Military Engineer Services Tender

... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date10 Mar 2025
Closing Date29 Mar 2025
Tender Amount₹ 49,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OIL PRESSURE GAUGE

3

-

-

... More
AIR CLENER ELEMENT

3

-

-

... More
ELBOW HUMP HOSE

3

-

-

6

-

-

... More
FUEL SUPPLY & RETURN HOSE

3

-

-

... More
RADIATOR HOSE SET

3

-

-

... More
FAN BELT

6

-

-

... More
BELT ATERNATOR

3

-

-

... More
FLY WHEEL RING GEAR

3

-

-

... More
Supply & fixing in replacement of the following spare parts of Sudhir WITH 400 KVA DG SET at FIRE FIGHTING P/H for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
Oil FILTER

1

-

-

... More
DIESEL FILTER

1

-

-

... More
OIL PRESSURE GAUGE

1

-

-

... More
AIR CLEANER ( OUTER )

1

-

-

... More
AIR CLEANER ( INNER )

1

-

-

... More
FAN BELT

1

-

-

... More
UNIBALL JOINT

1

-

-

... More
THERMOSTATE

1

-

-

... More
HOSE DIESEL ( 7 Ft. )

1

-

-

... More
DIESEL FILTER PUMP HOSE

1

-

-

... More
Servicing for DG Set 82.5 KVA Capacity, Make - CUMMINS NTA 495 G ENGINE installed at Map Officer Md Accn drain out engine oil from sump, cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement of following worn out spare parts for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER WITH O RING

1

-

-

... More
OIL FILTER WITH O RING

1

-

-

... More
SUPER BYPASS FILTER WITH O RING

1

-

-

... More
AIR CLEANER ELEMENT

1

-

-

... More
Servicing for DG Set 82.5 KVA Capacity, Make - Kirloskar installed at HQ SWAC AFNET & DSC Lift, drain out engine oil from sump, cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement of following worn out spare parts for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER WITH O RING

2

-

-

... More
OIL FILTER WITH O RING

2

-

-

... More
SUPER BYPASS FILTER WITH O RING

2

-

-

... More
AIR CLEANER ELEMENT

2

-

-

... More
Servicing for DG Set 82.5 KVA Capacity, Make:- Kirloskar, installed at , Ashok leyand installed at Telephone Exchange SWAC drain out engine oil from sump,cleaning and filling up with new engine oil as per recommended grade & quality & including repair/ replacement of following worn out spare parts for smooth running at rated speed complete all as manufacture specification & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER WITH O RING

1

-

-

... More
OIL FILTER WITH O RING

1

-

-

... More
SUPER BYPASS FILTER WITH O RING

1

-

-

... More
AIR CLEANER ELEMENT

1

-

-

... More
Battery lead

2

-

-

... More
Supply & fixing in replacement of the following spare parts of DG Set 250 KVA, CUMMINS NTA 855 G ENGINE, Make : MRS-02 for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER WITH O RING

2

-

-

... More
OIL FILTER WITH O RING

2

-

-

... More
SUPER BYPASS FILTER WITH O RING

2

-

-

... More
AIR CLEANER ELEMENT

2

-

-

... More
RUBBER INSERT

2

-

-

... More
ALUMINIUM COUPLING( ALTERNATOR)

1

-

-

... More
Supply & fixing in replacement of the following spare parts of DG Set 250 KVA, Kirloskar, behind - swming pool C&C DG SET for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER WITH O RING

1

-

-

... More
OIL FILTER WITH O RING

1

-

-

... More
SUPER BYPASS FILTER WITH O RING

1

-

-

... More
AIR CLEANER ELEMENT

1

-

-

... More
RUBBER INSERT

1

-

-

... More
ALUMINIUM COUPLING (ALTERNATOR)

1

-

-

... More
FLY WHEEL RING GEAR

1

-

-

... More
Supply & fixing in replacement of the following spare parts of DG Set 250 KVA, Greaves, HQ SWAC server for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER WITH O RING

1

-

-

... More
OIL FILTER WITH O RING

1

-

-

... More
SUPER BYPASS FILTER WITH O RING

1

-

-

... More
AIR CLEANER ELEMENT

1

-

-

... More
RUBBER INSERT

1

-

-

... More
ALUMINIUM COUPLING (ALTERNATOR)

1

-

-

... More
FLY WHEEL RING GEAR

1

-

-

... More
Supply & fixing in replacement of the following spare parts of DG Set 380 KVA, KIRLOSKAR DV 10 ENGINE, ESN. DVO 9005/1200007 at MAP PH1, MAP PH2 & MAP PH3 for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER

