Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 8,980Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_621368_1Bid Award Id
ViewTender No
8924/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for rendering 15mm thick in two coat (10+5mm) cement plaster on concrete surfaces in CM 1:6 in base coat and 2nd coat 5mm thick in CM 1:4 using water profing compund (3% by weight) complete all as directed.
Note: WPC shall be measured and paid separately under relevant item of BOQ
31
-
-
Supply only integral water proofing compound all as specified and directed.
37
-
-
M&L preparation of new plastered surfaces of walls, and applying two coats of oil bound distemper over a coat of primer complete all as speified and as directed.
17
-
-
M &L for preparation of new plastered surfaces of walls and applying two coats of exterior emulsion paint over a coat of primer in camoflage pattern etc complete all as per specified and directed
31
-
-
M&L for stone aggregate hardcore of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
1
-
-
M&L for 100 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base flooring all as specified and directed
3
-
-
M & L for 75 mm thick Cement concrete type B1, 1:2:4 (20mm graded aggregate) finished even and smooth using extra cement complete all as specified and as directed.
134
-
-
M & L for 75 mm thick Cement concrete type B1, 1:2:4 (20mm graded aggregate) all as specified and as directed.
3
-
-
M & L for vitrified ceramic tiles 10 mm thick (square/rectangular) polished , area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm in floor etc. in white or coloured cement to match including 25 mm thick PCC 1:2:4 type B-0 (12.5 mm graded stone aggregate ) in floor ,set and jointed in neat cement slurry and pointed in white or coloured cement to match jointed in neat cement slurry and pointed in white /coloured cement over 10 mm thick screed bed in CM 1:4 all as specified and as directed
3
-
-
S & F in repairs, 10 ltr capacity PVC valve less syphonic action type, flushing cistern, low level, white with inlet ball valve, flush pipe float and handle including brackets complete all as specified and directed
2
-
-
M&L complete removal of existing water proofing treatment from top of roof and canopies/ chajjas of buildings including taking down plaster, padding concrete & removing the debris outside of MD land, roughening the old concrete roof/ floor by picking sweeping clean and washing down with water to removing dust etc., brushing neat cement slurry with 3.0 kg of cement per sq meter and rendering 10mm thick cement plaster in CM 1:3 on roof slab/canopies/ chajjas with water proofing compound @ 3 % of weight of cement and making plastered surfaces to receive water proofing treatment finished fair and even and preparing, clean and dry plastered roof surfaces and applying APP modified water proofing membrane with mineral finish, non woven polyster reinforcement/mat not less than 3mm thick having weight not less than 3kg/Sqm with overlapping of 10cm at joints over a coat of bitumenous filler/ primer conforming to IS 3384-1986 and applying @ 250gm/ Sqm through approved applicator and applying all as per manufacturers instructions complete all as specified and as directed.complete all as specified and directed.
Note:
1. The quoted rate is inclusive of removing earthstrip/cables and refixing the same after execution of water proofing membrane work. No claim what so ever shall be entertained on this issue in later stage.
2. Water proofing compound shall be measured and paid for seperately as supply only.
3. The quoted rates shall be inclusive of overlape.
120
-
-
M&L for 40 mm thick (average thickness) PCC (1:2:4), type B1, using 20mm graded stone aggregate as levelling course laid to slope as required, finished even & fair without using extra cement. complete all as specified and directed
120
-
-
M&L for preparation of old decorated/painted surfaces of walls and applying two coats of plastic emulsion paint complete all as specified and directed
48
-
-
S&F in position anodised aluminium powder coated (minimum 50 micron thickness) sliding door shutter with frame, partly glazed with 5.5mm thick tinted glass and partly panelled with 9 mm thick both side decorative prelaminated particle board exterior grade including rubber bead, joining cleat for fixing, aluminium door handle 150mm size and tower bolt 200mm size, double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing brass pivot, mortice lock vertical type of mild steel 4 levers of size 100mm etc as mentioned here in below complete all as specified and as directed:-
(a) Frame (top and side) section - 101.60 x 44.75 x 2.4mm (Section No. 14021)
(b) Vertical members of shutter Section-85.00 x 44.45 x 2.00 mm (Section No 19560)
(c) Top Members of shutter Section - 83.50 x 44.45 x 2.00mm (Section No 19581)
(d) Lock rail (middle member) of shutter Section - 150.00 x 44.45 x 3.00 mm (Section No. 19596)
(e) Bottom Members of shutter Section - 150.00 x 44.45 x 3.10mm (Section No. 19584)
(f) Glazing clip for securing glass - 0.80 mm thick (Section No. 19370).
Note:- Section No. given above are of make Jindal, Contractor may use similar section of other make mention in Appx A. Make:- Make of aluminium section : Jindal/ INDAL/ Hindalco as approved by GE
2.52
-
-
M&L for preparation of old painted wooden surfaces of any description, over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed
12.6
-
-
S&F for steel work Fe-410-W(Gde E-250) quality in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and directed
80
-
-
S&F for Mild steel screw bolts (machine made) length of bolt exc 22.5cm and n exc 30cm long with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long all as specified and directed
2
-
-
S&F for pre-prainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fix with self tapping screws all as specified and as directed
8
-
-
S&F in repair for 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers fixed in repair complete all as specified and directed.
