Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date11 Dec 2024
Closing Date8 Jan 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and fix in repair 1100 volts grade PVC insulated PVC sheathed cable weather proof multisranded/ solid aluminium conductor 3 core 4.0 sqmm from jn box to connector of fitting complete all as specified and as directed.

100

-

-

... More
Supply and fix in repair in existing street light panel and connection with bus bar out going cable with copper wire with MCCBs of the undermentioned sizes complete all as specified and as directed.

-

-

-

... More
MCCB 4 pole 'C' curve 100 Amps, 415 Volts AC, 16 kA

5

-

-

... More
MCCB 4 pole 'C' curve 40-63 Amps, 415 Volts AC, 16 kA

7

-

-

... More
Supply and fix in existing Street light panel and connection with bus bar out going cable with copper wire with power contactors 3 phae, 415 V, 40 Amps, in repair complete all as specified and as directed Make: L&T Model ML-3 SS90721 or its equivalent in Schinder/ ABB / Siemens/ HPL

2

-

-

... More
Supply and fix in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed

30

-

-

... More
Supply and fix in repair/replacement for kiosk box for luminaries, weather proof made out of PVC/HDPE /FRP housing fire retardant, non fusing, shock & rust proof, single piece molded and cover with hinged door, pole mounting type comprising of aluminum TPN bus bar of 20 Amps of minimum size 300x250x150mm, fixed on pole with MS, clamps 30x5mm with necessary nuts, washer including MCB 16 Amps for out going complete all as directed. Note :- Rate of TPN bus bar and MS clamp inclusive in item rate.

30

-

-

... More
Supply and fix in replacemet of High efficiency long life CREE LED chip in modules of following capacity with Ra75 and lumen efficacy of 95 lum/watt or equivalent suitable forsuitable for LED light fitting complete all as specified and directed Make : Philips/Shakti/Bajaj/ Havells/CG/Surya.

-

-

-

... More
100 to 150 Watt fittings

10

-

-

... More
50 to 90 Watt fittings

46

-

-

... More
40 to 45 Watt fittings

15

-

-

... More
Supply and fix in replacement LED street light fitting driver of exisiting make and model of rating 40 Watt complete all as specified and as directed. Make: Bajaj/CG/Philips

40

-

-

... More
Supply and fix in replacement LED street light fitting driver of exisiting make and model of rating 60 W to 90 Watt complete all as specified and as directed. Make: Bajaj/CG/Philips

90

-

-

... More
Supply and fix in replacement LED street light fitting driver of exisiting make and model of rating 100 W to 150 Watt complete all as specified and as directed. Make: Bajaj/CG/Philips

20

-

-

... More
Supply and fix in replacement of LED Post top of 25 Watt Integral pole mounted decorative LED with IP-65 protection complete fixed on existing post, all as specified and directed. Make-Havell's Cat part no-RUBYPT25WLED830SSYMTOPC, or equivalant of Crompton / Philips /BAJAJ)

4

-

-

... More
Material and labour for preparation and painting 04 nos band / strips with blue and white paint alternately all around the HT/LT/street light pole with synthetic enamel paint at a distance of 30 cm and painting both side for numbering with black enamelled paint and writing LT/ PL No on both side of pole with white enamelled paint of complete all as specified and directed .

300

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/ loose soil, for laying of under ground electric cable complete all as specified

81

-

-

... More
Taking out LT UG cables of any size by excavation and earth work in any type of soil, removing bricks or PCC cover of any size complete all as specified and directed. Note:- Excavation, Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separately.

300

-

-

... More
Taking out serviceable unreinforced precast concrete cable covers CLASS LV type I, flat size 250mm x 150mm x 40mm laid transverse to cable complete all as specified and directed.

1875

-

-

... More
Relaying old serviceable under ground LT cable of any size obtained from item 2 above complete all as specified and directed

150

-

-

... More
Supply and lay, jointing and testing in repairs/replacement of LT cable of size 16 Sqmm 4 core XLPE insulated, armoured, heavy duty with multi stranded aluminum conductors, 1100V grade, laid in trenches / ducts / through GI pipe fixed to pole complete all as specified and directed Note:- Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately.

