Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 95,600Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repairs To Sewage Lines, Manholes, Rain Water Pipes, Septic Tank, Soak Wells, Rcc Pipe, Covers Slabs, Plinth Protection, Joint Filling And Other Allied Works At Technical And Domestic Area Of Naval Base
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675319_1Bid Award Id
ViewTender No
8867/Okha/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIRS TO SEWAGE LINES, MANHOLES, RAIN WATER PIPES, SEPTIC TANK, SOAK WELLS, RCC PIPE, COVERS SLABS, PLINTH PROTECTION, JOINT FILLING AND OTHER ALLIED WORKS AT TECHNICAL AND DOMESTIC AREA OF NAVAL BASE OKHA UNDER GE NAVY PORBANDAR
Tender General Pages, Special Conditions and Particular Specifications of Contract
BOQ Items
Removal of blockage of sewage line of pipe up to 150 mm bore and systematically cleaning the same using necessary tools mechanically or manually such as passing rope knot bamboo kanti , jet auger, pressure tool and mechanical tools of description of required size including safety measures such as mask for gas etc all as per item of cleaning of manholes flushing the pipes with water after removal of blockage as specified.
9500
-
-
Taking out silt, brick, debris, liquids waste, sludge in solid / semi solid/ liquid state including complete cleaning of septic tank (bailing out water) and suitably disposing off outside MD land in covered container for the following capacities by mechanical means such as Jet auger and mechanical vacuum tank complete all as specified and directed by Engr-in-Charge.
-
-
-
upto 100 users capacity
10
-
-
101 to 200 users capacity
4
-
-
201 to 250 and above capacity
3
-
-
Cleaning of chocking / blocking of WHB / water closet (Indian/European WC), floor traps, Gully trap using necessary tools and cleaning /washing area and re-fixing the grating, etc in position after completion of job packing with white cement, all as specified and directed.
5200
-
-
Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete articles and precast concrete block walling etc. Complete all as specified and directed.
27
-
-
M & L for Porbandar Stone masonry walling or squared walling in cm 1:6, brought upto courses using dressed equal size Porbandar stone of superior quality complete all as specified and directed.
20
-
-
Ditto all as per above item No. 6.00 but except stones
7
-
-
Demolition of 200mm NP2 / SWG pipes fixed in any position or of any description complete all as specified and directed.
60
-
-
M&L for Reinforced concrete pipes 200mm bore of pipe, class NP3, laid in trenches and jointed complete with collars complete all as specified and directed.
60
-
-
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc. or shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft disintegrated rock including bracking haunching / pipe line below ground level complete as specified and directed.
14
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft disintegrated rock, complete all as specified.
6
-
-
Removing excavated material exc. 250 m but n exc. 500 m and
depositing where directed and depositing where directed as in rock complete.
8
-
-
M & L for PCC 1:3:6 type C-2 as in bed to drain pipes of 200mm bore including packing under and haunching against the sides of pipe after they are laid and tested, including filling complete all as specified and directed.
55
-
-
M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 200mm dia complete all as specified and directed.
10
-
-
M & L in repairs for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement
35
-
-
M & L in repairs Salt glazed stoneware gully traps, size 150x150mm, squre or round mouthed' with 'P' trap and encasing in PCC 1:3:6 type C-2 including excavation in any type of soil returning, filling in ramming and removal of surplus soil and CI grating as fixed in repairs complete all as specified and directed.
5
-
-
Demolition reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
6.3
-
-
M & L for Pre cast RCC (1:2:4) type B-1 using 20mm graded stone aggregates as in manhole cover and set in cement mortar (1:4) including necessary form work complete all as specified. (Reinforcement shall be measured & paid separately).
6.3
-
-
M & L for Mild steel CRS TMT steel bar for reinforcement 6-8 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed)not less than 0.9mm dia or securing with clips quality complete all as specified.
291
-
-
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
130
-
-
S & F of PVC (SWR) pipes repairs single socketed in any length with rubber ring joints fixed to walls of nominal bore 110mm of pressure rating 6kgs / cm2 in repair / replacement complete all as specified and directed.
75
-
-
S & F of PVC (SWR) pipes in repairs single socketed in any length with rubber ring joints fixed to walls of nominal bore 75mm of pressure rating 4kgs / cm2 in repair / replacement complete all as specified and directed.
55
-
-
S & F of PVC (SWR) bends in repairs any radius of nominal bore 110mm fixed in repair complete all as specified and directed.
