Western Railway Tender
... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 2,15,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Electrical Work In Connection With Provision Of Air Conditioning In The Office Of Sr.dom/adi & Sr.dcm/adi At Ahmedabad.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
EL-50-1-ADI-T-77-2024-25-AHMEDABAD DIVISION-ELECTRICAL/WESTERN RLYTender No
EL-50-1-ADI-T-77-2024-25Tender Authority
Western Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, installation, testing and commissioning of LT panel having 2 Nos. 400 Amp. 04 MCCB FP Microprocessor based as incoming and 4 Nos. 63 Amp. MCCB FP as outgoing with multifunction meter, indicator lamp and all associate accessories as per technical specification shown in Para (D) of Annexure.
-
-
163594
... More
Supply of ISI marked XLPE armoured aluminium LT cable of 4 Core 400 Sq. mm as per technical specification shown in Para (E) of Annexure.
-
-
2055200
... More
Supply of ISI marked XLPE armoured aluminium LT cable of 4 Core 50 Sq. mm as per technical specification shown in Para (E) of Annexure.
-
-
160800
... More
Supply of 6 Kg capacity DCP fire extinguisher as per technical specification shown in Para (G) of Annexure.
-
-
4052
... More
Supply, erection/fixing of fire extinguisher equipment, rubber mat, GI fire bucket 09 filled with clean dry sand held on free standing steel stand, First Aid box with medicines and associate material, shock treatments chart on aluminum frame and 6 mm thick glass on front schematic diagram of HT/LT installation and transformer data on white hylem sheet with aluminum frame and fixing in the substation as per technical specification shown in Para (H) of Annexure.
-
-
8938
... More
Supply of ISI marked 11 KV rubber mat as per technical specification shown in Para (I) of Annexure.
-
-
2194
... More
Supply, installation, testing and commissioning of 25 x 3 mm GI strip for earthing as per technical specification shown in Para (J) of Annexure.
-
-
14800
... More
Supply of material and providing maintenance free earthing as per technical specification shown in Para (K) of Annexure.
-
-
93912
... More
Supply of material and providing copper plate 600 mm X 600 mm X 3.5 mm earthing as per technical specification shown in Para (L) of Annexure.
-
-
33718
... More
Horizontal Direction Drilling/boring without damage of surface road using auger 14 machine the bore shall be 150mm dia. and shall be done at the depth of minimum 1.5 meter or as requirement of site from the ground level this include insertion of 110mm dia. HDPE pipe as per technical specification shown in Para (M) of Annexure.
-
-
429200
... More
Supply, installation, testing and commissioning of HDPE pipe 110 mm nominal dia. as per IS 4984-1995 and as per technical specification shown in Para (M) of Annexure.
-
-
229600
... More
Digging of cable trench 450 x 1000 mm. in RCC/PCC/hard soil & refilling as per technical specification shown in Para (N) of Annexure.
-
-
46100
... More
Digging of cable trench 450 x 1000 mm & refilling as per technical specification shown in Para (O) of Annexure.
-
-
18800
... More
Transportation, laying, installation, terminating, testing and commissioning of LT/HT cable of sizes 4 core 10 sq. mm. to 4 core 300 sq. mm. in existing trench, pipe or on structure as per technical specification shown in Para (P) of Annexure.
-
-
37000
... More
Supply and laying of half round RCC pipe 150 mm. ID & 1 mtr. length as per technical specification shown in Para (Q) of Annexure.
-
-
20700
... More
Supply, installation, testing & commissioning of LT cable route marker as per technical specification shown in Para (R) of Annexure.
-
-
1015
... More
Supply, installation, testing and commissioning of 14 SWG 100 mm width x 75 mm depth GI perforated powder coated cable tray with cover as per technical specification shown in Para (S) of Annexure.
-
-
82100
... More
Supply of 5 star rated 1200 mm BLDC ceiling Fan as per technical specification shown in Para (T) of Annexure.
-
-
7378
... More
Fixing, testing and commissioning of fan with supply, fixing, testing and commissioning of EME type Fan regulator as per technical specification shown in Para (T) of Annexure.
-
-
952
... More
Supply, installation, testing and commissioning of 20W LED tube light fitting IP 20 complete with tube and all accessories. The contractor shall provide the mounting arrangement for fittings as required at site and as per technical specification shown in Para (U) of Annexure.