150

-

-

... More
Material and labour for river bed sand used in trenches/ ducts 08 cm under cable and 15 cm above the cable for cushioning/protection to cable and get thick 18cm after hand punning complete all as specified and directed

14.58

-

-

... More
Laying only serviceable un-reinforced precast concrete cable cover class LV, Type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over for cable protection complete all as specified and directed.

563

-

-

... More
Supply & laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over for cable protection.

1313

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed

49

-

-

... More
Removing excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified

32

-

-

... More
Supply, fixing and testing LT cable jointing kit straight through type heat shrinkable suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100 volts grade LT cable of size 3.5/4 core 16 to 50 sqmm and including taking out cable from faulty portion in any situation/position complete all as directed.

4

-

-

... More
Disconnect cable of street light of any core, cutting its end, arrange necessary length from loop, fix neccassary lug in every core, cable connect in kiosk box or in LED street light and makes cable servicable etc complete all as specified and directed.

150

-

-

... More
Taking down the following existing worn out spares of Split type Air conditioners 1.5 Ton / 2.0 Ton capacity; supply and fix in repair new spares of make and model all as specified and as directed:-

-

-

-

... More
Blower Motor Indoor Type Make :- GE/ LG/ BlueStar

5

-

-

... More
Fan Motor Out door Type without blades Make :- GE/ LG/ BlueStar

5

-

-

... More
Fan Blade for outdoor unit

5

-

-

... More
Running Capacitor 50 to 60 MFD (Tibcon/ Baba/ Tipcon)

25

-

-

... More
Air filter for Indoor Unit

8

-

-

... More
Display for Indoor unit of existing Make: LG/ Voltas/ Videocon

10

-

-

... More
Remote control (Hand set only) with Battery of existing Make: LG/ Voltas/ Videocon

2

-

-

... More
LDPE drain water pipe 15 mm bore

40

-

-

... More
Supply and fix PCB Timer electronic switch with sensor suitable for all makes of split 1.5 / 2 Ton AC complete with hand set including taking down unserviceable Electronic PCB from existing unit all as directed. Make: Voltas/Carrier/LG/Hitachi or its equivalent as approved by GE

8

-

-

... More
Material and labour for opening the indoor unit front panel of wall mounted split type 1.5/ 2 Ton AC for cleaning the existing LDPE pipe for any block by blowing the pipe with air and cleaning the bottom water line of indoor unit for arresting leakage of water complete all as specified and as directed.

12

-

-

... More
Taking out unserviceable Rotary type compressor of Split type AC 1.5 ton capacity and re-fixing with new Rotary type compressor sealed unit in position, charging of refrigerant gas R-22 of required quantity, bracing of discharge and suction line and leak testing complete all as specified and as directed. Make: Copeland/ Tecumseh/ Highly

6

-

-

... More
All as per serial item number 30.00 here-in-before but for Split Type AC 2 Ton capacity Make: Copeland/ Tecumseh/ Highly

3

-

-

... More
Material and labour for Top up / Gas charging with refrigerant gas (R-22) for Air conditioner window type / split type of capacity 1.5 / 2 / 5.5 / 11 Ton after vacuuming & leak testing including bracing suction/discharge line and testing complete all as specified and as directed.

100

-

-

... More
Supply and fix in replacement of copper tubing (of dia 1/4" to 1/2" ) suction and liquid line from indoor to out door unit by compressing Ref Gas suitable for split AC of capacity 1.5 TR/ 2.0 TR including insulation on copper tubing complete all as specified and as directed. Each RM included Complete set of suction and discharge line)

40

-

-

... More
Supply and fix in replacement condenser coil made up of copper for split AC 1.5 TR/2.0 TR complete all as specified and as directed.

5

-

-

... More
Taking down existing split type AC from one location and re-fixing the same in another location as directed, including replacement of copper wire require for connecting IDU & ODU, additional copper tube if required, cleaning the IDU and ODU including chemical wash for smooth functioning, complete all as specified & directed.

5

-

-

... More
Material and labour for chemical wash & cleaning of complete indoor/outdoor units of size 1.5/2.0 TR capacity split type air conditioner by means of adding, cleaning solution (HCL) or equivalent solution with water. The cleaning of the condenser and chillier units is done with use of nylon brushers till the scaling is removed.

20

-

-

... More
Material and labour for Top up / gas charging with refrigerant R134A of required quantity for water cooler / water dispencer / Refrigerator / Deep freezer of any make including leak testing, necessary brazing of suction and discharge line and testing complete all as specified and as directed.

