Western Railway Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Western Railway - WR Tender

Goods
Machinery and Tools
Ireps
Opening Date4 Jan 2024
Closing Date5 Feb 2024
Tender Amount₹ 1,03,06,853.89 
Notes
Download

Costs

Summary

Rajkot Division: S&t Work In Connection With Providing Rub With Cover Shed And U-wall / approach Road At Lc No.235 At Km 882/6-7 & At Lc No. 236 At Km 884/1-2 Bet Kmbl- bhtl.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE 4 area THREE Aspects complete (without lanse, lamp, holder, transformer) suitable for LED signal as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. NoRDSO/SPN/194/2006 (Vol.1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Supply of LED Unit is not covered in this item).

3

31801

95405.52

... More
Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE 5 area TWO Aspects complete (without lanse, lamp, holder, transformer) suitable for LED signal as per RDSO DRG. No. SA 23No. RDSO/SPN/194/2006 (Vol. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. (Supply of LED Unit is not covered in this item)

2

30356

60712.22

... More
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The manufacturers, suppliers must 7 produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring . 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Running

20

1867

37357

... More
ARA Terminal blocks with links made of PBT Spec No.IRS/75/2006(Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.

400

77

30808

... More
"Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments.Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3)"

200

61

12358

... More
Supply of End plate for above item (I) 2.5mm/0.091 in thick as per site requirement.

20

11

230

... More
Supply of End Stopper for above item (I) 10mm/0.0394 in width as per site requirement.

20

11

230

... More
Supply of Carrier Rails for above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement.

4

120

483.52

... More
Markers strip for above item (i)

2

17

35.26

... More
Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied.

6

5251

31511.76

... More
Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC- 77/2012 revision 3 With latest Amd.

6

2516

15097.74

... More
Cartridge fuse block made of PBT as per RDSO Drg No SA-23748 Alt 4 & Spec No IRS S 75/2006 with latest amendment. Fuse block shall be suitable for round head type voltage fuses. This also includes supply of equivalent no of ND type Fuses of 20A capacity as per specification IRS S-78/92.

200

145

29130

... More
Round head type non detoriating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 6A/10A capacity.

200

63

12642

... More
Indicative type Fuse base/ holder with cap, suitable to G type fuse of capacity 0.63A - 3.0A. (System, Rapid, Malnad or RBCO make or similar).

100

57

5717

... More
Indicative type Fuse suitable to G type fuse base/holder of capacity 0.63 A - 3.0 A (System, Rapid, Malnad or RBCO make or similar).

100

20

2087

... More
ND FUSE Cylindrical Type 16Amp IRS:S. 78/92 (Fuse for replacement as 3 years)

400

54

21712

... More
Cable termination racks as per Drg. no. CSTE 5004, 5005, 5006 complete along with fitting 23 arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals not covered under this item. Cable termination rack shall be Powder Coated.

1

25617

25617.82

... More
Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, 24 insulators, grouting bolts, tripods etc. as per Drg. No. CSTE /6028 .[Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion]. Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items as Annexure.)"

1

27887

27887.12

... More
Single core multi-strand wire 0.5 sq.mm. (16 conductor each dia. 0.2mm), as per IRS 76/89 (Amd3).

3

5916

17749.26

... More
"Ferro resonant type automatic AC voltage regulator 3 KVA capacity input 160-270V, output 230V as per RDSO Specn IRS S:74/89 with amendment-6 or latest. Accepted Make - ESTAR. "

2

41554

83109.76

... More
Rubber Mat for Power Equipment room. ( 5mm thick-RE fit)

60

114

6855.6

... More
Universal AC ECR of Q series, type "QECX61" suitable for AC LED all signal aspect, Front & back contact Metal to Carbon type complete with plug board retaining clip & connectors conforming to Spec STS/E/Relays/AC Lit LED Signal/09/ 2002, BRS: 941A, IRS:S34 and IRS:S23 (as applicable)

6

5638

33830.28

... More
Relay, AC Immune, Plug-in-type, style "QNA1K" ACI DC Netural line, 24V DC 1000 Ohms 6F.6B 29 contacts, front contacts metal to carbon and back contacts metal to cabon. complete with plugboard, retaining clip and connectors confirming to IRS:S34, IRS:S23, BRS931A. As per RDSO Specification No. STS/E/Relays/UEA(PI) Dt.30/05/97. Annexure II. The interlocking pin code CDEKY.