25
-
-
S & F of PVC (SWR) bends in repairs any radius of nominal bore 75mm fixed in repair complete all as specified and directed.
18
-
-
S & F of PVC (SWR) couplers in repairs of nominal bore 110mm fixed in repair complete all as specified and directed.
25
-
-
S & F of PVC (SWR) couplers in repairs of nominal bore 75mm fixed in repair complete all as specified and directed.
14
-
-
M & L for fixed in repair Grating square 150 mm size of PTMT (Minimum weight 100gms) complete all as specified and directed.
50
-
-
Demolition of concrete surfaces in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
51.89
-
-
M & L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete.
4.5
-
-
M & L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations mass concrete complete all as specified and directed.
13
-
-
M & L for even spreading of 25mm thick layer of sand cushioning incl watering & consolidation all as specified & directed by Engineer-in-charge.
4.4
-
-
M & L for machine pressed precast concrete rubberised inter locking paver blocks any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade complete all as specified and directed by Engineer-in-charge.
175
-
-
M & L for PCC 1:2:4 type B-1 using (20mm graded crushed stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, Benching, kneelers, apex stones, bed plates, kerbs, saucer drain(including finishing top surface of drain even and smooth without using extra cement), water troughs and the like including weathering, slightly rounded or chamfered angles and throating, and similar work including use & waste of necessary form work complete all as specified and as directed.
2
-
-
M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed.
2.6
-
-
M & L for Cleaning and removing all scale and dirt etc from tanks & from mouths of circulating pipes etc of service water/loft tanks in / over roof buildings at different locations of capacities as under:
-
-
-
Capacity exceeding 250 but not exceeding 500 litres each
80
-
-
Capacity exceeding 501 litres but not exc 1000 litres each
40
-
-
Capacity exceeding 1001 litres but not exc 2000 litres each
Note for item No. 35.00:
1. The contractor will write date of cleaning& next due date of cleaning on Tank as directed by the Engr-in-Charge.
2. At the time of cleaning disconnected pipes/fittings shall be reconnected as per existing to make it leak proof complete all as directed by the Engr-in-Charge.
10
-
-
Taking up or down pvc/ steel tubing of 20 mm bore and connections
55
-
-
Taking up or down pvc/ steel tubing of 25/32 mm bore and connections
45
-
-
S & F uPVC pipes 20 mm bore of pressure rating 10 Kg/ Sqcm incl all fittings fixed complete to walls, ceilings or in floors etc.
55
-
-
S & F uPVC pipes 25 mm bore of pressure rating 10 Kg/ Sqcm incl all fittings fixed complete to walls, ceilings or in floors etc.
45
-
-
S & F in repairs Nipple suitable for HDPE water tank. (Minimum weight 15 mm-38gms/20mm 45gms /25mm- 65gms)
30
-
-
S & F in repairs HDPE PVC lid (cover) with locking arrangement for 500/1000 Ltrs capacity PVC tank complete all as specified.
163
-
-
S & F in repairs 25mm Ball (float) valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron/pvc/cpvc pipe and fixed. (Minimum weight 25mm-455gms)
81
-
-
S & F in repairs 20mm Ball (float) valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron/pvc/cpvc pipe and fixed. (Minimum weight 20 mm - 210 gms)
85
-
-
S & F in repairs viterous china wash down water closet pan (Pedestal pattern) white incl 'P' or 'S' trapand making good the disturbed surface to match with the existing complete all as specified and as directed.
3
-
-
S & F in repairs vitreous china squatting pan (Orissa pattern) long pan including provision of cement concrete bedding fixed in repair size 580x440mm white with intergral footrest with 'P' or 'S' trap complete all as specified.
4
-
-
S & F in repairs Plastic water closet seat cover, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device suitable for European / Anglo indian type WC all as specified and directed.
15
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding, and rubbish off the premisess complete all as specified and as directed
65
-
-
M & L for non-skid coloured ceramic tiles (300x300mm) x6 to 7mm thick in floor including screed bed 20mm thick in CM 1:4 etc set and jointed n neat cement slurry and pointed in coloured cement to match the shade complete all as specified
25
-
-
M & L for Glazed ceramic coloured printed tiles in vertical surface 300x450x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface of tile including 15mm thick screed in cm (1:4) as in skirting/dado complete all as specified and directed by Engr-in-Charge
40
-
-
Taking down cement plaster from brick or concrete surface incl raking out joints hacking for key and scrubbing down with water complete all as specified.