8

-

-

... More
Material and labour for cleaning of following size and capacity of Water coolers (40/80 capacity) / Refrigerators(upto 320 Liters) / Deep freezers (300 Ltrs) by including cleaning of storage area with use of bleaching powder and cleaning of condenser coil by means of adding cleaning solution (HCL) or equivalent solution with water. The cleaning of the condenser and chillar units is done with use of nylon brushers till the scaling is removed all as directed by EIC.

4

-

-

... More
Dismantling and taking out following unserviceable compressors for replacement from the existing water cooler / refrigerator / Deep freezer after cutting carefully the suction and discharge line. Refixing the new compressor including first filling of gas and serviceable accessories with brazing the suction and discharge line and leak testing complete all as specified and directed. Makes :Copeland/ Tecumseh/ Highly/Godrej

-

-

-

... More
Compressor hermatically sealed suitable for 40/80 litre capacity water cooler

1

-

-

... More
Compressor hermetically sealed suitable for Refrigerator of 165 to 310 ltr Capacity

1

-

-

... More
Compressor hermetically sealed suitable for any capacity deep freezer.

1

-

-

... More
Supply and fix thermostatic switch in replacement for Water cooler 40/80 liter capacity, refrigerator 165 to 310 Ltr & Deep freezer existing appliances (Make : Danfoss/Indofoss/ Whirlpool/Honeywell).

3

-

-

... More
Material and labour for pump suitable for desert cooler as existing make & model, ISI marked, including taking down/out unserviceable motor& pump all with wiring and as directed

7

-

-

... More
Material and labour for fan motor & fan with blade suitable for desert cooler of any capacity/make including takin down existing fan. Make: AUE/GE motors

7

-

-

... More
Material and labour for opening the AC units by authorized service engineer & taking down any us parts/ accessories ( compressor, blower motor , leak testing, air dryer filter replacement etc) for after disconnecting electric connections and taking out the defective parts for repair/replacement and re-assembling and testing commisioning the packaged AC of single circuit (5.5 TR) after repairs. Re-fixing only serviceable accessories and Re-fixing the ACs to its original position including electric connections and copper tubing and testing and commisioning complete for 5.5 / (2 x 5.5) 11 Ton Capacity Package AC's complete all as specified. Note :- The rate quoted under this item is deemed to include for each job consisting of labour only for replacement of compressor/blower motor etc. of each AC unit. Supply only of the compressor/blower motor shall be measured and paid separately.

2

-

-

... More
Supply only new compressor sealed units sutiable for unit dismantled from above mentioned item , as per existing any make and model, including brazing / welding of suction and discharge line, Including first filling gas and leak testing complete 5.5 Ton Capacity suitable for 5.5/(5.5X2) 11 TR package AC complete all as specified and as directed Make : Tecumseh/ Danfos/ Blue star / Copeland

2

-

-

... More
Supply only blower motor of outdoor unit of any make and model as existing in position for unit dismantled under item No 16 above including other connected accessories of 5.5 Ton/(5.5X2) Ton Capacity package AC. Make :- AUE/GE/Crompton Greaves/Marathon

2

-

-

... More
All as above above mentioned item, but blower motor of indoor unit suitable for 5.5/(5.5X2) Ton Capacity package AC. Make :- AUE/GE/Crompton Greaves/Marathon

2

-

-

... More
Supply and fix in repairs synthetic woven Air filter for indoor unit, make and model as per existing for 5.5 Ton/(5.5X2)11TR Capacity, of existing make complete all as specified and as directed

4

-

-

... More
Supply and fix in repairs remote sensing display unit with remote, PCB card & cord as per existing make and model for 5.5 TR/(5.5X2)11TR Capacities Package Acs of Existing Make all as specified and diected at site Make:- Blue star or equivalent.

2

-

-

... More
Supply and fix in replacement 'V' belt of existing size suitable for in door unit of 5.5/(2x5.5) ton package type AC units complete all as specified.

