁄4 Digit, true RMS measurement, complying to 47 IEC61010 and over voltage categories CATII600V, CAT III 300V, For measurements of DC/AC currents up to 1000 A, Voltage up to 600 volts, resistance up to 40 Mohms, Frequency up to 1 MHz with set of leads and Carrying Case. Model-DCM39A or equivalent higher version. Fluke/Stanlay Make.

4

23064

92258.76

... More
Supply of Digital insulation Tester 100V/250V/500V range Model: Rish insu 20 Make: RISHABH or Stanley or similar.

6

8582

51496.56

... More
Handheld Digital Earth Clamp Tester for clamp on earth/ Ground Resistance 49 Measurement up tp 1000 ohms. Accuracy 0.1 - 0.99 ohm : 1%; 1-49.9 ohm: 1.5%. Also measure current leakage up to 20A. No spines required for measurement. Model-DECT-2 or equivalent higher version, Motwane/Stanlay/Fluke make.

1

84885

84885.43

... More
Supply of Cable Route Locator as per specification cable Route Tracer /Locator with high power 12 W Transmitter for effective long distance location, 4 Active locating Frequencies depth range up to 9M,passive power frequency, current and resistance measurement in both transmitter 50 and receiver, super induction mode, with capability of electronic marker locating (both Passive and RFID) and sheath fault locating in a single equipment, allows software to be downloaded from website, weight less than 2.5 Kgs for transmitter as well as receiver, Signal current Measurement in cable. (OEM/Authorised dealer certificate required along with equipment) Make 3M.or Stanlay or approved by railway before supply

1

532695

532695.25

... More
Supply of maintenance OFC tools kit as per TEC specification no. GR/OFT-01/03 APR 2005 or latest , one set consisting of following:1-Digital multi meter 4 1/2 digit with Liquid crystal Display 1 No. of Phillips/Motwane /fluke/stanlay Make.2-Utility Knife - 1 Nos 3-Cable Slitter -1 Nos.4- 51 Tubing cutter for cable armour-1Nos.5-Bare Fiber adaptor.6-Miller Height precision stripper for fiber buffer .7-Cleaver Fujkura make or similar.-1 Nos.8-FC/PC Adopter with DB loss-2 Nos.9-Earth resistance measuring instrument with all accessories suitable for measuring earth resistance in range of 0.1 Ohms to 10 Ohms.10-Megger-100v -1 Nos.500 v-1 Nos.11-Loose tube stripper-1 Nos.12Cord stripping pliers.13-Supply of Krone tool-2 nos.14-duct cutter -2 Nos

2

161044

322089.14

... More
Supply of Optical Power Meter suitable for of testing 1550/1310 As per Spec. with Lithium Battery ,adopter and other accessories .Make /& model OLP-35 Power Meter JDSU or simlar. before supply model make approved by Rly.

2

44076

88152.92

... More
Supply of Optical Source (1550, 1310 ) make and model JDSU/VIAVI OLS -35 JDSU or similar Light Source with Lithium Battery and adopter and other accessories , . before supply model make approved by Rly.

2

157088

314176.24

... More
Supply Fusion splicing Machine with all accessories. Make Stanlay or similar as per tech.specification TEC.GR/TX/OSM-001/04 Sep-2012 with latest amendment. : before supply model / make approved by Rly. Inspection Authority RITES.(OEM/Aouthorised dealer certificate required along with equipment).

-

-

54

... More
Supply Optical time domain Reflecto meter make Stanlay or similar as per 55 tech.specification No. G/OTD-02/02 Jan-2005 with latest amendment all accessaries.as per spec. before supply model approved by Rly Engineer .Inspection Authority -RITES.(OEM /Authorised dealer certificate required along with equipment).

2

378716

757433.36

... More
Supply of power pack 230VAC/1-5 AMP complete with battery backup of 48volt/7ah suitable for way side equipment Make -Axiom or similar .before supply model make approved by Rly.

4

19040

76162.12

... More
SMPS base power supply 12v/10 .amp. Make Paswa/Axiom or similar .before supply model make approved by Rly.