8

5618

44946.32

... More
Fail safe electronic time delay device mounted on Q series relay base & covered with fixed timing of 60/120/180/240 seconds as specified by purchaser conforming to IRS.S. 61-2000 or latest.

2

7050

14100.78

... More
Key Lock Relay working on 24V DC, AC Immunized with different ward combinations (Three ward plates to be supplied with each relay).

3

8544

25633.32

... More
Fale safe electronic flasher device 24 DC/110V AC as per RDSO Spec No. RDSO/SPN/173/2002 (Amd.2) or latest.

2

8933

17866.88

... More
Dual tone bell/buzzer with 25W horn, working on 24 V DC for road user.

3

9292

27876.27

... More
Road warning flasher kit for L.C. gate as per circuit design.

2

1957

3915.44

... More
Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (20KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/ 2008.

4

8850

35401.88

... More
Flexible cable (Power wire), multi-strand copper conductors cross section 1x6 Sq.mm.( 85 conductor each diameter 0.30 +/- 0.01) as per IS 694/1990 with insulation thickness of 0.80 mm nominal conductor resistance 3.30 ohms/km and test parameters are as per IRS(S)76/89.

0.2

-

8752.41

... More
Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 + 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/ Km and test parameters as per IRS(S) 76/89.

0.2

-

28070.89

... More
Provision of T-Networking suitable for Networking to the existing Data Logger equipments. This includes supply of all equipment / accessories required for the purpose.

1

34791

34791.99

... More
Fire Extinguisher CO2 type (capacity 5 kg or more.)

4

7382

29530.16

... More
Earth Electrode as per Drg. No. CSTE / 6091.

16

3771

60350.08

... More
Supply of ladder (Inspection authority : Consignee)

2

21150

42300

... More
Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes.

20

290

5808.2

... More
Battery Charger for Railway S&T installation self regulating floor mounting type with 230V AC single phase input and output 24 V DC, as per spec. IRS.S.86/2000 with latestamendments.50 Amp

4

41822

167290.76

... More
Transformer 230V/110-130V Single phase 1 KVA as per Spec. IRS S-72/88 with latest amendments.(For Signal Lighting)

4

7009

28036.8

... More
Precision Pipe and Cable locator / Route tracer as per technical specification. Make Radiodetection or similar or superior.

2

465000

930000

... More
Digital Multimeter of Fluke 287 lndustrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 second or Superior.

2

22414

44828.2

... More
Supply of digital Earth tester 4 Terminal for measurement of Earth resistance as per technical specifications .

2

5243

10487.84

... More
Megger 100V to 500V X 20 mega ohms as per specification make: Fluke model No 1507,Motawani.

2

39332

78665.88

... More
Mini AC/DC Low Current Clamp Meter as per Specn. High Sensitivity, Miniature type Clamp, Resolution of 0.1 mA for AC,1 mA for DC Current, Measurement range 0-20 A MakeKEW, Fluke.

2

39819

79638

... More
SS AC Box HALF(Fabricated of 2.5mm SS Sheet, Fixed Type)

6

63420

380520

... More
SS AC Box FULL(Fabricated of 2.5mm SS Sheet, Fixed Type)

4

73004

292016

... More
MS Sliding type mechanical Boom barrier assembly 11 to 12 Meter Long, movement drive mechanism, resetting & supporting stand suitable for Mechanical/Electrical level crossing gate as an emergency arrangements as per Drg.

2

132154

264308.5

... More
Installation, testing and commissioning of electrically operated lifting barrier, complete with Casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc.

1

52531

52531.41

... More
Installation and complete wiring of of operating cum indication panel for LC gate as per technical 2 specification and site requirement. The indoor wiring inside panel shall be terminated on tag block as per instructions of Engineer-in-charge. The wiring on panel tag blocks shall be repeated on tag blocks located in relay room. This includes laying & termination of cable, if any from Panel Room to Relay Room in HDPE pipe.

