Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_674466_1Bid Award Id
ViewTender No
8797Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for in this Schedule and removal of entire debris as ordered outside MoD land complete all as specified & as directed.
14
-
-
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.
6
-
-
Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
7
-
-
Dismantling of Asbestos cement Corrugated or semi corrugated sheets etc any thickness including ridges as in roof covering and stacking at site where directed and removal of debris to outside MoD land and depositing where directed complete all as specified and as directed.
340
-
-
Dismantling wall and ceiling board (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness including cover fillets complete all as specified and as directed.
40
-
-
Dismantling of fencing wire mesh of any type and any size complete all as specified & as directed.
210
-
-
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
38
-
-
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
4
-
-
Taking down chowkat or frame with shutters (including fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.
15
-
-
Taking down shutters (including fittings & fixtures) of any description not exc 1 Sqm each, complete all as specified and as directed.
12
-
-
Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm but not exc 2 Sqm each, complete all as specified and as directed.
11
-
-
M&L for broken stone or boulders hardcore of gauge exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled rammed to a true surface complete all as specified and as directed.
5
-
-
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
7.8
-
-
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets, padding over roof and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
2.5
-
-
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed.
12
-
-
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks or slabs, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 in walls complete all as specified & as directed.
40
-
-
M&L for precast cement concrete (1:2:4 type B0 using 12.5mm graded crushed stone aggregate) louvers and jallies, 35mm thick (measured solid), including all mouldings but excluding frame, set in CM 1:4, complete all as specified & as directed.
12
-
-
M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, base of columns etc., basement slabs, under-reamed piles and mass concrete including necessary formwork complete all as specified and as directed.
Note: Reinforcement shall be measured and paid for separately.
2.5
-
-
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20mm graded crushed stone aggregate) in foundations including rafts, footings, foundation beams, bases for columns, mass concrete and the like complete all as specified & as directed.
Note :- Reinforcement & formwork shall be measured and paid for separately.
1
-
-
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20mm graded crushed stone aggregate) in columns, pillars, piers, posts, struts and the like complete all as specified & as directed.
Note :- Reinforcement & formwork shall be measured and paid for separately.
1.5
-
-
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20mm graded crushed stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified & as directed.
Note :- Reinforcement & formwork shall be measured and paid for separately.
1.5
-
-
Supply only Integral Water Proofing Compound (ISI Marked).
10
-
-
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified & as directed.
7
-
-
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal for rough finished flat surfaces of concrete complete all as specified & as directed.
9
-
-
Formwork to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & as directed.
7
-
-
S&F Second class hard wood kiln seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as specified and as directed.
0.25
-
-
S&F factory made 35 mm thick second class hard wood plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.
27
-
-
S&F factory made 35 mm thick second class hard wood glazed and skeleton door shutter open rebated and prepared to receive glass, guage etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (a), kiln seasoned and chemically pressure treated, supplied and fitted to chowkats, complete all as specified and as directed.
9
-
-
S&F factory made 30 mm thick second class hard wood glazed and skeleton window shutter open rebated and prepared to receive glass, guage etc edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (b), kiln seasoned and chemically pressure treated, supplied and fitted to chowkats complete all as specified and as directed.
18
-
-
S&F factory made Fibre Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame, complete as specified by the manufacturer and as per directions of Engineer-in-charge.
48
-
-
S&F factory made 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacturer, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
14
-
-
S&F 150 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
36
-
-
S&F 100 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
45
-
-
S&F 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .
54
-
-
S&F 100 mm size stainless steel butt hinges (ISI Marked), medium weight.
42
-
-
S&F 150mm size extruded aluminium alloy handles (ISI Marked), fabricated type, anodised and fixed.
56
-
-
S&F 100mm size extruded aluminium alloy handles (ISI Marked) fabricated type anodised and fixed.
36
-
-
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
16
-
-
S&F mild steel 300mm ordinary rat tail rod pattern spring including roller and roller plate, complete all as specified & as directed.
3
-
-
S&F gate and shutter, hooks and eyes, aluminium powder coated plate type II, 150 mm size.
16
-
-
S&F 80mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door as directed.
Note :- Door stopper shall be conforming to the sample kept in GE’s office.
16
-
-
S&F XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.
8
-
-
S&F in repairs XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.