8

1561

12488.72

... More
Supply of Electric rotary Drill machine Drill RH24A (230V) (Make Wolf or Bosch or superior as per spec. Original manufacturer/dealer/distributer certificate to be submitted.

2

5138

10276.1

... More
Supply of Cable fault locator. Model Sidekick plus 1155-5001 or similar make stanley. as per specification -Inspection Authority -RITES .Make model before supply approved by Railway.

2

532366

1064732.34

... More
Mild Steel Heavy duty Storage adjustable fully folding powder coated. Racks for well upkeeping of material in store .No. of Shelves 3 per rack .Load bearing capacity per Layer (shelves )- 100kg to 500Kg, before supply approved by railway.

10

13270

132708.2

... More
Supply of 25 mm dia. HDPE pipe (TEC spec. No.G/CDS-08/02, Nov'04 or latest) with accessories on wall or structure / in trench etc. for drawing of CAT-6/OFC cable/ power cable in the same to suit Allmaterials for jointing, fixing, clamping of HDPE pipe.

800

31

25120

... More
Supply of Microcontroller based Quad Cable Conductor's Earth Resistance Sensing Unit, for 24 nos. conductors with metering facility for one conductor at a time.

12

79679

956159.52

... More
Supply of Multi Telephone Way station Equipment with neccessory mounting arrangement on composite rack or on wall. It shall be 48V operated Specification No. RDSO/SPN/TC/66/07 with amendment -3 or latest. 64

10

76924

769242.6

... More
Supply of push button telephone having DTMF signalling 65

50

800

40037

... More
Supply & PVC rigid pipe 25mm dia conforming to ISI spec. No. ISI/9537.

6000

18

112800

... More
Supply of Standard 19" Rack Mountable -48V DC Working, Add-Drop STM-4 SDH Equipment conforming to TEC GR No: GR/SDH-010/03. JAN 2011 (with latest amendment ) complete with, redundant power supply, 2 Nos STM 4 of Aggregate L.4.2 Optical Interface Modules/ Cards one each for East and West side TX/RX and 2 nos of STM-1 S1.1 or L1.1 optical interface modules complete with 5 mts. long Optical Patch Cords. 63 E1s card with DDFs and Cable assembly for 66 termination to DDF and minimum 8 nos of 10/100 Base-T Ethernet Ports Fast Ethernet on SDH (EoS) 10/100 Base-T Interface Module/ Card supporting with LCAS and GFP, order wire subrack DDF installation Material, manuals and other accessories. Complete Engineering Order Wire (EOW) arrangement. .Note-compatable with existing section and adjoining station. Necessary Software/ Firmware for local/ remote monitoring/ configuration of the equipment through NMS and Software/ Firmware Interface to work all Network Elements as Gateway Network Element (GNE). 2 Nos. of MCBs of appropriate ratings and necessary Connecting cords and cables for power supply modules as per TechniclSpecification in Chapter 4

6

353429

2120579.16

... More
Supply of Primary Digital Multiplexing Equipment (2.048 Mbps) Fully equipped at every station as per RDSO No. IRS:TC:68/2012T Revision 0 Amd-1 or latest. for 30 Channels complete with 67 power supply card One set of operation, programming and maintenance manual. Number of circuits should be approved by engineer incharge before supply. .Inspection authority consignee.Note- compatable with existing section and adjoining station.The above MUX should be equipped with 30 channel circutes with maximum E&M card and Compatible with as well as inter oparable card level of the equipment provided in the adjoining section of BRC Division.Got aprove before supply

6

182175

1093053.24

... More
Supply of Local/Remote service Terminal (Portable) with software for managing both STM1/STM4 ADMs and primary Digital Drop Insert Muxes as per technical specification.