4

-

-

... More
Supply and fix in replacement contactor 3 Phase suitable for existing 5.5/(5.5X2)11 TR all as specified and need as per site complete all as specified. Make:- L&T/ Siemens / Minilec/Schneider

4

-

-

... More
Supply and fix in replacement single/three phasing preventer suitable for 5.5/(5.5X2) 11 TR AC units. Make:- L&T/ Siemens / C&S / Minilec

2

-

-

... More
Supply and fix in repair LDPE drain water pipe line, 25mm bore, including fittings complete all as directed.

20

-

-

... More
Supply and fix in repair gas charging valve of suction or discharge line suitable for 5.5 Ton / 11 Ton capacity AC units as per existing make & model.

3

-

-

... More
Supply and fix in repair expansion valve suitable for 5.5Ton /(5.5X2) 11 Ton capacity AC units as per existing make & model including cutting, brazing / welding, leak testing complete all as specified and directed Make: Voltas/Bluestar/ Danfoss

2

-

-

... More
Supply and fix in repair Liquid line air dryer with 100% molecular sieves and max working pressure of 500 PSIG suitable for 5.5Ton /(5.5X2) 11 Ton capacity AC units as per existing make & model including cutting, brazing / welding, leak testing complete all as specified and directed Make : Danfoss / Dwelfoss/ Bluestar/ Voltas

2

-

-

... More
Material and labour for carefully opening the AC units, taking down any parts/ accessories (Bearing, Shaft along with blower motor etc) by\ authorized service engineer for repairs after disconnecting electric connections and taking out the defective parts for repair/replacement and re-assembling the A/C after repairs/ replacement of defective parts & Re-fixing serviceable accessories to its original position including and testing complete for 5.5 / (2 x 5.5) 11 Ton Capacity Package AC's complete all as specified & directed. Note :- The rate quoted under this item is deemed to include for each job consisting of labour only for replacement of Bearing set/blower/shaft etc. of each AC unit. Supply only of the bearing set /blower/shaft shall be measured and paid separately.

2

-

-

... More
Supply only bearing set of two suitable for (5.5x2) 11 TR packaged AC blower shaft.

2

-

-

... More
Supply only Blower suitable for (5.5x2) 11 TR packaged AC blower shaft.

1

-

-

... More
Supply only Shaft suitable for (5.5x2) 11 TR packaged AC.

1

-

-

... More
Supply and fix in replacement MCCB 4 pole 16 KA with Fixed type thermal and magnetic setting, of following capacities:- Make :- L&T/Havells/Indo Asian/Schneider

-

-

-

... More
125 Amps

2

-

-

... More
100 Amps

2

-

-

... More
Supply and fix in replacement MCB TPN 63 Amps, 10 KA, 'C' series. Make : L&T/ Indo Asian / Havells/ Schneider/ HPL.

3

-

-

... More
Supply and fix in replacement industrial plug and socket with single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity complete all as specified and as directed.

5

-

-

... More
Supply and fixing/drawing wiring for Circuit / Submain wiring with PVC casing caping of suitable size inclusive of all tees, bends, elbows, reducers bell mouth tube ends and fixing accessories including all fixtures /fittings fixed on wall/ceiling along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed as required of 2 x 6.0 sqmm and 1 x 4.0 sqmm as earth wire Complete all as Specified & directed.

30

-

-

... More
Supply and fix in replacement of indoor unit of 1.5 / 2.0 TR air conditioner complete including all connected items for indoor unit & removing old indoor unit and fixing of new unit with accesories all as per specified and directed.

2

-

-

... More
Material and labour for Top up / Gas charging with refrigerant gas (R-410/R-32) for Air conditioner window type / split type of capacity 1.5 / 2 Ton after vacuuming & leak testing including bracing suction/discharge line and testing complete all as specified and as directed.

25

-

-

... More
Supply and fix in replacement of PCB outdoor unit electronic switch suitable for 1.5 TR split AC Inverter Type of Make Carrier with complete fitting and testing complete all as specified and as directed.

4

-

-

... More
Supply and fix in replacement of PCB Indoor electronic switch suitable for 1.5 TR split AC Inverter Type of Make Carrier with complete fitting and testing complete all as specified and as directed.

4

-

-

... More
Taking out U/S PCB of Indoor/Outdoor and after reapir, re-fix it suitable for 1.5/2 TR split AC Inverter Type of Make any type with complete fitting and testing complete all as specified and as directed.

