Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Sep 2024
Closing Date7 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 54,900Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671303_1Bid Award Id
ViewTender No
GE(A)/GNR/TOKEN/54 of 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for PCC Type B1 1:2:4 (20 mm graded aggregate) cement concrete in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
5.4
-
-
M&L steel work as in tubular truess, pulin rafter columns etc including welding, butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and directed by Engineer-in-Charge.
2117.5
-
-
M&L preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
70.2
-
-
M&L preparation of new steel surfaces of any description over 10 cm width or girth and applying ONEcoats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
3.77
-
-
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strenth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping scews complete all as specified and directed by Engineer-in-Charge.
132
-
-
M&L for plates (plain or chequred) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-290 Gde E-165 etc complete all as specified and directed by Engineer-in-Charge.
1281.12
-
-
Removal of excavated material (soil) to a distance n.exc 50m and depositing whre directed at a level n.exc 1.5m above or below the starting point complete all as specified and directed by Engineer-in-Charge.
9.6
-
-
M&L for hardcore of broken stone or boulders, gauge not exc 63mm, deposited spread and leveled in layers not exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
19.8
-
-
M&L for 100mm thick PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, surface finished fair and even complete all as specified and directed.
132
-
-
Providing and laying at or near ground level factory made stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required complete all as specified and directed by Engineer-in-Charge.
1.49
-
-
M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength thickness & size/shape made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compated bed of coarse sand, compacting and proper embediding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern finishing and sweeping extra sand complete all as specified and directed by Engineer-in-Charge.
132
-
-
Taking down carefully u/s copper /aluminium point wiring (light, fan ,socket or power point ) complete,after removing wall panelling without any damage, including fixture and fittings such as switches, ceiling roses, pendants, regulators, socket, light fitting etc. removing materials to store for keeping in safe custody after rewiring refixing of wall panelling. and making good disribution surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-charge.
474
-
-
Taking down Ceiling fan cable end, dismantling blades and removing fan & blades and deposit to E/M store all as specified and as directed
30
-
-
Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
-
-
-
One light/Call bell point controlled by one, one way switch
174
-
-
One fan/Exhaust point controlled by one, one way switch
40
-
-
One 3 pin 6 Amps socket outlet on same board
100
-
-
One 3 pin 6 Amps socket outlet on independent board .
80
-
-
M&L for Point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules all as specified.
40
-
-
M&L for Point wiring complete with 4Sqmm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 4Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules all as specified.
40
-
-
Supply & fix modular switch 1 way, 6 Amps, 1 module (ISI marked).complete all as specified and as directed.
Make : Legrand / Anchor (Roma)/ L&T
394
-
-
Supply & fix modular switch 1 way, 16 Amps, 1 module (ISI marked).complete all as specified and as directed.
40
-
-
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
180
-
-
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
40
-
-
Supply & fix modular fan regulator, 120 watt, 2 moduler (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
20
-
-
Supply & fix ceiling rose, PVC/ polycarbonate,isolated body three terminals, complete all as specified and as directed.
334
-
-
Supply & Fix Buzzer, Ding dong, AC 230Volts single pole all as specified and directed by Engineer-in-charge
4
-
-
Supply & Fix Modular Bell push 6A 1 module all as specified and directed by Engineer-in-chrage
4
-
-
M & L in replacement sub-main wiring with 2 single core 6 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC casing and capping ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 6.0 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire drawn through and connected to main switch/ DB and testing on completion.
Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length.
165
-
-
S&F, in repairs, LED light fitting, 1x20W, 220 V AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
80
-
-
S&F in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and led lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
40
-
-
Sheet metal enclosure (factory made) double door for distribution board (when MCB's are to be used) Single pole neutral 240 V, 12 ways with 200 Amp rated busbar connectin with suitable size of thimbles.
2
-
-
S &F fix in repair Distribution Board SPN 8 way, 240 volts, factory made powder coated, double door with neutral and earth link, suitable for fixing MCB,s complete including connecting all as specified and directed.
4
-
-
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32Amp current carrying capacity in the MCB DB complete with connection testing and commissioning.
6
-
-
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning.
44
-
-
Supply & Fix Cable trays 150mm Wide 50mm Depth of 16 gauge perforated sheet coating including fastner or shaddle work all as specified and directed.