25
-
-
S&F mild steel work as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc., round bars, flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Grade E-165 (Fe 290), complete, all as specified & as directed.
900
-
-
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed.
90
-
-
S&F mild steel screw bolts of 5-10 mm diameter of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt not exceeding 5 cm long, complete all as specified & as directed.
25
-
-
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
280
-
-
All as per serial item No. 50 here-in-before but bars 6 to 8 mm dia.
25
-
-
All as per serial item No. 50 here-in-before but 6 to 10 mm dia in stirrups, spacers and binders.
40
-
-
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-410 W (Gde E-250) quality-A complete all as specified and as directed.
400
-
-
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed.
25
-
-
S&F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete conforming to Fe 290 (Gde E-165) complete all as specified and as directed.
450
-
-
Fixing only mild steel galvanized chain link fencing, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified & as directed.
Note :- Supply only chain link fencing shall be measured and paid for separately.
210
-
-
Supply only mild steel galvanized chain link fencing (Coating 120 to 140 GSM) not more than 4mm dia of mesh wire, 75mm x 75mm mesh size (or as directed by Engineer-in-Charge) including line wire complete all as specified and as directed.
600
-
-
S&F galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc including dismantling galvanized steel barbed wire of any description fixed to any type of fencing posts complete all as specified & as directed.
Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
1
-
-
S&F steel rolling shutters of 1.00 mm thickness of laths, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, without ball bearing, erected in position as indicated, including dismantling & taking down the existing unserviceable rolling shutter, complete all as specified and as directed.
16
-
-
S&F perforated steel rolling shutters of 1.00 mm thickness of laths, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, without ball bearing, erected in position as indicated, including dismantling & taking down the existing unserviceable rolling shutter, complete all as specified and as directed.
9
-
-
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified & as directed.
6
-
-
S&F Ball bearing for rolling shutters complete all as specified & as directed.
6
-
-
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ ridges/ cladding to walls, fixed with self tapping screws complete all as specified & as directed.
Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc
320
-
-
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ cladding to walls, ridges, gutters, valleys etc. fixed with self tapping screws complete all as specified & as directed.
Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc
20
-
-
S&F 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board with frame work with screws fixed to false ceiling with and including MS powder coated (white) snap Grid of size 605x605 mm frame work using 24mm x 32mm x 0.7mm main ‘Tee’ runner to be interlocked, 24mm x 32mm x 0.70mm cross ‘Tee’ and 24mm x 32mm x 0.70mm angles fixed to wall for ceiling including necessary supporting hanger with 4 mm dia GI wire (upto 3.5m long adjustable) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 24x7mm size 60mm long for securing frame work to ceiling suspended @ 1200mm centre to centre both way with PVC rawl plug with & including 6mm thick calcium silicate board as described fixing with clips etc. and ceiling board fixed as per manufacturer’s instructions, with & including painting the ceiling board with two coats of oil emulsion distemper (OBD) of approved shade over a coat of primer on ceiling with & including taking down existing electrical fittings/fixtures and wiring in ceiling and re-fixing the same to its original position or different locations, after completion of false ceiling work including testing on completion as ordered complete all as specified & as directed.
40
-
-
S&F 3mm thick Aluminium Composite Panel (ACP) sheets cladding, eaves, etc, vertical or horizontal, with and including fixing in necessary Aluminium frame work flat, angle or T as per best trade practice and filling the joints/grooves with non staining silicone sealant including fixing of angle cleats, screws etc complete all as specified and as directed. Make : Viva, Aludecor, Reynobond, Virgo, Alex Panels, Indo Bond, Euro bond, Alstrong, Rinac, Areca Alupanel or equivalent as approved by GE.
Notes : (i) Colour of ACP sheets shall be as approved by GE. (ii) Frame work is included in this item. (iii) The decision of GE regarding Frame work as per best trade practice shall be final & binding.
20
-
-
M&L for Stainless steel letters, figures, symbols, etc made of 0.6mm thick stainless steel sheet, size exceeding 20cm but upto 30cm height and upto 20cm width, fixed as per standard trade practice as in sign boards etc, complete all as directed by Engineer-in-Charge.
Note: Size, Font, pattern, etc of letters, figures, symbols, etc shall be as directed by Engineer-in-Charge.
22
-
-
S&F in repair 5mm thick acrylic sheet (white/ blue or other colour as approved by EIC) in sign boards etc complete all as directed.