5

-

-

... More
Supply and fix in replacement Starting Capacitor of 80 to 100 MFD complete all as specified and as directed. Make:- Tibcon/ Kerlton/ Usha as approved by GE.

6

-

-

... More
Taking down carefully copper / aluminium point wiring, (light, fan, socket, power) through teakwood batten, PVC casing and capping, PVC/steel conduits, complete including fixure and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, bell/buzzers etc complete and making good distributed surfaces of walls floors etc , complete all as specified and as directed.

200

-

-

... More
Material and labour for point wiring complete with 1.5 Sqmm PVC insulated and unsheathed cable single core multi stranded copper conductor, 1100 volts grade drawn through and including PVC casing / capping/ concealed, medium grade of any size with all accessories like bends, junction boxes etc including copper earth continuity wire of PVC insulated of size 1.50 Sqmm and connected to common earth dolly with all accessories including sunken type pressed steel terminal boxes 3mm thick hylam/ bakelite sheet, complete as specified for : -

-

-

-

... More
One light point controlled by one switch

90

-

-

... More
One fan point controlled by one switch through regulator

30

-

-

... More
One Exhaust fan point controlled by one switch .

10

-

-

... More
One 3 pin socket out let 5 Amp on independent board

20

-

-

... More
One 3 pin socket out let 5 Amp on same board with other switches

20

-

-

... More
One bell/buzzer point controlled by one push button on same board or independent.

5

-

-

... More
All as per serial item No 71.00 here-in-before but with 2.5 sqmm single core cable for one 3 pin socket outlet 15 Amps on independent switch board including 1.50 Sqmm as earth continuity conductor and connected to common earth dolly complete all as directed and specified.

25

-

-

... More
Supply and fix in replacement switch socket outlet 2 in 1multipurpose 3 pin, 5/15/16 Amps combination and 3 pin 5 Amps controlled by one switch all as specified and directed.

25

-

-

... More
Supply and fix in replacement switch piano flush button SP one way 5/6 Amp all as specified and directed

140

-

-

... More
Supply and fix in replacement socket combination 3 pin 5 / 6 Amp flush type multipurpose all as specified and directed.

40

-

-

... More
Supply and fix in replacement call bell Ding Dong type, AC, 230 volts, single pole controlled by one bell push all as specified and directed.

5

-

-

... More
Supply and fix in replacement for bell push, AC, 230 volts, single pole all as specified.

7

-

-

... More
Supply and fix in replacement ceiling rose three terminal,PVC/Polycarbonate, Isolated body, complete as specified and directed.

90

-

-

... More
Supply and fix in replacement electronic resistance step speed regulator suitable for 1200 mm sweep ceiling fan up to 300 watt all as specified and directed.

25

-

-

... More
All as per serial item No 73.00 here-in-before but modular type

10

-

-

... More
All as per serial item No 74.00 here-in-before but modular type

15

-

-

... More
All as per serial item No 75.00 here-in-before but modular type

25

-

-

... More
Supply and fix in replcament of LED tube light batten of wattage not less than 20 Watt, 2000 Lumen (4 feet long) white / brown colour, fixed to wall/ ceiling along with necessary fixing screws, etc. complete all as specified and as directed.

350

-

-

... More
Supply and fix in replacement of old 2x36 watt tube light fitting in false ceiling with LED Square Recessmounting powder coated white CRCA full glow LED panel Downlight of 36 Watt Warm White fitting with LED lights complete along with necessary connecting cable of PVC insulated 3 core 0.5 sqmm from fitting to ceiling rose/ connector complete all as specified and directed. Make:-Havell's Model No.VENUSNEOHE2X2PLR18-42WLED830MOD OR EQUIVALENT MAKE-CG/Philips/BAJAJ

4

-

-

... More
Material and labour in replacement of earthing complete with galvanised steel earth plate electode 600 x 600 x 6 mm thick buried directly in ground earth pit with adequate quantity of charcoal and dust and common salt , not less than 2.25 mtr deep below ground level connected to & including galvanised earth lead wire 4 mm dia drawn through GI protection pipe of size ordered specified for protection of earthing lead from earth electrode to test point/main DB from mechanical injury or tempering by means of nuts and bolt check nuts and washers of galvanised iron sheet all as shown in electrical plate No 3 of SSR Part - I and connected to earthing test point complete including testing, refilling earth and removal of surplus soil upto 50 mtrs, PCC 1:3:6 type CI chamber precast RCC cover 40 mm thick reinforced with 6 mm dia MS bar 3 Nos both way with handle made out of 6 mm dia MS bar water pipe with wire mesh and connecting testing etc complete all as specified and directed.