3

-

-

... More
OIL FILTER

3

-

-

... More
AIR CLEANER ELEMENT (INNER )

3

-

-

... More
AIR CLEANER ELEMENT (OUTER )

3

-

-

... More
Supply & fixing in replacement of the following spare parts of DG Set 1250 KVA, CUMMINS at SWAC HQ AC Plant for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER WITH O RING

1

-

-

... More
OIL FILTER WITH O RING

1

-

-

... More
SUPER BYPASS FILTER WITH O RING

1

-

-

... More
AIR CLEANER ELEMENT

1

-

-

... More
BREATHER RED HOSE

2

-

-

... More
CLAMP

12

-

-

... More
DIESEL HOSE

1

-

-

... More
HUMP HOSE

2

-

-

... More
ELBOW HUMP HOSE

2

-

-

... More
Supply & fixing in replacement of the following spare parts of DG Set 62.5/63 KVA, at Type-III accn -02 Nos & Swac P/H and guard room for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
FUEL FILTER

4

-

-

... More
OIL FILTER

4

-

-

... More
DOOR LOCK HINGES

6

-

-

... More
Supply & fixing in replacement of the following spare parts of DG Set 200 KVA, Make - CUMMINS at Officer Md Area/PH/Sub Stn No 2 for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER

1

-

-

... More
OIL FILTER

1

-

-

... More
WATER FILTER

1

-

-

... More
DOOR LOCK HINGES

1

-

-

... More
Supply & fixing in replacement of the following spare parts of DG Set 200 KVA, Make - Greaves at AFNET for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER

1

-

-

... More
OIL FILTER

1

-

-

... More
WATER FILTER

1

-

-

... More
DOOR LOCK HINGES

1

-

-

... More
All as per Item No. 13 hrer-in before but DG set capcity 140 KVA, Mahindra & Mahindara installed at SMC:-

-

-

-

... More
AIR FILTER

1

-

-

... More
FAN BELT

1

-

-

... More
HOSE THERMOSTATE TO RADIATOR

1

-

-

... More
DIESEL FILTER

1

-

-

... More
OIL FILTER SPINON

1

-

-

... More
DIESEL SUPPLY HOSE

1

-

-

... More
DIESEL RETURN HOSE

1

-

-

... More
Supply & fixing in replacement of the following spare parts of Mahindra and Mahindra 35 KVA at MES IB & S/STN-02 for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
FUEL FILTER

2

-

-

... More
LUB OIL FILTER

2

-

-

... More
WATER SEPARATOR

2

-

-

... More
AIR CLEANER SET

2

-

-

... More
Supply & fixing in replacement of the following spare parts of Kirloskar 30 KVA at DSC Gate, for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER

1

-

-

... More
OIL FILTER

1

-

-

... More
AIR FILTER

1

-

-

... More
Supply & fixing in replacement of the following spare parts of Greaves 10 KVA at Guard room, AF School & SMC (STP Pump House) for its smooth operation & better performance complete all as specified and directed:-

-

-

-

... More
DIESEL FILTER

4

-

-

... More
OIL FILTER

4

-

-

... More
AIR FILTER

4

-

-

... More
Supply and connecting in repair of battary 180 Ah 12 Volt, maintainenace free heavy duty with battery terminals and copper lead for +ve and -ve ends with complete fixing and testing.

4

-

-

... More
Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 1250 KVA complete all as specified and as directed.

720

-

-

... More
Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 1250 KVA complete all as specified and as directed.

380

-

-

... More
Supply and filling distal water for inside the battery and charge properly to maintain battery voltage for 15 KVA to 1250 KVA DG Sets complete all as specified and as directed.

140

-

-

... More
Supply, and connecting in repair of battary 150 AH 12 Volt, maintainenace free heavy duty with battery terminals and copper lead for +ve and -ve ends with complete fixing and testing complete all as specified and as directed.