2

132947

265894.64

... More
Supply of 48V , 50 amps battery charger for telecom use as per No RDSO/ SPCN/ TC/ 69 23/ 99 (ver. 4 ) or latest in N+1 configuration i.e. using 3 modules of 25 amps with automatic switching between the modules for two sets of 200 AH battery for charging with SMF VRLA. it shall be equipped with surge and lightening protection of class 'B' and 'C' the configuration shall be decided as per site requirement. 70

6

76451

458709.54

... More
supply of full charged VRLA 200 AH Batteries.as per IRS.93/96 amd.1 or lateast.

6

66473

398839.2

... More
Supply of in-built GNSS based cable route tracer with 10W ,500 mA ,85V transmitter suitable for detcting & mapping underground cable with acuracy which cane up to 3-5 cm or 71 better,with current direction up/down arrows ,Remote calibration check feature,supply shall include inbuilt RTK enabled reciever trnsmitter compatable dual blue touth android device along with minimum 5 year subscription ,compatble with NTRIP and RTCMv3.X massaging standard and holder & standard accessories .Mak/Model: Radio detection RD8200GS or similar. 72

1

1387100

1387100

... More
Supply of UPT. Category- 6 Class E for Networking. AVAYA, Digisol or D-link.

-

40980

40980

... More
Supply of Self Supported aluminium flat step ladder (conforming to ISI) 12ft. Height.Ladder Should be self supported and it should be made up of rust proof Alluminium of Min 16 SWG.No plastic hinges/Step Support Should be used.

6

5678

34073.64

... More
Supply of Central Data Controller Unit conforming to system requirement as per RDSO Spec..RDSO/SPN/TC/108/2019 Rev.1.0 or latest. The control console shall have main and standby CPU to work in standby mode, one Nos. of 1 Kva UPS with two independent batteries, two LCD monitor (19 inch), CCU Rack, KVM Switch, CDS (Layer3 12 Port Switch of make CISCO, HP, Juniper, Brocade, Avaya, Extreme, Netgear, D-link ) and other accessories, housed in a standard size cabinet along with 74 driving Software for integrated passenger information system as per RDSO Specification No. RDSO/SPN/TC/108/2019 REV.1.0 or latest. this includes supply and installation of SW for Announcement system with necessary interface and announcement recording (Hindi/English/Gujarati) fresh studio copy of voice files.) as per RDSO Specification No. RDSO/SPN/TC/108/2019 REV.1.0 or latest (the same to be interfaced with existing audio and video system installed at the station.). the software should support all types of display/announcement by merely adding necessary hardware in future (single/multiline arrival/departure train information display boards. (single sided/double sided), CGDB, AGDB, LCD/LED/Plasma TVs etc.

6

457535

2745211.86

... More
Supply of OFC single mode 6 fiber armoured cable of make finolex/Polycab/Paramount or similar 76

500

26

13180

... More
Supply of microphone with cord and other accessories.Make Ahuja or similar 77

6

2104

12625.26

... More
Supply of microphone standsuitable keep in table

6

226

1358.76

... More
Supply of horn speaker type-15/20 Watt wheather proof with driver unit Make-Ahuja or similar. 79

80

1602

128180

... More
Supply Column speaker.Make Ahuja or similar Model SCM 30T

20

1416

28328.8

... More
Supply of twin core shielded cable of size of each core 24/36 SWG with standard colour (Red & Black) having screening coverage of 95% area of the sheath of the cable using braided copper conductors.

6000

31

189840

... More
Supply of Universal Fare Display System with Power, Data Cable & connector for PRS/UTS/ Thin Client Terminal as per Technical Specification

12

5296

63554.52

... More
Supply of 6 core fiber termination box with Capacity of Ports: 6 ports, Suitable Adapter: SC/LC.

10

198

1989.9

... More
Supply of remote fault diagnosticsystem. Configuration as per technical specification.

4

82707

330830.2

... More
Supply of HDMI to fiber converter and fiber toHDMI converter in pair should have 20km range with one Year warranty. Product should have following minimum Speciation: 1. Full HD 1080P 84 HDMI Optical Converter/Extender 2. Supports up to 1920x1080@ 60Hz 3. Distance - 20KM over Single Mode fiber 4. Video Input Port - HDMI 5. Video Output Port - HDMI 6. HDCP Supported - Yes 7. HDMI Resolution -Up to 1920x1080@ 60Hz 8. Wavelength - 1310nm/1550nm 10.Power - Input: AC110V- 220V,50/60HZ, Output: DC5V/2A.