9
-
-
M&L for English letters, Hindi letters, Sign, Arrow, digits, etc of size exceeding 10cm but upto 15cm height and upto 5cm width each made by computerized cutting from High Intensity Retro reflective grade radium sheet of Yellow/ White/ other Colour as directed and mechanically fixed on ACP board with suitable high grade adhesive complete all as specified & as directed.
Note: Size, Font, pattern, etc shall be as directed by Engineer-in-Charge.
30
-
-
M&L for English letters, Hindi letters, Sign, Arrow, digits, etc of size exceeding 15cm but upto 30cm height and upto 15cm width each made by computerized cutting from High Intensity Retro reflective grade radium sheet of Yellow/ White/ other Colour as directed and mechanically fixed on ACP board with suitable high grade adhesive complete all as specified & as directed.
Note: Size, Font, pattern, etc shall be as directed by Engineer-in-Charge.
40
-
-
M&L for cutting out cracks to 'V' section in existing roofs or terrace cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & as directed.
20
-
-
Material and labour for complete removal of existing water proofing treatment of any description or any other type of treatment over roof slab, parapets, chimney stacks, etc including cement plaster and cleaning the surface with wire brushes and washing with water, removing of insolvent materials and removing & depositing the debris, rubbish, etc outside MoD land, brushing neat cement slurry @ 3 Kg of cement per Sqm over the cleaned surface and provide 15mm thick screed bed/bedding layer/plaster in CM 1:3 mixed with integral Water Proofing Compound (WPC) as per manufacturer's instructions and finishing the surface even & smooth without using extra cement while the cement slurry is still green on RCC roof/parapet, provide oil bound bituminous primer @ 0.30 Kg/Sqm after bedding layer/plaster is cured with water for 7 days & completely dried, provide minimum 4mm thick APP based modified polymeric water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 160 gms/Sqm with over laps 100 mm longitudinal direction (side laps) and 150 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed and finally finishing the top surface with one finishing coat of bituminous aluminium paint complete all as specified and as directed.
Notes: (i) WPC shall be measured & paid for separately as ‘Supply only’. (ii) The work shall be carried out only through manufacturer or their authorised applicator and contractor shall submit a written guarantee of the manufacturer/authorised applicator for the effectiveness of WPT for 10 years from the date of completion of contract. (iii) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (iv) The net area of water proofing treatment shall be measured without any extra allowance for laps.
50
-
-
M&L for machine cut mirror polished Kota stone slab 18 to 22mm thick laid in floors etc over & including screed bed or bedding layer of 20mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
30
-
-
M&L for machine cut mirror polished Kota stone 12 to 15mm thick on vertical surfaces such as dado, skirting etc. laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.
Note : Quoted rate shall deemed to be inclusive of rendering (as screed bed).
10
-
-
M&L for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
6
-
-
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed.
Note : Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.
120
-
-
M&L for 100 mm thick PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in flooring etc laying in alternate panels with broom finish complete all as specified and as directed.
80
-
-
M&L for 75mm thick PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed.
300
-
-
M&L for average 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in levelling course of floor finishes complete all as specified and as directed.
30
-
-
M&L for 40mm thick plain cement concrete 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in flooring, finished the surface even & smooth without using extra cement, complete all as specified and as directed.
Note :(i) Quoted rate shall deemed to be inclusive of inserting diving strips. (ii) Dividing strip shall be measured & paid separately as “Supply only”.
80
-
-
Supply only glass dividing strips, 38 mm width and 3 mm thick inserted in position, conform to design complete all as specified and as directed.
35
-
-
M&L for non skid joint free ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
8
-
-
M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
30
-
-
M&L for factory made M-35 grade, 60 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE.
250
-
-
Dismantling & taking out carefully existing serviceable undulated 40 to 80 mm thick precast cement concrete interlocking paver blocks including sand cushioning and re-laying the same at same location over and including new 50mm thick compacted sand cushioning complete all as specified and as directed.
Note : Quoted rate shall deemed to be inclusive of new 50 mm thick compacted sand cushioning.
80
-
-
M&L for machine pressed coloured chequered cement concrete tiles of size 295x295x25 mm thick with grey cement and pigments, set and jointed in neat cement slurry in floors and pointed with coloured cement to match the shade of tiles and laying over & including 15 mm thick screed bed in CM 1:6 complete all as specified.