-
-
2030
... More
Supply of material and carry out concealed wiring of Light/Fan Points without pipe up to 6 meters with FRLS PVC insulated, multi strand three Nos. copper wires of 1.5 sq. mm for phase, 25 neutral and earth continuity conforming to IS-694 (as amended latest). The point wiring shall include supply & providing modular switches with complete associate accessories such as chromium plated metal boxes, modular plates, cover plate, lamp holders, three pin ceiling rose, adopter etc. as per technical specification shown in Para (V) of Annexure. Note: Beyond 6 meter wiring additional payment will be done through NS item.
-
-
4880
... More
Supply and laying in wall & ceiling in concealed manner of ISI marked medium class rigid 25 mm. dia. PVC conduit pipe with all accessories as per technical specification shown in Para (V) of Annexure.
-
-
4900
... More
Supply of materials and wiring of main/sub main in concealed manner with 4 mm. sq. 27 size multistrand FRLS PVC insulated ISI marked copper wire for phase, neutral & one number 2.5 sq. mm. copper wire for earth continuity with PVC conduit pipe as per technical specification shown in Para (V) of Annexure.
-
-
54000
... More
Supply of materials and wiring of main/sub main in concealed manner with 4 mm. sq. 28 size multistrand FRLS PVC insulated ISI marked copper wire for phase, neutral & one number 2.5 sq. mm. copper wire for earth continuity without PVC conduit pipe as per technical specification shown in Para (V) of Annexure.
-
-
21000
... More
Supply, fixing, testing and commissioning of 2 Nos. 6 Amps 5 pin socket with modular switch for each socket on separate board in concealed manner as per technical specification shown in Para (V) of Annexure.
-
-
728
... More
Supply, fixing, testing and commissioning of 4 Nos. 6 Amps 5 pin socket with modular switch for each socket on separate board in concealed manner as per technical specification shown in Para (V) of Annexure.
-
-
667
... More
Supply, fixing, testing and commissioning of 6 Amps 5 pin modular socket with modular switch in concealed manner on an existing board where phase and neutral are already available as per technical specification shown in Para (V) of Annexure.
-
-
860
... More
Supply, fixing, testing and commissioning of 16 Amps multi pin socket with modular switch on separate board with all accessories as per technical specification shown in Para (V) of Annexure.
-
-
8800
... More
Supply, installation, testing and commissioning of distribution board panel having 63A MCB FP as incoming and 4 Nos. 16Amp. 30mA sensitivity RCBO DP as outgoing with all associate accessories as per technical specification shown in Para (W) of Annexure.
-
-
78504
... More
Supply of 3 core 2.5 Sq. mm flexible FRLS copper cable as per technical specification shown in Para (X) of Annexure.
-
-
76000
... More
Supply, installation, testing and commissioning of 90 mm outer dia. and 75 mm inner dia. DWC pipe as per technical specification shown in Para (Y) of Annexure.
-
-
3650
... More
Supply, installation, testing and commissioning of MS plate for covering trench with MS material clamp, nut bolt and all required accessories for MS plate, two coat red oxide colour with single coating of black colour as per technical specification shown in Para (Z) of Annexure.
-
-
17500
... More
Supply, installation, testing and commissioning of 45 x 45 mm PVC cable ducts as per technical specification shown in Para (AA) of Annexure.
-
-
8250
... More
Supply, installation, testing and commissioning of 50 KVAR APFC panel as per technical specification shown in Para (BB) of Annexure.
-
-
187910
... More
Supply, installation, testing and commissioning of heat shrinkable indoor end termination kit suitable for 4 core 400 Sq. mm LT cable as per technical specification shown in Para (B) of Annexure.
-
-
22742
... More
Horizontal Direction Drilling/boring without damage of surface road using auger 03 machine the bore shall be 150mm dia. and shall be done at the depth of minimum 1.5 meter or as requirement of site from the ground level this include insertion of 110mm dia. HDPE pipe as per technical specification shown in Para (M) of Annexure.
-
-
429200
... More
Supply, installation, testing and commissioning of HDPE pipe 110 mm nominal dia. as per IS 4984-1995 and as per technical specification shown in Para (M) of Annexure.