80
-
-
M & L for rendering 15 mm thick in two coats, 10mm thick in CM 1:4 backing coat and 5mm thick in CM 1: 4 mixed with WPC finished even and fair on stone masonry surfaces as specified.
130
-
-
M & L for Preparation of new plastered surfaces in walls soffits, facia roof and applying Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade(Company Depot Tinted) with silicon additives@ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. at any height including necessary scaffolding etc complete all as specified and as directed by Engr-in-Charge of weather coat primer all as specified.
80
-
-
Supply only integral water proofing compound complete all as specified and directed.
227
-
-
S & F in repair 10 litres PVC valveless, syphonic action type flushing cistern, with inlet ball valve, float and handleincloding brackets and PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified
37
-
-
Dismanting of PVC water tanks or any description and at any position and removing to store/ removing from site.
-
-
-
Exc 500 ltrs and n.exc 1000 ltrs capacity.
21
-
-
S & F 500 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed.
9
-
-
S & F 1000 ltrs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) incl connecting up pipes securing access covers etc as specified and as directed.
12
-
-
S & F in repairs Rimless Single Piece WC with UF Soft Close Slim Seat Cover, Hinges, Dual Flush Cistern Fitting, Fixing Accessories And Accessories Set, Size: 385x720x710 mm, S Trap- 300 mm in floor fixed in repair / replacement complete all as specified and directed. Make : Jaquar. Sample Approved by GE
1
-
-
S & F in repairs Wash Hand Basin, Vitreous China (flat back or angle back type)/oval shape any size, including cutting for and pinning in ends of brackets or erecting stand of size 550 X 400 complete all as per manufacturer's instructions and as required at site.
11
-
-
M & L for Broken stone Broken Loose filling with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells
4.5
-
-
Taking down / Demolition of old textile covering form roof (old WPT) complete all as specified and directed.
400
-
-
Demolition of PCC (unreinforced) in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified.
0.6
-
-
M & L Rendering 10 mm thick rendering in CM (1:4) over PCC padding surface finished even & smooth using extra cement with WPC @ 3% by weight of cement complete all as specified and directed (integral WPC will be measured separately)
380
-
-
M & L for PCC 1:2:4 type B-0 using (12.5 mm graded crushed stone aggregate) in padding concrete to over slab 40 mm thick (average) bedding layer mixed with WPC, finishing even and smooth without using extra cement complete all as specified and as directed.
Note : WPC & APP shall be measured and paid separately.
15
-
-
M & L for PCC 1:2:4 Type B0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges finish surface even and smooth including form work complete all as specified and directed
0.5
-
-
Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing.
Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions.
(ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. (iii) Preparation of new surfaces of roof slab and applying two coats of aluminium paint on (over APP Memberane) complete all as specified and as directed.
394
-
-
M&L for 75 mm thick cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in plinth protection/path laid to slope of 1 in 12 and finishing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges complete all as specified and directed.
281.25
-
-
M&L Forming Contraction (Dummy) joints 50 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade 'A' in plinth protection complete all as specified and as directed by Engr-in-Charge.
18.75
-
-
M&L for cement concrete 1:2:4 type B2 (40mm graded aggregate) 100mm thick as in flooring finished even joint filled with bitumen felt and smooth with using extra cement
200
-
-
M&L forming Construction joint 30mm deepx10mm wide filled with sealing compound.
20
-
-
Dismantling trellis work (Jafri) one way, including taking as under of battens in trellis (posts and rails measured separately)
50
-
-
Providing precast cement concrete louvres and jallies type B0 1:2:4 (12.5 mm graded aggregates), 35mm thick (measured solid) , including all mould- ings but excluding frame
50
-
-
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
118
-
-
Dismantling wrought iron or mild steel work of any description not otherwise described for of any description.
12.5
-
-
S&F mild steel rolled section Fe-410-W(Gde E-250), quality 'A' as in post, main and cross beams, rafters, purlins connected to common rafters fixed with angle iron clips or other connecting plates complete all as specified and directed.
770
-
-
S&F in repairs 5mm thick mild steel plates Fe-410 (Gde E-250) quality-A plain or chequered as in gates, shutters, similar steel structural works complete all as specified and directed.
10
-
-
S&F Rolled MS steel work in tubular trusses and tubular posts including special shaped washers etc., complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 graded ST 240 complete as specified and directed.
470
-
-
S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
118
-
-
Evaluation Notes How It Works ?