Notes: (i) Quoted rate shall deemed to be inclusive of cement screed. (ii) Colour of tiles shall be got appproved from GE before incorporation in the work.
120
-
-
M&L for precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in Kerb block (Kerb Stone), factory casted, with plain fair faces, size 10cm x 30cm each or as directed, including weathering, slightly rounded or chamfered angle throating, with plain or interlocking joints and setting in cement mortar 1:4, fixed in position to the required line, level and curvature including making drainage opening wherever required, complete all as specified & as directed.
Note : Shape & size of Kerb blocks shall be as approved by the GE.
1
-
-
M&L for Rendering 20 mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair face of brick work of walls mixed with WPC mixed @ minimum 2% by weight of cement or as per manufacturer instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as 'Supply only'.
60
-
-
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.
100
-
-
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall, finished even & smooth without using extra cement complete all as specified and as directed.
100
-
-
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.
30
-
-
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, Jet pressure washing and preparation of plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
250
-
-
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick layer of white cement based wall care putty complete all as specified & as directed.
200
-
-
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of wall and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.
400
-
-
M&L for preparation of newly plastered surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.
30
-
-
M&L for preparation of old decorated surfaces of wall including cornices etc (plastered or unplastered) of any description, rubbing, scrapping by hand held sander / long handle sander and washing and applying one coat of cement based paint of approved shade/tint by mechanical means complete all as specified and as directed.
400
-
-
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing of surfaces of wall & applying two coats of cement base paint of approved shade/tint over a coat of alkali resistant priming paint complete all as specified & as directed.
100
-
-
M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
100
-
-
M&L for preparation of old decorated surfaces of walls including cornices etc (plastered or unplastered) of any description, rubbing, scrapping by hand held sander / long handle sander and Jet pressure washing and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm applied by mechanical means i.e Airless spray complete all as specified and as directed.
400
-
-
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.
300
-
-
M&L for preparation of old painted surface of Kerb stones, decorative wall and the like and applying one coat of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm as per manufacturer's instructions in alternate panels in different shade/tint complete all as specified and as directed.
Note : Painting to Kerb stones, decorative wall, etc in alternate shade/tint as approved by Engineer-in-Charge shall be carried out.
15
-
-
Hacking out old broken glass any thickness, size, quality or description from wooden frames glazed with putty or fixed with wooden beads or from metal frames complete all as directed.
14
-
-
S&F 3mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as specified & as directed.
22
-
-
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.
96
-
-
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed.
240
-
-
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.
110
-
-
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed.
220
-
-
M&L for forming 12 mm thick expansion joints for 100 mm thick concrete slab, filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound Grade ‘A’ complete all as specified.
1
-
-
M&L for forming Construction joints 30mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified.
5
-
-
M&L for application of high build polymer modified cement mortar (1:3) mixed with 6 ltrs SBR latex per bag of cement {Compressive strength after 28 days ≥ 40 N/sqmm (According to ASTM C109)} in small patch work over column/ beams/ ceilings / walls surfaces 25 to 40mm thick in two layers over a coat of bonding agent like Nitobond SBR (1 ltr SBR + 3 Kg cement) applied as per manufacturer’s instructions for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Note :- SBR latex chemical shall be measured and paid for separately as ‘Supply only’.
40
-
-
Supply only SBR latex chemical of Make Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian as approved by GE.
70
-
-
E&M Items: Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
83
-
-
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including heavy duty PVC casing and capping double lock type (minimum 25 mm wide, ISI marked) with accessories or non-metallic rigid PVC conduit (heavy duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc, fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws all as per IS, terminated in & including new sheet metal box, terminal plates with all accessories, concealed MS box/ PVC modular box with cover suitable for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed.
Note : Cost of cutting/leaving, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
55
-
-
All as per serial item No. 112 here-in-before but for one 3 pin 5/6 Amp modular switch socket on same board with other switches.
6
-
-
All as per serial item No. 112 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
14
-
-
All as per serial item No. 112 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
8
-
-
S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed.
75
-
-
S&F in repairs modular switch, single pole, one way, 16 Amp, 1 module with all accessories complete all as directed.
8
-
-
S&F in repairs modular socket 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as directed.
20
-
-
S&F in repairs modular socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as directed.