4

-

-

... More
Material and labour in replacement for Sub main wiring with two run of 4.0 sqmm single core, PVC insulated but unsheathed multistranded FRLS copper cable 1100 volts conductor drawn through in Concealed Heavy duty PVC conduit with all accessories and 4.0 sqmm PVC insulated but unsheathed multistranded FRLS copper conductor cable as earth continuity wire complete all as specified and directed. Note: Two run of PVC cable with one run of PVC earth wire and one run of PVC conduit shall be measured and paid as one length only.

80

-

-

... More
Material and labour in replacement for Sub main wiring with two run of 10.0 sqmm single core, PVC insulated but unsheathed multistranded FRLS copper cable 1100 volts conductor drawn through in Concealed Heavy duty PVC Casing Caping with all accessories and 10 sqmm PVC insulated but unsheathed multistranded FRLS copper conductor cable as earth continuity wire complete all as specified and directed. Note: Two run of PVC cable with one run of PVC earth wire and one run of PVC conduit shall be measured and paid as one length only.

30

-

-

... More
Supply and fix in replacement Factory made sheet metal enclosure MCB DB (Protection class IP-42) Double door with Acrylic cover, powder coated DB's fitted with 200 Amps Bus bar, neutral link, earth Bar and din Rail complete of following sizes:-

-

-

-

... More
SPN, 4 way, 240 Volts

4

-

-

... More
SPN, 8 way, 240 Volts

4

-

-

... More
SPN, 12 way, 240 Volts

4

-

-

... More
TPN, 4 way, 415 Volts

4

-

-

... More
Supply and fix in replacement the following MCBs of approved make, 'C' curve type & 10 KA breaking capacity, at locations complete all as specified and as directed.

-

-

-

... More
MCB TP 25 to 63 Amps

5

-

-

... More
MCB TP 16 to 32 Amps

5

-

-

... More
SPN 40 to 63 Amps

6

-

-

... More
SPN 32 Amps

9

-

-

... More
SP 5-32A Amps

33

-

-

... More
Supply and fix in repair Air termination, single point copper rod 12 mm dia and 300 mm long complete all as specified

15

-

-

... More
Supply and fix in repair Test point terminal box of size 200x100x100mm made out of 2mm thick hot dip galvanized sheet drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with test point terminal block made out of Gun metal or Phosporous Bronze size 75x75x25 mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screws, etc complete all as specified and as directed.

8

-

-

... More
Supply and fix Copper strip 20 x 3 mm fixed with saddles, insulators and screws etc for roof conductor and down conductor above ground, complete all as specified and as directed.

100

-

-

... More
Dismantling of complete Ceiling fan 1200/1400 mm sweep (i.e.,) down rod with its Canopies, Shackle, Condenser housing with its rubber bushes, split pins, unscrewing the body parts of Ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and rewinding of starter with suitable size of Copper enamelled wire, varnishing heating as per manufactures design and directed. (b) Re-assembling complete Ceiling fan by fixing only serviceable of old/new spare parts (i.e.,) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted Copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins, Refixing on site includind testing, commissioning complete all as specified and design to give designed air delivery including greasing, oiling etc all as directed. Note for Serial item No 93.00 to 96.00 (a) Supply only spare parts found unserviceable/defective will be measured and paid separately under relevant item of Sch 'A'. (b) The rate for fixing serviceable items are deemed to be included in unit rate of above item. (c) The Contractor has to quote credit for all retrived unserviceable item obtained from dismantling separately under relevant item of 'Schedule of Credit'.

120

-

-

... More
All as per serial item number 93.00 here-in-before but exhaust fan of size up to 450 mm sweep.

6

-

-

... More
All as per serial item number 93.00 here-in-before but Air circulator fan of size up to 610 mm sweep

2

-

-

... More
All as per serial item number 93.00 here-in-before but wall mounted fan of size 450 mm sweep.

2

-

-

... More
All as per serial item number 93.00 here-in-before but only overhauling of celing fan 1200mm/1400mm by greasing and oiling instead of rewinding of starter winding complete all as specified.

