Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Eprocure
Opening Date19 Nov 2024
Closing Date10 Dec 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S & F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB 20amp 240V all as specified and directed.

9

-

-

... More
M&L in sub main wiring with 2 single core PVC insulated unsheathed cable, 1100v grade with FRLS PVC 4sq mm copper cable multi stranded conductor drawn through and including ISI marked PVC conduit 25 mm dia complete, fixed on walls/ceilings with PVC saddles as per IS including of 4 sqmm dia FRLS PVC Copper cable green colour as earth wire connected to earth all as specified and directed by Engineer-in-Charge.

185

-

-

... More
S&F of flameproof, weather proof LED tube light fitting, type FLP-WP with LED 1 x 16 / 20 W including integral reflector made of aluminum alloy LM79 , with electronic driver, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed.

8

-

-

... More
Supply and fixing of stove enamelled black MS conduit 20mm dia ISI marked on ceiling or recessed as required & repairing & making good the same disturbed surfaces all as specified and directed

70

-

-

... More
Supply and fixing PVC insulated, PVC sheathed single core multistranded copper conductor cable of size 1.5 Sqmm FRLS all as specified and directed by engineer-in-Charge.

50

-

-

... More
Supply and fix ON/OFF Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V.

20

-

-

... More
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and removal surplus matrerils to distence n exc 50 mtr amd ,making good surface complete

10

-

-

... More
M&L Cement concrete 1:4:8Type D2 (using 40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified.

0.36

-

-

... More
M&L Cement concrete 1:2:4Type B-1 (using 20mm graded aggregate) as in foundation, filling and mass concrete complete all as specified.

1.8

-

-

... More
S&F Hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire mesh etc, flat iron fillets(for securing wire mesh etc) including all necessary drilling bolting or riveting etc, and similar work conforming to Fe -290 Gde E-165

210

-

-

... More
S&F Mild steel screw bolts(machine made)5 to 10mm dia of shank with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or squarae nut, exc 5cm but n.exc 10 long.

1.5

-

-

... More
S & F for misl steel round bar 10 dia and over as in strenghtening bars for chain link fencing conforming to Fe-290 GdeE-165 complete all s specified and directed

56

-

-

... More
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provission of binding wire.

65

-

-

... More
Supply only chain link MS galvanised fencing conforming to IS 2721:2003 including line wires of 4mm dia straining bolts etc including provn of binding wire complete all as specified and directed.

275

-

-

... More
S&F Galvansed 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia bars at 75mm spacing and straining and fixing to any typeof standard rails straining bolts including securing or typing at crossing with and provn of galvanised mild steel wire staples or steel pins etc as directed (each line of wire to be measured) complete all as specified and directed.

2

-

-

... More
M&L for preparation of new iron surfaces ove 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome complete all as specified and directed.

7

-

-

... More
Surface excavataion n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified.

270

-

-

... More
Removing (soil) excavated materials n exc 50m and depositing where directed at a level n exc 1.5m above the sarting point complete all as specified.

80.5

-

-

... More
M&L Hardcore(broken stone of boulder)of guage n exc 63mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified.

27

-

-

... More
M&L 100mm thick Cement concrete type C-2, 1:3:6 (using 40mm graded aggregate) as in sub base complete all as specified.

270

-

-

... More
M&L for 80mm thick Machine pressed precast concrete interlocking paver block any shape and size with grey cement and no pigment confirming to IS-15658-2006 of M-40 Grade complete all as specified.

270

-

-

... More
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified.

5.4

-

-

... More
M& L for Providing, cement concrete type 1:2:4, using 20mm grade aggregate in in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified.

2

-

-

... More
S & F for false ceiling of Non asbestos fiber cemnet building boards, manufactured from homogeneous mixture of cement , quartz and celluose and cured with high pressure steam using aouto clacving process confriming to IS 14862, of size 600mmx600mmx 4mm thick fixed over and including anodised aluminiuum power coated (minimum tick of power coating 50 microm) snap grid frame work of T section (main & cross member) of size 25mmx25mmx1.5 mm thick in square pattern of grid size 600mmx600mm (i) The aluminium fram work willl supported on side wall with used of aluminium L section of size 25 mmx25mmx1.5mm angle etc. Snap grid shall be supported with hanger of 4mm dia, galvanised iron wire adjusting level fixed to roof slab/ truss etc by means of ceilling cleats made out of galvanised iron flat o sixe 40x3 mm size 60mm long and expension hold fastenets 12.5 mm dia 40 mm long complete all as specifed and direfcted.