8
-
-
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
55
-
-
S&F in repair modular step type fan regulator 120 W, 2 module, AC, 230V, electronic complete all as specified and as directed.
8
-
-
Taking down existing batten type light fitting of any description & fixed in any position and S&F new clear white 20 Watt wall mounted 4 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
35
-
-
Taking down existing batten type light fitting of any description & fixed in any position and S&F new clear white 10 Watt wall mounted 2 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.
5
-
-
Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, fixed over & including mounting bracket made of 32mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed.
10
-
-
Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed.
10
-
-
Taking down existing post top lantern of any description and S&F new 45W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj 'BGCTN 45W LED WW' or equivalent in makes mentioned in Appendix 'B' here-in-after.
10
-
-
M&L in repair for street light bracket made from MS tubing in required size & shape at site, cut to length, bend to shape required and suitable for existing street light pole and fixing the bracket to pole with MS flat and nuts and bolts and finally painting the exposed steel surface with two coats of first quality synthetic enamel paint of approved tint over a coat of zinc chromate primer complete all as directed. Notes :- (i) Size, section and shape of MS pipe shall be as directed. (ii) Quoted rate shall deemed to be inclusive of painting. Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
30
-
-
Dismantling and taking down existing damaged/broken PCC Pole and S&F new 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 Amp, 240 V, 10 kA, 'C' Curve (1 No.), MCB TP 32 Amp, 415 V, 10 kA, 'C' Curve (1 No.) & Connector (RYB&N) - 63 A Cap (01 No.) complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-6030 (BOPH-6030) or equivalent in makes mentioned in Appendix 'B' here-in-after.
Note: Earth work and PCC foundation shall be measured & paid for separately.
10
-
-
S&F in repairs 3 core, 2.5 sqmm PVC insulated sheathed multistranded flexible copper conductor cable (ISI marked) 1100 Volts grade drawn through existing conduit pipe from junction box to fitting complete all as directed.
110
-
-
S&F in repairs Junction box made from SMC/FRP sheet readymade of size 300x200x100 mm having 100 A capacity including RYB and neutral with aluminium busbar, with & including MCB SP 6 Amp 10 kA 'C' Curve 240 V (01 No.) fixed to pole/wall with MS clamp made out of MS flat iron 25x5 mm with suitable nut, bolts, etc and necessary painting to MS clamp with two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified & as directed.
10
-
-
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 8 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
4
-
-
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
24
-
-
S&F in repairs MCB SPN 40 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
4
-
-
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories or heavy duty non-metallic rigid PVC conduit (ISI marked) & conduit fittings/accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed.
Note :- 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.
110
-
-
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed.
Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
200
-
-
Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
150
-
-
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
12
-
-
M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed.
12
-
-
M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed. Notes :-
(i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used.
(ii) For the purpose of payment, only punned thickness shall be measured.
8
-
-
S&F in repairs 10mm thick chequered type insulating electrical rubber mat of size 4 x 8 ft (ISI Marked) complete all as specified & as directed.
6
-
-
M&L for Navy Blue LED sign board of size 3ft x 2.5ft with white Alphabets/ Letters, out door type, totally enclosed with locking arrangement, 5mm thick acrylic sheet, iron frame angle of size 45x45x5mm with minimum 4ft height from ground level and 1ft in depth grouted in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) for sub-station/ plant with LED lights as directed (minimum 06 Nos of 10W LED light) and internal wiring complete with electrical connection from nearest street light pole/ panel including testing after completion with & including all standard accessories as per standard trade practice including two coats of synthetic enamel painting of approved tint over a coat of zinc chrome primer after preparation of steel surfaces of MS frame work complete all as directed by Engineer-in-Charge.
Note: Quoted rate shall deemed to be inclusive of PCC, LED lights and electrical connections. Letters/matter/logo/sign etc for sign board shall be given by the Engineer-in-Charge as per location of sign board. The lettering font & style, lightning work, etc shall be as directed by Engineer-in-Charge.
4
-
-
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment, conforming to Fe-410-W (Gde E-250) quality `A’, fixed in repairs, complete all as specified and as directed.
250
-
-
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
6
-
-
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in any type of soil (i.e. soft/ loose or hard/ dense soil) complete all as specified and as directed.
55
-
-
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
48
-
-
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
7
-
-