1

7937

7937.57

... More
Complete Indoor wiring testing & commissioning of station / LC Gate. This includes: (i) Prewiring & fixing of all base plates as per approved wiring diagram. (Supply of relay base covered in schedule 'A'. Excess quantity of base plate, if required will be supplied by Railways, prewiring of which will be done by the contactor.) (ii) Fixing of Relay groups on relay racks. (iii) Soldering of tag block terminals, dressing of wires as per approved rack arrangements/ Circuit diagrams. iv) Wiring on bus bar, fuse base condenser , resistance etc. as per wiring diagram (v) Wiring on Relay rack to relay rack via IDF, IDF to CT rack in relay room. vi) Wiring on panel tag block shall be repeated on tag blocks located on IDF & CT rack in relay room. vii) Wiring between control panel room & 3 relay room. (viii) Supply of simulation panel, which shall be separate for each station and shall be left after commissioning. (ix) Provision 200 way tag blocks for data logger and providing jumpers between voltage free terminals on relay racks and data loggers, tag block with 0.6 sq mm cable. (x) Wiring between Integrated power supply and data logger tag block with one square mm /0.6 sq mm cable as per instruction of Engineer in-charge. (xi) Wiring of key lock arrangement at SM's office/ site & Earth leakage detectors. (xii) Wiring of block instruments from CT rack to block instrument terminals and includes supply & laying of indoor cables for this purpose as per standard arrangements xiii) All wiring & wiring materials necessary to complete Station/ LC gate (Within station limit) Installation but not covered in the schedule anywhere (xiv) Writing of description on all relays & other indoor equipments Note: All wiring will be done as per standard practice of Railways with neat dressing & threading. Detailed testing will include functional testing, selection table, locking table and cross sheet testing with the help of operating panel and simulation panel in the presence of railway officials to their satisfaction. a copy of tested selection table, locking table and cross sheet duly signed by contactor to be submitted to field office for record. This includes supply of lamps for simulation panel for testing. Contactor will Put sufficient Staff to carry out the testing round the clock, if desired by Railway Engineer and will ensure that any alteration which become necessary during testing are carried out & testing is repeated wherever required . (ii)LC Gates

1

24343

24343.92

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required 4 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974). :- Complete painting ,writting and varnishing work at a LC gate. Painting and lettering of power operated lifting barrier(All items of one LC gate to be taken as one Lot)

1

3639

3639.1

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required 5 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974):- Main Signal Post with Signal Units, Surface base and complete fittings as per Western Railways standard practice.

5

398

1992

... More
Excavation and Casting of foundation for main signal post as per CSTE/3122 (WR) with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost.

5

8284

41424.4

... More
Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates / boards if any with contractor's own brackets and fixing 7 materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. The Item includes cutting of Signal post if required by Site In charge. (ii)2/3/4 aspect signal unit mounted mounted directly on signal post

5

2458

12292.9

... More
Fabrication and fixing of Signal Number Plate( CSTE Drg No CSTE/6186) , 'A' Marker (Drg No. 8 CSTE/6180), 'AG' Marker (Drg No. CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor.

5

1375

6875.35

... More
Supply & Fixing of Stop Board, Block section limit Board, goods warning board with contractors own material. The work shall be done as per instruction of Rly. Engineer at site. Running

2

6512

13024.28

... More
Excavation of cable trench as per cable route plan,1Mtr. deep and of 0.3 Mtr. to 0.6 Mtrs wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench 11 by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.

750

308

231255

... More
Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.

25

567

14198.75

... More
Providing chase in hard rocky soil for laying of S&T cables where optimum depth (0.5m) in not possible and which is verified and agreed by engineer incharge.

60

641

38483.4

... More
Digging of cable pit (min 2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter.

2

14683

29367.4

... More
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6 . Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor). Running

7

4077

28545.02

... More
Supply and placing of Half Round RCC pipes & collars of 150 mm internal dia, 2 meter long (or two pieces of 1 meter long) along with collars as per IS No. 458/2003 of NP type Running

1100

442

486519

... More
Supply and installation of RCC Cable route marker as per Drg.No.4014/00/CC4 or latest/stone marker Per

20

461

9236.2

... More
Fabrication and fixing of phenolic laminated sheet of size 10mm thick in location box by providing 21 all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. Half Case

6

768

4612.38

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Fermaetc for Casting of foundation will have to be brought by the contractor at his own cost. Half Case as per Drg No SK 747or CSTE/5074 or SS Location

6

5910

35464.8

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. (Half Case)

6

711

4267.2

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. - MO INF- SRAPL/ODK/J/0132 Date July 30 ,2021 Half Loc.