4

-

-

... More
M&L for dismantling of complete radiator assy form engine and taking out all, dissclaing, rusty, sludg and mudy particals inside the radiator by using of sodium hydroxide with water pressure cleaning complete and refixing the radiator assy on its exsisting position and testing complete for its satisfactory perfomance with entire satisfaction of Engineer-in-Charge:-

-

-

-

... More
For DG Set capacity 10 KVA to 110 KVA

4

-

-

... More
For DG Set capacity 125 KVA to 250 KVA

4

-

-

... More
For DG Set capacity 380 KVA to 1250 KVA

2

-

-

... More
Taking out old burnt out Automatic voltage regulator from DG set alternator and S&F suitable capacity of automatic voltage regulator complet testing and checking voltage regulation of the DG set after full load position of DG set for its satisfactory performance complete all as specified and directed by Engineer-in-Charge:-

-

-

-

... More
For DG Set capacity 15 KVA to 110 KVA

4

-

-

... More
For DG Set capacity 125 KVA to 250 KVA

2

-

-

... More
For DG Set capacity 380 KVA to 1250 KVA

1

-

-

... More
M&L for preparation of old painted surfaces of the DG set and fuel tank of following capacity by cleaning oilly and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / aleternator complete all as specified and directed. Note:- Colour code to be followed as under:- (i) Engine body - OG. (ii) Alternator - Siemes grey (iii) Fly wheel guard - Red (iv) Radiator - Black

-

-

-

... More
For DG Set capacity 15 KVA to 110 KVA

3

-

-

... More
For DG Set capacity 125 KVA to 250 KVA

2

-

-

... More
For DG Set capacity 320 KVA to 1250 KVA

2

-

-

... More
M&L taking out alternator from exsisting position after disconecting all electrical connection and de-coupling from engine assy and transprting to repair workshop, dismantling the alternator taking out stator/rotor/excitor coil, rewinding and re-vernishing the complete coil heating up for dehydration of moisture cleaning servicing grecing of complete alternator including replacement of bearing re-assembling the alternator complete and transporting to site , refixing the alterator on its exsisting position including coupling with engine assy connection of cable complete all as specified and testing for its satisfactory performance all as specified and directed by Engineer-in-Charge:-

-

-

-

... More
For DG Set capacity 50 KVA to 110 KVA

1

-

-

... More
For DG Set capacity 125 KVA to 250 KVA

1

-

-

... More
For DG Set capacity 320 KVA to 1250 KVA

1

-

-

... More
M&L for Dismantling the self startor assy from engine and repair servicing of startor by replacing old work out bearing bushing armature coil soloniod switch etc. re-assembling the complete startor fixing the same on engine and testing for its satisfactory performance complete all as specified and directed:-

-

-

-

... More
For DG Set capacity 50 KVA to 110 KVA

4

-

-

... More
For DG Set capacity 125 KVA to 250 KVA

2

-

-

... More
For DG Set capacity 380 KVA to 1250 KVA

4

-

-

... More
M&L for disconnection of Diesel Oil tank with inlet and outlet disel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil partical complete and refixing after at the same place and conncting complete with existing system including marking of tank showing the capacity in Ltrs and repalacement of transparent PVC pipe complet all as directed by Engineer-in-Charge:-

-

-

-

... More
For DG Set capacity 50 KVA to 110 KVA

6

-

-

... More
For DG Set capacity 125 KVA to 250 KVA

4

-

-

... More
For DG Set capacity 380 KVA to 1250 KVA

4

-

-

... More
M&L for visit of DG SET for checking of serviceabillity report and submitted at office as per direction of Eng-in-Charge as under:-

-

-

-

... More
For DG Set capacity 10 KVA to 110 KVA

14

-

-

... More
For DG Set capacity 125 KVA to 250 KVA

10

-

-

... More
For DG Set capacity 380 KVA to 1250 KVA

6

-

-

... More
S&F in repair 12 Volt 10 Amps Auto charge Battery charger with fitment complet with necessary cable connection as frequired for fixing complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
S&F in repair 24 Volt 10 Amps Auto charge Battery charger with fitment complet with necessary cable connection as frequired for fixing complete all as specified and directed by Engineer-in-Charge.

6

-

-

... More
S&F in repair MCCB 250 Amp 4 pole 415 volt 36 kA breaking capacity adjustable type complete all as specified and directed.

4

-

-

... More
S&F in repair MCCB 400 Amp 4 pole 415 volt 36 kA breaking capacity adjustable type complete all as specified and directed.

1

-

-

... More
S&F in repair MCCB 630 Amp 4 pole 415 volt 36 KA breaking capacity adjustable type complete all as specified and directed.

1

-

-

... More
S&F in repair on load change over switch as open execution 250 A, 415 V, complete all as specified and as directed

1

-

-

... More
S&F in repair on load change over switch as open execution 400 A, 415V, complete all as specified and as directed.