1
-
-
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and as directed.
10
-
-
S&F in repair 15 mm dia CP pillar cock complete all as specified and directed
1
-
-
S&F in repair vitreous china wash basin white, flat back, size 550 x 400 mm including 15mm dia fancy type CP pillar tap, 32mm dia flexible waste pipe and fixing with brackets complete all as specified and directed
1
-
-
S&F in repairs PVC waste pipe flexible 32mm or 40mm bore 60cm long for sink or WHB complete all as specified and directed.
4
-
-
S&F in repairs 15 mm dia chromium plated bib cock with flange complete all as specified and directed
3
-
-
S&F in repairs 15mm bore chromium plated stop cock/angle cock Stop valves,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
6
-
-
S&F in repair Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete all as specified
3
-
-
S&F in repair flush pipe 32 mm dia for low level flushing cistern fixed in repairs complete including refixing of cistern at its position complete all as specified and directed.
2
-
-
M&L for preparation old plastered or unplastered, surfaces of walls and applying two coats of white wash all as specified and directed
50
-
-
Demolition of brick work or stone/boulder masonary, built in CM including all quions, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified
15.83
-
-
Demolition of RCC as in slab, beams floors (other than ground floor), staircases, landing, chajjas and similar suspended work complete all as specified and directed
27.48
-
-
Demolition of Reinforced Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
10.28
-
-
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
20.32
-
-
Removal of demolished materials etc. to out side MD land complete all as specified and directed.
Note: The location where the materials shall be removed shall be ascertained by contractor only. No claim what so ever shall be entertained on this account.
150.97
-
-
Taking down chowkhats or frames with shutters of any material (without taking off shutters from the frame) n. exc 1.50 sqm each complete all as specified and directed
4
-
-
Taking down chowkhats or frames of any material with shutter (without taking off shutters from the frame) n. exc 4.00 sqm each complete all as specified and directed
2
-
-
M&L for point wiring with 1.5 sq mm FRLS single core PVC insulated unsheathed 1100 V grade with multistranded copper conductor drawn through PVC conduct with all accessories concealed in the wall/roofs etc and incl provision of 1.5 sq mm PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly incl fabricated steel terminal box made out of 1.6 mm thick MS sheet concealed in the wall with 3 mm thick laminated sheet top cover for mounting the switches, socket outlets, fan regulators etc all as specified and directed for following.
-
-
-
One light/Fan point controlled by one switch.
2
-
-
One socket 3 pin outlet 5 amp on independent board.
2
-
-
One 3 pin socket outlet 5 amp on the same borad with other switches
1
-
-
All as per item No. 45 above but with copper conductor cable for one 3 pin socket outlet 15 amp independent board with cable 2.5sq mm and 2.5 sq mm copper cable as earth continuity conductor complete all as specified and directed
2
-
-
S & F switch piano flush type single pole one way 5 amp complete all as specified and directed
5
-
-
S&F ceiling rose three terminal/PVC polycarbonate, isolated body complete all as specified and as directed.
2
-
-
S&F switch socket combination 2 in 1,3 pin 5/15 amp flush type complete all as specified and directed
2
-
-
S&F switch socket combination 2 in 1,5 amp flush type complete all as specified and directed
2
-
-
S &F in replacement of socket outlet 2 in 1,3/5 pin 5 amp multi purpose, flush type complete all as specified and directed
1
-
-
Supply and fixing LED lights fitting 1x 18W, 220V AC decorative box type with driver, holder including LED tube light coonnecting up wirth three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
2
-
-
S&F in replacement sub main wiring drawing through PVC conduit with two single core 4 sq mm and one run of 4 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade complete all as specified and as directed.
Note : One run of PVC conduit and three runs of cabe shall be measured as one unit.
20
-
-
S&F in replacement of MCB DB SPN 4 ways double door with 240 volt, 200 amps rated bus bar with all accessories fixed in the wall including taking old DBs any type and cap and making good and match with the existing surface of wall all as specified and directed.
1
-
-
S&F in replacement of MCB 6 to 40 amps single pole 240 volts, complete all as specified and directed.
2
-
-
M&L for earthing complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary excavation, RFR, Removal with, providing RCC 1:2:4 type B1 with 40mm thick RCC cover with 6mm dia MS rods as in reinforcement at 150mm c/c both ways including testing on completion.
1
-
-
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed
6
-
-
Taking down regulator, sealing cable ends complete all as specified and directed
6
-
-
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
34
-
-
Taking out unserviceable LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc, and removing unserviceable cables, covers etc, for the 10x2 core. Complete all as specified and as directed.
40
-
-
Taking out unserviceable GI tubing from excavated trenches,wall etc for the size 25mm complete all as specified and as directed.
30
-
-
Taking out unserviceable DBs complete all as specified and as directed.
1
-
-