4

17439

69758.96

... More
Supply of crimping tool suitable for 0.5mm and 0.63 mm dia telecom cable. Make- krone or similar 86

4

1611

6447.96

... More
UPS 1 KVA online having one hours backup.Make -APC/Numeric/Microtek or similar 87

6

33137

198822.96

... More
Supply of HDMI Cable 3Meter compatible withHDMI video source devices.) 88

10

273

2738.1

... More
Supply of 10 Mtr length HDMI cable (supporting2.0 and above). 89

10

1482

14821.2

... More
LC/SC/Euro OFC patch cord 1.5 to 10 mtr log. As per requirement.

500

667

333810

... More
Supply of Single Mode Single fiber Managed Media Converter (Ethernet & E1 to Optical vice versa) Pair and all the accessories required for their installation as per RDSO Spec NoRDSO/SPN/TC/103/2013 Rev.2 or latest.as per technical specification.

10

12753

127530

... More
Cable route survey & Preparation of as built final cable route and other plans (for OFC as well as other telecom cables whose laying is covered in this schedule) taking into account the points mentioned in chapter II & other chapters of technical requirement on Auto CAD for entire sections for entire sections VG-SIOB. The cable route & other plans shall be prepared by contractor 1 after joint survey, got approved from engineer in charge, changes during course of execution shall be incorporated in the same. After completion of the work all completion documents of tracing papers along with six prints of cable route plan, jointing & splicing schedule, cable hut wiring diagram etc. in six sets for each station and section in folders shall be supplied by the contractor. Contractor shall also supply the Auto CAD documents on CD. All the required materials, accessories including tracings, papers etc, shall be contractor's own.

110

1167

128407.4

... More
Supply ,Installation & Transportation of VF Transformer Box Assembly Wall Mounted 2 Type for 6 Quad Cable Arrangement in RE Area along with OFC consisting of neccessary VF Transformers, U Link/ wago terminal, Socket Selector Switches, Wago Terminals etc. Mounted, as per Drawing No.: B/SG/P/Drg/Tele/1/2008 & B/SG/P/Misc/50/2008 and tested all circuits.make- Epsilon/Santel.

6

37508

225053.4

... More
Excavation of trench 300mm wide at the bottom and 1.2 mtr deep, in all type of soils including clearing of trees, bushes, etc. and refilling of cable trench by excavated soil and ramming after laying of HDPE DUCT (laying of HDPE/DWC & 6 Quad. cables, PDF cables etc., will be paid under 3 different items of the schedule). Where desired dimensions of trenches could not be achieved proportionate payment will be made as decided by Engineer-in-charge of the Railway at site. The trenching outside the station limits I.e.) between the home signal of station 'A' to home signal of station 'B' may be done manually or by machine, as per the directions of site in charge. In no case the payment will be made for the trench of higher dimensions, than the dimensions as mentioned above.

17000

288

4904500

... More
Preparation of cable way 150mm wide at bottom and 200mm deep in rocky area/CC road/Platform and other CC/Stony location and refilling the same (after telecom Cable laying as well 4 as laying PVC pipe which shall be paid separately under different items of the schedule ) with concrete mixture of proportion 1:3:6 all along the trench done rocky area with contractor's own cement mixture, sand, water and other required materials and restoration of earth work as original with tiles/marvel/Granite etc.

3000

214

642750

... More
Manual horizontal auger boring/drilling of 100mm dia Horizontal Bore across the Railway Track/ Across Road at LC gates by Boring method at a depth of 1.65mm from the ground level/ ground level to be considered ignoring the bank height of the bank/road and insertion of HDPE/DWC/GI pipes etc., as per the instructions of Engineer in charge at site as per drg no. RAILTEL/SR/OFC/2008/10.