2

-

-

... More
S&F in repair on load change over switch as open execution 630 A, 415 V, AC 23 A, 4P complete all as specified and as directed.

1

-

-

... More
Supply, install, testing & commissioning in replacement of faulty TC contactor for DG Set up to 110 KVA, As per exisiting model 415 Volt rated capacity with coil voltage and connected relays all as specified and directed by E-in-Charge

6

-

-

... More
Supply, install, testing & commissioning in replacement of faulty TC contactor for DG Set 125 KVA to 1250 KVA, As per exisiting model 415 Volt rated capacity with coil voltage and connected relays all as specified and directed by E-in-Charge

4

-

-

... More
Supply, install, testing & commissioning in repairs controller - Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connection good and renewed for upto DG set 200 KVA as per existing make complete all as specified and directed by Engr-in-charge.

5

-

-

... More
Supply, install, testing & commissioning in repairs controller - Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connection good and renewed for DG set 250 KVA to 1250 KVA as per existing make complete all as specified and directed by Engr-in-charge.

4

-

-

... More
Supply,install,testing & comissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge,

4

-

-

... More
S&F in repair digital three phase voltmeter 0-500 Volts of size 96x96mm complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
S&F in repair digital three phase Ampere meter 0-500 Volts of size 96x96mm complete all as specified and as directed by Engr-in-Charge.

3

-

-

... More
S&F in repair solenoid switch as per existing sample for 10 KVA to 1250 KVA DG set complete all as specified and as directed.

6

-

-

... More
M&L for servicing of AMF Panels for DG Set including internal wiring connections, relay setting, setting of pick up time for auto start of DG Set, arranging the doors of panels by welding to the compartment, rearranging and tightening of lugs for cable connections, cleaning dust by vacumm cleaner, replacing the contactors for Main/DG Supply if found unserviceable under the respective item of this schedule testing the DG Set for auto/manual start by running the DG Set for 01 Hrs all as specified and directed by Eng-in-Charge. Note:- The additional cost for internal wiring, PCB service, lugs and programming of the ckt will be included in this item.

5

-

-

... More
M&L for rewinding and preventive maintenance of Chimini including rewinding at Airmen Mess, SNCO's mess and officer mess complete all as specified and as directed.

3

-

-

... More
Comprehensive maintenance of sliding doors including greasing and oiling of rack and pinion gears and wheels of doors and replacing the wheels and supportiong rollers if found unservceable at HQ SWAC complete all as specified and directed by Eng-in-Charge.

4

-

-

... More
M&L for servicing of LT Control panels of sliding doors including wiring and making all electrical connections good and tight to avoid chances of any shortcircuiting and replacing the faulty PCB, sensors and relays and making functional all sensors to control any obstruction in between in moving door if found unservceable at HQ SWAC complete all as specified and as directed by Eng-in-Charge.

4

-

-

... More
M&L for taking out & rewinding the existing unserviceable burnt motors of Sliding Doors of Cap 03 HP, Three phase, 50 cycles by disconnecting electrically and mechanically and transporting to the locally workshop. Dismantling the motor and removing the old burnt copper winding & demoisturise, cleaning, rewinding the coils with same gauge supper enamelled copper wire, with suitable F class paper insulation, varnishing, and reassembling by replacing bearings reinstalling at the installation and testing, commissioning etc complete all as specified and as directed by Engr-in-Charge.

4

-

-

... More
M&L for servicing of sliding door motors of Cap 3 HP operated on 240 V, 50 Hz with replacing of box set-04 Nos, mechanical seal - 01 No, cut off switch 01 No, bearing 02 Nos, Air filling in tank complete as per site requirement or as directed by Engr-in-Charge.

4

-

-

... More
M&L for servicing of sliding door gear boxes by replacing of oil seal-02 Nos, mechanical seal - 01 No, refilling of lubrication oil 15W40, bearing 02 Nos, complete as per site requirement or as directed by Engr-in-Charge.

4

-

-

... More
S&F in repair MS Support Rollers for sliding doors at HQ SWAC Chiloda proper support of sliding doors all as specified and directed by Engr-in-Charge.

4

-

-

... More
S&F in repair rack of sliding doors with milled/ hobbed gear tooths as existing pattern and welding the rack to the Gates at HQ SWAC Chiloda for proper movement of pinion over the rack so that any chances for sliping may get avoided complete all as specified and directed by Engr-in-Charge.

5

-

-

... More
S&Fx in repair MS gears wheel of Dia upto 80 mm with hobbed/ milled spur gear tooths and fixing to the motor shafts by inserting sunk key and making provision for key way complete all as specified and directed by Eng-in-Charge.