6

97

582.54

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials including cement and anchor bolts of standard size. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No SK 748 or CSTE/5074 .

4

6848

27395.16

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Single Case

4

1032

4130.88

... More
Fabrication and fixing of phenolic laminated sheet of size 10mm thick in location box by providing 27 all fixtures as per Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1/2. with latest alterations & as per instructions of Rly engineer at site. Single Case

4

2330

9321.52

... More
Painting of two coats of synthetic enamel paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor's own supply of paints. Wherever required 28 contractor shall apply coating of epoxy paint also as per instructions of site-in-charge. Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from Asian Paints/ Nerolac / Dulux / Berger. The primer / enamel paints (Aluminum synthetic, black enamel, brilliant white and yellow) will be as per (IS 5660 of 1970) / (IS 2932 of 1974). Apparatus Case Full Size. (Outside & inside)

4

252

1009.88

... More
Lettering / Numbering Termination particulars, equipments names etc., legibly and neatly inside location boxes. This includes supply of paints of Asian Paints/ Nerolac / Dulux / Berger make. - App case Full size

4

159

638.4

... More
Installation of Cable Termination Racks Assembly complete including wall supports, scaffolding, 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on WR & the instruction of Rly engineer at site.

4

9763

39054.24

... More
Supplying & fixing of crank handle box 450 x 250 x 150 mm made of 12mm thick teakwood with a 31 glass front and padlocking and sealing arrangements as per std practice. Pad lock to be supplied by the contractor. All material i.e. teakwood, handle, hinges, glass sheet of 3 mm thick to be supplied by the contractor. Box to be polished and description to be as per instructions of Engineer in - charge.

1

1578

1578.37

... More
Installation of Dual tone bell/buzzer for LC gate user. To be installed on CLS post erected on either side of gate as per instruction of Engineer in charge.

2

426

852

... More
Installation of Maintenance free Earth Electrode for Maintenance free earth spec of RDSO/SPN/197/2008

4

1367

5468.6

... More
Installation wiring testing and commissioning of Fuse change over system (FACS). This includes 34 provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible.(Per unit means Per module)

2

995

1990.32

... More
Casting of CC foundations in the ratio of 1:3:6 for sliding boom as per Drg. Minimum 10 Nos of 35 foundation per set shall be cast using standard size holding down bolts & nuts for erection. Item include excavation, ramming, curing and plastering 1:4 cement and sand mixture. Aggregate, cement, sand and holding down bolts & nuts to be supplied by the contactor.

1

33029

33029.82

... More
Earthwork in filling in embankment, guide bunds, around buried type abutments, bridge gaps, trolley refuges, rain bunds if provided, platforms etc. with earth excavated from outside railway boundary entirely arranged by the contractor at his own cost as per RDSO's latest guidelines and specifications and special 36 condition of contract including all leads, royalty, lifts, ascents, descents, crossing of nallahs or any other obstructions. The rates shall include all dressing of bank to final profile, demarcation and setting out of profile, site clearance, removing of shrubs, roots of vegetations growth, heavy grass, benching of existing slope of old bank, all handling/re-handling. Taxes, Octroi and royalty etc. As a complete job. Cut trees shall be property of railways and to be deposited in the railway godown unless specified otherwise in the Special conditions of contract

10

163

1631.5

... More
Installation & commissioning of Sliding booms with E type lock and KLCR. This includes wiring of KLCR, running of cables, necessary painting & transportation of materials from store to site. All material required to commissioning of slide booms on gate will be supplied by the contactor

1

17205

17205.57

... More
Installations, wiring, testing and commissioning of Remote Terminal Unit complete along with 38 accessories using Contractor's own wiring & fixing materials. (It includes loading of NETWORKING software and networking with data logger. The requisite communication cable/channel for networking will be arranged by Railway.