60

-

-

... More
All as per serial item number 94.00 here-in-before but exhaust fan of up to 450 mm sweep.

20

-

-

... More
All as per serial item number 95.00 here-in-before but Air circulater fan of up to 610 mm sweep.

10

-

-

... More
All as per serial item number 96.00 here-in-before but wall mounted fan up to 450 mm sweep.

8

-

-

... More
Supply only the following spare parts of fan of different makes and different sweep are as under:-

-

-

-

... More
Capacitor for ceiling fan as per existing make complete.

80

-

-

... More
Gun metal bush for ceiling fan as per existing make complete.

30

-

-

... More
Gun metal bush for wall mounted fan as per existing make complete.

8

-

-

... More
Gun metal bush for air circulator fan as per existing make complete.

7

-

-

... More
Ball bearing for wall mounted fan as per existing size and make complete.

6

-

-

... More
Ball bearing for air circulator fan as per existing size and make complete.

6

-

-

... More
Ball bearing for ceiling fan/Exhaust Fan as per existing size and make complete.

160

-

-

... More
Supply and fix three twisted copper flexible wire/cable of 0.5 sqmm complete all as specified and as directed. Make : PARAGON / KALINGA/ POLYCAB

70

-

-

... More
Supply and fix in repairs Apparatus assembly duly prewired without heating element and thermostat/thermal cutout for Geyser, storage type, 25/50 Ltr capacity complete all as specified and as directed.

13

-

-

... More
Supply and fix in repairs Thermostat/Thermal cut out as per sample for Geyser, storage type, 25/50 Ltr capacitycomplete all as specified and as directed.

13

-

-

... More
Supply and fix in repairs Heating element 1.5 KW/2 KW, any type as per sample (cup, thread, triangle base type), for Geyser, storage type, 25/50 Ltr capacity complete all as specified and as directed. Make : Bajaj/ Racold/ Sphern/ Johnson.

13

-

-

... More
Supply and fix in repairs PVC reinforced pipes 15mm dia both end socketed 450mm long heavy duty of suitable thickness for hot/cold water complete all as specified and as directed.

14

-

-

... More
Taking out inner tank assembly from Geysers of any capacity/make for repair /welding with brass brazing and refixing to its original position and making good complete all as specified and as directed.

13

-

-

... More
Material and labour in replacement of earthing complete with copper plate electrode 600 x 600 x 3.15 mm thick burried directly in ground earth pit not less than 2.25 mtr deep below ground level connected to & inclduing copper strip 20x3 mm by means of nuts and bolt check nuts and washers of galvanised iron sheet, passing through protection pipe of 25 mm dia light grade GI pipe all as shown in electrical plate Nos 3 of SSR Part-I, and connected to earthing test point complete inclduing testing filling of adquate quantity of charcoal dust and common salt inclduing refilling earth and removal of surplus soil upto 50 mtrs apart and PCC 1:3:6 type C1 chamber precast RCC cover 40mm thick nrinforces with 6 mm dia MS bar 3 Nos both way with handle made out of 20 mm dia MS base water pipe with wire mesh, funnel etc and connecting testing etc complete all as specified and directed.

8

-

-

... More
Demolition of existing damaged valve pits and provn of new earth pit chamber of size 30cmx30cmx30cm constructed in PCC (1:2:4) type B1 using 20mm graded aggregate including cast iron frame with hinged pit cover of size 12"x12" having 7 kg weight all as per electrical plate No.3 complete all as specified and as directed.

30

-

-

... More
Supply and fix in repair GI pipe of size 25 mm 1.5 RM long Light grade vertically fixed by means of PCC 1:2:4 of size 2x2x1.5 Cubic Feet for mounting of Copper air termination rod including fabrication work for mounting insulators on GI Pipe complete all as specified and as directed.

16

-

-

... More
Supply and fix in repair Copper strip 32x6 mm fixed with saddles, insulators and screws etc for roof conductor and down conductor above ground, including breazing at joints complete all as specified and as directed.

51

-

-

... More
Supply and fix in repair earthing strip insulators made of any material as PVC/Fiber/porcelain including nut and bolt suitable for fixing / support of copper/GI strip of size upto 32x6 mm complete all as specified and as directed.

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.