-
-
229600
... More
Supply, installation, testing and commissioning of LT Panel having 2 Nos. 400 Amp. 05 MCCB FP Microprocessor based as incoming and 1 No. 400 Amp. on load auto changeover switch, 3 Nos. 125 Amp. MCCB FP & 2 Nos. 63 Amp. MCB FP as outgoing with multifunction meter & indicator lamp and all associate accessories as per technical specification shown in Para (CC) of Annexure.
-
-
255202
... More
Supply, installation, testing and commissioning of DB panel having 1 No. 125 Amp. MCCB FP as incoming and 8 Nos. 32 Amp. MCB DP as outgoing with Ammeter, voltmeter, indicator lamp and all associate accessories as per technical specification shown in Para (DD) of Annexure.
-
-
70407
... More
Supply of ISI marked XLPE armoured aluminium LT cable of 4 Core 400 Sq. mm as per technical specification shown in Para (E) of Annexure.
-
-
2055200
... More
Supply of ISI marked XLPE armoured aluminium LT cable of 4 Core 120 Sq. mm as per technical specification shown in Para (E) of Annexure.
-
-
449600
... More
Supply of ISI marked XLPE armoured aluminium LT cable of 4 Core 70 Sq. mm as per technical specification shown in Para (E) of Annexure.
-
-
130350
... More
Digging of cable trench 450 x 1000 mm. in RCC/PCC/hard soil & refilling as per technical specification shown in Para (N) of Annexure.
-
-
46100
... More
Digging of cable trench 450 x 1000 mm & refilling as per technical specification shown in Para (O) of Annexure.
-
-
9400
... More
Transportation, laying, installation, terminating, testing and commissioning of LT/HT cable of sizes 4 core 10 sq. mm. to 4 core 300 sq. mm. in existing trench, pipe or on structure as per technical specification shown in Para (P) of Annexure.
-
-
24050
... More
Supply and laying half round RCC Pipe 100 mm. ID & 1mtr. length as per technical specification shown in Para (EE) of Annexure.
-
-
9300
... More
Supply, installation, testing & commissioning of LT cable route marker as per technical specification shown in Para (R) of Annexure.
-
-
609
... More
Supply, installation, testing and commissioning of 16 SWG 100 mm width x 75 mm depth GI perforated powder coated cable tray with cover as per technical specification shown in Para (FF) of Annexure.
-
-
56800
... More
Supply of 3 core 10 Sq. mm flexible FRLS copper cable as per technical specification shown in Para (GG) of Annexure.
-
-
301000
... More
Supply, installation, testing and commissioning of 40 x 30 mm PVC cable ducts as per technical specification shown in Para (HH) of Annexure.
-
-
64000
... More
Supply of 25 mm dia. PVC conduit pipe as per technical specification shown in Para (II) of Annexure.
-
-
5100
... More
Supply of ISI marked 11 KV rubber mat as per technical specification shown in Para (I) of Annexure.
-
-
4388
... More
Supply of 6 Kg capacity DCP fire extinguisher as per technical specification shown in Para (G) of Annexure.
-
-
8104
... More
Supply, installation, testing and commissioning of new 4.0 ton capacity 4 way cassette AC unit with indoor & outdoor units as per technical specification shown in Para (JJ) of Annexure.
-
-
1924590
... More
Supply & installation of refrigerant piping with insulation between indoor and outdoor units as per technical specification shown in Para (KK) of Annexure.
-
-
435250
... More
Supply & installation of power and control cables between indoor and outdoor units laid in PVC pipe and clamp of suitable size as per technical specification shown in Para (LL) of Annexure.
-
-
36250
... More
Supply, installation, testing and commissioning of charges along with topping up of refrigerant as per technical specification shown in Para (MM) of Annexure. 26
-
-
15960
... More
RCC core cutting as per technical specification shown in Para (NN) of Annexure.
-
-
14505
... More
Supply & installation of M.S. stand for outdoor units. The stand should be made of MS angle and duly painted with one coat primer and two coats of anti-corrosive paint as per technical specification shown in Para (OO) of Annexure.
-
-
74145
... More
Supply, installation, testing and commissioning of PVC drain piping for unit with insulation as per technical specification shown in Para (PP) of Annexure.
-
-
36250
... More
Supply, installation, testing and commissioning of 14 SWG 150 mm width x 75 mm depth GI powder coated ladder type cable tray with cover as per technical specification shown in Para (QQ) of Annexure.
-
-
185400
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%