1

7438

7438.64

... More
Supply and fixing of KLCR boxes 450x250X150 mm in {ield / in localion boxes / in sM office / at LC 39 gate as per site condition' lt should be made ol Hytum/wooden.(teak wood) ot high quality as per requirement. ltem includes supply ot any minor bracket, nuts, bolts and hole drilling, MS angle, MS plate etc. lts also includes fixing of KLCR relays in the boxes

3

1503

4511.13

... More
Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the 40 material required for the work are to be arrange by contractor himself at his own cost except Thermo shrinkable Joint Kit . After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost.

4

1343

5373.08

... More
Installation of earth electrode as per std. practice and connecting it to equipments to be earthed. This item includes digging of pit in earth 3 m deep & fixing earth electrode pipe, casting of cement concrete 41 enclosure & cover as per Drg No. S&T/Tender/27.Soil treatment to be done as per std. practice. This item includes provision of MS flat/earth lead wires as per instruction and soldering of lead wires. The other end of the wire is to be connected to block equipment, power equipment, cable sheath, signals etc. as per site requirements. 7strand GI wire shall be used as earth lead wire. (Supply of earth electrode is covered in Sch. 'A').

16

1775

28403.2

... More
Supply & installation of Fencing work arround S&T appartus case or building/office etc.

1000

218

218500

... More
Dismantling/Releasing of the existing Indoor Signalling items at station & LC gate connected with station such as dismantling of relay racks, removal of relays, batteries & power equipments, cable termination racks, SM's slide etc.This includes transportation of released material from station to store for DS-8.

3

18690

56071.5

... More
Dismantling Existing Electic lifting barrier / mechanical lifting barriers, Sliding Booms & other material at LC gates complete and transporting them to Consignee's Stores Depot / nearest DS8 yard. This 44 includes complete mechanical items including levers, rodding iron, point fittings, lock bar, compensators, Electrical fittings in the cabin and other miscellaneous items (whatever applicable to the particular installation). Removal of Trestle from the soft soiland bottom, top roller and strand of rod etc. The field items such as Junction boxes, AC boxes etc. shall also be dismantled as per instruction of Engineer - in - charge.

3

6454

19362.9

... More
Dismantling of all signals complete with signal unit, route indicator, signal foundation and other 45 accessories complete with transporting them to consignee's depot or DS-8 depot as per the instruction of Engineer In-charge by contactors own vehicle & labour.(Rate to be consider when total gear to be dismantled at a station is less than 10)

3

4974

14923.38

... More
Installation, wiring and commissioning of all type power supply equipments like charger, transformer, auto changeover and inverter etc. at LC gate.

2

32681

65363.38

... More
Dismantling of Concrete foundations/Dimolishing RCC/CC/Stone Work/Cutting Tarcarpenting/CC Flooring/Pricast Concrete slabs etc./Brick work includingleading the debris inside Railway limit or outside Railway 47 limit as directed by site in charge.

8

841

6730.16

... More
Alteration to the existing Electronics Interloking system in connection with closing of LC No. 235, Modification to the existing TOC and Circuits. Testing of logic, modification to the VDU and MT,Commissioning WITH completion documents.

1

3657438

3657438.69

... More
Desk type Electronic Magneto Telephone as per spec No IRS/TC-79/2000 or with latest amendments

4

3721

14886.24

... More
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. (The manufacturers, suppliers must 2 produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement. 1)Suitable snap fit coupler with rubber 'ORing2)Spacers3)Tees4)Bend,5)End-cap(The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified

20

1880

37603.6

... More
Supply of Half round RCC pipe with 150mm mm inner dia as per Specification (appx. 2 mtr. Long As per (I.S. 458/2003)

60

266

15988.8

... More
Supply of Thermo shrinkable joint kit as per RDSO spec no. IRS TC 77/2010 Rev-2 or latest suitable for 2T joint RTSF3 suitable to 6-quad cable of spec no. IRS TC-30/2005, Ver-1, Amd-4 or latest. With VF tapping transformer (RDSO spec.IRS:TC:76/2000 with amendment 1.

16

2647

42367.36

... More
Supply of 2T Transformer 470:1120ohms asper RDSO Spec No. IRS:TC-76/2021 or latest

4

1279

5117.76

... More
Supply of 2x24 fiber optic fiber splice straight joint enclosure (SJC) complete with all accessories as per TEC Spec no. GR/OJC/02/02.MARCH 99 TEC specs for 24 fiber OFC cable with latest amendment.