3

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanised iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge.

290

-

-

... More
NOTE:- For above item No 1 to 57, During faults and unserviceability of parts information given by JE/ Engr-in-Charge to Contractor, he should address and rectify with in 02 hrs otherwise penalty of Rs 5000/- per day will be recovered.

-

-

-

... More
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc completed all as specified and directed.

179

-

-

... More
Returning, filling including spreading, leveling watering & well ramming in laying not exc. 25cm for soft/ loose soil completed all as specified and directed.

114

-

-

... More
Removal of excavated material at a distance not exc 50 mtr and dipositing where directed at a level not exc. 1.5 mtr above the starting point for soft/loose soil complete all as specified and as directed.

65

-

-

... More
M & L for dry Sand cushioning to underground cable with screened, washed river sand, including punning gently completed all as specified and directed. Note: - Thickness after punning will be measured for payment.

53

-

-

... More
Supply and laying for burnt brick old size sub class `B' laid in trenches abutting each other with a gap not exceeding 10 mm, vertically over the cable for cable protection completed all as specified and directed.

5.2

-

-

... More
Supply and laying in trenches in road cross / floors 80 mm bore tube galvanished iron light grade with all fittings for protection of cable complete all as specifed and as directed.

18

-

-

... More
Supply and laying in trenches in road cross / floors 50 mm bore tube galvanished iron light grade with all fittings for protection of cable complete all as specifed and as directed.

18

-

-

... More
Labour only for boring under road/drain by manual method for inserting GI tubing up to 100 mm dia for cable protection complete all as specified and directed by Engineer In Charge.

46

-

-

... More
Taking down / out underground LT cable of aluminium conductor of up to 300 Sqmm of any core after disconnecting from sheet metal encloser / panel board or from OH line and taking out from trenches including taking out brick cable cover complete all as specified and directed. Note :- Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.

700

-

-

... More
Relaying of serviceable HT/LT under ground cable (4x10 Sqmm to 3/3.5x300 Sqmm) obtained from taking out serviceable portion complete all as specified and directed by Engr in Charge (Straight through joints and all associated earth work like excavation/returning filling / removal of excavated material and sand filling will be measured and paid separately under respective item of this schedule)

100

-

-

... More
Supply and laying of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 35 Sqmm 3.5 Core complete all as specified and as directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.

400

-

-

... More
Supply and laying of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 70 Sqmm 3.5 Core complete all as specified and as directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.

150

-

-

... More
Supply and laying of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 95 Sqmm 3.5 Core complete all as specified and as directed. Note:-Excavation, earthwork, will be measured and paid separately under respective items of this Schedule.

50

-

-

... More
Supply and fix in repair 2.5 Sqmm three core PVC insulated, unsheathed multistranded copper conductor flexible cable 1100 volts grade from junction box to street light fitting complete all as specified and directed by Engr in Charge.

200

-

-

... More
Material & Labour for opening the existing any size of cable connections from existing junction boxes of street light poles, post top lanterns and building security lights and refixing the same with newly fitted lugs of appropriate size 10, 16, 25, 35, 50, 70 and 95 as the case may be, by opening the existing loop of cable in the roots of street light pole and making the connections new by peeling the insulation with strapper, making proper connections of cable in bus bar of junction box by fixing the new nut bolts/studs and making flexible wire connection in MCB, MCB should be fixed properly also the junction box covers should be closed in proper manner and fixing the junction boxes on the clamp on the pole by bolts complete all as specifeid and directed by Eng-In-Charge Note:- Necessary excavation work for opening the loop and return filling of the excavated material, lugs of appropriate sizes, Nut bolts and tape roll box and other associated works will be the part of this Job and no additional cost will be paid to the contractor, Cost of MCB, New Junction boxes, clamps, if fitted newly will be paid under respective item of this schedule.

30

-

-

... More
Material & Labour for opening the existing any size of cable connections from existing junction boxes of street light poles, post top lanterns and building security lights and making the connections new by peeling the insulation with strapper, making proper connections of cable with newly fitted lugs in bus bar of junction box by fixing the new Nut bolts/studs and making flexible wire connection in MCB, MCB should be fixed properly also the junction box covers should be closed in proper manner and fixing the junction boxes on the clamp on the pole by bolts including checking of electric connection of LED street light on pole complete all as specifeid and directed by Eng-In-Charge Note:- Necessary lugs of appropriate sizes, Nut bolts and tape roll box and other associated works will be the part of this Job and no additional cost will be paid to the contractor, Cost of MCB, New Junction boxes, clamps, if fitted newly will be paid under respective item of this schedule.