-

-

5

... More
Horizontal direction drilling/boring without damage of surface road using Auger 6 Machine. The bore shall be 150 mm dia & shall be done at the depth of minimum 1500 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the roadas per direction of Engineer In charge.

55000

1075

59153600

... More
Excavation of cable trench in rocky area, 450 mm wide at the top, 300 mm at the bottom and minimum 0.5 meter deep in rocky area ( rocky soil mixed with boulders/hard murrum) including cleaning of trees, bushes. The trenching will be done manually only and limited to the 7 stretch between the home signal to home signal of each station and other locations as per the directives of the site in charge. Where desired dimensions of trenches could not be not achieved proportionate payment will be made as decided by Engineer-in-charge of the Railway at site. In no case the payment will be made for trench of higher dimensions than the dimensions as mentioned above.

600

415

249318

... More
Laying of OFC/Quad Cable, PIJF cable of different size in the excavated trench. This includes loading/unloading & transportation of cables from the stores of SSE/T/C/PRTN to the site/ 8 Wherever several cables of provision of separation of various cables should be as advised by the site incharge of the Railway. Empty cable drums to be retained by the contractor the cable drums with unused cable at site to be returned by the contractor from site to be returned by the contractor from site to Stores of SSE/T/PRTN.

65

6394

415650.3

... More
Fixing & laying of 100 mm /80 mm dia GI pipes or GI trouphing (supply of GI pipe is 9 covered separately in Schedule 'C1') and parapet wall/roof of culverts, including masonry work at both ends with contractors own material and bending of the pipe at the both ends etc. as per Drawing No. SK/CSTE/C/97/05 & directive of Engineer in-charge, Perforation should be done before laying of GI pipes.

800

165

132240

... More
Execution of quad cable jointing using thermo shrinkable joint kit straight though/ 10 Derivation / 2T / 3T transformer joints with VF transformer between 6 quad & PIJF cable this i/c transformers on 6 quad / jelly field cable this i/c VF transformation of jointing kit transformer covered in Schedule 'A'. 11

70

1283

89870.9

... More
Execution of straight through joint on quad cable/5-10-20 pairs PIJF Cable.

150

1121

168151.5

... More
Fabrication of EC socket box, assembly and erection of fabricated assembly at the location indicated in the route chart and as per direction of Engineer in charge. This includes cutting of rails / GI pipe to required size, supply and welding of GI Pipe and base plate, fixing of EC Socket box, transportation of material to site, digging of pit and erection of whole assembly at site. The work 12 also includes the termination of 6 Quad/PIJF derivation cable on the strips of 6 pin EC socket inside emergency socket box. The fabrication of EC Socket box shall be done as per Drg. No. SK/CSTE/C/97/16 & SK/CSTE/C/97/20. Rail/GI Pipe post will be supplied free of cost at the SSE (Tele) C/PRTN depot in full lengths. Note - In addition to above, the centre pins of EC sockets shall be terminated with a dedicated pair of 6 Quad cable (Derivate through the tail PIJF cable) in the entire block section so as to provide magneto/auto telephone communication from each EC socket.(All materials supply by contractor except rails & GI Pipe for post.).

60

3574

214485.6

... More
Fixing of 20/12 pairs CT box & termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.(for station)

50

367

18355.5

... More
Supply & installation of RCC cable route marker engraved on both side and painted on both sides along the route every 50 to 100 mt. & route diversions as per Drg 4014/00/CC4.

2400

436

1047288

... More
Painting of emergency socket assembly and rail post by applying one coat of red oxide as base color, and then painting the assembly as per zebra painting in white and black colors. The width of each of the black and white colors shall be 100mm. All paints used shall be with ISI mark.

60

708

42517.2

... More
Supply of paint & painting of telephone / Cable mark lenght from center on every hectometer/OHE mast with indicating arrow, indicating the direction of the nearest emergency socket on the RCC route/joint markers & EC socket box with kmtrs. All paints used shall be of Asian/Shalimar/Acolyte make with ISI mark. The indicating Arrow and all other writing work shall be done using black enameled paint with background painted Yellow. The work shall be carried out as per directive of site engineer.As per drgRAILTEL/WR/OT/DFC/012.