105

-

-

... More
M & L for applying two coat of oil bound distemper by spray machine incl prepration of old surface by complete removal existing treatment on wall through electrical oprated of grinder etc. Incl necessary minor repair of wall by putty complete all as specified and directed.

255

-

-

... More
Supply and fix Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector

3

-

-

... More
Supply and fix Detectors Complying with and type certified to EN-45 Addressable type multisensor detector with heat and smoke combination with base with self built intelligence as per IS: 11360

4

-

-

... More
Supply and fix Addressable manual call point resettable type

1

-

-

... More
Point wiring with 2.5 sqmm(22/.3mm) PVC insulated and unsheathed FRLS single core multistranded copper conductor for one light/fan/bell point in and including PVC rigid non metallic concealed conduit 19/20 mm dia, medium duty, ISI Marked to be terminated in modular metal box , modular fittings etc including 2.5 sqmm (22/.3 mm ) PVC insulated and unsheathed FRLS single core multistranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified.

1

-

-

... More
Supply and fixing modular Socket 6A/16A - 2/3 pin combined 2 module all as specified & directed.

1

-

-

... More
Supply and fixing Modular switch 1 way 16A, 1 module all as specified & directed.

1

-

-

... More
Supply and fixing Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB 1000 mtr range

1

-

-

... More
S&F of PVC insulated, 2 core 2.5 Sqmm round sheathed copper conductor(flexible) industrial cable fire retardant all as specified and directed.

25

-

-

... More
Supply ,fixing, testing and commisioning in replacement of fire alarm contol panel NFS 320 Standalone 2 Loop NFS2-*Considered Standalone 2 Loop NFS2- 3030D System to be fixed at same place including disconnecting and reconnecting all asessories connected to existing panel all as specified and directed by Engineer-in-charge Make NOTIFIER or equivalent as approved by the GE.

2

-

-

... More
Supply ,fixing, testing and commisioning in replacement of Network communication module all as specified and directed by Engineer-in charge Make : NOTIFIER Model No: NCM -W or equivalent as approved by the GE.

2

-

-

... More
Supply ,fixing, testing and commisioning in replacement of Network card of fire alarm monitoring PC

1

-

-

... More
S&F of Batteries DC, 12V, 7 AH, lead acid duly initial charged complete including taking down old unserviceable battery. Make: Exide/ Star Gold or equivalent as approved by the GE.

6

-

-

... More
Supply, installation and commissioning and testing in replacement of Addressable Smoke detector with base with Binary coded address setting. Dual Led's for 360 visibilty. Sleek low-profile housing design. Regular 100mm base. IP rating: Ip-42 and including taking down old unserviceable. Make: Ravel/HONEYWELL/CEASEFIRE INDUSTRIES PVT LTD or equivalent as approved by the GE.

16

-

-

... More
S&F of Batteries DC, 12V, 26 AH, lead acid duly initial charged complete including taking down old unserviceable battery. Make: Exide/ Star Gold

2

-

-

... More
Supply and fixing in replacment of XLPE armoured Copper cable of size 1.5sqmm 2 core all as specified and directed by engineer-in-Charge

200

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, complete all as specified and directed.

96

-

-

... More
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.

57

-

-

... More
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.

33

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified and directed by Engineer in charge

2573

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core

430

-

-

... More
S & F Tubes, 'light grade'galvanised 50mm ,with all fitting and fixed complete to walls and ceilings or laid in floors

45

-

-

... More
S & F Tubes, 'Medium grade' galvanised 50mm dia 8 M long for fixing of Flood light 100 W qty -01 nos, including excavation ,PCC foundation, SMC Box250mmx250mmx 105mm with clamps,nuts bolts , Aluminum bus bar ,MCB SP 20A -01 Nos complete all as specified and directed

8

-

-

... More
Supply and fixing GI Pipe medium grade 40 mm dia 2m long , welded with bracket for fixing two nos of LED flood light including PCC foundation, Sheet Moulding Compount (SMC) junction box of size 155x155x100mm, having mild steel clamp ,nuts and bolts, MCB SP20A-01 nos complete all as specified and directed by Engineer in Charge