240
-
-
Supply & Fix Cable trays 100mm wide 50mm depth of 16 guage including fastner or shaddle work all as specified and directed.
185
-
-
Supply & Fix Co-axial TV socket, One Module Make Legrand Cat No 5748 51 or equivalent
20
-
-
Supply & Fix double RJ-11 telephone socket (Jack type) with shutter, One Module Make Legrand Cat No 5734 27 or equivalent
20
-
-
Supply& Fix rigid non metallic 25mm dia PVC conduit exclusive of boxes (Junction/terminal) but inclusive of all Tee, bends, elbow reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. all as specified and as directed
80
-
-
Supply & Fix junction boxes (1 to 4 way) with cover plates and accessories all as directed
12
-
-
Cutting chases, pinning in, making good to facings where required of brick/stone wall and painting in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth
77
-
-
M/L for Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode and 4mm dia GI wire as earthing lead.burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point all as specified or directed and testing
4
-
-
S & F in repair Distribution Board Power line VTPN , 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, including for 4 pole MCCB 63 Amps for incoming supply and incl 12 Nos single pole MCBs 6 to 32 Amp for out going supply complete all as specified and directed.
5
-
-
S&F, in repairs, wall/surface mounted, LED engagement light with green and red light and connecting up complete with PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed as per make approved by GE
14
-
-
S&F , in repair 1.5 sqmm 3 core pvc insulated sheathed flexible cable length sheathed flexible cable all as directed by engineer in charge
180
-
-
S&F, modular fan step type regulator, 120W, 2 module including suitable outer cover complete all as specified and directed.
30
-
-
Supply & Fix in repair decorative wall light fittings compatable for LED Bulb B22 base upto 9W, toughned glass with secondary optics including taking out old unsv fitting of any type complete all specified and directed.
20
-
-
S&F PVC body exhaust fan 230 volt 50 HZ 200 mm sweep with 3 core flexible cable complete all specified and directed.
10
-
-
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size all as specified and directed .
16
-
-
Supply, installation, commissoning and testing, in repair, LT Feeder Pillar Panel (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, CPRI approved, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.5 mtr in ground and 0.2 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 160 amps rating of 04 strip - 01 No (ii) MCCB, thermal and megnatic setting, 4 pole, AC, 415volts, 100 Amp rating, 25 KA rupturing capacity - 01 No (iii) Digital type voltmenter 0-500 V with selector switches - 01 No (iv)Panel mounted multifunction meter suitable to oprate on and incl CT in accuracy class 1.0, suitable 3 Phase CT network CT primary programmable, three line baklit display of phase to phase rating Phase to neutral voltage current active power KW ,KVAR and KVA ,PF Frequancy. (v) Indicatiing lamp Neon type for R-Y-B - 3 Nos (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 3 pole, AC, 415volts, 63 Amp rating, 16 KA rupturing capacity - 06Nos.(ii) Cable Connection through Straight Plugs 63 A, 415 Volt - 06 Nos Cat No -058705 Tempra Pro IP -67 and Panel Mounting Socket 63 Amp, 415 Volt - 06 Nos Cat No -058725 Tempra Pro IP -67 Make of Sockets & Plugs -Legrand /Schneider/Siemens , Make of MCCB - Legrand /Schneider/Siemens
2
-
-
Supply, installation, commissioning and testing, in repair, feeder pillar board, LT (415 Volts, 50 Hz , 3-phase, 4 wire supply),CPRI approved, plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.5 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:- (a) Incoming supply:- (i) Aluminium bus bar chamber 200 amps rating of 04 strip - 01 No (ii) MCCB, 4 pole, AC, 415volts, 200 Amp rating, 25 KA rupturing capacity - 01 No (iii) Multifunction meter showing PF, V, I, Hz, Etc (v) Indicating lamp Neon type for R-Y-B - 3 Nos (b) Outgoing supply:- (i) MCCB, 4 pole, AC, 415volts, 63 Amp rating, 16 KA rupturing capacity - 10 Nos (ii) Cable Connection through Straight Plugs 63 A, 415 Volt - 10 Nos Cat No -058705 Tempra Pro IP -65 and Panel Mounting Socket 63 Amp, 415 Volt - 10 Nos Cat No -058725 Tempra Pro IP -65 Make of Sockets & Plugs -Legrand /Schneider/Siemens , Make of MCCB - Legrand /Schneider/Siemens
1
-
-