2500

102

256975

... More
Placing of RCC/DWC/ Split DWC pipe in trench and track/road crossing protruding equally outside the rail/road edge on either side.

-

-

17

... More
Provision of maintenance free earth Earth Electrode. spec of RDSO/SPN/197/2008 or 18 latest complete with material in ring fashion ( minimum three electrode in ring ) at cable hut / ofc room or where required .minimum 3 electrod provided in ring as per engineer in charge .approved drg. Mantenance free electrode used .RDSO/RITES inspected .and certificated provide to consignee before installation.

12

34296

411553.8

... More
Installation of Maintenance free Earth Electrode for Maintenance free earth as supply in sch.A.

40

2716

108640.8

... More
Supply & Fixing of GI trouphing on girder/ other type bridges in yard and mid sections 20 for carrying telecom cable. This includes supply and fixing of 100mmx50mmx06mm and1. 2 mtr long MS channel .Before installation material inspected by Railway repersentative as site engineer instruction.

-

-

824902

... More
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

40

3403

136151.6

... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 22 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.

10

1923

19232.5

... More
Supply & Installation of Professional 19" mount Equipment Racks 9U for housing telecom Equipments.Rittal/santel/ Vero President

20

10363

207277.2

... More
Installation of fiber distribution management system (Supply covered Above) with all installation materials, restoration wall etc. to original condition , splicing and termination of 48 fiber cable (With all contractor's materials), routing/dressing fibers as per directions of Engineer in-charge.

10

3718

37188.3

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 25 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the end of duct should be sealed with end plugs before laying and should remain sealed till blowing is done.Note- laying Duct as per HQ polcy dated 01.01.2025

240

6582

1579850.4

... More
End to end testing of all fiber of the optical fibred cable laid under above items 26 between station/cable huts. All required equipments, tools and plants shall be arranged by the contractor. Five nos. of print out of traces in folders of OFC parameters/ results, The per kilometer link loss shall be as per the policy/technical circulars issued by the railways from time to time.

24

14349

344378.64

... More
Splicing of laid under above items OFC cable and making the splice joint in dust free environment with contractor's own equipments and labour. Straight joint enclosure (SJC) is covered under schedule 'A' remaining all required materials, tools , plants shall be arranged by the contractor. 27 splicing shall be started from one end and each splicing shall be monitored after splicing and after closing the enclosure for all the fibers from one central location by contractor's engineer with his own OTDR and optic Talk set with railway engineer , trace for the fibers shall be taken and signed jointly, if any fibred splice shows high loss/lossy event, the same shall be redone before completion of splicing work. The splice loss shall be as per the policy/technical circulars issued by the railways from time to time.

20

8041

160831.8

... More
Blowing of OFC through HDPE duct & protective work (elicited in above item) already provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn /laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. In case OFC is to be laid adopting 'Direct in trench' method then this item shall be paid as per accepted rate of item no.(6 h) of this schedule. OFC and HDPE pipe shall be supplied by the railway.

-

-

28

... More
Supply & installation of RCC pre-fabricated OFC jointing pits size 0.6mx1.12mx1m.round type as per RCIL drg No. RAILTEL/WR/OT/DFC/011 The material shall be supplied as per engineer in charge instructions.

120

4937

592509.6

... More
Fixing /Claimping of PVC pipe/HDPE pipe/HDPE duct 40/33 mm /Gi Pipe on wall etc .Claimp provide by contractor.

2000

35

70420

... More
Installtion of 42 U rack and supply necessary ladder for cable way up to 10 Mtr. ladder (cable way) siz 200 mm Wide 4mm thick .all material for ladder given by contractor .

12

9683

116199.96

... More
Hiring of vehicle SUV/MUV for staff for field supervision location to location at work site and emeregency material transportation in case any emergency like cable cut or minor work .other than contractor material transportation from Store . for 2500 km per month.