150

-

-

... More
Material & Labour for load balacing at different control panels of street lights at different locations of HQ SWAC Chiloda by proper R,Y, B phase sequencing of the street light fittings so that the load in each phase will be equal and unbalace of load in any of the phase be sorted out. the test report before and after balancing will be submitted by the contractor complete all as specified and directed by Eng-In-Charge.

4

-

-

... More
Supply only new MS clamps of size 40 x 5 mm in cros sectional area and upto 500 mm in length suitable for fixing the PVC Junction boxes to the street light poles and boundary walls as the case may be, including making necessary holes and nuts/bolts required for fixing the junction box to the poles either steel tubular or PCC Pole or at the boundary wall for post top lights complete all as specified and directed by Eng-In-Charge.

15

-

-

... More
Taking down of old GI Pipe of any size and Supply and fixing on street light steel tubular Poles /PCC Poles /Walls galvanished iron light grade pipe upto 25 mm dia with all fittings for protection of cables hangig from the street lights to the junction boxes complete all as specified and directed by Eng-In-Charge

15

-

-

... More
Material & Labour for preparation of old painted surface of steel tubular pole (9/11 meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one coat of synthetic enamel paint and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed by Engr-in-Charge.

150

-

-

... More
Material & Labour for preparation of old painted surface of LT RCC pole (up to 6.10 metre height above coping), applying two coat cement base paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one coat of synthetic enamel paint and painting the existing MS clamp with one coat aluminum paint complete all as specified and directed

150

-

-

... More
Supply and paste fluorescent type reflective tape of superior quality width 450 mm (three strips, each 150 mm wide and 600 mm long of colour white, sky blue, white), paste on steel tubular pole on outer circumferences including removing old tape completed all as specified and directed.

10

-

-

... More
Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in sky blue colour background of 80 mm hight around the radius of pole completed all as specified and directed by Engr in charge.

200

-

-

... More
Supply and fix in repair to timer switch Digital type 24 hours with 15 min and 30 min, 16/100 Amp contact rating 230 volts AC 50 Hzs suitable for street lights and completed all as specified and directed by Engr in charge.

6

-

-

... More
Supply and fixing in repair 3 pole power contactor type ML AC 3 rating upto 100 Amps Aux Contactors 2NO+2NC complete all as specified and directed by Engr in Charge.

4

-

-

... More
Supply only MCB’s single pole with neutral, 6 to 32 Amps, 230 volts complete all as specifed and directed by Engr-in- charge.

10

-

-

... More
S&F in repair MCB’s TPN, 63 Amps, 415 volts , fixed in existing PVC box including connecting complete all as specified and directed.

8

-

-

... More
Supply only PVC box of outside size 350mm x 250mm x 150mm and inside size 300mm x 200mm x 105 mm including 4 Nos of bus bar strip of aluminium of size 25x4 mm suitable for 440 volts of suitable amps rating complete all as specified and directed.

50

-

-

... More
Supply and fix in repair LED Bulb 15 watt complete all as specified and directed by Engr in charge.

50

-

-

... More
Supply and fix in repair LED Bulb 09 watt complete all as specified and directed by Engr in charge.

30

-

-

... More
Supply & fix in repair LED post top lanterns of 40 Watt (cool white / warm white) rated power and rated CCT 3000k, IP65 aesthatically designed spun Al spigot for mounting LED Driver and spun aluminium canopy which is painted white inside. Epoxy powder coated matt black finish after phosphochromate treatment, weather proof construction having robust design delivers to meet the landscaping needs , Luminaire type, to be fixed over galvanised pole of daimeter upto 50 mm, complete all as specified and directed.

4

-

-

... More
Supply & fix in repair LED post top lanterns (Tenco type) of 45 Watt (cool white / warm white) rated power and rated CCT 3000k, IP65 aesthatically designed spun Al spigot for mounting LED Driver and spun aluminium canopy which is painted white inside. Epoxy powder coated matt black finish after phosphochromate treatment, weather proof construction having robust design delivers to meet the landscaping needs , Luminaire type, to be fixed over galvanised pole of daimeter upto 50 mm, complete all as specified and directed.