8

5083

40671.28

... More
Supply of Plasto crate pre-fabricated OFC jointing pits size 0.6mx0.8mx1m.The material shall be supplied as per engineer in charge instructions.

4

5191

20766.72

... More
Supply of HDPE duct 40/33 mm as per TEC GR No. G/CDS 08/02 NOV-2004 with latest 8 amendments as available. For each Km of HDPE duct following items are to be supplied a) End Plugs- 2no b) Cable sealing plugs -2 no. (c ) Plastic couplers slip fit/push fit type - 2no d) End plugs to be provided along with drum -2 nos

1

57743

57743.05

... More
Suppy of 10/12 pairs CT box for termination cables as per the details approved by the engineer. All the required materials shall be supplied by the contractor.

4

1564

6259.48

... More
Supply of 4/2 wire portable emergency control telephone as per IRS -TC- 75/99 (Amd-2) with latest amendments along with std. length cord and 6 pin plug as per spec no. IRS TC 42/87 (Amd-1) or latest.

4

3026

12105.48

... More
Supply of CLI push button telephones (CLI and Handsfree facility) suitable for connection with way side equipment and the system entioned above. as per DOT/TEC specifications TEC/GR/CP/Tele/-002/05 Jan- 2010 with latest amendment IRS TC: 38/97 Amd.1 & from DOT/TEC approved firms. Ch-5 Part 2 item no 5.

4

874

3497.04

... More
Supply Emergency Socket Box in FRP material used in 25 KV RE areas as per RDSO spec. no. RDSO/SPN/TC/44/2002 Ver. 2 with Amendments I & II

4

840

3360.68

... More
Supply of ultra isolation transformer 230V/230V-1.5 KVA with MOVR protection on either side to 14 provide X protection and supply of crow bar surge protection circuit for 48v DC side to provide Y protection as per the schematic diagram (at HQ) supplied by the railways. Conforming to clause no.3.22 of Technical specification, tender documents and telecom manual and WR practices.

4

10233

40935.24

... More
Flexible cable (Power wire), multi-strand copper conductors cross section (1x16Sq.mm).101 Conductors each diameter 0.45 + 0.01 as per IS 694/2010 with insulation thickness of 1.2mm nominal conductor resistance 1.127 Ohms/Km and test parameters as per IRS(S) 76/89.

0.2

-

34883.36

... More
Supply of SWITCH BOARD CABLE (10PAIR) CONFIRNING TO ITDSPECIFICATION G/WIR-06/03 MAR02 OR LATEST MAKE:-NETWORKCABLE OR SIMILAR.

400

50

20152

... More
Megger: Analog-Digital Insulation and continuity tester as per technical specification.

2

7268

14537.6

... More
Supply of Netgear /D-Link/Hikvision 8port POE switch with fast ethernet or higher unmanaged switch with 60 watt capacity. Accepted firms offer Make: hikvision

4

3245

12980

... More
Supply of Surge protection device (SPD) 4- Pole, 5 V versions as detailed in specification similar to model no MDP- 4 D-5-T of OBO make. Make OBO, Phoenix, ABB or DEHN. Detailed specification.

4

4849

19399.2

... More
Rish Multimeter 18S IR or similar, as per technical specification.

2

20845

41690

... More
LAN TESTER compatible and suitable with Cat 5,Cat 6e cable & RJ 45 . Make/model: LED Fluke,3C3LED LAN, Cable Master 200 or similar or latest. As per attached specification

4

531

2124

... More
Supply of Light Weight portable control telephone as per RDSO specification no.IRSTC 78/2000 with Amdt.2 or latest

4

1681

6726

... More
Supply of PVC Switch Board 5 Pair 0.5MM DIA ANNEALED COPPER TELEPHONE CABLE.

200

27

5450

... More
20 pair pvc indoor cable 0.5 mm dia as per attached specification. Make:phinolex or Network cable or similar

200

119

23968

... More
Tool Kit consisting of Optical powermeter(Fibershot9990V),Multimeter(Fluke101),Ethernet 25 Crimping tool(StandardMake)Console cable(Cisco=RJ45-DB9),Wrist ripper(StandardMake),Universal Spanner Set (Taparia),Screw Driver Set (Taparia-7Pieces set),Cutting plier(Taparia), Wire Stripper,Industrial grade USB to Serial cable withall accessories or Similar.[DetailedSpecification in Technical Document].Inspection: Consignee

2

18498

36997.32

... More
Supply of LAN Extender asper RDSO Specifications RDSO/SPN/TC/82/2020Rev.2.0. as per technical specification.