4

-

-

... More
Supply and fixing LED Flood light fittings 100W IP 66 protection complete all as specified and directed by Engineer in charge

8

-

-

... More
Supply and fixing LED Flood light fittings 150W IP 66 protection complete all as specified and directed by Engineer in charge

10

-

-

... More
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers

4

-

-

... More
Meterial and labor for making holes in wall for fixing of Exhaust fan of size 300mm sweep complete all as specified and directed

3

-

-

... More
Point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in and including 19mm dia nonmetallic rigid PVC conduit medium grade including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using the existing pressed steel terminal box, provision of 3 mm thick plastic laminated sheet cover for mounting of switches sockets fan regulators etc. & making good to disturbed surface area for the one light/ fan point controlled by one single pole, one way switch complete all as specified. NOTE: (a).The quoted rates includes the cutting chasis for conduit and sunken boxes.

4

-

-

... More
Switch piano, flush type, single pole, one way, 5 Amp, 230volts complete all as specified.

4

-

-

... More
Supply and lay PVC insulated 3 core copper conductor cable of size 1.5 Sqmm sheathed 1100 volts conforming to IS 694 fron junction box to Flood light fitting all as specified and directed

48

-

-

... More
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core

105

-

-

... More
Supply and fixing 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 26 KA. In existing LT Panel & Load line DB

2

-

-

... More
Supply and fixing vertical load line DB 4 way double door type fitted with MCCB ,Bus bar links ,blanking plates complete all as specified and directed by Engineer in charge

1

-

-

... More
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning

12

-

-

... More
Supply and laying Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground

28

-

-

... More
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw

2

-

-

... More
Supply and fixing Sheet Moulding Compount (SMC) junction box of size 155x155x100mm mild steel clamp ,nuts and bolts complete all as specified and directed by Engineer in charge

2

-

-

... More
M & L for chemical earthing using mixture of Magnesium sulphate(MgSO4)100kg,common Salat 200 Kg and charcol 300 Kg complete with copper earthing plate 90Cmx60Cmx5mm complete burried on ground vertically to a depth not less than 3.5 M below the ground level with top edge of the plate at a depth not less than 2.5 meter below ground level and mixture shuld be filled 15 cm above top edge of earth plate to active result not less than one ohm resistance ,including copper strip 32x6mm size by means of brass bolts,nuts,check nuts and washeres and brazing of copper earth strip protected by galvonised steel pipe 40mm bore light grade connected to main switch board or any othe electrical switch board or any othe electrical equipment all as shown in electrcal plate no 3 of SSR part I and including necessory excavation ,earth work in any type of soil and earth pit should be refill with black cotten /clay soil ,20mm medium grade water GI pipe for watering ,funnel with wire mesh ,PCC (1:2:4)type B1 reinforced with XPM of weight not less than 4 kg/Sqm and MS frame etc all as specified and directed by Engineer in charge Note : (i)Earth result after installation completely should be less than 1 Ohm (ii)Quoted rates shall be deemed to include for earth strip with protection pipe of 7.5 M length. (iii) Black soil to be arranged by the conrteractor for mixing charcol,Crystal salt,Magnesium sulphate & Vegitable oil and also for filling balance portion of pit in layer is deemed to be included in quoted rate (iii) Tools and plants to be required for making depth upto 4 Mtr is to be arranged by the contractor,charges for the same is included in the quoted rate

2

-

-

... More
Supply & installation of Air Cooled Inverter based split AC unit with cooling functions and suitable to operate at ambient conditions of (-10 to 46 Deg C in cooling Mode). Air conditioner will have following conditions:- (i) Refrigerent - R 410a (ii) EER - min 5 w/w (5 star rating) (iii) Tonnage - 2 (iv) Indoor Noise Level - Not more than 48 Db (v) Filter - (a) Must have PM 2.5 µ Filter (b) Electrostatic dust filter (c) Oxidizer dust filter (vi) Functions of remote : (a) Air directional control (b) Auto Timer (c) Economic sleep mode (d) Auto fan speed (e) Auto swing (f) Temp display (g) Turbo mode All specification will be as per IS-1391 (Part 2) 1992 Room Air Conditioners Make: BlueStar / Hitachi/ O General

8

-

-

... More
Supply and fixing MCB 32 Amp SP C Curve complete all as specified and directed

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.