8

-

-

... More
Supply & fix in repair LED post top lanterns of 25/30 Watt (cool white / warm white) rated power and rated CCT 3000K, IP65 aesthatically designed spun Al spigot for mounting LED Driver and spun aluminium canopy which is painted white inside. Epoxy powder coated matt black finish after phosphochromate treatment, weather proof construction having robust design delivers to meet the landscaping needs , Luminaire type,Opaline Model No. BLPTSP 25 W NW LED Make- Oreint,Bajaj,C&S or equivalent fixed over galvanised pole of daimeter upto 50mm,complete all as specified and directed.

6

-

-

... More
Supply and fix in repair 150 Watt LED flood light (cool white / warm white) with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection, Efficiency 110Lm/w, 5700 K fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

8

-

-

... More
Supply and fix in repair 100 Watt LED flood light (Cool white / warm) with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection, Efficiency 110Lm/w, 5700 K fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

8

-

-

... More
Supply and fix in repair 100 Watt LED flood light multi colour with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

4

-

-

... More
Supply and fix in repair 50 Watt LED flood light multi colour/cool white /warm with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

8

-

-

... More
Supply and fix in repair 30 Watt LED flood light multi colour with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purposelighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

10

-

-

... More
S&F in repair 120 Watt LED street light luminarie new generation energy saving & environmental friendly long life versatile pressure die -cast aluminium IP66 road way luminarie with high power LED as light source and electronic driver, Secondary optical lens superior light distribution, Efficeincy 110 Lm/W, 5700 K, minimum pole dia 50 mm fixed on existing GI bracket with electric connections with suitable cable complete all as specified and directed by Engr-in-charge.

22

-

-

... More
All as per item No 44 above here in before but 90 watt complete all as specified and directed by Engr-in-charge.

58

-

-

... More
All as per item No 44 above here in before but 70/72 watt complete all as specified and directed by Engr-in-charge.

30

-

-

... More
All as per item No 44 above here in before but 60 watt minimum pole dia 40 mm complete all as specified and directed by Engr-in-charge.

15

-

-

... More
All as per item No 44 above here in before but 30 watt minimum pole dia 40 mm complete all as specified and directed by Engr-in-charge.

20

-

-

... More
S&F in repair square shaped Decorative LED Bollard light with polycarbonate diffuser, IP 65 of 9 watt with all accessories prewired fixed with PCC with nut/Bolt on exising Location complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Supply and fix in repair LED BULK head light 10 watt Environmentaly friendly, ultra moden, energy mounted, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of hight brightness LEDs complete all as specified and directed by Engr-in-Charge.

10

-

-

... More
S&F in repair Decorative (Bamboo/cone type) LED Bollard light with opel diffuser & IP 65 Protection of 9 watt with all accessories prewired fixed with PCC with nut/Bolt on exising Location complete all as specified and directed by Engr-in-charge.

6

-

-

... More
S&F in repair bush and spike LED light luminaire 1x12/10 W (cool white / warm white) having IP-65 protection, with minimum system efficency 85% made of pressure die cast aluminium housing toughened glass in the front and peanut lens for batwing light distribution with excellent thermal management. The filling should have rated CCT 5000K complete with all accessories complete all as specified and directed by Engineer in Charge.

4

-

-

... More
S&F in repair LED 12 V, 3X3W colourful water proof underwater submersible Fountain lights in RGB Combination of colours with Automatic Controller System of 9 W complete all as specified and directed by E-in- Charge.

20

-

-

... More
S&F in repair SMPS (Rain proof LED Power supply) input supply AC 190 to 260 volt and out put voltage 12 Volt DC + 5% Out put power 500 watt including taking down complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
S&F in repairs wire mesh net suitable for bollard light fitting of size 0.4m x 0.4m x 0.65m and all the four corner and top bottom angle iron framing of size 15mm x 15mm x 3mm and wire mesh net wire size 1.4mm dia and wire mess square gap 20mm with four no ring of size 10mm dia and thickness 3.0mm and made 5.0mm hole for inserting the stud size 5.0cm long and 4.0mm thick with suitable size bolt also welded in the bottom outer side for holding the casing including PCC (1:2:4) of 20mm aggregate of size with one coat of red oxide primer and one coat blue colour paint complete all as specified and as directed.

6

-

-

... More
M & L for repairing the Existing LED bollard light fitting for any type and capacity, taking down the unserviceable LED bollard light and repairing/replacing the unserviceable parts like drivers, surge protection, internal wiring including pcc foundation etc and refitting the same with all connection after making serviceable complete all as specified and directed.