4

26066

104266.28

... More
supply of optical to ethernet media converter for single mode single fiber as per RDSO specification RDSO/SPN/TC/103/2013 rev2 or latest of make D-link/ TP-link/ Tenda as per technical specification.

4

2014

8059.8

... More
Supply of Single Mode Singlefiber Managed MediaConverter (Ethernet & E1 toOptical vice versa) Pair andall the accessories requiredfor their installation as perRDSO SpecNoRDSO/SPN/TC/103/2013Rev.2 or latest. as pertechnical specification.

4

11754

47016.28

... More
Supply of E1 extender (24v at datalogger end) with following specifications: operations on 2- 29 wirecopper circuits using G'SHDSL' Driving range:6.5 km at 2048 kbps on 24 AWG(0.5mm dia) unloaded copper pair under error -free conditions. Power supply input-options for 230VAC, 48VDC, 24VDC or various combinations 'Make:Cygnus/Anda/Team link orsimilar (Should be supply in pair)

4

19006

76024.72

... More
Excavation of trench 300mm wide at the bottom and 1.2 mtr deep, in all type of soils including clearing of trees, bushes, etc. and refilling of cable trench by excavated soil and ramming after laying of HDPE DUCT (laying of HDPE/DWC & 6 Quad. cables, PDF cables etc., will be paid under different items of the 1 schedule). Where desired dimensions of trenches could not be achieved proportionate payment will be made as decided by Engineer-in-charge of the Railway at site. The trenching outside the station limits I.e.) between the home signal of station 'A' to home signal of station 'B' may be done manually or by machine, as per the directions of site in charge. In no case the payment will be made for the trench of higher dimensions, than the dimensions as mentioned above Running

288

305

87851.52

... More
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50m and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.

20

449

8995.4

... More
Splicing of laid under above items OFC cable and making the splice joint in dust free environment with contractor's own equipments and labour. Straight joint enclosure (SJC) is covered under schedule 'A' remaining all required materials, tools , plants shall be arranged by the contractor. splicing shall be started from 6 one end and each splicing shall be monitored after splicing and after closing the enclosure for all the fibers from one central location by contractor's engineer with his own OTDR and optic Talk set with railway engineer , trace for the fibers shall be taken and signed jointly, if any fibred splice shows high loss/lossy event, the same shall be redone before completion of splicing work. The splice loss shall be as per the policy/technical circulars issued by the railways from time to time.

8

8485

67882.32

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the end of duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

1

6492

6492.63

... More
Laying of OFC/Quad Cable, PIJF cable of different size in the excavated trench. This includes 8 loading/unloading & transportation of cables from the stores of SSE/T/C/ADI to the site/ Wherever several cables of provision of separation of various cables should be as advised by the site incharge of the Railway. Empty cable drums to be retained by the contractor the cable drums with unused cable at site to be returned by the contractor from site to be returned by the contractor from site to Stores.

1

7697

7697.48

... More
Blowing of OFC through HDPE duct & protective work (elicited in above item) already provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC 9 shall be drawn /laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. In case OFC is to be laid adopting 'Direct in trench' method then this item shall be paid as per accepted rate of item of this schedule. OFC and HDPE pipe shall be supplied by the railway.

0.8

-

9910.5

... More
Execution of quad cable jointing using thermo shrinkable joint kit straight though/ Derivation / 2T / 10 3T transformer joints with VF transformer between 6 quad & PIJF cable this i/c transformers on 6 quad / jelly field cable this i/c VF transformation of jointing kit transformer covered in Schedule 'C'.

8

1308

10469.12

... More
Cement concrete work for miscellaneous items in the ration 1:3:6, Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm) (aggregate cement and sand to be supplied by the contractor)

4

3786

15145.2

... More
Jointing of 4 / 6 quad /Signaling cable with Heat Shrinkable straight through Jointing Kit. All the 12 material required for the work are to be arrange by contractor himself at his own cost except Thermo shrinkable Joint Kit . After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost.

8

1177

9421.76



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.