24

42700

1024804.32

... More
"Hiring of JCB for Excavation work otherthan trenching.like Removal of piles of soil, sloping soil, boulders, debris, rails, sleepers coming in the cable route etc.as per railway site engineer incharge. "

400

915

366392

... More
Skilled man power to be provided by contractor for Engg. JCBs working to provide marking & supervisory work for the S&T cables during digging work by JCB's and repairing 34 /restoring/jointing of cables, if damaged Cables & Joints Material will be provided by railway. for miscleneous activity, inspection complaince & bridge pending work etc by engineering. where work completed by S&T.but not commissiond or commissioned but not handeded over.and helping with railway staff.

1200

754

905100

... More
Laying of power cable, telecommunication cable at OFC room ,panel room and station with termination etc as per instruction of railway site engineer.

2500

102

255450

... More
Supply, Installation, testing and commissioning of 2x48 Fiber (SC/APCSC/ APC) FDMS 36 including splicing of OFC and termination of all fibres using pig tail cable of standard size ( All materials including pig tails (5 meter each) to be supplied by the contractor, this also includes arrangement & fixing of suitable metal box fixable in wall for spare OFC coil) Insp. By Consignee.

30

31295

938856.9

... More
Supply and installation of straight joint enclosures (SJC) complete with all accessories with latest amendments or Raychems RPG make FOSC-400-B4-A-BJL-4-H -48 or similar make only.(For 48 fiber OFC) and splicing of 2X48 F laid OFC.

150

18611

2791743

... More
Supply and installation of OFC Interface Equipment for Master Telephone (Gate Telephone System) with all necessary electrical points and wiring as per TS.

4

37308

149235.32

... More
Supply and installation of OFC Interface Equipment for Slave Telephone (Gate Telephone System) with all necessary electrical points as per TS.

10

34048

340488.4

... More
Supply and installation of OFC based Master Telephone unit for gate communication with voice recording facility complying to latest RDSO Spec.No. RDSO/SPN/ TC/51/2021 Rev. 1 or latest with all necessary electrical points and wiring as per TS.

8

51435

411483.76

... More
Supply and installation of Master Telephone Voice Recording Facility (Suitable for 16 slave phone) for S No. 5 and as per TS.

4

39844

159377.52

... More
Supply and installation of Slave Telephone suitable for OFC based gate communication following RDSO Spec.No. RDSO/SPN/TC/51/2021 Rev. 1 or latest with all necessary electrical points and wiring as per TS.

30

5433

162999.6

... More
Supply and installation of 12V Power Supply Unit with battery and charger for gate communication system for slave telephone as per TS.

-

-

43

... More
Supply and installation of 12V Power Supply Unit with battery and charger for gate communication system for master telephone as per TS.

10

8693

86933.2

... More
Preparation of cable route of buried S&T Cable using Radio Detector 8200GS or similar model GPS Model and DGPS for Trench per km.for existing cable as per the instruction of Engineer in- incharge.Sumission of report in KMZ file formate,soft copy only.

-

-

4344088

... More
Installation, wiring, testing , commissioning of Drop / Insert Mux with E1 interface cards connection to 48V bus bar & termination of VF/Data interface circuit to the crone MDF in already installed 42U Rack. This include4s termination of PVC cable at both ends, taking PVC Cable over 46 runway or on the wall. This also includes supply of PVC cable of conductor size 0.63 mm. (ii) Testing and commissioning of STM-4/ D / I Mux Equipment installed vide item no. 1 & 2 above using NMS as per as per approved test protocol. The work includes submission of all technical documents, manuals. All miscellaneous items required for the final testing and commissioning for the system will be supplied by the contractor.

6

19640

117841.44

... More
Installation and wiring of SDH STM-4/ADMs primary drop insert multiplexers with all accessories, 19" rack with suitable stand/ platform made of MS angle/CC , power supply board FDF racks

6

24607

147646.14

... More
Supply & installation of Class-B & Class-C Type surge arrestors for single pase supply and as per standard practice & including supply of all the materials required for the work.