10

-

-

... More
M & L for repairing the Existing LED post top lanterns for any type and capacity, taking down the unserviceable LED post top lanterns and repairing/replacing the unserviceable parts like drivers, surge protection, internal wiring etc and refitting the same with all connection after making serviceable complete all as specified and directed.

8

-

-

... More
Material & Labour for earthing complete in repairs with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to GI strip of size 32x6 by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 40 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit with RCC pit cover charcoal salt, funnel complete all as shown in the electrical plate No 3 of SSR part – I and tested on completion including taking down complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fix in repair Isolator 4 pole 63 Amps 415 volts 50 Hz including taking down complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Supply and fix in repair Isolator 4 pole 100 Amps 415 volts 50 Hz including taking down complete all as specified and directed by Engr-in-Charge.

2

-

-

... More
Lowering of high mast light assembly from 12 to 16 mtr high mast and refixing the complete assembly on 12 to 16 mtr top after checking replacement of unserviceable parts and components as required and make the light fittings operational to give rated illumination incl cleaning the acrylic/glass cover and refixing the same after repair/replacement of spare components complete with necessary electrical connection with two single core 2.5 Sqmm PVC sheathed multistranded copper conductor of required length complete all as specified and as directed. Note :- 1. Spare parts/components shall be measured and paid separately under respective item of sch 'A' . Note:- 2. The greasing of pully, roller, bearing and gear including refixing rope clamp, adjustment of lock, lever etc deemed to be included in the item rate.

10

-

-

... More
Supply and fix in repair 200 Watt LED flood light with pressure die- cast aluminium housing, complete with all accessories, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purpose lighting W Turo Floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 Protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

6

-

-

... More
Taking down carefully existing unserviceable LED Flood light any type and any watt from the pole and existing location to carry the necessary repair like electronic driver, LED, surge protection and rewiring the same complete and fixed to existing location including necessary electric connections complete all as specified and directed.

10

-

-

... More
Supply and fixing in repair trailing cable 4 Sqmm, 5 core copper conductor EPR insulated PCP sheathed cable having current carrying capacity 30 Amp complete all as directed by Engr-in-Charge.

30

-

-

... More
Supply and fixing in repair trailing cable connector and terminal box suitable for 16/12 Mtr high mast.

2

-

-

... More
Supply and fix in repair high mast 3 phase, integral motor 2 HP, 415 volt with one No isolator 4 pole, 63 Amp complete all as specified and directed by Engr-in-Charge.

6

-

-

... More
Taking down carefully existing unserviceable LED Street light any type and any watt from the pole and existing location to carry the necessary repair like electronic driver, LED, surge protection and rewiring the same complete and fixed to existing GI pipe bracket on pole including necessary electric connections complete all as specified and directed. Note: The new electronic driver, LED, surge protection shall be measured and paid separately as supply only under relevant items.

75

-

-

... More
Supply only electronic driver suitable for LED street light fitting of 25 to 120 watt complete all as specified and directed.

35

-

-

... More
Supply only surge protection suitable for LED street light fitting of 25 to 120 watt complete all as specified and directed.

16

-

-

... More
Supply only LED suitable for LED street light fitting of 25 to 120 watt complete all as specified and directed.

15

-

-

... More
S&F in repair street light bracket made out of 40 mm bore GI tubing medium grade 1.20 Mtr long bend to required shape as in bracket for street light fittings fixed with two pair or MS flat iron 40mm x 5mm size and 30cm long clamp of required shape with bolts nuts and washers suitable for steel tubular pole complete all as specified and directed by Engr-in Charge.

15

-

-

... More
Supply and fixing in repair street light bracket made out of 40 mm light grade GI tubing minimum 1.2 mtr long with suitable adapter to suit the opening of street light on one end alongwith integrated fabricated adapter round cup type with 4 Nos studs on outer side to fix the bracket on top of existing steel tubular pole two way,with necessary MS clamps with one coat of red oxide and two coats of aluminium paint upon fabricated adapter including nut, bolt, washers including taking down complete all as specified and directed by engineer –in- charge.

10

-

-

... More
Supply and fix in repair lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fitting complete all as specified and directed by Engr-in-Charge

40

-

-

... More
Supply and connecting in repair of battery 12 volt 42 AH, Sealed maintenance free rechargeable with battery terminals and copper lead for +ve and -ve ends with complete fixing and testing. Note : For items No 59 to 127 Contractor will provide suitable T&P, electrician and helper for routine complaints and rectified with in 48 Hrs otherwise recovery will be made Rs 500 per complaint per day.

10

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.