6

22063

132383.46

... More
Installation, wiring, testing and commissioning of SMPS battery charger & maintenance free VRLA cells at each station. Note:- The rate quoted shall be including the cost of DC bus bar of 48V 49 DC /Power wire suitable stand etc.connection of power supply to the equipments. All the wiring shall be done with the suitable gauge of power wires through suitable casing / capping as per the instructions of railway engineer's. All the materials required for this item shall be supplied by the contractor.(SPMS charger is covered in schedule - A & VRLA battery will be supplied by Railway)

6

2892

17356.92

... More
Installation, wiring testing and commissioning of way side equipment and telephone on the rack as per consignee in-charge. NS51 6000.00 Running

12

2538

30459.24

... More
Laying of UTP CAT-6/PVC/PA cable throgh pipe/casing capping etc.

-

74880

74880

... More
Supply, installation, testing and commissioning of GPS based double faced platform Clock as per RDSO Specification No.RDSO/SPN/TC@47>47@2008 Rev.3 Amd.1 & 2.0 or latest

10

44730

447303.4

... More
Installation, testing and commissioning of CDC set as per RDSO Spec.RDSO Specification No. DSO/SPN/TC/108/2019 Rev.1.0 or latest or latest as supplied above.

6

14529

87178.08

... More
Installation & Commissioning of double face coach guidance display boards/Speaker as supplied under schedule A, in open area. It includes Supply, hanging & Fixing arrangement of coach indication board/speaker along with hood (Cover shed) in open space, (without shed area) 100 mm 54 dia (OD) & 15 feet's long G.I. to be erected with concrete foundation (1:3:6) of 3 Feet deep from platform level and on the pipe, an angle to be fixed on G.I. pipe as per site condition. Contractor to supply all required materials with G.I. pipe & G.I. sheet of 2'x3' which should be placed on the top of the board in open space as per approval of site engineer with angle fastening and crow guard.(supply of G.I. pipe included in this) 55

80

6610

528808.8

... More
Supply, installation & testing of two zone 200 -250 watt Amplifier.

12

29682

356191.08

... More
Installation Testing and commissioning of different type of speakers to be supplied under Schedule 'A' with hanging arrangements and clamps on cover shed/poles as per directions of Field Engineer.

20

461

9223.6

... More
Installation of Universal Fare Display System for UTS Ticket windows compatible with all PRS & UTS thin client/ Dumb Terminal including all necessary material.

12

383

4602.48

... More
Splicing of fibres of OFC Cable and making Splice joint of fiber with contractor's own splicing machine and tools and consumables.(Payment per fiber which splice not count total fiber of cable)

500

337

168795

... More
Supply and Installation of 65" Professional Large Format Display, 24 x7 for passenger amenities and train information display, as per technical specification

4

182413

729654

... More
Supply and installation of Industrial grade 24X7 TV of 43 " LG samsung or sony as per technical spec.

6

84213

505283.4

... More
Supply and installation power supply distribution box along with MCB/Fuseas perspecification and requirment given by site engineer .make 3M,SANTEL,ABB or similar.

6

22243

133462.08

... More
Supply,Installation and commission of Desktop Client PC along with 600VA UPS as per spec. 63

6

70151

420908.34

... More
Supply & installation of CAT-6 Surface mount info-outlet as perspecification. 64

20

294

5896.2

... More
Installation, testing andcommissioning of Online UPS 1 KVA.

6

402

2417.1

... More
Supply & Installation of face to face enquiry consisting of an attendant unit, a customer unit and a power supply unit, which are easy to install and through dedicated cables as supplied with the system.

6

9180

55081.62

... More
Installation and commissioning of mapple 4C and interigated acecess device necessary 66 assare necessary accessories (power MCB,OFC patch cord krone and wiring material etc )also provided for installation item above supply.including necessary training of staff.As per engineer inchage.

10

15203

152037.4

... More
Installation of Microcontroller based Quad Cable Conductor's Earth Resistance Sensing Unit, for 24 nos. conductors with metering facility for one conductor at a time.

10

8348

83480.9



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.